MONTHYEARML20112K0441985-04-0505 April 1985
[table view]Proposed Tech Spec 3.6.5.1,incorporating Westinghouse Reanalysis of Containment Pressure Calculation ML20112K0371985-04-0505 April 1985 Application for Amend to Licenses NPF-9 & NPF-17,revising Tech Spec 3.6.5.1 to Incorporate Results of Westinghouse Reanalysis of Containment Pressure Calculation.Fee Paid ML20133H7291985-07-31031 July 1985 Notice of Consideration of Issuance of Amends to Licenses NPF-9 & NPF-17 & Opportunity for Prior Hearing.Amends Change Tech Specs to Allow Operation W/Reduction in Total Min Weight of Ice in Containment Ice Condenser Sys ML20133H7141985-07-31031 July 1985 Informs That Proposed Amend Re Ice Bed Weight Based Upon Rev to Design Basis Containment Pressure Calculation in FSAR Section 6.2.1 & Involves Significant Hazards Consideration. Encl Notice of Opportunity for Prior Hearing Issued ML20198B7691985-10-31031 October 1985 Withdraws 850405 Application for Amends to Licenses NPF-9 & NPF-17,revising Min Ice Bed Weight Required by Tech Specs, Due to Error in Input Assumptions Used to Provide Technical Justification for Amend 05000369/LER-1985-029-01, :on 851001,Westinghouse Notified Util That Reanalysis of Peak Containment Pressure Calculation Resulted in Greater Value than Internal Pressure of 15 Psig.Emergency Procedure for Nd Spray Initiation Revised1985-10-31031 October 1985
ML20138J5761985-12-10010 December 1985 Notice of Withdrawal of Application for Amends to Licenses NPF-9 & NPF-17.Request Granted Due to Error in Input Assumptions to Computer Code Used to Provide Technical Justification 1985-12-10 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:57335&oldid=5489077"