| 05000362/LER-1992-001-01, :on 920225,containment Purge Isolation Sys Actuated.Caused by Personnel Error.Signs Installed Near Monitors Reminding Personnel of Responsibility for Control Room Notification |
- on 920225,containment Purge Isolation Sys Actuated.Caused by Personnel Error.Signs Installed Near Monitors Reminding Personnel of Responsibility for Control Room Notification
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(viii)(A) |
| 05000361/LER-1992-002, :on 920209,CR Isolation Sys Actuation,Automatic Start of EDG 3G002 Occurred Due to de-energization of ESFs Actuation Sys Power Supply.Esfas Dc Power Supply Breaker Reclosed |
- on 920209,CR Isolation Sys Actuation,Automatic Start of EDG 3G002 Occurred Due to de-energization of ESFs Actuation Sys Power Supply.Esfas Dc Power Supply Breaker Reclosed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000362/LER-1992-002-01, :on 920219,determined That Source Range Neutron Flux Monitor Was Not Providing Audible Indication,Per TS 3.9.2.Caused by Audible Count Rate Booster Amplifer Being in Off Position.Subj Amplifer re-energized |
- on 920219,determined That Source Range Neutron Flux Monitor Was Not Providing Audible Indication,Per TS 3.9.2.Caused by Audible Count Rate Booster Amplifer Being in Off Position.Subj Amplifer re-energized
| 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000206/LER-1992-003-02, :on 921219,sample Incorrectly Taken from out-of-svc Wgdt Due to Personnel Error.Technicians Involved Received Appropriate Disciplinary Action |
- on 921219,sample Incorrectly Taken from out-of-svc Wgdt Due to Personnel Error.Technicians Involved Received Appropriate Disciplinary Action
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1992-003, :on 920211,control Room Isolation Actuation & Automatic Start of Emergency Diesel Generator 3G002 Occurred.Caused by Deenergization of ESF Actuation Sys Power Supply.Event Was Reviewed W/Personnel |
- on 920211,control Room Isolation Actuation & Automatic Start of Emergency Diesel Generator 3G002 Occurred.Caused by Deenergization of ESF Actuation Sys Power Supply.Event Was Reviewed W/Personnel
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000362/LER-1992-003-01, :on 920515,reactor Coolant Pump Tripped.Caused by Phase C Differential Relay Operation on RCP Supply Breaker.Rcp Motor Preventive Maint Program Modified to Include Periodic Replacement of Capacitors |
- on 920515,reactor Coolant Pump Tripped.Caused by Phase C Differential Relay Operation on RCP Supply Breaker.Rcp Motor Preventive Maint Program Modified to Include Periodic Replacement of Capacitors
| 10 CFR 50.73(a)(2) |
| 05000362/LER-1992-004, :on 920720,manual Initiation of Emergency FW Actuation Sys Occurred in Response to Trip of Mfpt.Caused by Low Bearing Lube Oil Pressure Condition of Associated MFP 3P062.PRV 3PCV-4270 Adjusted |
- on 920720,manual Initiation of Emergency FW Actuation Sys Occurred in Response to Trip of Mfpt.Caused by Low Bearing Lube Oil Pressure Condition of Associated MFP 3P062.PRV 3PCV-4270 Adjusted
| |
| 05000361/LER-1992-004, :on 920218,dye-penetrant Exam of Pressurizer Vapor Space Level Instrument Nozzle Revealed Presence of Crack.Caused by Primary Water Stress Corrosion Cracking. Vapor Nozzles Will Be Replaced W/Inconel 600 |
- on 920218,dye-penetrant Exam of Pressurizer Vapor Space Level Instrument Nozzle Revealed Presence of Crack.Caused by Primary Water Stress Corrosion Cracking. Vapor Nozzles Will Be Replaced W/Inconel 600
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1992-007, :on 920226,TDAFWP P-140 Tripped on Overspeed During Startup for Inservice Test Surveillance.Caused by Introduction of Accumulated Condensed Steam Into Pump Turbine.Replaced Clogged Steam Trap Strainer |
- on 920226,TDAFWP P-140 Tripped on Overspeed During Startup for Inservice Test Surveillance.Caused by Introduction of Accumulated Condensed Steam Into Pump Turbine.Replaced Clogged Steam Trap Strainer
| 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1992-008-01, :on 920424,automatic Turbine Trip/Reactor Trip Occurred.Caused by Failure of Transformer 2B13X.Transformer Was Replaced |
- on 920424,automatic Turbine Trip/Reactor Trip Occurred.Caused by Failure of Transformer 2B13X.Transformer Was Replaced
| 10 CFR 50.73(a)(2) |
| 05000361/LER-1992-008, :on 920218,primary Water Stress Corrosion Cracking of Pressurizer Instrument Nozzles.Noted.Caused by Rust & Boric Acid Crystals.Nozzle Replaced & Interim Repair Will Be Implemented |
- on 920218,primary Water Stress Corrosion Cracking of Pressurizer Instrument Nozzles.Noted.Caused by Rust & Boric Acid Crystals.Nozzle Replaced & Interim Repair Will Be Implemented
| 10 CFR 50.73(a)(2) |
| 05000361/LER-1992-009-01, Forwards LER 92-009-01 Re Misalignment of Salt Water Cooling Pump Emergency Seal Water Supply Isolation Valve | Forwards LER 92-009-01 Re Misalignment of Salt Water Cooling Pump Emergency Seal Water Supply Isolation Valve | |
| 05000361/LER-1992-009, :on 920614,discovered That Salt Water Cooling Pump P112 Emergency Seal Water Isolation Valve MU019 Closed. Caused by Valve Misalignment on 920528.Water Supply Restored & Event Reviewed by Engineering Personnel |
- on 920614,discovered That Salt Water Cooling Pump P112 Emergency Seal Water Isolation Valve MU019 Closed. Caused by Valve Misalignment on 920528.Water Supply Restored & Event Reviewed by Engineering Personnel
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000361/LER-1992-010, :on 920506,spurious Train a Toxic Gas Isolation Sys Actuation Occurred Due to Momentary High Ammonia Concentration Signal.Caused by Intermittent Electronic Problem or Noise Spike.Train Returned to Svc |
- on 920506,spurious Train a Toxic Gas Isolation Sys Actuation Occurred Due to Momentary High Ammonia Concentration Signal.Caused by Intermittent Electronic Problem or Noise Spike.Train Returned to Svc
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1992-011, :on 921005,discovered That Fire Sys Impairment Compensatory Actions Not Performed Per TS 3.7.8.3,due to Cognitive Personnel Error.Officers Involved in Event Received Counseling |
- on 921005,discovered That Fire Sys Impairment Compensatory Actions Not Performed Per TS 3.7.8.3,due to Cognitive Personnel Error.Officers Involved in Event Received Counseling
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1992-011, :on 900722,AFW Bypass Control Valve 3HV-4763 Failed to Close Upon Demand.Caused by Failed Actuator Solenoid Valve Which Prevented Closure.Valve 3HV-4763 Manually Isolated |
- on 900722,AFW Bypass Control Valve 3HV-4763 Failed to Close Upon Demand.Caused by Failed Actuator Solenoid Valve Which Prevented Closure.Valve 3HV-4763 Manually Isolated
| 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1992-012, :on 920731,automatic Reactor Trip Occurred When Potential Transformer Drawer Opened for Thermographic Insps, Resulting in Trip of Reactor Coolant Pumps.Caused by Inadequate Warning Sign.Guidelines Enhanced |
- on 920731,automatic Reactor Trip Occurred When Potential Transformer Drawer Opened for Thermographic Insps, Resulting in Trip of Reactor Coolant Pumps.Caused by Inadequate Warning Sign.Guidelines Enhanced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000361/LER-1992-013, :on 921209,identified Deficiency Involving Check Valve Test Methodology.Applicable Check Valve Procedure Modified.Applicable SONGS Units 2 & 3 IST Implementing Procedures Will Be Evaluated |
- on 921209,identified Deficiency Involving Check Valve Test Methodology.Applicable Check Valve Procedure Modified.Applicable SONGS Units 2 & 3 IST Implementing Procedures Will Be Evaluated
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |