ML20126G028

From kanterella
Jump to navigation Jump to search
Replacement Pages to Semiannual Radiological Effluent Release Rept,First Half 1992
ML20126G028
Person / Time
Site: Wolf Creek 
Issue date: 06/30/1992
From:
WOLF CREEK NUCLEAR OPERATING CORP.
To:
Shared Package
ML20126F953 List:
References
NUDOCS 9301040027
Download: ML20126G028 (3)


Text

_

.t o.

9 Attachment to NA 92-0141 Replacement Pages 17-18 for Attachment to NA 92-0035 2

y b

9301040027 921228 ADOCK 05000482.

. PDR PDR:

.R..

.Enclosuretto NA 92-0035 Page 17 of 23' a

EFFLUENT AND WASTE DISPOSAL SDHIANNUAL-REPORT (1992)

SOLID WASTE SHIPMENTS A.

S01ID WASTE S!!IPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)

1. Type of waste Unit 6-Month Est. Total Period

-Error 2

a. Spent resins, filter sludges, m3*

7.10E+00 evaporator bottoms, etc.

Ci.

9.58E+01 2.50Et01

b. Dry compressible waste, m3*

1.67E+01 contaminated equip. etc.

C1 4.22E-01 2.50E+01

c. Irradiated components, m3*

0.00E+00 control rods, etc.

Ci 0.00E+00 0.00E+00

d. Other m3*

0.00E+00 Ci 0.00E+00 0.00E+00 m3* = cubic meters

2. Estimate-of major nuclide composition (by type of waste) a.

Spent resins, filter sludges, evaporator bottoms, etc.

Nuclide Percent Name Abundance Curies Cs-134 24.061%

2.30E+01 Cs-137 20.848Z 2.00E+01

-j Fe-55 20.420Z 1.96E+01 Ni-63 14.694%

1.41E+01-Co-60 8.860%

8.49E+00 Co-58 4.3322 4.15E+00=

Be-7 3.257%

3.12E+00 i

Mn-54 2.127%

2.04E+00 Eu-155 1.274Z 1.22E+00 C-14

.076Z 7.28E-02

)

Sr-90

-.028Z 2.66E-02 i

H-3

.023%

2.19E-02 l

Pu-238

.000%

4.01E-05 Pu-239/40

.000%.

3.94E-05 Cm-243/44

.n00%

2.10E-05 Am-241

.000%

1.54E-05 Cm-242

.0002

.0.00E+00 Pu-241

.000%

0.00E+00 1-129

.000%

0.00E+00 Tc-99

.000Z 0.00E+00 Nb-94

.000%

0.00E+00 Ni-59

.000%-

0.00E+00 i

ll

l 4;g.

Enclosure _to;NA-92-0035

(

.Page 18 of 23-b.-Dry compressibleLwaste,_ contaminated equipment. etc.

Nuclide Percent Name Abundance Curies Fe-55 54.755Z 2.31E Co-60 26.582%

1.12E-01 Ni-63 8.258Z 3.48E-02 Co-58 3.6822 1.55E-02 Nb-95 1.821%

7.68E-03 Cs-137 1.698Z 7.16E-03 Mn-54 1.328Z 5.60E-03 Cs-134-1.2782 5.39E _

I-131

.5302 2.23E-03 H-3

.0362 1.50E-04 Cr-51

.028%

1.19E-04 C-14

.004%_

1.66E-05 Cm-242

.000Z 0.00E+00 Pu-241

.000Z 0.00Et00 I-129 000%

0.00E+00 Tc-99

.000%

0.00E+00 Sr-90

.0001 0.00E+00 Nb-94

.000%

0.00E+00 Ni-59

.000%

0.00E+00 c.

Irradiated components, control rods, etc.

none d.

Other none r3. Solid Vaste Disposition Number of Shipments Mode of Transportation Destination ~

5

_ Truck

'Barnwell,:

South Carolina-4

' Truck'

'Richland, Washington

4. Class of Solid Waste

-a.-

Class A. Class B b.- Class A c.-

Not applicable d.

Not applicable

5. Type of Container a.

LSA (Strong.-tight)

~b.

LSA (Strong.' tight) c.

Not applicable d.

Not. applicable m