HTS-287 Attaclment 1 to i

14G-95-3121

~

Q GE NuclearEnergy

.173 Curtner Ave San Jose, CA 95125 GENE-A00-04021-01 Class I APPLICATION OF THE " REGIONAL EXCLUSION WITH FLOW-BIASED APRM NEUTRON FLUX SCRAM" STABILITY SOLUTION (OPTION I-D)

TO THE DUANE ARNOLD ENERGY CENTER Licensing Topical Report September 1995 4

l Prepared forIES Utilities by GE Nuclear Energy f

Approved by:

on Post chnical Services M

e 951209C061 951130

~

PDR ADOCK 05000331

-.E.._.___..

fDR

.i

\\

GENE-A00-04021-01 IMPORTANT NOTICE REGARDING CONTENTS OF THIS REPORT Please Read Carefully i-The only undertakings of GE Nuclear Energy respecting information in this document are contained in the contract between the Customer and GE Nuclear Energy, as identified in the purchase order for this report, and nothing contained in this document shall be construed as changing the contract. The use of this information by anyone other than the Customer for any purpose other than that for which it is intended is not authorized; and, with respect to l

unauthorized use, GE Nuclear Energy makes no representation or warranty and assumes no

[

liability as to the completeness, accuracy, or usefulness of the information contained in this document.

4 i

a L

GENE-A00-04021-01' TABLE OF CONTENTS-Section Iitic Eags LIST OF TABLES iv LIST OF FIGURES v

ABSTRACT vi 1

INTRODUCTION 1-1 1.1 Historical Perspective 1-1 1.2 BWR Owners' Group Response 1-2 1.3 Option I-D Solution 1-2 1.4 Applicability of Option I-D to Duane Arnold 1-4 2

SUMMARY

AND CONCLUSIONS 2-1 3

APPLICATION OF BWROG STABILITY LONG-TERM SOLUTION REGIONAL EXCLUSION METHODOLOGY 3-1 3.1 Void Coefficient 3-1 3.2 Thermal-hydraulic Data 3-1 3.3 Hot-channel Axial Power Distribution 3-1 3.4 Average-channel Axial Power Distribution 3-2 3.5 Radial Power Distribution 3-3 3.6 Pellet-clad Gap Conductance 3-3 3.7 Miscellaneous Input Values 3-3 4

REGIONAL EXCLUSION RESULTS 4-1 5

APPLICATION OF BWROG STABILITY LONG-TERM SOLUTION DETECT AND SUPPRESS METHODOLOGY 5-1 5.1 Licensing Compliance 5-1 5.2 Methodology Overview 5-1 5.2.1 Pre-Oscillation MCPR 5-2 5.2.2 Statistical Calculation of Hot Bundle Oscillation Magnitude 5-3 5.2.3 MCPR Performance of the Hot Bundle 5-5 5.3 Final MCPR Calculation 5-5 ii

1

\\

GENE-A00-04021-01 TABLE OF CONTENTS (continued)

,Inig Egg Section B

6 DETECT AND SUPPRESS RESULTS 6-1 6.1 Statistical Model Calculation 6-1 6.2 Final MCPR Calculation 6-4 7

RELOAD APPLICATION 7-1 8

REFERENCES 8-1 4

4 d

1 4

4 i

iii i

t GENE-A00-04021-01 LIST OF TABLES Inbh

. Title Eage

~

4-1 Analysis State Points on Operating Map 4-2 7

4-2 Coordinates of Exclusion Region Boundary 4-3 5-1 LPRM-to-APRM Assignment Logic 5-4 5

6-1 DAEC Cycle 14 Inputs for Hot Bundle Oscillation Magnitude Calculation 6-1 4

6-2 Highest 50 Trials for DAEC Cycle 14 Hot Bundle Oscillation Magnitude Calculation 6-2 I

7-1 Parameters for Reload Review Evaluation 7-1 4

J p

1 1

IV

t GENE-A00-04021-01 LIST OF FIGURES figurn Iida P. age l-1 Typical Exclusion Region in Operating Map 1-3 2-1 Duane Arnold Exclusion Region (Cycle 14) 2-1 4

3-1 Hot-channel Axial Power Profiles 3-2 3-2 Average-channel Axial Power Profiles 3-3

'4-1 Analysis State Points on Operating Map 4-1 4-2 Coordinates of Analysis State Points on Stability

~

Criterion Map 4-2 4-3 Duane Arnold Exclusion Region (Cycle 14) 4-4 5-1 Fixed DIVOM Curve for Core-Wide Mode Oscillations 5-6 a

a W

V

t GENE-A00-04021-01 ABSTRACT This report demonstrates the application of the " Regional Exclusion with Flow-Biased APRM Neutron Flux Scram" Stability Solution (Option I-D) of the "BWR Owners' Group Stability.

Long-term Solutions Licensing Methodology" to the Cycle 14 as-loaded-core of the Duane Arnold Energy Center, in compliance with General Design Criterion 12. An Exclusion Region is presented for the plant which identifies plant conditions that may lead to an instability. The Exclusion Region analysis shows that the large single-phase pressure drops induced by the relatively small inlet orifices of DAEC creates a preference for core-wide mode oscillations should the plant maneuver into the conditions susceptible to a reactor instability. The Exclusion Region analysis concludes that regional mode oscillations are not anticipated to occur for DAEC.

In addition, a statistically based Detect and Suppress analysis is performed to demonstrate protection of the fuel Minimum Critical Power Ratio (MCPR) Safety Limit from the flow-biased APRM neutron flux trip. The Detect and Suppress analysis is performed for core-wide mode oscillations only, consistent with the Detect and Suppress licensing methodology documented to the NRC in NEDO-32465, May 1995.

i 4

Vi

.t p

.i GENE-A00-04021-01 i

1 INTRODUCTION This report demonstrates the application of the " Regional Exclusion with Flow-Biased APRM i-Neutron Flux Scram" Stability Solution (Option I-D) to the Duane Arnold Energy Center (DAEC) as prescribed by the BWR Owners' Group Long-term Stability Solutions Licensing Methodology.2) -

j p

This solution creates an " Exclusion Region" in the plant operating map i

wherein' oscillatory power behavior is conservatively predicted to be possible and which is avoided durmg plant operations. The Exclusion Region analysis also confirms that core-wide

[

reactor instability is the predominate mode and regional mode oscillations are not expected to occur for DAEC. The protection of the Safety Limit Minimum Critical Power Ratio (SLMCPR) f afforded by the flow-biased Average Power Range Monitor (APRM) neutron flux trip is demonstrated for. the preferred core-wide mode of coupled thermal-hydraulic /neutronic i

oscillations for DAEC.

1 4'

I 1.1 HistoricalPerspective i

Protection against power oscillations that might lead to fuel damage has been required by j

General Design Criterion 12 ), which requires that such oscillations either not be possible or be 13 reliably detected and suppressed.

In the past, this requirement was met by showing that i

oscillations are not possible by calculating core and channel decay ratios as a part of reload J

j licensing analyses. Such results notwithstanding, guidance was provided to BWR operators as early as 1982 in the form of a GE Service Information LetterI41 on the detection and suppression of hypothetical power oscillations at low-flow and high-power conditions.

With the advent of 8X8 fuel designs and more aggressive operating strategies to improve operational flexibility and fuel utilization (e.g., extended load lines, feedwater heaters out-of-4 service, etc.), stability margins decreased such that instabilities could no longer be demonstrated l

to be impossible; therefore, in 1982 and after, protection against power oscillations was ensured by providing plant operators with guidance on detecting and suppressing such oscillations *#1. In l

[

addition, analysis was performed to demonstrate that the occurrence of such os:illations did not challenge fuel thermal-mechanical limits ".

l 1

i Additional concerns about BWR stability were raised by the March 9,1988, oscillation event at i

the LaSalle-2 plant, when investigations revealed that power oscillations could occur more rapidly than had been thought probable. Furthennore, new analyses predicted less margin to the

_ SLMCPR than was previously shown ). This event led NRC to issue Bulletin 88-07, which ts PI requires BWR owners to indicate how they would guard against such events in the future.

4 1

t 4

GENE-A00-04021-01 1.2 BWR Owners' Group Response In response to NRC Bulletin 88-07, the BWR Owners' Group, in conjunction with GE, implemented a program to develop a long-term solution to the stability issue. The BWROG approach, as well as interim protective guidelines, was accepted by the NRC in Supplement I to the aforementioned BulletinD 1. The BWROG efforts led to generation of the "BWR Owners' Group Long-term Stability Solutions Licensing Methodology,"UI which outlines several solution options. Some of these involve the introduction of a new Reactor Protection System (RPS) trip function and may be applied to all BWR's, while others demonstrate the adequacy of existing hardware but are applicable to only a limited set of plants.

1.3 Option I-D Solution One of the solutions which demonstrates the adequacy of existing hardware is Option I-D, entitled, " Regional Exclusion with Flow-Biased APRM Neutron Flux Scram." This solution consists of two parts. The first is the creation of an Exclusion Region in the operating map for the plant (Figure 1-1). This is a region where conservative decay ratio calculations indicate that power oscillations are possible. If the plant should enter this region due to a flow reduction event, such as a recirculation pump trip or runback, or due to a power increase at low flow, the operators are instructed to promptly exit the region and initiate a manual scram if oscillations occur. As a part of the generation of the Exclusion Region, the margin to regional mode DI oscillations is quantified using the methodology identified in Supplement I to NEDO-31960.

As described therein (Section 5.0), there are unrealized conservatisms in the prediction of the already low likelihood of regional mode oscillations by neglecting the higher eigenvalue separation for the small core size of DAEC.

The second part of this solution is a demonstration that, even in the unlikely event of a power oscillation, an APRM flow-biased flux trip will detect and suppress the most probable mode a

power oscillations (core-wide mode) before the SLMCPR is reached. This demonstration uses t2 the statistical methodology described in NEDO-32465 ) It is conservatively applied for core-wide mode oscillations both in terms of the inputs and confidence levels used in the statistical methodology.

f I-2

l t

l' GENE-A00-04021-01 4

While the Exclusion Region and MCPR analysis are the components of the Option I-D solution which are analytically demonstrated, they are not, in and of themselves, the complete solution.

Recognizing that highly skewed axial power shapes reduce margin to the onset reactor instability, an on-line stability predictor and administrative controls are being added to DAEC by the licensee. Therefore, the analytical demonstrations are part of a hierarchy of barriers that provide a high degree of assurance that fuel thermal limits cannot be approached. The barriers that must be scaled before fuel limits can be approached may be summarized as:

. Occurrence of a transient that brings the plant into the Exclusion Region (e.g., recirculation pump trip, recirculation pump runback, inadvertent control rod withdrawal or loss of feedwater heating during startup).

. Failure to leave the Exclusion Region either by increasing flow or decreasing power (It las been observed that an appreciable time lapse occurs before the system stabilizes at the new operating point and that oscillations require some time to evolve: there is adequate time for the operators to maneuver the plant out of the Exclusion Region or to scram the plant upon recognition of an oscillation.).

. Development of oscillatory power '.sehavior outside of the expected statistical occurrence for which a RPS trip does not occur before fuel thermal limits are exceeded.

Figure 1-1. Typical Exclusion Region in Operating Map 120 -

100 Analytically Determined Region Boundary o 80 -

6 60 --

Exclusion Region n.

40 20 +

o 0

20 40 60 80 100 120 Core Flow (% of Rated) 1-3

~. -..

l t

' ^

GENE-A00-04021-01 1.4 Applicability of Option I-D to Duane Arnold Integral to the Option I-D approach is the assertion that regional mode oscillations have a low

}

probability of occurrence. One feature of DAEC that assists in protecting against the occurrence of regional mode oscillations is that there are large single-phase channel pressure losses when 1

compared to other BWR's. Such losses, in the absence of other changes in core hydraulic characteristics, are known to be stabilizing. When comparing various plant desip, differences j

in single-phase pressure losses are mostly attributable to the fuel inlet orifices; thus, plants, such 7

as DAEC, which have relatively small inlet orifice diameters, are expected to be more stable than j.

those with larger inlet orifice diameters (the inlet orifice diameter for DAEC is 2.09 inches as compared to 2.43 inches for most other BWR 4's and 5's) and less likely to excite higher harmonic modes of reactor instability.

I s

i

. A second feature is that the core is relatively "small." Since the phenomenon underlying the neutronic portion of regional mode oscillations is the excitation of the higher harmonic modes of L

the fundamental (i.e., critical) flux shape, the occurrence of region mode oscillations requires the i

insertion of sufficient reactivity to overcome the inherent sub-critical multiplication of those j

3 modes (i.e., "eigenvalue separation"). The eigenvalue separation has been found to be strongly i

dependent on the size of the core, with smaller cores (e.g.,368 bundles) having markedly greater l

separation than larger cores (e.g.,764 bundles). Nevertheless, the current analysis conservatively neglects eigenvalue separation and relies wholly on the larger hydraulic losses of the inlet orifices to demonstrate a preference for the core-wide mode of oscillation.

i 2

A third feature in the application of Option I-D is that DAEC has an unfiltered APRM flow-i biased flux trip instead of a Simulated Thermal Power Monitor (STPM). The APRM neutron i

flux signal provides an instantaneous response to a neutron flux change rather than the slower fuel thermal response associated with a STPM. The assertion for a small core such as DAEC is that (1) a core-wide mode oscillation will be excited long before an azimuthal (regional mode) oscillation, and (2) the APRM flow-biased flux trip will suppress the oscillations before a thermal limit is reached (the MCPR limit is the most sensitive thermal limit for oscillations).

+

t 1

T 4

J P.

t GENE-A00-04021-01 2

SUMMARY

AND CONCLUSIONS Compliance with deneral Design Criterion 12 is demonstrated with the Regional Exclusion with Flow-biased APRM Neutron Flux Scram Stability Solution (Option I-D) for the Cycle 14 as-f loaded-core of the Duane Arnold Energy Center.

The Exclusion Region for the Cycle 14 as-loaded-core of AeC is shown in Figure 2-1. The analysis confirms that core-wide mode oscillations are the preferred mode for DAEC primarily due to the relatively small fuel inlet orifice size.

Figure 2-1. Duane Arnold Exclusion Region (Cycle 14) 120-Core Thermal Power 100-(% of

/

MR wp Rated)

/

80 110%

60 8

ct Exclusion Region 40 V,

J 20 i

/

0 0

20 40 60 80 100 120 Core Flow (% of Rated) 2-1

t

\\

GENE-A00-04021-01 Protection of the Safety Limit Minimum Critical Power Ratio (SLMCPR) is demonstrated for core-wide mode or,cillations on the rated flow-control line in accordance with the statistical t21 methodology defined in NEDO-32465. Therefore, the flow-biased APRM neutron flux trip provides protection of the fuel SLMCPR against the preferred mode of oscillation with high statistical confidence for Cycle 14.

Results of this demonstration for Cycle 14 are expected to be applicable to future reload cycles due to the use of conservative inputs and assumptions. However, it is appropriate to confirm applicability of the specific inputs and conditions identif ed in Section 7 for subsequent reload designs on a cycle-by-cycle basis.

l l

L 2-2

-=

t

\\

GENE-A00-04021-01 3 APPLICATION OF BWROG STABILITY LONG-TERM SOLUTION REGIONAL EXCLUSION METHODOLOGY i

Section 3 describes the application of the BWROG Regional Exclusion Methodology for DAEC.

This application is intended to define the power flow conditions to be avoided during normal l

operation. Also, the results of this analysis conservatively verify that the core-wide mode of reactor instability is the preferred mode for DAEC. The analysis inputs described below for the l

demonstration application were developed for the Cycle 14 as-loaded-core. Future operating cycle reload analysis will confirm the applicability of the power flow map Exclusion Region and J

preference for core-wide mode oscillations to the particular characteristics of the new fuel cycle.

Ihe algorithm used to define the Exclusion Region is based on the FABLF/BYPSS methodology -

l and the inputs to it are as described in Section 5.2 of the BWROG methodology report"I. Input 1

parameters that are dependent upon cycle specific parameters, such as fuel loading, are from l

Cycle 14 for DAEC. As such, the Exclusion Region is specific to Cycle 14 and its validity must be confirmed for each subsequent fuel reload.

I j

3.1 Void Coefficient 4

Void-feedback parameters (nuclear void coefficient and delayed neutron data) are chosen from 1

the exposure point in Cycle 14 for which void coefficient is most negative. 0+her inputs to the j

methodology (e.g., axial power distribution) are not from the same exposure point, but use of the l

most limiting void-feedback parameter values is conservative.

3.2 Thermal-bydraulic Data Standard design values for DAEC, consistent with the FABLE /BYPSS qualification bases, are j

used in the analysis.

6 3.3 Hot-Channel Axial Power Distribution I

Channel hydraulic stability is known to be strongly affected by the channel's axial power

)

distribution. For the hot channels, the axial power distribution is fixed by the procedure to be j

peaked near the bottom of the channel, a distribution that is known to be less stable. These axial

. power distributions for both forced flow and natural circulation are shown in Figure 3-1. These axial profiles are consistent with those shown in Figure 5-5 of the BWROG Methodology reportDI. Hot channels are identified for each hydraulic channel design in the DAEC core.

i 3-1

i

\\

GENE-A00-04021-01 Figure 3-1 Hot channel Axial Power Profiles 2.00.

1.80 +

1.60.

1. O em 1.00.

f 0.80 hy 0.00 1 2 3 4 5.6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Axial Location

-a-NaturalCrculaton + Forced Flow l 3.4 Average-Channel AxialPowerDistribution Core stability is known to be affected by the axial power distribution of the bulk of the channels in the core (all those other than the " hot channels"). In the absence of other changes, a relatively

" flat" axial power distribution will be less stable than top-peaked or bottom-peaked distributions; therefore, for forced circulation conditions, the Haling End-of-Cycle 14 (EOC-14) full power and flow core-average axial power distribution is used (see Figure 3-2). For natural circulation conditions, the power distribution moves strongly to the bottom of the core and use of a Haling profile characteristic of full power and flow would be too conservative; therefore, a core-average axial power distribution characteristic of natural circulation flow at the Haling EOC-14 exposure point is used. The axial power profile at the intersection of the rated flow-control line (FCL) and the natural circulation flow line is shown in Figure 3-2.

3-2

t i

GENE-A00-04021-01 Figure 3-2 Average-channel Axial Power Profiles 1.60.

/M 1.40.

1.20.

,4.,3 us,

- m y

{. /

N, I ~;

~.~,,N Q.

0.40 ! !/

0.20 0.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Axial Location

-e-. Natural Crculadon + Forced Flow 3.5 RadialPowerDistribution The radial peaking factors for the channel grouping used in the FABLE /BYPSS analyses are based on those obtained from the GE 3D BWR Simulator CodeUU. The values chosen are from the EOC-14 Haling exposure point.

3.6 Pellet-Clad Gap Conductance 4

Core average pellet-clad gap conductances were determined for each fuel design using the approved fuel licensing model consistent with the FABLE /BYPSS qualification bases.

3.7 Miscellaneous Input Values Other input values to the FABLE /BYPSS analyses, such as heat balance data, recirculation loop resistance, fuel physical parameters and material properties are standaru design values for DAEC. It is assumed that the nominal heat balance assumptions, such as the operation of all feedsvater heaters, are valid for this model.

3-3

t GENE-A00-04021-01 4 REGIONALEXCLUSIONRESULTS Core and channel decay ratios were calculated for two power flow combinations on the operating map (see Figure 4-1) using the inputs described in Section 3. The purpose of this analysis is to verify the location of the Exclusion Region boundary on the power flow map for the Cycle 14 as-loaded-core and verify that core-wide is the preferred mode of oscillation for DAEC. The boundary definition and margin to regional mode instability are established using the generic BWROG Stability Criterion Map.

Figure 4-1. Analysis State Points on Operating Map 120 --

Core

+ Analysis State-Points 100 +

APRM Trip Power

(% of Rated) 110'V CL 60 +

/V 40 --

/

20 --

0 0

20 40 60 80 100 120 Core Flow (% of Rated)

The points calculated are provided in Table 4-1. Point A is along the 120% flow-control line and Point B is along the natural circulation line. The core and channel decay ratio results of the analyzed points are tabulated in Table 4-1.

l 4-1

t GENE-A00-04021-01 4

Table 4-1. Analysis State Points on Operating Map

' State Power Flow Channel Hydraulic Core Decay Symbol on Point

(%)

(%)

Decay Ratio Ratio Figure 4-2 A

66.2 39.3 0.27 0.79 3

B 40.4 30.0 0.29 0.80 X

The points shown in Figure 4-1 and provided in Table 4-1 are plotted on the generic BWROG Stability Criterion Map in Figure 4-2. The plotting symbols have been prosided in Table 4-1 for clarification. The_ power and flow conditions of the state points were chosen such that the st6i'ity map criterion are met. These power and flow conditions provide the coordinates of the endpoints of the exclusion region boundary.

i Figure 4-2. Coordinates of Analysis State Points on Stability Criterion Map 1.4 -

)

Core 1.2 -.

Decay i

Ratio 3.,_

4 Margin to Regional Mode Oscillations 0.8 0.6 --

O.4.

0.2 --

0 O

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

Channel Hydraulic Decay Ratio 4-2 l

t

\\

GENE-A00-04021-01 The coordinates of the analysis state points on the generic BWROG Stability Criterion Map, Figure 4-2, provide further evidence that regional mode oscillations are not probable for DAEC.

It was shown in the stability solutions licensing methodology reportN that the probability of regional mode oscillations becomes progressively smaller as channel hydraulic decay ratio is decreased, and regional mode oscillations have not been observed for channel hydraulic decay 4

ratios less than 0.6. The largest channel hydraulic decay ratio conservatively predicted by the methodology for DAEC is 0.29 and occurs at the intersection of the natural circulation flow line and the Exclusion Region boundary. Regional mode oscillations are not anticipated anywhere on the operating map for DAEC because of this large margin.

The points identified in Table 4-1 are then used to determine the location of the Exclusion i

Region boundary, which is shown in Figure 4-3. The Exclusion Region boundary for DAEC is specified by the boundary shape function equation which has been validated against previous Option I-D plant-specific region boundary calculations. The equation for the boundary is as follows:

1 W-W, ( W W, [

P=Pg

-W,4,kW,4,) -

'P l

A s Pas

where, P = a core thermal power value on the Exclusion Region boundary (% of rated),

W = the core flow rate corresponding to power, P, on the Exclusion Region boundary

(% of rated),

P = core thermal power at State Point A (% of rated),

A P = core thermal power at State Point B (% of rated),

3 W = core flow rate at State Point A (% of rated),

4 W = core flow rate at State Point B (% of rated),

3 The range of validity of the fit is:

30.0 < W < 39.3.

4-3

GENE-A00-04021-01 Figure 4-3. Duane Arnold Exclusion Region (Cycle 14) 120-Core Thermal Power 100-(% of

[

y 9

Rated) 80 110 CL 60 CL Exclusion Region

-40 l

/

20 0

0 20 40 60 80 100 120 Core Flow (% of Rated) 4-4 1

l

t GENE-A00-04021-01 5 APPLICATION OF BWROG STABILITY LONG-TERM SOLUTION DETECT AND SUPPRESS METHODOLOGY 5.1 LICENSING COMPLIANCE Section 5 describes the application to DAEC Cycle 14 of the Detect and Suppress portion of stability long-term solution Option 1-D.

This application demonstrates protection of the SLMCPR provided by the flow-biased APRM neutron flux trip for core-wide mode oscillations.

The Detect and Suppress licensing methodology for application te Oplon 1-D is documented in t21 BWROG Licensing Topical Report NEDO-32465. Consistent with DAEC qualification as an Option I-D solution plant, the Regional Exclusion methodology demonstrates that core-wide is the predominate oscillation mode and, therefore, the Detect and Suppress calculation must only be performed for core-wide mode oscillations, i

The Detect and Suppress methodology ) assumes that a core-wide mode oscillation occurs, and t2 is terminated by automatic reactor scram when the APRM oscillation magnitude reaches the flow-biased APRM flux trip. The methodology applies a statistical method, using a combination of statistical and deterministic inputs, to determine the final MCPR (FMCPR) with a high j

statistical confidence when control rod insertion disrupts the oscillation. The flow-biased APRM flux trip provides adequate protection as long as the FMCPR is greater than the SLMCPR.

5.2 METHODOLOGY OVERVIEW The Detect and Suppress methodology is used to detennine the FMCPR resulting from core-wide mode oscillations which are terminated by the APRM flow-biased scram. The rated flow-control line is used to define the plant conditions for application of the methodology. The methodology consists of three major components:

Calculation of the Pre-Oscillation MCPR: A DAEC Cycle 14-specific determination a.

of the MCPR on the rated flow-control line captures the margin to the SLMCPR prior to the oscillation. This is known as the initial MCPR (IMCPR). The IMCPR is calculated conservatively assummg the plant is initially operating at the MCPR operating limit (OLMCPR).

b. Statistical Calculation of Peak Oscillation Magnitude: A statistical evaluation of the i

normalized peak oscillation magnitude, Ah (defined as oscillation (peak-minimum)/ average), due to an oscillation initiating on the rated flow-control hne captures the effect of plant characteristics, trip system definition, and setpoint values on the peak fuel bundle power oscillation magnitude. The statistical methodology considers power distributions, oscillation contours, oscillation growth rates, 5-1

i GENE-A00-04021-01 L

oscillation frequencies, trip overshoot, LPRM failures, and APRM failures. The result of the evaluation is a statistically conservative value of the peak hot bundle oscillation magnitude, Ah ms, at a 95% probability and 95% confidence level for 9

anticipated reactorinstability.

c. MCPR Performance of the Hot Bundle: A relationship between the fractional change in CPR and the hot bundle oscillation magnitude for core-wide mode oscillations captures the effect of fuel design. The relationship has been derived from 3-D TRACG analyses performed over a range of conditions and conservatively represents -

current DAEC loaded fuel designs.-

4 The IMCPR'and oscillation magnitude calculations are both evaluated at the rated flow-control line. Additional conservatisms have been added to the methodology to streamline the reload review process. A relatively simple confirmation of the applicability of each portion of the L DAEC Cycle 14 Detect and Suppress calculation is all that will be required for subsequent fuel cycles to assure with a high confidence that the RPS trip setpciints continue to provide protection of the SLMCPR for anticipated reactor instability. If the applicability of a portion of the calculation cannot be assured, then specific portions of the calculation would need to be re-performed.

Further information on application of each of the three portions of the methodology to DAEC l

Cycle 14 is provided in the following.

5.2.1 PRE-OSCILLATION MCPR The IMCPR is the more limiting (lower) of the MCPR from two scenarios on the rated flow-control line. The two scenarios evaluated are (1) a two recirculation pump trip from rated flow with the MCPR at the OLMCPR, and (2) steady-state operation at 45% core flow at the applicable flow-dependent OLMCPR.

5.2.1.1 Two Recirculation Pump Trip For DAEC Cycle 14, the lowest OLMCPR is 1.20 'I. Flow runback analysis 0

completed on the rated flow-control line with the 3D core simulator determined that the CPR increase due to the flow runback from rated flow to natural circulation is 0.373.

Therefore, the IMCPR for Condition 1 is:

IMCPR = 1.20 + 0.373 = 1.573 i

5-2

t GENE-A00-04021-01 5.2.1.2 Steady-State Operation at 45% Core Flow For DAEC Cycle 14, The OLMCPR on the rated flow-control line at 45% flow is computed from the flow-dependent MCPR limits for DAEC Cycle 14U3I, resulting in:

IMCPR = 1.40 2

5.2.1.3 LimitingIMCPR The IMCPR is the more limiting (lower) ofIMCPR and IMCPR :

i 2

IMCPR = Min [IMCPR,IMCPR ] = 1.40 i

2 5.2.2 STATISTICAL CALCULATION OF HOT BUNDLE OSCILLATION MAGNITUDE A

The statistical model is described in BWROG Licensing Topical Report NEDO-32465. The model c?lculates hot bundle oscillation magnitude, Ah, dependent on a combination of statistical inputs and deterministic plant-specific factors. The statistical model results in selection of a conservative value of the hot bundle oscillation magnitude, Ah s5, at the 95% probability with a 95 95% confidence level.

5.2.2.1 StatisticalInputs Growth Rate: A review of actual instability events indicates that most BWR oscillations would be expected to have a growth rate only slightly above 1.00. For DAEC application, the growth rate is randomly selected from the probability density function 2

with a x distribution shown in Ref. 2.

Overshoot: The trip setpoint overshoot is a measure of how much an oscillation exceeds the trip setpoint. The overshoot is the fre.ction of the peak-to-peak difference between two consecutive cycles which is above the setpoint, when a trip occurs. Thus,0.0 s S s 1.0; and the value of S can be considered to be essentially random. For DAEC application, the overshoot is randomly selected from the uniform distribution shown in Ref. 2.

Oscillation Period: The statistical methodology considers a range of oscillation periods.

Studies of actual instability events indicate that the expected value for the period is approximately 1.8 to 2.0 seconds. However, it is desirable to consider an oscillation frequency range between 0.7 Hz and 0.3 Hz. This corresponds to a desired period range of 1.4 sec 5 T 5 3.3 sec. For DAEC application, the oscillation period is randomly selected from the probability density function with a x distribution shown in Ref. 2.

2 LPRM Failures: The statistical model provides options for considering an input LPRM failure probability distribution, a fixed failure percentage, or no LPRM failures in the calculation of hot bundle oscillation magnitude. For DAEC application, a random number of LPRM failures are selected from the distribution specified in Ref. 2 which is 5-3

)

t GENE-A00-04021-01 representative of plant data on LPRM failure rates. The specific LPRMs which are defined to fail for a given trial are then randomly selected from the total DAEC LPRM population.

\\

Oscillation Contouts: The statistical model randomly seleets from the specified set of

)

oscillation contourz DAEC application uses plant-specific contours developed for core-wide mode oscillations, l

5.2.2.2 DeterministicInputs LPRM Assignments: Option 1-D relies on the APRM flow-biased trip. LPRMs are assigned to their respective APRM channels ac :ording to the plant configuration. All non-failed LPRM signals in an APRM are used to produce an averaged power signal for comparison to the trip setpoint. DAEC was designed with 80 LPRMs, in 6 APRM channels. However, the "D" level detectors in LPRM strings 40-25 and 24-09 have been removedit41 (both were in APRM Channel E). Therefore, there are 78 remaining LPRMs in the DAEC core. In the DAEC design, the LPRMs assigned to Channel A are also assigned to Channel B, and the LPRMs assigned to Channel C are also assigned to Channel D, as illustrated in Table 5-1. The LPRMs in Channels E and F are not assigned to any other channels I. Since there are channel pairs with identical LPRMs, DAEC I

normally operates with either Channels A & D bypassed, or with Channels B & C bypassed as illustrated in Table 5-1. For stability trip applications, there is no difference between the two operational configurations.

{

Table 5-1. LPRM-to-APRM Assignment Logic Division APRM LPRM Operational (Not Bypassed)

I A

group 1 yes I

C group 2 yes E

group 3 yes yes B

group 1 yes II-D group 2 yes j

F group 4 yes yes i

Trip Setpoint: The nominal APRM trip setpoint is input as a percentage of rated power.

{.

At natural circulation, the flow-biased APRM trip is at 62% reactor power 'I.

U Radial Peaking Factor: Since only the fundamental mode from the 3-D BWR simulator j

is used to calculate the relative LPRM signal averages, A, there is only one hot bundle in l

. the core-wide mode oscillation. This bundle is also the "true" hot bundle with the highest l

radial peaking factor. Its normalized oscillation magnitude, Ah, is the same as any other

-location in the core. The radial peaking factor used for DAEC is 1.44U43 j

RPS Trip Logic: DAEC has a one-out-of-two, taken twice trip logic. Therefore, at least one channel from Division I and at least one channel from Division II must reach the

. APRM trip setpoint for the trip signal to be generated.

j i

5-4 i

~...

.t 1

GENE-A00-04021-01 j

).

APRM Channel Failure: In addition to the failure ofindividual LPRMs, the failure of

[

one APRM channel is considered. The model provides several options: no APRM channel failure, failure of a specified channel, failure of a randomly selected channel, and -

l failure of tiie most responsive channel. For conservatism, the failure of the most i

j responsive channel (i.e., the first channel to reach the trip setpoint) is used for Option 1-D analysis.

4 Delay Time: The delay time for control rod insertion to terminate oscillation growth is input to the model. The time at which the reactor trip criterion is reached plus the delay time sets the time window in which the peak hot bundle oscillation magnitude can occur.

The delay time is a plant-specific input consisting of the APRM response time (20 msec),

}

the RPS processing time (50 msec), the control rod drive delay time before rod motion i

begins (200 msec), and the time for control rods to insert two (2) feet into the core i

assuming control rods insert at the muumum scram speed allowed by the plant Technical

{

Specifications (615 msec). Even though control rod insertion two feet into the core will l

not shut the reactor down, it isjudged to be adequate to prevent fiuther growth of the hot bundle oscillation. Therefore, the total delay time for DAEC Cycle 14 is 885 msec.

t t

p l

5.2.3 MCPR PERFORMANCE OF THE HOT BUNDLE The relationship of change in CPR as a function of oscillation magnitude has been designated as the DIVOM curve (Delta CPR over Initial CPR Vs. Oscillation Magnitude). Application to DI

{.

Option I-D uses the generic DIVOM curve for core-wide mode oscillations, which is the same 1

as the fixed DIVOM curve previously specified for Option 1-D application. The equation of the t

fixed curve is [ACPR/IMCPR = 0.175

  • Ah ss + 0.05). The specified fixed curve is shown in l

95 Figure 5-1.

i i

The generic DIVOM curve for core-wide mode oscillations is reasonably conservative (but not l

necessarily bounding in all cases) when compared to the TRACG CPR performance data. It is i

W very conservative for application in the licensing methodology since using a nominal value for j

the slope of the generic DIVOM curve with the Ah ss hot bundle oscillation magnitude would 95 produce a FMCPR at approximately the 95/95 level.

i

)

5.3 FINAL MCPR CALCULATION The three-parts of the Detect and Suppress methodology provides for a conservative calculation of the minimum MCPR for an anticipated stability-related oscillation. First, the initial MCPR (IMCPR) is determined by a cycle-specific evaluation at the rated flow-control line. Next, the L

hot bundle oscillation magnitude (Ah ss) is calculated at the rated flow-control line. Finally, the 95 t

i i

5-5 l-

.l

l' GENE-A00-04021-01 MCPR change (ACPR/IMCPR) corresponding to Ah is determined. From these three 95/95 elements, the final MCPR (FMCPR) can be determined:

FMCPR =IMCPR - IMCPR * {ACPR/IMCPR}

where:

{ACPR/IMCPR} =

determined from generic DIVOM curve at the

'specified (P-M)/A 95/95 oscillation magnitude.

The licensing criterion is met when the FMCPR is greater than the SLMCPR. For DAEC Cycle 14,the SLMCPRis 1.07U31 Figure 5-1. Fixed DIVOM Curve for Core Wide Mode Oscillations O.4

,/

Eixed DIVOM Curve

/

o-

,/

,/

/

j f'

O.2

,/

7

/

Approximation to Curve in Figure A-16 oi NEDO-31960 p

s' s

0.1

,s'

/

.s O

O 0.5 1

1.5 2

2.5 Oscillation Magnitude, (P-M)/A l

5-6

GENE-A00-04021-01 t

6 DETECT AND SUPPRESS RESULTS 6.1 STATISTICAL MODEL CALCULATION The statistical methodology consists of a 1000-trial Monte Carlo analysis. Based on non-

}

parametric tolerance limits, the methodology rank orders the 1000 trials'and selects the 39* trial

[

W from the end as the 95/95 value. A 1000-trial statistical analysis has been calculated for DAEC I

Cycle 14. Table 6-1 lists the key inputs.- Table 6-2 provides the highest 50 calculated values of hot bundle oscillation magnitude (Ah) and the 95/95 value (Ah ss = 0.708).

95 Table 6-1: DAEC Cycle 14 Inputs for Hot Bundle Oscillation Magnitude Calculation

- Core Size:

368-bundle core Trip System:

Flow-biased APRM Trip Logic:

One-out-of two, taken twice Oscillation Mode:

Core-wide APRM ChannelFailure:

Most Responsive APRM Channel (applied to 100.0% of all trials)

LPRM Failures:

Random (x' Distribution)

Oscillation Period, T:

Random (X' Distribution)

Growth Rate, Gr:

Random (x'Diwribution) l Overshoot,6:

Random (Unifonn Distribution)

Average Reactor Power:

48.0 % rated (100% rod line at natural circulation)

RadialPeaking Factor:

1.440 APRM Trip Level (nominal): 62.0 % rated (at natural circulation)

Total Delay Time:

885 msec. (measured from time of full trip)

TotalNumber of LPRMs:

78 Oscillation Contour Selection: Random from contours: KElB10AH1, KElB10AH3, KEIM10AH1, i

KEIM10AH3, KElE10AHi, KElE10AH3, KElH10AH1, KElH10AH3 i

\\

d i

i.

l l

6-1 m

m m

GENE-A00-04021-01 Table 6-2: Highest 50 Trials for DAEC Cycle 14 Hot Bundle Oscillation Magmitude Calculation Contour Period, T APRM

  1. LPRM

% LPRM Hot Bendte Peak Power Trial #

ID (sec)

GR Overshoot Failure Failures Failures OM

(% rated) 812 KEIM10AH3 2.49 1.22 0.64 F

7

- 9.0 0.702 97.15 377 KEIMIDAII3 2.69 1.13 0.06 F

4 5.1 0.702 '

97.19 930 KElll10AII3 1.70 1.13 0.97 F

10 12.8 0.703 97.23 698 KElll10AII3 1.49-1.16 0.84 F

5 6.4 0.704 9,7.26 483 KEllll0Allt 2.57 1.14 0.93 F

5 6.4 0.704 -

97.29 733 KEIB10Alli 1.94 1.22 0.72 F

2 2.6 0.705 97.28 924 KEIE10 AID 2.20 1.12 0.10 F

12 15.4 0.705 97.31 624 KElll10All3 2.68 1.17 0.78 F

7 9.0 0.705 97.34 548 KElll10Alli 1.73 1.14 0.94 F

7

. 9.0 0.706 97.34 618 KElBl0AII3 1.47 1.24 0.67 F

6 7.7 0.706 97.34 678 KElll10All) 2.65 1.33 0.47 F

18 23.1 0.708 97.42 25 KElB10AHI 1.96 1.19 0.86 F

4 5.1 0.708 97.44 39* trini froni end: Hot Bundle (P-M)/A 95/95, Ah95/95 = 0.708 200 KEIM10AII3 1.91 1.18 0.83 F

3

'3.8 0.708 97.44 501 KEIEIOAll3 2.20 1.19 0.74 F

2 2.6 0.709 97.49 978 KElBIDAlli 1.50 1.21 0.82 F

10 12.8 0.711 97.57 356 KEIE10Allt 1.45 1.16 0.91 A

4 5.1 0.713 97.66 105 KElM10Alli 2.02 1.19 0.85 D

9 11.5 0.713 97.65 556 KElB10Allt 2.52 1.18 0.96 F

7 9.0 01~3 97.67 93 KElll10AIII 2.40 1.15 0.95 F

4 5.1 0.M4 97.7 482 KEIEI0Alli 2.13 1.16 0.92 F

6 7.7 0.714 97.71 242 KEIEIDAlli 2.15 1.17 0.91 D

7 9.0 0.715 97.75 456 KElBl0Alli 2.02 1.17 0.04 F

6 7.7 0.715,

97.75 116 KElllI0Alli 1.97 1.26 0.60 F

6 7.7 0.715 97.74 l

983 KElB10AII3 2.34 1.22 0.83 F

8 10.3 0.717 97.81 925 KElE10Alli 1.52 1.18 0.86 F

9 11.5 0.718 97.88 648 KElll10Alli 1.71 1.17 0.93 F

2 2.6 0.718 97.9 967 KEIE10All3 1.71 1.15 0.08 A

15 19.2 0.719 97.95 457 KElll10All3 1.72 1.17 0.91 F

8 10.3 0.720 97.97 t

506 KElB10Alli 1.34 1.18 0.00 F

8 10.3 0.720 97.95 681 KElllI0All3 1.47 1.37 0.46 F

6 7.7 0.720 97.97 6-2

GENE-A00-04021-01 Tcble 6-2 (Conti ved)

Contour Period, T APRM

  1. LPRM
  • Hot Bundle Peak Power Trial #

ID (sec)

GR Overshoot Failure Failures Failures OM

(% rated) 629 KElH10AH1 1.74 1.17 0.97 F

5 6.4 0.723 98.12 605 KEIE10Alli 2.40 1.24 0.68 F

4 5.1 0.723 98.13 398 KElll10Alli 2.03 1.21 0.79 F

8 10.3 0.726 98.25 785 KElll10AII3 3.50 1.21 0.81 F

8 10.3 0.727 98.28 819 KEllfiOAlli 1.91 1.22 0.80 E

14 17.9 0.731 98.49 892 KElE10All3 1.36 1.19 0.94 E

3 3.8 0.731 98.5 516 KEIM10Alli 2.21 1.18 0.07 F

8 10.3 0.733 98.56 256 KElBI0Allt.

2.08 1.29 0.73 F

3 3.8 0.734 98.6 864 KEIM10Alli 2.20 1.27 0.73 F

10 12.8 0.736 93.68 64 KEIE10AII3 2.50 1.19 0.98 E

7 9.0 0.736 98.7 293 KEllil0AII3 2.09 1.20 0.98 F

6 7.7 0.746 99.15 773 KEIE10Alli 1.88 1.22 0.89 F

14 17.9 0.746 99.15 262 KEIEl0All3 2.45 1.21 0.96 A

7 9.0 0.748 99.25 866 KEllll0Alli 2.55 1.18 0.11 F

10 12.8 0.75' 99.36 748 KEIB10All3 1.91 1.27 0.90 F

8 10.3 0.758 99.69 440 KElllI0Alll 2.00 1.30 0.75 F

3 3.8 0.759 99.73 68 KElllI0Allt 2.08 1.44 0.62 F

14 17.9 0.784 100.84 402 KElll10All3 2.35 1.29 0.96 A

8 10.3 0.800 101.63 936 KEllll0AII) 1.69 1.36 0.88 F

8 10.3 0.824 102.7 551 KEIE10Alli 1.91 1.41 0.80 F

3 3.8 0.831 103.01 MINIMUM 1.27 1.00 0.00 1.3 0.582 91.9 MAXIMUM 3.67 1.44 1.00 28.2 0.831 103.01 AVERAGE 2.04 1.10 0.49 8.6 0.648 94.79 4

6-3

.I GENE-A00-04021-01 s

6.2 FINAL MCPR CALCULATION First, the initial MCPR (IMCPR) is determined by a cycle-specific evaluation at the rated flow-l controlline.

IMCPR = 1.40 Next, the hot bundle oscillation magnitude (Ah s5) is calculated using the statistical 95 methodology at the rated flow-control line.

Ah ss = 0.708 95 Finally, the MCPR change (ACPR/IMCPR) corresponding to Ah95 S 5 s determined from the generic DIVOM curve for core-wide mode oscillations.

ACPR/IMCPR = 0.175

  • Ah s5 + 0.05 95 ACPR/IMCPR = 0.175 * (0.708) + 0.05 = 0.174 i

From these three elements, the final MCPR (FMCPR) can be determined-i FMCPR = IMCPR - IMCPR * {ACPR/IMCPR}

FMCPR = t.40 - 1.40

  • 0.174 = 1.16 The licensing criterion is met when the FMCPR is greater than the SLMCPR.

FMCPR > SLMCPR 1.16 > 1.07 p

Since the FMCPR is greater than the SLMCPR, the APRM flow-biased trip system shows protection for core-wide mode oscillations.

6-4

= _. _

.= -

t GENE-A00-04021-01 i

l 7 RELOAD APPLICATION i

The purpose of the reload review is to determine the applicability of previous plant-specific calculations to the current fuel cycle. The analysis documented in this report constitutes the 1

baseline for future fuel cycle reload reviews. Table 7-1 tabulates the key parameters which must be evaluated to determine the applicability of the analysis documented herein. If some key parameters do not meet the specified criteria, the applicable portions of the analysis must be re-performed.

+

Table 7-1. Parameters for Reload Review Evaluation 1

Regional Exclusion Methodology l

Description Criteria Base Value l

There are no reactor design changes which No reactor changes

(

would affect the thermal-hydraulic stability of the reactor (e.g., recirculation loop performance)

[

There are no new plant operating modes (e.g.,

No operating region power uprated, increased load lines) which change would affect the operating region of the reactor The reload fuel design has similar stability Similar to GE10 GE10

}

performance as the Cycle 14 fuel design Haling radial peaking factor increases over s 105% ofbase value 1.41 Cycle 14 by no more than 5%

Reload batch size changes by no more than 18 Withinil8 bundles 128 bundles bundles (5% of core size) from the Cycle 14 from base value i

{

batch size i

The Haling cycle exposure changes by no more Within 1080 10,775 MWD /ST i

than 1080 MWD /ST (10% of base value) from MWD /ST from base the Cycle 14 Haling cycle exposure value l

The actual cycle exposure of the previous cycle Within 1050 10,468 MWD /ST I

changes by no more than 1050 MWD /ST (10%

MWD /ST from base of base value) from the Cycle 11 actual cycle value exposure 4

7-1 4

~

~

i i.

p i-GENE-A00-04021-01 Table 7-1. Parameters for Reload Review Evaluation (continued)

Detect and Suppress Methodology Parameter Description Value i

OLMCPR (100/100)

MCPR Operating Limit at rated flow on the 2 1.20 4

rated flow-controlline 4

AMCPR(2RPT)

MCPR increase due to flow runback from a 2 0.373 2RPT l

OLMCPR(100/45)

MCPR Operating Limit at 45% of rated flow on 2 1.40 l

the rated flow-controlline

  1. LPRMs Number ofinstalled LPRMs 2 78-APRM assignment LPRM assignment to APRMs in 6 channels, No APRM design etc.

change APRM trip @ NC Flow-biased APRM trip power level (nominal s 62% rated power value) at natural circulation A @ NC Average power level on the rated flow-control 248% rated power line at natural circulation Tu,y Total delay time (20 msee APRM response s 885 msec j

time,50 msec RPS processing time,200 msec f

delay before start of control rod motion, 615 l

msee for 2 feet of control rod insertion)

Fuel Design Fuel Design which is covered by the Generic GE7, GE8, GE9, 4

l DIVOM Curve for Core-Wide Mode GE10, gel 1, or i

l i

Oscillations GE12

~

l 5

i 4

i l

1 7-2

~

GENE-A00-04021-01 8 REFERENCES

1. "BWR Owners' C,roup Long-Term Stability Solutions Licensing Methodology," NEDO-31960, June 199.. and NEDO-31960 Supplement 1, March 1992.
2. "BWR Owners' Group Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology and Reload Applications," NEDO-32465, May 1995.
3. 10 CFR 50, Appendix A.
4. GE Service Information Letter, SIL-380, Revision 0, August 11,1982.
5. GE Service Information Letter, SIL-380, Revision 1, February 10,1984.
6. NEDE-22277-P, " Compliance of the General Electric Boiling Water Reactor Fuel Designs to Stability Licensing Criteria," December,1982.
7. NEDE-22277-P-1, " Compliance of the General Electric Boiling Water Reactor Fuel Designs to Stability Licensing Criteria," October,1984.

i

8. NEDO-31708, " Fuel nermal Margin during Core Thermal Hydraulic Oscillations in a Boiling Water Reactor," June,1989.
9. NRC Bulletin No. 88-07, " Power Oscillations in Boiling Water Reactors," June 15,1988.
10. NRC Bulletin No. 88-07, Supplement 1, " Power Oscillations in Boiling Water Reactors,"

December 30,1988.

I1. NEDO-30130-A, " Steady State Nuclear Methods," April,1985.

12. NEDE-31917P, "GE11 Compliance with Amendment 22 of NEDE-24011-P-A (GESTAR

]

II)," April,1991.

13. 24A5171, Rev 1," Supplemental Reload Licensing Report for Duane Arnold Energy Center Reload 13 Cycle 14," August 1995.

I i

14. NG-95-2500, Letter RA Browning (IES Utilities) to DW Newkirk (GE), "DAEC Input Data for Detect and Suppress Calculations for Thermal-Hydraulic Stability," August 2,1995.

e 8-1

RTSk2Q7 4tt: chm:nt 2 to tqG-95-3121 General Electric Company AFFIDAVIT I, George B. Stramback, being duly swom, depose and state as follows:

(1) I mn Project Manager, Licensing Services, General Electric Company ("GE") and have been delegated the function of reviewing the information described.in paragraph (2) which is sought to be withheld, and have been authorized to apply for its withholding.

(2) The information sought to be withheld is contained in the GE proprietary report GE-NE-523-A038-0495, ODYSY Description and Qualification, Class 3 (GE Proprietary Information), dated August 1995. The proprietary information is delineated by bars marked in the margin adjacent to the specific material.

(3) In making this application for withholding of proprietary information of which it is the owner, GE relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec. 552(b)(4), and the Trade Secrets Act,18 USC Sec.1905, and NRC regulations' 10 CFR 9.17(a)(4), 2.790(a)(4), and 2.790(d)(1) for " trade secrets and commercial or financial information obtained from a person and privileged or confidential" (Exemption 4). The material for which exemption from disclosure is here sought is all " confidential commercial information", and some portions also qualify under the narrower definition of" trade secret", within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission. 975F2d871 (DC Cir.1992), and Public Citizen Health Research Groun

v. FDA,704F2d1280 (DC Cir.1983).

(4) Some examples of categories of information which fit into the definition of proprietary information are:

Information that discloses a process, method, or apparatus, including supporting a.

data and analyses, where prevention ofits use by General Electric's competitors without license from General Electric constitutes a competitive economic advantage over other companies; b.

Information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product; GBS-9.611-afstab12. doc Aflidavit Page 1 mi~-r

r -.

H.

t

7..

1 c.

Information which reveals cost or price-information, production capacities, budget levels, or commercial strategies of General Electric, its customers, or its

]

suppliers-1

'd.

Information which reveals aspects of past, present, or future General Electric j

customer-funded development _ plans and programs, of potential commercial

- value to General Electnc, e.

- Information which discloses patentable subject matter for which it may_ be desirable to obtain patent protection.~-

[

The information sought to be withheld is considered to be proprietary for the reasons l

E set forth in both paragraphs (4)a. and (4)b., above, e

(5) The information sought to be withheld is~ being submitted to NRC in confidence.

The information is of a sort customarily held in confidence by GE, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and i

belief, consistently been held in confidence by GE, no public disclosure has been made, and it is not available in public sources. All disclosures to third parties including any required transmittals to NRC, have been made, or must be made, pursuant to regulatory provisions or proprietary agreements which provide for maintenance of the information in confidence. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs (6) and (7) following.

(6) Initial approval of proprietary treatment of a document is made by the manager of l

the originating component, the person most likely to be acquainted with the value j

and sensitivity of the information in relation to industry knowledge. Access to such documents within GE is limited on a "need to know" basis.

I (7) The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist or other equivalent i

l authority, by the manager of the cognizant marketing function (or his delegate), and

. by the Legal Operation, for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside GE are limited to i

regulatory bodies, customers, and potential customers, and their agents, suppliers, L

and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary agreements.

(8) The information identified in paragraph (2), above, is classified as proprietary-l because it contains detailed results of analytical models, methods and processes, including computer codes, which GE has developed, obtained NRC approval of, and l

applied to perform evaluations of BWR core and channel thermal-hydraulic stability j

conditions.

i GBS-95-11-afstabl2. doc.

Afridavit Page 2 4

$ ul

.m;.._..

t J

.The development and approval'of the BWR thermal-hydraulic stability methods used in this analysis 'was achieved at a significant cost,' on the order of several million dollars, to GE.

The Ldevelopment of the evaluation process along with the interpretation and i

application of the analytical results is derived from the extensive experience database that constitutes a major GE asset.

-(9) Public disclosure of the information sought to be withheld is likely to cause substantial harm to GE's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of GE's comprehensive

- BWR safety. and technology base, and its commercial value extends beyond the '

original ' development cost. The value of the technology base goes beyond the' extensive physical database and analytical methodology and includes development j

of the expertise to determine and apply the appropriate evaluation process. In

i

. addition, the technology base includes the value derived from providing analyses done with NRC-approved methods.

The research, development, engineering, analytical and NRC review costs comprise a substantial investment of time and money by GE.

i

.The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial.

i

. GE's competitive advantage will be lost if its competitors are able to use the results of the GE experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same 1

or similar conclusions.

The value of this information to GE would be lost if the information were disclosed' to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly l

provide competitors with a windfall, and deprive GE of the opportunity to exercise i

its competitive advantage to seek an adequate return on its large investment in i

developing these very valuable analytical tools.

4

)

GBS-9511 afstabl2. doc.

Affidavit Page 3

t STATE OF CALIFORNIA

)

)

ss:

COUNTY OF SANTA CLARA

)

George B. Stramback, being duly sworn, deposes and says:

That he has read the foregoing affidavit and the matters stated therein are true and correct to the best of his knowledge, information, and belief.

/

Executed at San Jose, California, this 90 day of t/

1995.

Bucir< rbA Ge(rge B. fitramback General Electric Company Subscribed and sworn before me this 2o14 day of m, M 1995.

..xb 0 otary Public, State of Cal %

,,-*A' JUUE A. CURTS COMM. # 97t.657 Notoey Public - California SANTA CLARA COUNTY h4 Comm. Expires SEP 30.1996 t,

i GBS-9511-afstabl2. doc Affidavit Page 4 I

(

[d RTS-287 to NG-95-3121 Page 1 of 4 F

EVALUATION OF CIIANGE PURSUANT TO 10 CFR SECTION 50.92

Background:

10 CFR 50 Appendix A, General Detign Criterion is requires that the reactor and associated systems be designed to assure that power oscillations that could cause fuel design limits to be exceeded are not possible or can be reliably and readily detected and suppressed. The advent of 8X8 fuel designs and aggressive operating strategies in the 1980's resulted in conditions where instabilities could no longer be demonstrated to be t

impossible for Boiling Water Reactors (BWRs). Consequently, General Electric (GE) issued guidance.to BWR operators, SIL-380 Rev.1, to aid in detecting and suppressing

~

such hypothetical oscillations which the DAEC incorporated into its plant Technical Specifications (TS), Amendment #119, dated May 28,1985. In response to an instability 1-

. event in 1988, the NRC issued Bulletin 88-07, " Power Oscillations in Boiling Water i

Reactors", which required BWR owners to indicate how they intended to guard against l

further events. In addition, the BWR Owner's Group (BWROG) formed a committee to develop long term solutions. In 1994, the NRC issued Generic Letter (GL) 94-02, "Long-l Term Solutions and Upgrade ofInterim Operating Recommendations for Thermal-Ilydraulic Instabilities in Boiling Water Reactors". In response to GL 94-02, the DAEC j '

supersede the recommendations of SIL-380 Rev. I and the interim actions taken in committed to implement the BWROG Option I-D long term solution which would response to GL 88-07. The DAEC also committed to request a change to the plant TS to require that a reactor scram be initiated in the event the plant enters natural circulation conditions.

Option I-D, Regional Exclusion with Flow-Biased Average Power Range Monitor (APRM) Neutron Flux Scram, calls for the creation of an exclusion region in the power-flow operating map which bounds the area where calculations indicate power oscillations are possible. The operators will be instructed to immediately take action to exit this region if the plant should inadvertently operate there. The second part of the solution involves an analysis which demonstrates that the flow-biased APRM neutron flux scram will detect and suppress core-wide power oscillations should they occur. Regional mode core oscillations are not predicted to occur at the DAEC because ofits small core size and tight core inlet orifices.

In the course of preparing this TS change request, it was determined that certain specifications related to single recirculation pump operation (SLO) could be deleted.

Currently, when the plant is operating in SLO, the operators are required to verify that the core plate differential pressure noise level does not exceed certain levels. This specification was included in TS Amendment #119 due to NRC concerns at the time that high core plate noise observed during SLO at Brown's Ferry in 1985 could be an

- indication of thermal hydraulic instability. It has since been determined that core plate differential pressure noise is not a cause of thermal hydraulic instability and that the noise does not pose a safety concern (Technical Resolution of Generic Issue No. B-59-(N-1)

I

  • i RTS-287 to NG-95-3121 Page 2 of 4 1-i

. Loop Operation in BWRs and PWRs (Generic Letter No. 86-09), dated March 31,1986).

Therefore, the DAEC proposes to remove the current core plate noise surveillance t

requirements from TS.

1 j

IES Utilities Inc.. Docket No.50-31L Duane Arnold Energy Center. I. inn County. Iowa

]

Date of Amendment Recuest: November 30.1995 Descrintion of Amendment Reauest:

The proposed Technical Specifications changes would implement the Option I-D long-term stability solution and remove the existing SIL-380 Rev.1-based specifications. In addition, this proposed change would require a plant scram be initiated should the plant J

enter natural circulation conditions and prohibit restarting a recirculation pump while in i

natural circulation as well as define natural circulation. Finally, this change would delete j

TS actions and surveillance requirements related to core plate differential pressure noise l

while in SLO.

I j

Basis for nronosed No Significant Hmrds Consideration:

The Commission has provided standards (10 CFR Section 50.92(c)) for determining i

whether a significant hazards consideration exists. A proposed amendment to an operating license for a facility involves no significant hazards consideration if operation j

of the facility in accordance with the proposed amendment would not (1) involve a j

significant increase in the probability or consequences of an accident previously i

evaluated; (2) create the possibility of a new or different kind of accident from any j

accident previously evaluated; or (3) involve a significant reduction in a margin of safety.

t After reviewing this proposed amendment, we have concluded:

j

1) The proposed license amendment does not involve a significant increase in the probability or consequences of an accident previously evaluated. The implementation of the BWR Owner's Group long term solution Option I-D does not modify the assumptions i

in the existing accident analysis. The use of an exclusion region and the operator actions j

required to avoid and minimize operation inside the region do not increase the possibility l

of an accident. Licensing Topical Report, ' Evaluation of the " Regional Exclusion with Flow-Biased APRM Neutron Flux Scram" Stability Solution', GENE-A000-04021-01 l

. (attachment 1) demonstrates that the APRM flow-biased scram function provides a high degree of assurance that the fuel safety limit will not be exceeded should power oscillations occur during plant operation within the restricted region. Regional mode core i

j oscillations are not predicted to occur at the DAEC because ofits small core size and

+

l tight core inlet orifices. Conditions for operation outside of the exclusion region are i

e+.

+ - - -

.m.

i

~ T-RTS-287 to NG-95-3121 Page 3 of 4 4

within the assumptions of the existing accident analysis. The operator action requirement to exit the exclusion region upon entry minimizes the probability of an instability event occurring, inserting control rods or increasing recirculation flow, the evolutions to be used to exit the region, are normal plant maneuvers.

i The proposed clarifications to explicitly direct the operator to initiate a reactor scram in the event of operation in natural circulation are conservative and consistent with current plant operating practices. Likewise, the proposed prohibition from starting a recirculation j

pump as a means of exiting the natural circulation mode of operation is also conservative.

Therefore, the proposed license amendment does not involve a significant increase in the probability or consequences of an accident previously evaluated.-

i I

The core plate differential pressure noise surveillances that are performed while in single j

recirculation pump operation were included in TS Amendment #119 due to NRC i

concerns at the time that high core plate noise observed during SLO at Brown's Ferry in l

1985 could be an indication of thermal hydraulic instability. GE has since determined I

that core plate differential pressure noise is not a cause of thermal hydraulic instability l

and that the noise does not pose a safety concern. Therefore, the proposed license amendment does not involve a significant increase in the probability or consequences of l

an accident previously evaluated.

i t

2) The proposed license amendment does not create the possibility of a new or different kind of accident from any previously evaluated. As stated above, the proposed changes either mandate operation within the envelope of previously analyzed plant operating i

conditions or direct the operator to immediately return the plant to within these analyzed conditions using normal plant maneuvers. In addition, analysis has demonstrated that the i

APRM flow-biased scram function provides a high degree of assurance that the fuel safety limit will not be exceeded should power oscillations occur during plant operation j

within the restricted region. Therefore, the potential for a new or different type of a cident from those previously evaluated is not created.

The proposed clarifications to explicitly direct the operator to initiate a reactor scram in the event of operation in natural circulation are conservative and consistent with current j

plant operating practices. Likewise, the proposed prohibition from starting a recirculation j-pump as a means of exiting the natural circulation mode of operation is also conservative.

j Therefore, the potential for a new or different type of accident from those previously evaluated is not created.

The core plate differential pressure noise surveillances that are performed while in single recirculation pump operation were included in TS A.mendment #119 due to NRC concerns at the time that high core plate noise observed during SLO at Brown's Ferry in 2

]

.1985 could be an indication of thermal hydraulic instability. GE has since determined that core plate differential pressure noise is not a cause of thermal hydraulic instability i

3

i RTS-287 - to NG-95-3121 Page 4 of 4 and that the noise does not pose a safety concern. Therefore, the potential for a new or different type of accident from those previously evaluated is not created.

3) The proposed amendment will not reduce the margin of safety. The combim. tion of the proposed requirements to avoid possible unstable conditions ud the automatic flow biased high reactor flux scram provide defense in depth to provide fuel protection.

Therefore the individual or combination of means to detect and suppress thermal hydraulic instability supplements the margin of safety.

l The proposed specification related to initiating a reactor scram while in natural circulation is conservative. Likewise, the proposed prohibition from starting a recirculation pump as a means of exiting the natural circulation mode of operation is also conservative and therefore does not constitute a reduction in the margin of safety.

The core plate differential pressure noise surveillances that are performed while in single recirculation pump operation were included in TS Amendment #119 due to NRC concerns at the time that high core plate noise observed during SLO at Brown's Ferry in 1985 could be an indication of thermal hydraulic instability. GE has since determined that core plate differential pressure noise is not a cause of thermal hydraulic instability end that the noise does not pose a safety concern. Therefore, the elimination of these surveillance tests does not constitute a reduction in the margin of safety.

Based upon the above, we have determined that the proposed amendment will not involve j

a significant hazards consideration.