ML20095A895

From kanterella
Jump to navigation Jump to search
Application for Amend to License DPR-49,consisting of Request for TS Change RTS-287 to Implement Option I-D Reactor Stability Solution
ML20095A895
Person / Time
Site: Duane Arnold 
Issue date: 11/30/1995
From:
IES UTILITIES INC., (FORMERLY IOWA ELECTRIC LIGHT
To:
Shared Package
ML19317C170 List:
References
NUDOCS 9512080063
Download: ML20095A895 (2)


Text

i RTS-287 to NG-95-3121 Page1of2 PROPOSED CHANGE fRTS-287] TO THE DUANE ARNOLD ENERGY CENTER TECH'NICAL SPECIFICATIONS The holders oflicense DPR-49 for the Duane Arnold Energy Center propose to amend Appendix A (Technical Specifications) to said license by deleting certain current pages and replacing them with the attached, new pages. The List of Affected Pages is given below.

LIST OF AFFECTED PAGES vii 1.1-11 1.1-12 3.3-6 3.3-7 3.3-7a 3.3-7b 3.3-13 3.3-15 3.3-16 6.11-4

SUMMARY

OF CHANGES:

The following list of proposed changes is in the order that the changes appear in the Technical Specifications (TS).

Page Descrintion of Changes vii Deletes the reference to Figure 3.3-1, " Thermal Power vs. Core Flow Limits for Thermal Hydraulic Stability Surveillance."

1.1-11,12 Revises the Bases of the Average Power Range Monitor (APRM) high flux scram to describe the protection the flow-biased APIGi setpoints provide against exceeding fuel safety limits during all abnormal operational transients including those that may result in thermal hydraulic instability.

l 9512080063 951130 PDR ADDCK 05000331 P_,.

PDR s

.. ~..

.... -.. - - -.-.. - ~..

C

^ RTS 287: to i

NG-95-3121 I

Page 2 of 2 3.3-6 Clarifies specification 3.3.F.1 to state that operation in natural circulation (as defined in a footnote at the bottom of the page) is i

not permitted. The specification will further state that should j

operation in natural circulation occur, that the reactor shall be scrammed.

j j

3.3-6 Clarifies 3.3.F.2 to state that no recirculation pumps shall be i

placed in operation while the reactor is in natural circulation (as l

defined by footnote).

i.

{

3.3-6,7 Replaces 3.3.F.3 with the requirement that operation in the l

Exclusion Region of the power / flow map described in the Core '

Operating Limits Report is not permitted. In addition, the specification will state that should entry into this region occur, i

control rods are to be immediately inserted or core flow is to be immediately increased to exit the region. The surveillance j

requirements of 4.3.F.3 are also deleted.

I 3,3-7a Deletes thermal hydraulic instability related requirements for single loop recirculation operation as well as the requirements related to core plate differential pressure noise.

i 4

3.3-7b Deletes additional requirements related to core plate differential pressure noise.

3.3-13,14 Revises the Technical Specification Bases 3.3.F related to recirculation pumps and thermal hydraulic instability concerns.

3.3-15 Add reference to General Electric topical report GENE-A0000-04021-01, Apolication of the " Regional Exclusion with Flow-l 7

1 Biased APRM Neutron Flux Scram" Stability Solution (Option I-D) to the Duane Arnold Energy Center 6.11-4 Add specification 6.11.2.a.5) to include the Exclusion Region in the power / flow map (Specification 3.3.F.3) in the Core Operating a

Limits Report.

N Miou ant.icensingwT emplate%R1 S PGs. dot a

l 1

J

,,-..-.n.-

,,.n es

.m