Text

4 NRC MONTHLY OPERATING REPORT DOCKET NO. 50-361 UNIT NAME SONGS - 2 DATE 9/15/84 (as revised 3/15/84)

COMPLETED BY C. A. Morris TELEFHONE (714) 492-7700 Ext. 56264 OPERATING STATUS 1.

Unit Name: San Onofre Nuclear Generating Station, Unit 2 2.

Reporting Period:

8 August 1983 through S1 August 1983 3.

Licensed Thermal Power (MWt):

3,390 4.

Nameplate Rating (Gross MWe):

1,127 5.

Design Electrical Rating (Net MWe):

1,070 6.

Maximum Dependable Capacity (Gross MWe):

1,127 7.

Maximum Dependable Capacity (Net MWe):

1,070 8.

If Changes Occur In Capacity Ratings (Items Number 3 Through 7)

Since Last Report, Give Reasons:

NA 9.

Power Level To Which Restricted, If Any (Net MWe):

NA 10.

Reasons For Restrictions, If Any:

NA This Month Yr.-to-Date Cumulative

11. Hours In Reporting Period 576 576 576
12. Number Of hours Reactor Was Critical 576 576 576
13. Reactor Reserve Shutdown Hours 0

0 0

14. Hours Generator On-Line 576 576 576
15. Unit Reserve Shutdown Hours 0

0 0

16. Gross Thermal Energy Generated (MWH) 1,905,209 1,905,209 1,905,209 17.' Gross Electrical Energy Generated (MWH) 659,758 659,758 659,758
18. Net Electrical Energy Generated (MWH) 641,628 641,628 641,628
19. Unit Service Factor 100 100 100
20. Unit Availability Factor 100 100 100
21. Unit Capacity Factor (Using MDC Net) 104.1 104.1 104.1
22. Unit Capacity Factor (Using DER Net) 104.1 104.1 104.1
23. Unit Forced Outage Rate 0

0 0

24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

18-month Surveillance Outage, November 15, 1983,- 1-month duration.

25.

If Shut Down At End Of Report Pcriod, Estimated Date of Startup:

NA

26. Units In Test Status (Prior To Commercial Operation):

Forecast Achieved INITIAL CRITICALITY NA NA INITIAL ELECTRICITY NA NA COMMERCIAL OPERATION NA NA 8403200091 840315

~

DR ADOCK 05000361 PDR

AVERAGE DAILY UNIT POW 5R LEVEL DOCKET NO.

50-361 UNIT SONGS - 2

-DATE 9/15/83 (as revised 3/15/84)

COMPLETED BY L. Mayweather s

TELEPHONE (714) 492-7700 Ext. 56264 s

NONTH August 198_3 s

DAY AVERAGE DAILY 'PbWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 NA 17 1127.67 2

NA 18 1114.46 3

NA 19 1082.60 4'

NA -

20 948.33

_~

'S NA 21 1115.73 6

NA 22 3_069.67 7

Nd 23 1123.69 8

1132.50 24 1134.52 s

9_

^1073.33 m

25 1137.00 m

3 10 1107.29 26 1099.98 11 1Q3.75 27-1075.85 m

12 1115.71 28, 886.67

~

.29 1115.83 13 1130.42 s

s 14

- 1126.79

.30

-1137.50 15 1125.58 31 2

1117.92 m

16 1111'.88 i -

0565u

..b 5

~.

~

, (

'e

)

}>

's

-s s3 5

f,,'

3 r

s i"

8

~.

m.

t l

l I! NIT SHUTDOWNS AND POWER REDUCTIONS DOCKET No. 50-361 UNIT NAME SONGS - 2 i

REPORT MONTH AUCUST, 1983 DATE 09/15/83 fas j

revised 3/15/84)

COMPLETED BY L. Mayweather TELEPHONE (714) 492-7700 Ext. 56223 Method or Shutting Dura tion Down LER System Component Cause & Corrective 1

2 3

4 5

Action to No.

Date Type

,(Hours)

Reason Reactor No.

Code

. Code Prevent Recurrence NA-NA NA NA NA NA NA NA NA NA i

i l

i.

L i

l i

1 2

3 4

' F-Fo rced Reason:

Method:

Exhibit F - Instructions S-Scheduled A-Equipment Fa ilure (Expla in) 1-Manual for Prepa ration of DM.a B-Ma ir.tenance or Test 2-Manua l Scram.

Entry Sheets for Licensee C-Rerueling 3-Automa tic Scram.

Event Report (LER) *8 le D-Regulatory Restriction 4-Continuation from (NUREG 0161) i E-Operator Training & License Examination Previous Month F-Admin i st ra t ive 5-Reduction of 20%

5

' G-Ope ra t i ona l Error (Expla in) or greater in the Exhibit H-Same Source H-Other (Enla in) past 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 0565u 6-Other (Expla in) i E

i e

k

_