NRC MONTHLY OPERATING REPORT DOCKET NO. 50-361 UNIT NAME SONGS - 2 DATE 1/16/84 (as re-vised 3/15/84)
COMPLETED BY C. A. Morris TELEPHONE (714) 492-7700 Ext. 56264 OPERATING STATUS 1.
Unit Name:
San Onofre Nuclear Generating Station, Unit 2 2.
Reporting Period:
1 December 1983 through 31 December 1983 3.
Licensed Thermal Power (MWt):
3,390 4.
Nameplate Rating (Gross MWe):
1,127 5.
Design Electrical Rating (Net MWe):
1,070 6.
Maximum Dependable Capacity (Gross MWe):
1,127 7.
Maximum Dependable Capacity (Net MWe):
1,070 8.
If Changes Occur In Capacity Ratings (Items Number 3 Through 7)
Since Last Report, Give Reasons:
NA 9.
Power Level To Which Restricted, If Any (Net MWe):
NA 10.
Reasons For Restrictions, If Any:
NA This Month Yr.-to-Date Cumulative
- 11. Hours In Reporting Period 744 3505 3505
- 12. Number Of Hours Reactor Was Critical 307.4 2612.7 2612.7 13.
Reactor Reserve Shutdown Hours 0
0 0
14.
Hours Generator On-Line 274.6 2561.7 2561.7
- 15. Unit Reserve Shutdown Hours 0
0 0
- 16. Gross Thermal Energy Generated (MWH) 885,405 8,493,535
_8,493,535
- 17. Gross Electrical Energy Generated (MWH) 306,662 2,911,964 2,911,964
- 18. Net Electrical Energy Generated (MWH) 284,352 2,775,644 2,775,644
- 19. Unit Service Factor 36.9 73.1 73.1
- 20. Unit Availability Factor 36.9 73.1 73.1
- 21. Unit Cap
- city Factor (Using MDC Net) 35.7 74.0 74.0
- 22. Unit Capacity Factor (Using DER Net) 35.7 74.0 74.0
- 23. Unit Forcec Outage Rate 0
3.8 3.8 24.
Shutdowns Sc.ieduled Over Next 6 Months (Type, Date, and Duration of Each):
NA 25.
If Shut Down At End Of Report Period, Estimated Date of Startup:
HA
- 26. Units In Test Status (Prior To Commercial Opdration):
Forecast Achieved INITIAL CRITICALITY NA NA INITIAL ELECTRICITY NA NA COMMERCIAL OPERATION NA NA 8403200077 Eb00315 PEWt ADOCK 0500<1361 l
R pggg l
1
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-361 UNIT SONGS - 2 DATE 1/_16/84 (as revf ad 3/15/8'-
COMPLETED BY C. A. Morris TELEPHONE (714) 492-7700 Ext. 56264 MONTH:
December 1983 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1 0
17 0
2 0
18 0
3 0
19 0
4
_ 0 20 58.42 5
0 21 818.96 6
0 22 1099.90 7
0 23 1106.25 8
0 24 1113.23 9
0 25 1139.58
^
10 0
26 1166.56 11 0
27 1079.90 1
1E O
28 1146.88 l
13 0
29 1203.75 14 0
30 1109.50 t
15 0
31 1133.40 i
16 0
0565u n.
w.
e n-,,
a v
,-m e-
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-}61 UNIT NAME SONGS - 2 REPORT MONTH DECEMBER, 1983 DATE 1/16/84 tas revised 3/15/84)
COMPLETED BY C.
A.
Mo r ri r.
TELEPHONE f714) 492-7700 Ext. 56264 Method of Shutting Du ra t ion Down LER System Component Cause & Corrective 1
2 3
4 5
Action to No.
Date Type (Hours)
Reason Reactor No.
Code Code Prevent Recurrence 25 831114 S
469.4 F
4 NA NA NA 18-Month Survei llance Outage.
l l
l l
l e
l I
I l
1 2
3 4
F-Fo rced Reason:
Method:
Exhibit F-I nst ruct ions S-Scheduled A-Equipment Fa ilure (Expla in) 1-Manual for Preparation o r Cata 4
B-Ma intenance or Test 2-Manual Sc ra m.
Entry Sheets for Licensee C-Refueling 3-Automatic Sc ram.
Event Report (LER) File D-Regula to ry Restriction 4-Continuation f rom (NUREG 0161)
E-Operator Training & License Examination Previous Month F-Adm ini st ra t ive 5-Reduction of 20%
5 G-Ope ra t iona l Error (Expla in) or Greater in the Exhibit H-Same Source l
H-Other ( Explain)
Past 24 Hours 0565u 6-Othe r ( Expla in) l 1
i
_ _ _. - _ _ _ _. _ - _. _. - _ _ _