1 NRC MONTHLY OPERATING REPORT DOCKET NO. 50-361 UNIT NAME SONGS - 2 3
DATE 12/15/83 (as I
revised 3/15/84)
COMPLETED BY C. A. Morris TELEPHONE (714) 492-7700 Ext. 56264 OPERATING STATUS 1.
Unit Name:
San Onofre Nuclear Generating Station, Unit 2 2.
Reporting Period:
1 November 1933 through 30 November 1983 3.
Licensed Thermal Power (MWt):
3,390 4.
Nameplate Rating (Gross MWe):
_1,127 5.
Design Electrical Rating (Net MWe):
1,070 6.
Maximum Dependable Capacity (Gross MWe):
1,127 7.
Maximum Dependable Capacity (Net MWe):
1,070 8.
If Changes Occur In Capacity Ratings (Items Number 3 Through 7)
Since Last Report, Give Reasons:
NA 9.
Power Level To Which Restricted, If Any (Net MWe):
NA
- 10. Reasons For Restrictions, If Any:
NA This Month Yr.-to-Date Cumulative
- 11. Hours In Reporting Period 720 2761 2761
- 12. Number Of Hours Reactor Was Critical 331.0 2305.3 2305.3
- 13. Reactor Reserve Shutdown Hours 0
0 0
- 14. Hours Generator On-Line 331.0 2287.1 2287.1
- 15. Unit Reserve Shutdown Hours 0
0 0
- 15. Gross Thermal Energy Generated (MWH) 1,113,802 7,608,130 7,608,130
- 17. Gross Electrical Energy Generated (MWH) 377,015 2,605,302 2,605,302
- 18. Net Electrical Energy Generated (MWH) 355,435 2,491,292 2,491,292
- 19. Unit Service Factor 46.0 82.8 82.8
- 20. Unit Availability Factor 46.0 82.8 82.8
- 21. Unit Capacity Factor (Using MDC Net) 46.1 84.3 84.3
- 22. Unit Capacity Fac. tor (Using DER Net) 46.1 84.3 84.3
- 23. Unit Forced Outage Rate 2.2 4.2 4.2
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
NA
=
25.
If Shut Down At End Of Report Period, Estimated Date of Startup: 15 December 1983
- 26. Units In Test Status (Prior To Commercial Operation):
Forecast Achieved INITIAL CRITICALITY NA NA INITIAL ELECTRICITY NA NA COMMERCIAL OPERATION NA NA 0403200082 840315 PDR ADOCK 05000361 R
.--s
-,r--
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-361 UNIT SONGS - 2 DATE 12/15/83 (as revised 3/15/84)
COMPLETED BY C. A. Morris TELEPHONE (71a) 492-7700 Ext. 56264 MONTH: November 1983 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1 1096.71 17 0
2 1103.48 18 6
3 1100.35 19 0
4 1094.13 20 0
5 1079.58 21 0
6 1090.33 22 0
~
7 1110.00 23 ____
0 8
995.00 24 0
9 1072.92 25 0
10 1095.83 26 0
11 1105.48 27 0
12 1096.00 28 0
13 1100.67 29 0
14 844.23 30 0
15 0
31 NA 16 0
0565u e
+
e
..~
m UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-361 UNIT NAME SONGS - 2 REPORT MONTH NOVEMBER, 1983 DATE 12/15/83 (as revised 3/15/84)
COMPLETED BY C.
A.
Morris 4
TELEPHONE ( 7?4) 492-7700 Ext. 56264 x
Method of Shutting Du ra t ion Down LER Systcm Component Cause & Corrective -
1 2
3 4
- 5
' Action to No.
Date Type (Hours)
Reason Reactor No.
Code Code Prevent Recurrence
'25 831114 F
16 G
2 83-151 RB VALVEX Reactor manually tripped due to pressurizer pressure and level decreases, af ter an operator erroneously opened emergoney bora tion va lve 2HV-9247.
The operator was counseled.
S 373 F
i4A '
NA NA NA 18-Month Surveillance Outage.
4 1
2 3
4 l
F-F o rced Reason:
. Method:
Exhibit F-Instructions S-Scheduled
- A-Equipment Fa i lure ( Expla in) 1-Manual for Preparation of Data B-Ma intenance or. Test 2-Manua l Sc ram.
Entry Sheets for Licensee C-Refueling 3-Automatic Scram.
Event Report (LER) File D-Regulatory Restriction 4-Con t i r,ua t i on f rom (NUREG 0161)
E-Operator Training & License Examination Previous Month F-Adm in i st ra t ive 5-Reduction of 20%
5 G-Ope ra t iona l Error ( Expla in) or greater in the Exhibit H-Same Source H-Othe r ( Expla in).
past-24 hours 0565u 6-Other ( Explain) i i
i c
,