- - _ _.

\\.

N FLORIDA POWER & UGHT COMPANY May 31, 1974 p') H-71

  • NCAM Mr. Angelo Giambusso Deputy Director for Reactor Projects Directorate of Licensing Office of Regulation U. S. Atomic Energy Commission Washington, D. C.

20545 Dear Mr. Giambussor TURKEY POINT UNIT NO. 3 DOCKET NUMBER 50-250 REINSPECTION OP SAFETY RELATED HYDRAULIC PIPE RESTRAINTS ACCESSIBLE DURING POWER OPERATION Reinspection of the accessible safety related piping res-traints in accordance with the continuing requirements of the Directorate of Licensing letter of November 8, 1973, was completed on May 20, 1974.

There were 20 restraints inspected and all are of the Bergen-Paterson design.

The inspection showed that all of these restraints were in sat-isfactory condition.

Very truly yours, R. B. Uhrig Vice President REU/HNP/kaw cc:

Mr. Norman C. Moseley Jack R. Newman, Esquire

(/ [

u 8306140703 740716

.s (I

DR ADOCK 05000

~