. . . _ _ _ _ . . - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

i C321-95-2113 ATTACIIMENT I XIS-1 FORM OYSTER CREEK NUCLEAR GENERATING STATION REFUELING OUTAGE 15R 78gs2gggcgogggggi, Q PDR

l l , .

MIS-1 REPORT ABSTRACT

10. This submittal is for ISI examinations that were performed ,

during the second re-fueling outage (Oyster creek 15R) of the -

first inspection period of the third inspection interval. The examination dates are from 2/17/93 to 12/15/94. The initial scope was for 111 Inservice exams, and 11 Augmented exams. l Examinations completed were JJi Inservice, 11 Augmented, and i an additional 11 Preservice. Removed from scope were six Inservice exams for three welds and four Augment exams for two welds, because of limitations. The minimum 90% coverage for i these welds could not be achieved.

11 '. Forty-four components were found to have minor deficienci .

From the In-vessel Visual Inspections six components uca o  :

reported as having indications. The following is a brief summary. A listing if ISI conditions is reported in Table 2.  ;

INSPECTION COMPONENT RESULTS DISPOSITION PREVIOUS EXPERIENCE  ;

STEAM DRYER DRYER STOP FATIGUE BRACKET DRILL BRACKET i CRACKING FATIGUE CRACKING  !

REPAIR l 1

STEAM SEPARATOR BRACKET ACCEPTABLE <

CRACK AS IS i DRYER SUPPORT BRACKET BENT / TEAR ACCEPTABLE AS IS  :

, FEEDWATER SPARGER KEEPER BOLT ACCEPTABLE

( TACK AS IS WELD CRACK i TOP GUIDE THREE ACCEPTABLE THREE CRACKS AS IS PREVIOUS MIDSPAN CRACKS.NO MEASURABLE GRO%TH SIIROUD SIGNIFICANT PERMANENT CRACKING IN REPAIR H4 INSTALLED

12. The corrective measures taken for deficiencies detected by examinations are discussed in Table 2.

REVIEWED l HARTFORD STEAM BOILER I. & l. CD, Authf N tl**r 1-w a 1s. - -

YW D-te

l FORM NIS-1 (bsck) i

~

8. Examination Dates 2/17/93 to 12/15/94 9. Inspection Interval from 3/15/92 to 3/14/02
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. See Attached
11. Abstract of Conditions Noted See Attached
12. Abstract of Corrective Measures Recommended and Taken See Attached I

i We certify that the statements made in this report are correct and the examinations and corrective mea-i sures taken conform to the rules of the ASME Code,Section XI.

Jersey Central Power & Light Date h/S /7 19.f_[. Signed _ _ .

_ By

  • " g% , hdCEf/$/

Certificate of Authorization No. (if applicable) O Expiration Date 8 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and/or the State or Province of New Jersey and employed by H. S.B. I. & I. Co. of l Hartford Ct. have inspected the components described in this Owners' Data Report during the period I 2/17/93 to 12/15/94 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Data Report. Furthermore, i neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage i or a loss of any kind arising from or connected with this inspection.

l Date M #7 19 6 ,

Commissions NEL47B (T ) (N) NJ442

  1. National Board, State. Province and No.

inspector's Signa [pfre l

l l

l l

\

l 1

l i

J

8 FORM NIS 1 OWNEi"e..,";E INSPECTIONS As require "" Rules Jersey Central'I

1. Owner Madison Avenue:ma-w;  ?" N.J.

Oyster Creek Nu? '

2. Plant U.S. Hwy. Routc7 m:ww ,
3. Plant Unit ,

N/A eum8 tequired)

5. Commercial Service Date 12/2em.zrz Rx Vessel 14895
7. Components inspected see

.was Component or Manuf *' State or National Appurtenance or In ~ :frovince No. Board No.

O,; %T .1Th\

\ 4. Y, MC s . , g ch ,

5 h -

N s

N N

Note: Supplemental sheets in form of 4 provided (1) size is 8% in. x 11 in..

(2) information in items 1 through 6 j

Acet, and (3) each sheet is numbered and the number of sheets is recorded q...

10017 This fe m (E00029) ma4 ,,f. 345 E. 47th St., New York, N.Y.

t FORM NIS-1 OWNERSo DATA REPORT FOR INSERVICE INSPECTIONS l l As required by the Provisions of the ASME Code Rules i

Jersey Central Power and Light

1. Owner Madison Avenue and PunchBowl Road, Morristown. N.J. ,

i Oyster Creek Nuclea(Name and Address of r Generating Owner)'

Station l 2. Plant U.S.' Hwy. Route 9, Forked River, N.J. 08731 ,

(Name and Address of Plant) s h

3. Plant Unit ,

N/A 4. Owner Certificate of Authorization (if required)  ;

5. Commercial Service Date 12/23 /69 6. National Board Number for Unit Rx Vessel 14895 '
7. Components inspected See Attached Sheets ,

i Manufacturer 5 Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No. Province No. Board No.  ;

k b .%s ., e hdl/ 'id NN 5 d7\

mm.<,. s 7

7m ,s N '

N  !

Ns N

N N

Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 84 in. x il in.,

(2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E000291 may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

^

NIS-1 DwNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95 PAGE:'0001 a ,

1. OWNER: Jersey Cent ral Power & Light Ccmpsny. Radison Avenus &

Punch Bowl Road. Cerristown. Nam Jersey

2. PLANT: Oyster Creek Nuclear Generating Station.

U.S. Route 9 Forked River. New Jersey .

3. PLANT UNIT: NA 4 OWNER CERTIFICATION OF AUTHOR 12ATION (if reautred): None E. CDWWERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor vessel 14895 OUTAGE 15R TABLE 2

...... ......---......-..........- ...........==- ..........--.=-- -- ........ .------- = ....................-.......-.......

l IDENTIFICATION i l t i I ExAr $ASWE ASME. : TAG NUMBER .

NDE I NO. l CAT l ITEM NF SUFFIX CODE DESCRIPTION SYS METHl UNACCEPTABLE INDICATION AND DISPOSITION ,

.----- . - . . . . . . . . . . . . . ........---- _ - - . . . . . . = - - - ---- =-.==_ ...-.. - = --..-- ...... __ .-...-.........--......

000000156 B-F B5.130 'J-2-0002 ELBOW TO PIPE (BI-WETALIC ' NU llSUR SUFACE PLANAR.(SECT.x!).IWA-3310

. WELD WELD) ACCEPTED BY EVALUATION

  • I 000002682 B-J B9.11 'Nk-2-0061 PIPE TO VALVE NE UT l SUFACE PLANAR.(SECT.XI).IwA-3310 WELD ACCEPTED BV EVALUATION 000000392 B-J B9.11 .

NU-1-0016 PIPE TD ELBOW NU SUR SUFACE PLANAR.(SECT.x1).IWA-3310 WELD ACCEPTED BV REPAIR t 000000394 B-J 89.11 NU-1-0018 elbow TO PIPE NU SUR SUFACE PLANAR.(SECT.XI).IWA-3310 WELD ACCEPTED BV REPAIR 000003387 B-J l 89.31 NU-2-0026 BRANCH TO PIPE NU . SUR SUFACE PLANAR.(SECT.x1).IwA.3310 WELD ACCEPTED BV REPAIR 000000992 B-J '89.32 NU-2-0040 PIDE TO BRANCH NU SUR SUFACE PLANAR.(SECT.XI).IwA-3310 WELD ACCEPTED BV REPAIR-i 000000789 B-J 89.40 NG-C-0025 PIPE TO ELBDw NG SUR SUBSURFACE PLAMAR.(SECT.XI).IwA-3320 WELD ACCEPTED BY EVALUATION 000003824 B-N-2 B13.40 NR02 SHROUD TOP GUIDE SUPPOR : RE UT SUBSURFACE PLANAR.(SECT.x1).IwA-3320 H-2 WELD  ? RING ACCEPTED BV REPAIR I

000003826 B-N-2 513.40 NR02 l SHROUD SHELL TO SHELL RA UT SUBSURFACE PLANAR.(SECT.x1).IwA-3320-H-4 WELD l ACCEPTED BY REDAIR i

000003828 B-N-2 513.40 NR02 l$HROUD LDwER INTERMEDIA Rx UT SUBSURFACE PLANAR (SECT.x1).IwA-3320 H-64 WELD TE RING ACCEPTED BY REPAIR I 1 000003829 B-N-2 513.40 NR02 SHROUD LDwER INTERNEDIA RX UT SUBSURFACE PLANAR.(SECT.x1).IwA-3320 H-6B WELD TE RING ACCEPTED BV REPAIR 000003887 B-N-2 513.40 NR02 TOP GUIDE '

Rx VT-3 VESSEL INTERNAL-CRACKING IN BASE METAL INTER-L VESSEL ACCEPTED BY EVALUATION 000003893 B-N-2 813.40 NR02 STEAM DRVER Rx VT-3 VESSEL INTERNAL-BRACKET CRACKING INTER-V = VESSEL ACCEPTED BY REPAIR 000003892 B-N-2 513.40 NR02 STEAM SEPARATOR (SHROUD NE Rx VT-3 VESSEL INTERNAL-84ACKET CRACKING INTER-w VESSEL AD)& HOLD DOWN BOLTS ACCEPTED BY EVALUATION I

000003895 8-N-2 513.40 NR02 FEEDWATER SPARGER AND THE ' RX VT-3 ' VESSEL INTERNAL-BOLTING DEFICIENCY INTER-Z VESSEL RMAL SLEEVE ACCEPTED BY EVALUATION

.-. _ ~ - _ _ _ _ , _ _ _ , - _ . . - . . _ _ _ _ _ _ _ _ , _ _ _ _ _ _ - - _ - _ _ _ _ - . _ . _ _ _ _ _ .

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95 PAGE: 0002 .

1 OWNER: Jersey Centnel Power & Light Company. Wadison Avenue &

Punch Bowl Road, Morristown. New Jersey

2. PLANT: Oyster Creen Nuclear Generating Station.

U.S. Route 9. Forhed River. New Jersey -

3. PLANT UNIT: NA 4 OWNER CERTIFICATION or AUTHORIZATION (i* reoutred): None
5. CowwERCIAL SERVICE DATE: 12/23/E9
6. NATIONAL BOARD NUWBER FOR UNIT Reactor VeBSel 14895 OUTAGE 15K TABLE 2

.....-=-- _.............. ....--... .. ....... ..... ...... .... .... ..........................--..................- . .......

"!DENTIFICATION l l 1 I i EXAv 1ASME ASWE TAG NUWBER l NDE NO. ICAT IITEW NO SUFFIA CODE i DESCRIPTION !SYS' WETH UNACCEPTABLE INDICATION AND DISPOSITION

.....---................................ ....- :-- _.........---.............--...... .....====- ..........................

000001601 lC-8-1 C5.11 I NE-1-210 PIPE TO N0ZZLE A CONDENSR NE SUR l SUFACE PLANAR.(SECT.XI).IwA-3310 WELD l ACCEPTED BY REPAIR 000003515 C 8-2 C5.51 -

NQ-2-0134 ELSDW TO REDUCING TEE  : NO SUR SUFACE PLANAR.(SECT.XI).Iwa-3310 WELD ACCEPTED BY REPAIR I

000003514 C-F-2l C5.51 INO-2-0134 ELB0w TO REDUCING TEE NO UT SUBSURFACE Pt.ANAP.(SECT.XI).IWA-3320

{ WELD ACCEPTED BY EVALUATION 000001148 C-F-2 C5.51 NZ-1-0018 LTEE TO PIPE NZ UT NONPLANAR FL4W.(SECT.XI).IwA-3340 WELD l ACCEPTED BY EVALUATION t i 000003T28 C-F-2 C5.51 lELBDw TO PIPE NZ-2-0235 NZ UT SUBSURFACE PLANAR.(SECT.XI).IWA-3320 WELD ACCEPTED BY EXAMINATION 000002194 D-B D2.20 '54;-1040 GUIDE CC VT-3 SUPPORT-BASE PLATE.ANCHORDEFICIENCY SUPORT .(CC-4-H14) ACCEPTED BY EVALUATION 000000195 F-A F1.10 225-BP-NC-4-R5-0013 RESTRAINT NC VT-3 SUPPORT-PIPE CLAMP DEFICIENCY SUPORT (NC-4-H12) { ACCEPTED BY EVALUATION I

000000107 F-A F1.10 211-BP-NE-5-H1-005T NE-5-10" VARIABLE SPRING NE lVT-3 SUPPORT-IWPROPER SETTING '

SUPORT PIPE MANGER (NE-5-H1) I ACCEPTED BV EVALUATION u 1 000002563lF-A - F1.10 H214-BP-NU-1-H1-0001 VARIABLE SPRING SUPPORT NU VT-3. SUPPORT-!WPROPER SETTING SUPORT (NU-1-H1) =l ACCEPTED BV EVALUATION I

000000204 F-A 'F1.10 !422-BP-RF-R-H11*0011 VARIABLE SPRING HANGER RF i VT-3 SUPPORT-!WPROPER SETTING SUPORT (RF-2-H11)- ACCEPTED BY EVALUATION 000002332 F-A  :

F1.10 216-1001 NEED DETAILED DwG. RHC VT-3 SUPPORT-WIS$1NG. LOOSE PARTS SUPORT (RHC-2-H2) ACCEPTED BY EVALUATION 000003700 F-A F1.20 211-BP-632-R7-0050 NE-1-12" HYDRAULIC PIPE NE VT-3 SUPPORT-BASE PLATE ANCHORDEFICIENCV-SUPORT SNUBBER-95/5 (NE-1-5124) ACCEPTED BY EVALUATION 000003711 P-A F1.20 211-BP-634-R5-0032  :

NE-2-B" HYDRAULIC PIPE '

NE ' VT-3 SUPPORT-BASE PLATE.ANCHORDEFICIENCY^

SUPORT. SNUBBER (NE-2-521) ACCEPTED BY EVALUATION 000003693 F-A F1.20 241-BP-487-R5-0032 HYDRAULIC SNUBBER - 23/3 NQ- VT-3 SUPPORT-DEFICIENT THREAD ENGAGEWENT SUPORT (N0-2-514) ACCEPTED BY REPAIR 000000443 F-A F1.20 212-BP-NZ-2-H43-0080 VARIABLE SPRING MANGER -

NZ VT-3 SUPPORT-DROMEN. BENT FASTENERS--

SUPORT (NZ-2-H36) i ACCEPTED BY REPAIR l

-. . - .- -- - . . -. - _ . _ - . - __ _ _ - - . - -.- = -_ - -__ -- - ..

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95 -

PAGE'0003 .

1 OWNER: Jersey Central Power & Light Company. M dison Avenue &

Punch Bowl Road. Eoreistown. New Jersey

2. PLANT: Dyster Creek Nuclear Generating Station.

U.S. Route 9 Formed River. New Jersey .

3. PLANT UNIT: NA 4 OWNER CERTIFICATION Or AUTHORtZATION (if required): None
5. COMMERCIAL SERVICE DATE: 12/23/09
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor vessel 14995 OUTAGE 15P TABLE 2 l l IDENTIFICATION i l i I i I  !

EXAM ASME ASME l TAG NUMBER l lNDE i NO. LCAT ITEM NOISUFFIX CODE I DESCRIPTION :SYSlMETH] UNACCEPTABLE INDICATION ANO DISPOSITION 000003710 F-A IF1.20 -1212-BP-368-R2-0015 $ HYDRAULIC SNUBBER  ! NZ VT-3 SUPPORT-BASE PLATE.ANCHORDEFICIENCY SUPORT l(NZ-2-SS) ACCEPTED BY EVALUATION I ,

-000003842 F-A F1.30 '

531-1019 (ROD HANGER Sw VT-3 SUPPORT-NOT CARRYING LOAD

  • I SUPORT ACCEPTED BY EVALUATION i
  • 000003648 P-A F1.30 1532-BP-Sw-2-H1-0002 ROD MANGER (Sw-2-H26) 'SWE VT-3 SUPPORT-DEFICIENT THREAD ENGAGEMENT SUPORT ACCEPTED BY REPLACEMENT 000002232 5-A lF1.40 411-BP-MSM-4-0030 '

VARIABLE SPRING SUPPORT 1MS VT-3 SUPPORT-DOES NOT CONFORM TO DETAIL ,

1 SUPORT (MS-1-H3C) ACCEPTED BY EVALUATION  !

000002727 P-A S t .40 ' '211-0125 l NE-2-10" VARIABLE SPRING NE VT-3 SUPPORT-IMPROPER 5ETTING l SUPORT HANGER ON V-14-0035 ACCEPTED BY EVALUATION 000000669 P-A F1.40 L223-GR-H4(C)-0026 CONSTANT NG VT-3 SUPPORT-IMPROPER SETTING SUPORT (NG-C-H3) ACCEPTED BY. EVALUATION 000002058HF-A I F1.40 P-20-001B CORE SPRAY PUMP NZO1-B NZ VT-3 SUPPORT-DEFICIENT THREAD ENGAGEMENT H-1 SUPORT. 2 WELDED 1 SUPPORT.ON SKID ACCEPTED BY EVALUATION  !

000003551 IGSCC B9.11 NG-C-0009A ELBOW TO PIPE NG UT ' SUBSURFACE PLANAR.(SECT.XI).IwA-3320 WELD ACCEPTED BY EVALUATION 000003554 IGSCC 59.11 NG-D-0018 PIPE TO PIPE NG . UT SUBSURFACE PLANAR.(SECT.XI).IwA-3320-WELD ACCEPTED BY-EVALUATION i

000003628 IGSCC 89.11 LNZ-3-0044R1 PIPE TO REDUCER (REPAIRED.. NZ UT l SUBSURFACE PLANAR.(SEC.T.AI).IwA-3320 WELD BY OVERLAY) ACCEPTED BY EVALUATION L

'I

, - - . - . . ~ , , . - ~ - - - , - - - . . - - , . , . . - _ , - - - - , ~ . . . - - , , -----..w_--,,w - w.~-,..,.,,m +.,-,n.,v,,..,.,...-,._..-n,--- ._.,n,--. . ..,,-.,.,.n.. ,, -

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/C5 PAGE: 0001 .

1 OWNER: Jersey Centrol Power & Licht Company. Cedison avsnus &

Punch Bowl Rosd. Corristeen. Ns= Jersey

2. PLANT: Oyster Creek Nuclear Generatin9 Station.

U.S. Route 9. Forked River. New Jersey .

3. PLANT UNIT: NA 4 OWNER CERTIFICATION OF AUTHORIZATION (if required): None
5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor vessel 14895 OUTAGE 1SR TABLE 1 I IDENTIc! CATION l EXAM l ASME ASME TAG NUMBED NDE DATE/ FROM DIAM./l CAT ITEM NOISUFFIA CODE DESCRIPTION . SYST .NETH REASON TO DIAM. l REMARKS B-A lB1.21 NR02 CLOSURE HEAD CIRC WELD Rx ' UT l092394 112.000 I 2-574 WELD (151 0-A B1.22 NR02 . CLOSURE HEAD MERIDIONAL Rx UT 1092994 87.000 L3-574A WELD (LENGTH DESCRIPTIONS WERE LISI B-A B1.40 NRC2 REACTOR HEAD TO FLANGE Rx UT ' 092494 228.000 EXAMINE THE FIRST 1/3 O* WELD 1-574 WELD ' I SI 0-A B1.40  :

NR02 REACTOR HEAD TO FLANGE Rx SUR - 092994 228.000 EXAMINE THE FIRST 1/3 OF WELD 1-574 WELD l ISI O-O !B3.100 NR02 N1A RECIRC OUTLET N0ZZLE RX UT ' 100594 26.000 3-565A WELD A-LOOP ISI 228.000 C-D 'B3.100 'NR02 N1B RECIRC OUTLET N0ZZLE RX UT 100594 26.000

3-565B WELD B-LOOP ISI 228.000 D-D B3.100 iNR02 N1C RECIRC OUTLET N0ZZLE RX UT 100594 26.000 3-565C WELD C-LOOP ISI 228.000 '

B-D B3.100 '

NR02 N1D RECIRC OUTLET N0ZZLE Rx UT 100594 26.000 '

l 3-565D WELD D-LOOP ISI 228.000 B-D fB3.100 NR02 N1E RECIRC OUTLET N0ZZLE Rx UT 100594 26.000 1 3-565E WELD E-LOOP ISI 228.000 0-D 183.100 lNR02 N3A MAIN STEAM N0ZZLE RX UT 100594 228.000 l6-566A WELD ISI 24.000 D-D B3.100 lNR02 N3B MAIN STEAM N0ZZLE RX UT 100594 228.000 l6-566B WELD 151 24.000 B-D B3.90 'NR02 N1A RECIRC OUTLET NOZZLE Rx UT 100594 26.000 13-565A WELD (A-LOOP ISI 228.000 B-D i B3.90 lNR02 N1B RECIRC OUTLET N0ZZLE Rx UT 100594 26.000 (3-565B WELD B-LOCp l ISI 226.000 0-D B3.90 lNR02 lNIC RECIRC OUTLET N0ZZLE RX LUT F100594 26.000 13-5650 WELD IC-LOOP ISI 228.000 B-D LB3.90 'NR02 lN1D RECIRC OUTLET N0ZZLE RA ! UT - 100594 26.000 1 3-565D WELD lD-LOOP ISI 228.000 0-D lB3.90 INR02 lNTE RECIRC OUTLET N0ZZLE Rx UT 100594 26.000 l 13-565E WELD E-LOOP . ISI 228.000 B-D 183.99 '

NR02 N3A MAIN STEAM NOZZLE RX UT 100594 228.000 6-566A WELD ISI 24.000 B-D '

B3.90 NR02 N3B MAIN STEAM NOZZLE RX UT 100594 228.000 u6-566B WELD ,151 24.000 B-F B5.10 NR02 N7A NOZZLE TO FLANGE Rx SUR . 092394 6.000 2-576 WELD IISI B-F B5.10 NR02 N7A NOZZLE TO FLANGE RX UT 092694 6.000 2-576 WELD ISI B-F B5.10 NR02 N1A RECIRC OUTLET NOZZLE RX (SUR 092094 26.000 4-565A WELD SAFE END ISI 26.000 0-F B5.10 NR02 -

N1A RECIRC OUTLET N0ZZLE RX UT 092294 26.000 WELD SAFE END l4-565A ISI 26.000

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION _DATE: 03/15/95

1. OWNER: Jersey Central Power & Light Company, thadison Avenus & PAGE: 0002 .

Punch Bowl Road. Eorristoen. Naw Jeesey

2. PLANT: Oyste* Creem Nucleaa Generatin9 Station.

U.S. Route 9. Forked River. New Jersey

3. PLANT UNIT: NA .

4 5.

OWNER CERTIFICATION OF AUTHORIZATION (if reautred): None COMMERCIAL SERVICE DATE: 12/23/69

6. NATIONAL BOARD NUMBER FOR UNIr= Reactor vessel 14895 007 AGE 15R TABLE 1 '

ID T ICATION l ASME ASME I EXAM TAG NUMBER CAT 1 ITEM NO.SUFFIM NDE l DATE/ FROM DIAM./ ,

CODE 1 DESCRIPTION l SYST METHlREASON TO DIAM.

--. ..------ - - _ - _ .___.....--......----- . REMARKS-B-F B5.10 :NR02 N1B RECIRC OUTLET N0ZZLE 4-565B WELD RX lSUR l0917941 26.000' SAFE END l151 1 26.000 B-F B5.10 NR02 N1B RECIRC OUTLET NOZZLE RX UT l091994 26.000 4-565B WELD SAFE END 'ISI 26.000 '

B-F B5.10 NR02 N1C RECIRC OUTLET N0ZZLE RM SUR 092294 26.000 4-5650 WELD l5AFE END '

B-F l85.10 NR02 ISI. 26.000 lNIC RECIRC OUTLET N0ZZLE RX UT 122092 26.000 l 4-565C WELD SAFE END ISI 26.000 B-F l B5.10 NR02 1 N1D RECIRC OUTLET N0ZZLE RX SUR 9091694 :

4-565D WELD 26.000.

SAFE END ISI 26.000  :

B-F .B5.10 NR02 NID RECIRC OUTLET N0ZZLE RX UT 091694 26.000 4-565D WELD SAFE END ISI 26.000 B-F B5.10 NRC2 lN1E RECIRC OUTLET N0ZZLE RX SJR 091694 '

26.000 4-565E WELD 5AFE END ISI 26.000 B-F B5.10 NR02 NIE RECIRC OUTLET N0ZZLE RX UT 092394 '

26.000 4-565E WELD SAFE END ISI 26.000 B-F B5.1C I NR02 N78 FLANGE TO NO2ZLE RX SUR 092394 6.000 4-576 WELD ISI D-F B5.10 NR02 N7B FLANGE TO N0ZZLE RX UT 092694 6.000

$4-576 WELD ISI i 0-F B5.10 lNR02 NB NOZZLE TO FLANGE RX SUR 092394 4.000 6-576 WELD l 151 i' B-F  ;

B5.10 NR02 ,NB NCZZLE TO FLANGE I RX UT 093094 4.000; 6-576 WELD ,

ISI

  • D-F FB5.t30 NU-1-0003 PIPE TO ELB0m NU UT . 101794 14. 0",.:

l WELD IISI l 14.000 B-F l85.130 NU-1-0003 PIPE TO elbow NU SUR 091894 14.000 WELD ISI 14.0001 0-F B5.130 NU-2-0002 ELB0w TO PIPE (BI-METALIC Nu (SUR 092194 14.000 SEE TABLE 2 WELD WELD) ISI 14.000 0-F B5.130 NU-2-0002 elbow TO PIPE (BI-METALIC NU UT (101794 14.000 WELD WELD) 'ISI 14.000 B-G-1 86.10 NR02 CLOSURE NUT (64) RX SUR : 092294 9.375 INSPECT NUTS 1-22 573-02 BOLT ISI B-G-1 86.180 !P-37-001 CAP SCREW COVER-TO CASE NG : VT-1 112394 -

2.750 BJ2-3 BOLT (SET OF 16) .

ISI B-G-1 B6.180 P-37-001 CAP SCREW COVER TO CASE NG UT 112594 2.750 l BJ2-3 BOLT (SET OF 16) PSI O-G-1 86.180 P-37-002 CAP SCREW COVER TO CASE ( NG UT l100494 2.750 BJ2-3 BOLT SET OF 16) ll l PSI D-G-1 86.180 P-37-003 CAP SCREW COVER TO CASE NG lVT-1 112394 2.750 IBJ2-3 BOLT (SET OF 16) ISI l C-G-1 86.180 lP-37-003 CAP SCREW COVER TO CASE NG UT 1125941 2.750 lBJ2-3 BOLT (SET OF 16) PSI l

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95' PAGE: 0003- e 1 OWNER: Jersey Central Power & Light Company. Mcdison Avenue &

Punch Bowl Roac.'Morristown. Ns= Jersey

2. PLANT: Oyster Creek huclear Generating Station.

U.S. Route 9. Forked River. Ne= Jersey *

3. PLANT UNIT: Na
4. OWNER CERTIFICATION Or AUTHORIZATION-fif required): None
5. COMMERCIAL SERVICE DATE: 12/23/69 '
6. NATIONAL BOARO NUMBED FOR UNIT: Reactor vesset 14895 ,

OUTAGE 15R TABLE 1 I IDENTIFICATION l EXAM '

ASME ASME I TAG NUMBER NDE DATE/ FROM DIAM./  !

CAT DITEM NOl SU*FIX CODE l DESCRIPTION SYSTLMETH REASON TO DIAM. REMARKS D-G-1lB6.190 IP-37-001 ' CAP SCREW COVER TO CASE NG VT-1 112594 2.750 l  : BJ2-3 BOLT (SET OF 16) ISI 9-G-1196.190  : D-37-003 CAP SCREW COVER TO CASE NG VT-1 112594 2.750 l BJ2-3 ' BOLT (SET OF 16) ISI B-G-1 8 6.20 NRO CLOSURE STUD (64) RX UT 091394 6.000 INSPECT STUDS 1-22 573-01 BOLT ISI 6.000 B-G-1 B6.200 P-37-001 CAP SCREW COVER TO CASE NG VT-1 112594 2.750 '

BJ2-3 BOLT (SET 08 16) PSI B-G-1' B6.200 up-37-002 CAP SCREW COVER TO CASE ( NG VT-1 100494 2.750 l BJ2-3 BOLT SET OF 16) PSI f B-G-1 96.200 P-37-003 .

CAP SCREW COVER TO CASE ~ NG VT-1 112594 2.750 _

(SET OF 16) 1 BJ2-3 BOLT PSI 5-G-1 B6.40 NR02  ; THREADS IN RX VESSEL FLAN RX UT 091394 229.000 INSPECT.THEADS IN FLANG 1-21 563-C2 BOLT GE ISI '

8-G-1 86.50 'NR02 THREADED BUSHING (64) RX IVT-1. 091394 INSPECT 1-21 4 573-06 BOLT .

ISI

  • D-G-1?B6.5C HR02 CLOSURE WASHER BOTTOM (64 RX VT-1 092294 INSPECT 1-22

' i l 573-07 BOLT ) ISI  :

B-G-1lB6.50 NR02 CLOSURE WASHER UPPER (64) .RX lVT-1 092294! . INSPECT 1-21 573-0BL BOLT . ISI ' (-

D-G-2 B7.70 V-1-0010 BONNET BOLTING MS VT-1 100594 - 2.000 :l BOLT PSI . '

B-G-2 B7.70 V-1-0010 BONNET BOLTING. MS VT-1 100694 '2.000 BOLT ISI B-G-2 'B7.70 V-1-0161 1 BONNET BOLTING MS VT-1 100394 BOLT ISI B-G B7.70 V-1-0162 BONNET SOLTING MS VT-1 100394 '

BOLT ISI B-G-2 B7.70 V-t-0164 BONNET BOLTING MS ' VT-1 100794 BOLT- PSI O-G-2 87.70- V-1-0165 .

BONNET 50LTING MS ~ VT-11100794l BOLT PSI

- D-G-2 87.70 V-1-0166 . BONNET BOLTING MS VT-1 100794 BOLT PSI l G-G-2 87.70 V-1-0167. BONNET BOLTING MS VT-1 100794 l l BOLT PSI-B-G-2 '97.70 V-1-0168 BONNET BOLTING MS VT-1 100794 BOLT PSI 9-G-2 87.70 - V-16-0133 BONNET SOLTING ND VT-1 092994 ~6.000 '

BOLT PSI-8-G-2 87.70 P-37-002 CAP SCREW COVER TO CASE ( NG VT-1 101094 2.750 THIS EXAM WAS-FOR THE SEAL COVER AS '

BJ2-3 SOLT SET OF 16) jPSI . SEMBLY (P-37-002 BJ10-13 BOLT) a-G-2 87.70 v-t-Oi73 BONNET s0LTING Nz vi-1lO91s94 BOLT l l PSI e -

e wA*w+a'- av- p-smr_w-e-WTwws--.ewMu-w -w ww +ww-erm.wa-g,wg.,,m,,c.gy-ey.-m.- ess eearsver@ w e -wve'*--c*ae-----J--'h--a -----=a --h-- - - - - - - - - - - - - - - - - - - - - - - -

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95 1 OWNER: Jersey Central Power & Light Company. Cadison Avenue & PAGE: 0004 .

Punch Bowl Road. Corristown. New Jersey

2. PLANT: Oyster Creek Nuclear Generatin9 Station.

U.S. Route 9 Forked River. New Jersey

3. PLANT UNITa NA
  • 4 OWNER CERTIFICATION Om AUTHORIZATION (if reouired): None
5. COMMERCIAL SERVICE DATE: 12/23/69 f
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor vessel 14895 OUTAGE ISR TABLE 1 l IDENTIFICATION l -l l 1

ASME ASME ITAG NUMBEP i- l EXAW I CAT- ITEM NOISUFFIX CODE INDE I DATE/l FROM DIAM./ i DESCRIPTION :SYSTlMETHlREASON!

__..... - = _ . . . . . . . . . . - - - --- --_ . __.....=_ - _ -

. ..__..._______TO DIAW. REMARKS D-G-2lB7.70 V-1-0175 ' BONNET BOLTING NZ VT-1 091694 I BOLT PSI B-G-2187.70 V-1-0176 BONNET BOLTING NZ VT- 1 ; 091694 BOLT IPSI B-G-2 B7.70 V-20-0015 BONNET BOLTING NZ 092294 VT  :

8.000 BOLT PSI B-G-2 B7.70 V-20-0021 CORE SPRAY SYS.2 PARALLEL NZ VT-1 100594 I BOLT '

ISOL VALVE SONNET BOLTING l ' PSI D-G-2LB7.70 V-20-0040 BONNET BOLTING l NZ VT-1 092294 8.000 BOLT i

] l PSI B-G-2 87.70 V-20-0041 IBONNET BOLTING . NZ VT-1 100594 -8.000 BOLT .

PSI B-G-2 B7.80 NCO2 CONTROL ROD DRIVE / GROUP 1 CRD VT-1 100894 14-27 CRDRVE PSI S-G-2 57.80 NCO2 ICONTROL ROD DRIVE / GROUP 2- CRD VT-1 100894 18-27 CRDRVE l PSI B-G-2 B7.80 l NCO2 CONTROL RCD DRIVE /GROUD 1 l'CRD VT-1l100894 18-35 CRDRVE l PSI-B-G-2 B7.80 NCO2 CONTROL ROD DRIVE / GROUP 3 CRD VT-1 100894 18-47 CRDRVE (PERIPHERAL) PSI B-G-2 87.80 NCO2 CONTROL ROD DRIVE / GROUP 11 CRD VT-1 '100894 18-51 .CRDRVE -(PERIPHERAL) .

. PSI B-G-2 B7.80 '

NCO2 CONTROL ROD DRIVE / GROUP 4 I CRD VT-1 100894 22-15 CRDRVE (PERIPHERAL) .- PSI.

B-G-2: 57.80 ,

NCO2 CONTROL ROD DRIVE / GROUP 2- CRD VT-1 100894 1 22-19 CRDRVE PSI B-G-2 B7.80  !

NCO2 CONTROL ROD DRIVE / GROUP-1 I CRD .VT-1 100894 22-27 CRDRVE l ( PERIPHER AL) : PSI B-G-2 87.80 NCO2 CONTROL ROD DRIVE / GROUP 2 CRDlVT-1 100894 26-27 CRDRVE . -

PSI B-G-2 B7.80 NCO2 .

CONTROL ROD DRIVE /GROUD 1 CRD VT-1 100894 30-27 CRDRVE .

PSI B-G-2 97.80 NCO2 CONTROL ROD DRIVE / GROUP 3 CRD VT-1 30-39 CRDRVE PSI

.B-G-2 87.80 NCO2 (CONTROL ROD DRIVE / GROUP 4 CRD VT-1 100894 34-39 CRDRVE PSI

-B-G-2 57.80 NCO2 CONTROL ROD ORIVE/ GROUP 3. CRD VT-1 100894 l 134-47 CRDRVE PSI e-G-2 87.80. INCO2. CONTROL-ROD DRIVE / GROUP.3' CRD VT-1 100894 142-31 -CRDRVE .

PSI B-G-2 87.80 lMCO2 CONTROL ROD DRIVE / GROUP 2 CRD VT-1 100894 142-43 CRDRvE PSI o-G-2 87.80 INCO2 BOLTING ON 137 CRD DRIVES 'NC VT-1 101794

~l SOLT (PSI.

NIS-1 OWNERS DATA REPORT.FOR INSERVICE INSPECTION- DATER ~03/15/95 PACE: 0005 '.

1 OWNER: Jersey Central Power & Light Company.'ICadison Avenus &'

Punch Bowl Road. ISorristown. Nsw Jersey

2. PLANT: Oyster Creek Nuclese Generating Station.

U.S. Route 9. Forked R9ver. New Jersey --

3. PLANT UNIT: NA 4 OWNER CERTIFICATION 05 AUTHORIZATION (if required): None
5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT + Reactor 'eessel 14B95 OUTAGE 15R TABLE 1 IDENTIFICATION l  !

l EXAM ASME ASME TAG NUMBEP NDE- DATE/ FROM DIAM./

CAT ITEM NO SUFFIX CODE DESCRIPTION SYST METH REASON TO DIAN. REMARKS D-J 89.11 lMS-1-0006 PIPE TO ELB0m MS lUT l092094' 24.000 WELD I ISI B-J 89.11 MS-1-0006 PIPE TO ELBOh MS 'SUR 092094 24.000 WELD ISI O-J '89.11 MS-1-0007 ELB0w TO PIPE MS UT 092094 24.000 WELD . 'ISI 9-J E9.11 MS-1-0007  : ELBOW TO PIPE MS (SUR 'l091994 24.000 'I WELD ISI D-J 89.11 MS-1-0008 PIPE TO elbow MS. UT 092094 24.000 WELD . ISI O-J 99.11 MS-1-0008 PIPE TO ELB0m MS SUR 091994 24.000 WELD ISI D-J 89.11 MS-1-0009 ELBOW TO PIPE -MS UT 092094 24.000 WELD ISI B-J 59.11 MS-1-0009 ELBOW TO PIPE MS SUR 092094 24.000 WELD . ISI-B-J 89.11 ND-10-0001 PIPE TO N0ZZLE 'ND UT 100394 6.000

. WELD  !!ISI 8-J 59.11 ND-10-0001 PIPE TO N0ZZLE ND 'SUR 091794 6.000 WELD ISI O-J 99.11 ND-10-0003 .

ELBOW TO ELB0h ND UT 100394 6.000 2

WELD ISI D-J 89.11 lND-10-0003 ELBOW TO ELBOW NO SUR 091794 6.000' WELD ISI I B-J 89.11 ND-10-0005 IPIPE TO VALVE ND lUT l100394 6.000, WELD _ IISI' B-J 89.11 ND-10-0005 PIPE TO VALVE. ' ND SUR 1091794 6.000 WELD IISI B-J l89.11 -

ND-10-0009  :

PIPE TO VALVE -ND UT' . 092094 6.000 i WELD l ISI 0-J ND-10-0009 PIPE TO VALVE 091794 59.11 l ND SUR 6.000 WELD j ISI .i

- B-J 199.11 ND-1-0008 PIPE-TO-ELBOW ND UT 100594 .'6.000 '

WELD .

ISI.

D-J 59.11 ND-1-0008 PIPE-TO-ELBOW ND SUR 092294 .6,000 WELD lISI D-J 89411 NO-1-0009 ELBOW TO PIPE ND UT l100594 ~6.000 i WELD lISI B-J 'B9.11 ND-1-0009 . ELB0w TO PIPE NO- SUR lO92294 6.000 WELD .

ISI B-J 199.11 NE-2-0054A PIPE TO PIPE NE SUR ' 091794 10.000 WELD ISI

- G-J 89.11 NE-2-0054A PIPE TO PIPE NE UT 100694 10.000 WELD l ISI

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95 r PAGE '0006 .

1. OWNER: Jersey Central Power & Light Campsny. Cadison Avenue &

Punch Bowl Road. Morristown. New Jersey .;

2. PLANT: Oyster Creek Nuclear Generatin9 Station. '

U.S. Route 9. Forked River. New Jersey .

3. PLANT UNIT: NA ,

4 OWNER CERTIFICATION 0* AUTHORIZATION (if required): None

5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT Reactor vessel 14895 i

OUTAGE 15P i TABLE i '

IDENTIFICATION '

]

EXAM i ASME ASME TAG NUMBEP NDE '

DATE/ FROM DIAM./

l CAT l ITEM NOISUFFIX CODE l DESCRIPTION  : SYST' METHIREASON TO DIAM. REMARK 5 r

. ______________________..._-- _ _ _ _ _ _ _ _ . . . _ _ - =

8-J lB9.11 NE-2-0061 PIPE TO VALVE NE 'OT 100594 10.000) SEE TABLE 2 WELD ISI i 9-J 59.11 NE-2-0061 PIPE TO VALVE NE SUR 091894 10.000 WELD ISI B-J 89.11 NE-5-201 PIPE TO ELB0w NE UT 100394 10.000 WELD ISI i B-J 89.11 NE-5-201 PIPE,TO ELBOW- NE SUR 092794 10.000 '

WELD RISI B-J 99.11 NG-A-0025 ELB0w TO PIPE NG UT 100194 26.000 WELD ISI 8-J 89.11 NG-A-0025 ELBDw TO PIPE NG SUR 092194 26.000 ,

WELD I .

ISI 8-J 89.11 NG-B-0002 ELBOW TO PIPE NG UT 092794 26.000 WELD ISI B-J 89.11 NG-B-0002 ELBOW TO PIPE NG SUR "092394 26.000 WELD ISI B-J 59.11 NG-C-0002 ELBOW TO PIPE NG UT 26.000 WELD '

ISI B-J $89.11 NG-C-0002 ELBOW TO PIPE NG SUR 092194 26.000 WELD ISI l D-J 59.11 NG-E-0026A PIPE TO SAFE END NG UT 100494 26.000 WELD .

ISI 26.000 B-J 89.11 .

NG-E-0026A '

PIPE TO SAFE END NG l$UR 092894 26.000 WELD .

ISI 26.000 B-J 99.11 NU-1-0016 IPIPE TO ELB0w NU UT 081294 14.000 WELD I ISI S-J 89.11 NU-?-0016 l PIPE TO ELB0m NU SUR 090794 14.000 SEE TABLE 2- i l WELD ISI D-J . ' 89.11 lNU-1-0018- ELB0w TO PIPE NU UT ' 081194 14.000 i WELD ISI B-J 59.11 NU-1-0018 i ELBOW TO PIPE NU SUR  :

090794 14.000 SEE TABLE 2 WELD ISI '

B-J 59.11 NU-2-0022 .

ELBOW TO PIPE- NU UT 080994 8.000 WELD .

. 157 B-J 89.11 NU-2-0022 elbow TO PIPE NU SUR 080894 8.000 WELD ISI 0-J B9.11- NU-2-0029 ELBOW TO PIPE NU SUR . 080894 8.000  !

WELD I 'lISI '

B-J. 89.11 NU-2-0029 ELBOW TO PIPE NU UT 081194 8.000 l WELD ISI 7

i 5-J 89.11 NU-3-0002 ELBOW TO PIPE l NU UT ' 101794 14.000 WELD ISI S-J 89.11 NU-3-0002 ELB0w TO PIPE NU SUR 091894 14.000 WELD ISI

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/05

- PAGE: 0007 .

1 OWNER: Jersey Central Powar & Light Company, Ccdtsen Avseue &

Punch Bowl Road. Morristown. New Jersey ,

2. PLANT: Oystee Creek Nuclear Generat9n9 Station, U.S. Route 9. Forked River, New Jersey .-
3. PLANT UNIT: NA
4. OWNER CERTIFICATION OF AUTHORIZATION (i* reautred): None
5. COMMERCIAL SERVICE DATE: 12/23/69 G. NATIONAL BOARD NUMBER FOR UNIT: Reactor vesset 14895 l OUTAGE 15R TABLE 1

___________.....___.____..____.._____ ........__.....___.....___....___......___... ... .- ..= -_

i l IDENTIFICATION l i l s l EXAM l ASME ASME ' TAG NUMBER l HNDE DATE/ FROM DIAM./l CAT H ITEM NO SU*FIM CODE l DESCRIPTION ISYSTlMETH REASON l TO DIAM. 1 REMARKS

. . . . . . . . . . _ _ _ _ . . . . _ . . . . _ . . . . . _ _ _ . _ . _____-_ ...____. .......__.- ==__ --- - _ . _ _ -

S-J IB9.11 'NU-3-0004 l ELBOW TO PIPE NU JUT 101894 14.000!

) .

WELD I I ISI B-J '89.71 NU-3-0004 ELBOW TO PIPE NU .SUR 092694 14.000

  • WELD ISI 9-J 89.11 NZ-3-0091 PIPE TO ELBOW NZ UT 091894 8.000 WELD ISI B-J 89.11 NZ-3-0091 LPIPE TO ELBOW NZ SUR 091894 B.000 WELD l ISI O-J 89.11 URMC-HS-2 l FLANGE TC REDUCER Rx SIDE RHC UT 093094 6.000 WELD l ISI B-J 89.11 RNC-MS-2 FLANGE TO REDUCER RX SIDE RHC . SUR 092594 '6.000 l WELD ISI B-J EHi.11 RHC-2-0040A  : elbow TO PIPE RHC UT 081694 6.000 WELD '

ISI I B-J -

89.11 RMC-2-0040A ELBOW TO PIPE RHC SUM l091294 6.0001 WELD ISI D-J B9.12 i MS-1-00064 LONGITUDINAL WELD ON EXTR MS UT 092094 26.000 -t WELD .

ADOS OF ELBOW ISI B-J 89.12 MS-1-00064 LONGITUDINAL WELD ON EXTR MS ISUR 092094 26.000 WELD ADOS OF elbow ISI B-J 89.12 MS-1-00068 LONGITUDINAL WELD ON INTR MS UT 092094 26.000 WELD ADOS OF ELBOW ISI D-J 89.12 MS-1-0006B lLONGITUDINAL WELD ON INTR MS SUR 092094 26.000 .

WELD ' ADOS 0* ELB0h ISI 9-J '89.12 MS-1-0008A LONGITUDINAL WELD ON EXTR MS. UUT 092094 26.000 l WELD ' ADOS Or ELBOm ISI B-J 189.12 MS-1-0008A LONGITUDINAL WELD ON EXTR ' MS SUR s092094 26.000 l WELD ADOS 05 ELB0w 'l ISI 9-J 189.12 MS-1-0008B LONGITUDINAL WELD ON INTR I MS lUT 0920942 26.000' WELD ADOS 08 ELB0m ISI B-J 1 89.12 MS-1-0008B LONGITUDINAL WELD ON INTR MS SUR 092094 .

26.000 WELD  :

ADOS OF elbow ISI U-J 89.12 IND-10-00024 LONGITUDINNAL WELD ON EXT ND UT 091694 6.000 WELD RADOS 0* elbow 1 ISI B -J 89.12 ND-10-0002A LONGITUDINNAL WELD ON EXT ND - SUR 091794 6.000 WELD RADOS OF elbow' ISI 8-J 89.12 ND-10-00028 .

LONGITUDINNAL WELD ON INT ND UT- 091694 6.000 WELD IRADOS OF ELB0w l- ISI E-J 99.12 ND-10-0002B 'LONGITUDINNAL WELD ON INT ND SUR 091794 6.000 i WELD RADOS OF ELB0w l ISI B-J 89.12 ND-10-0004A LONGITUDINNAL WELD ON EXT l . ND UT 091694 6.000 WELD RADOS OF ELBOW l ISI 9-J 89.12 ND-10-0004A LONGITUDINNAL WELD ON EXT ND SUR v091794 6.000 WELD RADOS OF elbow lISI I

___._..-____m_m______.__._-_._.______.___.m__-_._._..________.________..a.m____-___ awm._ . _ . _ - _ - . _ . _ _ _ _ . - _ _ _ _ _ _ _ _ _ - - _ _ _ __-._.m m-__&--_1---.-.__m _______._.__am ._ _ _ _ _ _ _ _-

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95 PAGE: 0008 .

1. OWNER: Jersey Central Power & Light Company. Codison Avenus &

Punch Bow 1 Roed. Eorristown. Nam Jersey

2. PLANT: Oyster Creek Nuclear Generatin9 Station, U.S. Route 9 Forked River. New Jersey .
3. PLANT UNIT: NA 4 OWNER CERTIFICATION OF AUTHORI2ATION (if required): None
5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUwSER FOR UNIT: Reactor vessel 14895 OUTAGE 15R '

TABLE 1 l IDENTIFICATION 1 EXAM *

- ASME l ASME - TAG NUWBER NDE DATE/ FROM DIAM./

CAT l ITEM NOL5UFFIx CODE DESCRIPTION SYST. METH REASON TO DIAM. REMARKS

...__......_.._____......___...__..__........_____......... ............. .......__.-..-===- = = = . - =...____.....___ ........

B-J 89.12 I ND*10-00048 lLONGITUDINNAL WELD ON INT ND UT '091694 6.000 WELD RADOS OF ELBOW 'ISI B-J 89.12 ND-10-0004B LONGITUDINNAL WELD ON INT ND SUR . 091794 6.000 WELD RADOS OF ELBOW ISI 9-J 89.12 ND-1-0008A lLONGITUDINNAL WELD ON EXT ND UT 092394 6.000 WELD lRADOS 05 ELBOW ISI D-J 89.12 IND-1-0008A lLONGITUDINNAL WELD ON EXT ND SUR 092294 6.000 l WELD lRADOS OF ELBOW . ISI B-J 89.12 lND-1-CD08B JLONGITUDINNAL WELD ON INT ND UT 092394 6.000 l WELD RADOS OF ELBOW ISI B-J 59.12 lND-1-0008B LONGITUDINNAL WELD.ON INT ND SUR 092294 6.000 WELD RADOS Os ELBOW ISI B-J B9.12 NE-2-00548 LONGITUDINAL WELD ON PIPE NE UT 091794 10.000 WELD ISI 0-J 89.12 NE-2-0054B LONGITUDINAL WELD ON PIPE NE SUR 091794 10.000 WELD ISI B-J 89.12 NE-2-0054C LONGITUDINAL WELD ON PIPE NE UT 091794 10.000 WELD ISI O-J B9.12 NE-2-0054C LONGITUDINAL WELD ON PIPE NE SUR 091794 10.000 WELD ISI B-J 99.12 NE-5-0009A l LONGITUDINAL WELD ON PIPE NE UT 092894 10.000 WELD ISI D-J i 89.12 NE-5-0009A LONGITUDINAL WELD DN PIPE NE SUR 092894 10.000 WELD . .

ISI '

D-J 89.12 NE-5-0201A LONGITUDINAL WELD ON EXTR NE ISUR . 092894 10.000 WELD ADOS OF ELBOW lISI B-J 89.12 NE*5-0201A LONGITUDINAL WELD ON EXTR NE. UT 092894 10.000 WELD ADOS OF ELBOW ISI B-J 59.12 NE-5-0201B LONGITUDINAL WELD ON INTR NE ' UT ; 092E94 10.000 WELD ADOS OF ELBOW ISI B-J 89.12 NE-5-02018 .

LONGITUDINAL WELD ON INTR NE SUR l092894 10.000 WELD ADOS OF ELBOW IISI B-J 59.12  :

NG-B-0001B LONGITUDIAL WELD ON EXTRA NG SUR 091794 26.000 WELD DOS OF ELBOW ISI B-J 89.12 NG-B-0001B LONGITUDIAL WELD ON EXTRA NG UT 092194 26.000 D-J WELD DOS OF ELBOW IISI-89.12 NG-B-0001C LONGITUDINAL WELD ON INTR NG UT 092194 26.000 WELD ADOS OF ELBOW ISI~

B-J 89.12 NG-B-0001C LONGITUDINAL WELD ON INTR NG SUR 091794 26.000 WELD ADOS OF ELBOW ISI 0-J .59.12 NG-B-0002A LONGITUDINAL WELD ON PIPE NG UT (092394 26.000 WELD .

ISI D-J lB9.12 NG-B-0002A LONGITUDINAL WELD ON PIPE NG SUR 092394 26.000 l WELD '

ISI

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION . DATE: 03/15/95 +

- PAGE: 0009 . !

1. DINER: Jersey Central Power & L19ht Company. Madison Avenus & '

Punch Eowl Rocd. Corristown. N2e Jersey

2. PLANT: Oyster Creek Nuclear Generating Station.

U.S. Route 9 Forked River. New Jersey -

3. PLANT UNIT: NA 4 OWNER CERTIFICATION OF AUTHORIZATION (if reouired): None
5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUWBER FOR UNITt Reactor Vessel 14895 OUTAGE 15R TABLE 1 I l IDENTIFICATION t EXAU ASME ASME TAG HUMBER .

NDE DATE/ 'FROM DIAM./

CAT ITEU NO SUFFIX CCDE DESCRIPTION l$vsT!wETH: REASON TO DIAM. REWARKS ,

D-J B9.12 NG-C-0001B lLONGITUDINAL WELD ON EXTR UT l092294 NG 26.000 WELD LADOS OF ELB0m $151 B-J l 89.12 NG-C-0001B  :

LONGITUDINAL WELD ON EXTR 'NG SUR 1092194 26.000 WELD ADOS OF ELBOW  : ISI 9-J B9.12 NG-C-0001C LONGITUDINAL WELD ON INTR NG UT - 092294 26.000 WELD ADOS OF ELBOW ISI 0-J B9.12 NG-C-0001C LONGITUDINAL WELD ON INTR NG SUR 092194 26.000 .

WELD (ADOS OF ELBOW ISI B-J B9.12 NG-C-0002A LONGITUDINAL WELD ON PIPE NG UT ' 092294 26.000 WELD -

'ISI B-J '

99.12 NG-C-0002A LONGITUDINAL WELD ON PIPE NG SUR 092294 26.000 '

WELD ISI 0-J 89.12 NG-D-0001B LONGITUDINAL WELD ON EXTR NG UT 091994 26.000 WELD ADOS OF ELBOW ISI B-J 89.12 NG-D-0001B LONGITUDINAL WELD ON EXTR NG SUR 091594 26.000 WELD ADOS OF ELBOW ISI 0-J B9.12 NG-D-0001C LONGITUDINAL WELD ON INTR NG UT 091994 26.000 WELD  :

ADOS OF ELBOW ISI 9-J B9.12 NG-D-0001C -

LONGITUDINAL WELD ON INTR NG SUR 091694 26.000 WELD I ADOS OF ELBOW ..

ISI B-J 89.12 NG-E-0025A LONGITUDINAL WELD ON PIPE NG UT ' ; D92894 26.000 WELD (ISI a

B-J 89.12 NG-E-0025A LONGITUDINAL WELD ON DIPE. ..NG SUR 1092894 26.000 WELD lISI G-J l B9.12 NZ-3-0090A LONGITUDINAL WELD ON PIPE NZ UT 1091894 8.000 WELD lISI i D-J 59.12 NZ-3-0090A LONGITUDINAL WELD ON DIPE NZ SUR 091894 B.000 WELD ISI B-J 89.12 NZ-3-0091A LONGITUDINAL WELD ON EXTR NZ UT 091794 B.000 WELD l ADOS OF ELBOW ISI t D-J 89.12 NZ-3-0091A LONGITUDINAL WELD ON EXTR- NZ SUR 091794 B.000 WELD ADOS OF ELBOW HISI B-J 89.12 NZ-3-00918 LONGITUDINAL WELD ON INTR NZ UT- 091794 8.000 WELD ADOS OF ELSDW ISI D-J 89.12 NZ-3-00918 LONGITUDINAL WELD ON INTR NZ ISUR. 091794 B.000 WELD ADOS OF ELBDW ISI B-J IB9.21 NC-4-0014 ELBOW TO PIPE _NC SUR 092094 . 3.000 WELD ISI B-J 89.32 NU-2-0040 PIPE TO BRANCH NU MT 081994 1.250 WELD -

ISI G-J 89.40 MS-9-0031 ELBOW TO PIPE MS SUR 091794 2.000 WELD ISI O-J 89.40 'lMS-9-0033 TEE TO PIPE SOCKT MS ISUR 091794 2.000 l WELD l- -

ISI 4

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.____..______-________m_ _ _ _ _ . ._-__._____m___ _-m-.. - -v- . *.--,w--,-,,---,-w.-,- .%-* -r-_-=,-w--,,+w-e._..e 4- wwm-,- m:, w-- ,t w w, y-,,,..,--.-__.,,w--_-s,

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95 PAGE: 0010 .

2 1 OWNER: Jersey Central Power & Light Company. Madison Avenue &

Punch Bowl RoGd. Corristown. N3e Jersey .

2. PLANT: Oyster Creek Nuclear Generatin9 Statton.

U.S. Route 9. Forked River. New Jeesey * *

3. PLANT UNIT; NA
4. OWNER CERTIFICATION Or AUTHORIZATION (if reouired): None
5. COMMERCIAL SERVICE DATE: 12/23/69 6; NATIONAL BOARD NUMBEA FOR UNIT: Reactor vessel 14895 OUTAGE ISP TABLE 1 l IDENTIFICATION l 4

EXAM ASME ASME l TAG NUMBED 1NDE DATE/ FROM DIAM./

CAT ITEM NO SUFFIX CODE i DESCRIPTION SYSTlWETHl REASON TO DIAM. REMARKS

... _......_ . __.. _...._...... _ . ..._............................_ .=- - - --

D-J B9.40 INV-5-0011 elbow TO PIPE SOCKT WV SUR 1092794  !

WELD 'ISI D-J B9.40 MV-5-0012 PIPE TO elbow SOCKT WV SUR 092894 WELD ISI B-J 89.40 MV-5-0037 PIPE TO VALVE SOCKT Mv- PT 110294 WELD PSI G-J 89.40 MV-5-0038 VALVE TO PIPE SOCKT I MV PT 110294 .

WELD IPSI

' B-J '89.40 NG-B-0030 l TEE TO PIPE SOCKT NG SUR 1092094 2.000 WELD ISI B-J 99.40 NG-C-0025 PIPE TO elbow NG SUR 092094 2.000 SEE TABLE 2 WELD ISI 9-J 89.40 NG-D-0035 PIPE TO PIDE NC SUR 092094 2.000 WELD . ISI O-J 89.40 NP-2-0008 REDUCING TEE TO PIPE SOCK l NP SUR 092994 '

1.500 WELD 'T ISI O-J 89.40 NP-2-0023 elbow TO PIPE SOCMT Np SUR 091794 1.500 WELD ISI 0-J l 99.40 ND-2-0024 PIPE TO elbow SOCMT Np SUR 091794 1.500 I WELD ISI B-J :59.40 NP-2-0025 ELB0w TO DIPE SOCMT NP SUR 091794 1.500 WELD ISI 0-J B9.40 RHC-2-0012 .

elbow TO PIPE SOCMT RHC SUR 092594 2.000 WELD I ISI B-J 89.40. RHC-2-0018 ELBom TO PIPE SOCKT RHC SUR 092594 2.000 WELD ISI B-J 89.40 RHC-2-0060 .

PIPE TO FLANGE SOCMT RHC PT 102194 2.000 WELD PSI D-J '99.40 RHC-2-0061 elbow 90 TO PIPE SOCKT RHC PT 102194 2.000 WELD PSI B-J 89.40 RHC-2-0062 PIPE TO ELBOW 90 SOCMT- RNC PT , 102194 2.000 WELD I 'lPSI B-J 59.40 lRHC-2-0063 VALVE TO PIPE'SOCMT RMC PT l102194 2.000 WELD j l PSI 9-J 89.40 RMC-2-0064 PIPE TO VALVE SOCET RHC PT 102194 2.000 WELD . PSI B-J 59.40 RHC-2-0065 2* COUPLING SW TO PIPE RMC PT 102194 2.000 WELD i PSI

. 0-J 89.40 RMC-2-0066 PIPE TO 2" COUPLING -Sw RHC PT 103194 2.000 WELD PSI B-K-1 510.10 .x-003B iPIPING PENETRATION FOR NE SUR 091294

'NE-5-0211 WELD lEMERG.COND. STEAM SUPPLY lAUG 9-K-1 510.10 1211-BP-X-38-SS-1-0039 lNE-5-10" MECHANICAL PIPE NE PT l092494 l lA SUPORT l SNUBBER (NE-5-53) l PSI

NIS-1 DwNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/95 '

PAGE: 0011 -

1. OWNER: Jersey Central Powsr & Light Company. Madison Avenus &

Punch Dont Road. Morristown. New Jersey

2. PLANT: Oyster Creek Nuclear Generatin9 Station.

U.S. Route 9. Forked River. Ne= Jersey *

3. PLANT UNIT: NA 4 OWNER CERTIFICATION OF AUTHORIZATION (if required): None
5. COMMERCIAL SERVICE DATE: 12/23/69-
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor vessel 14895 OUTAGE 15R TABLE 1

_=__ _- --- ............................- _ ..................... ......

IDENTIFICATION }

} . EXAW ASME ASME TAG NUMBER l  !

NDE DATE/ FROM DIAM./

CAT . ITEM NO SUFFIM CODE l DESCRIPTION SYSTIMETH REASON TO DIAM. REMARKS

. _.-- -_.... ......... ...=- .._ ._................................. ..........- ......................... ........

0-A-1 810.10 (211-BP-x-38-SS-1-0039 jNE-5-10" MECHANICAL PIPE NE PT l092494L B SUPORT J SNUBBER (NE-5-54) IPSI

  • B-L-2 B12.20 P-37-002 REACTOR RECIRCULATION PMP NG VT-31100794 '

PUMP NG01-B 'lISI '

D-L-2 B12.20 P-37-005 REACTOR RECIRCULATION PMP NG IVT-3 l120794 PUMP .

NG01-E l ISI B-M-2 B12.50 V-16-0133 -

V-16-1 TEST BARRIER VALVE ND IVT-3 093094 6.000 VALVE 'ISI B-M-2 B12.50 V-14-0030 .

STEAM INLET VALVE TO *A* NE VT-3 100394 10.000 VALVE EMERGENCY CONDENSER ISI I D-M-2 B12.50 V-14-0031 STEAM INLET VALVE TO 'A' NE jVT-3 100794 l 10.000 VALVE EMERGENCY CONDENSER ISI B-N-2 B12.5C V-14-0032 STEAM INLET VALVE TO 'B' NE VT-3 100894 10.000 VALVE ENERGENCY CONDENSER '

PSI B-M-2 B12.50 V-14-0033 ISTEAM INLET VALVE TO 'B* NE VT-3 100394 10.000 VALVE LEMERGENCY CDMDENSER ISI D-M-2 B12.50 V-14-0035 ' EMERGENCY CONDENSER NE01B NE VT-3' 063094 10.000 VALVE CONDENSATE RETURN VALVE ISI D-M-2 B12.50 V-20-0015 CORE SPRAY SYS.I PARALLEL NZ VT-3' 092294 B.000 VALVE IISOLATION VALVE IISI D-M-2 B12.50 V-20-0021 CORE SPRAv'SYS.2 PARALLEL NZ VT-3 '100594 B.000 VALVE ISOLATION VALVE ISI D-M-2l B12.50 V-20-0041 CORE SPRAY SYS.2 PARALLEL NZ VT-3 100794 B.000 l VALVE ISOLATION VALVE PSI  !

O-N-1 LB13.10 NR02 HEAD CLAD RX : VT-3 100194 NRO2-B INTER ISI B-N-2 813.40 NRO2 SHROUD TOP GUIDE SUPPOR RX VT-3 101494 H-2 WELD T RING ISI D-N-2; B13.40 NR02 SHROUD TOP GUIDE SUPPOR RX VT-3 092594 N-3 WELD T RING ISI B-N-2 'B13.40 NR02 SHROUD LOWER INTERMEDIA RX - VT-3 100994 H-6A WELD TE RING ISI B-N-2 B13.40 NR02 TOP GUIDE RX VT-3 100794 SEE TABLE 2

! INTER-L VESSEL AUG B-N-2 'B13.40 NR02 CONICAL SUPPORT RX VT-3 101594 INTER-P VESSEL ISI B-N-2' B13.40 NR02 CORE SUPPORT ASSEMBLY CON RX VT-3 101194 4-564 WELD ICAL SUPPORT TO VESSEL H- ISI 0-P B15.10 NR02 1 REACTOR VESSEL RX VT-2 112594 .!

VESSEL ISI j 0-P B15.50 214 ' SHUTDOWN COOLING NU VT-2 092194 PIPE- SYSTEM-PIPING ISI C-F-1 C5.11 NE-1-203 PIPE TO PIPE NE UT ' 092494 16.0001 WELD lISI 16.000l

_ _ _ _ _ _ _ . _ _ _ ._ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ . _ _ _ _ . _ _ _ _ _ __ _______m. - _ _ _ _ _ . _ _ . . , . _ . _ _ . - . . _ _ , , . _ , . _ _ - _ . . . _ , , . _ _ _ _ _ _ _ _ _ _ _ . . _ _ _ _ - . _

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE 03/15/05 PAGEs 0012 . ,

1. OWNER: Jersey Central Power & Light Csepany. Ecdtson Avenue &

Punch Bowl Roed. Corristown. N3w Jersey

2. PLANT: Oyster Creek Nuclear Generatin9 Station.

U.S. Route 9. Foebed River. New Jersey -

3. PLANT UNITt NA 4 OWNER CERTIFICATION OF' AUTHORIZATION (if recuired): None
5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NU#SER FOR UNITt Reactor vessel 14895 OUTAGE 15D TABLE 1  ;

.-- .-- - . . . . . . . . . - - . . . . . . . . . . - . . . . - . - . . . . . . . . . - . . . . . . . . . . . - - . . . . . . . . . . . . . . . . . . . . . . . . . . - - . . . - - - - . . . . . . . . . . . . . . . - - - - - = =-=- _

IDENTIFICATION l l EXAW ASME ASME TAG NUMBER i {NDE DATE/

FROM DIAM./

CAT i! TEM NO SUFFIX CODE DESCRIPTION ISYSTlMETH REASON! TO DIAW. l REWARM.S ,

C-5-1 C5.11 'NE-1-203 PIPE TO PIPE NE SUR :092494 16.000 WELD ISI- 16.000 C-F-1 C5.11 NE-1-210 PIPE TO N0ZZLE A CONDENSR NE UT 091494 12.000 NORTM END 05 COND. A WELD 152 C-F-1 C5.11 NE-1-210 PIPE TO N0Z2LE A CONDENSR NE SUR 092894 12.000 SEE TABLE 2 WELD lISI C-F-1lC5.11 NE-1-219 PIPE TO WYE NE SUR 091494 16.000 ,

WELD ISI t C-F-t C5.11 NE-1-219 PIPE TO WYE NE UT 091494 16.000 '

WELD ISI C-F-1 C5.11 NE-1-220 wvE TO PIPE NE l UT 091494 12.000 WELD ,

ISI i C-F-1 C5.11 NE-1-220 WYE TO PIPE NE ISUR 091494 12.000

-WELD I ISI C-F-1 C5.11 '

NE-1-221 PIPE TO PIPE NE UT 092394 12.000 WELD ISI C-F-1 C5.11 NE-1-221 PIPE TO PIPE NE SUR 092394 12.000 WELD ISI C-F-1 C5.11 NE-2-201 ' NOZZLE TO PIPE A CONDENSR NE SUR 091594 8.000 NORTH END OF COND. A WELD ISI C-F-1 C5.11 NE-2-201 N0ZZLE TO PIPE A CONDENSR NE UT 091494 8.000 NORTH END OF COND. A WELD ISI i +

C-F-1 C5.11 NE-2-233 PIPE TO PIPE '

NE UT l0913941 8.000 WELD lISI i  !

C 8-1lC5.11 NE-2-233 . PIPE TO PIPE I NE SUR 10914941 8.000  ;

I WELD ISI C-F-2lC5.51 NQ-2-0006 PIPE TO EL80m NQ UT 072194 10.000 WELD -

AUG C-F-2 C5.51 NO-2-0006 PIPE TO ELBOW NQ ; SUR ' 072194l 10.000 WELD AUG C-F-2 C5.51 NO-2-0021 PIPE TO ELBOW NQ UT 081594 14.000 WELD ISI-C-F-2 C5.51 NQ-2-0021 IPIPE TO ELBOW NQ SUR 081494 14.000 WELD  : ISI C-F-2 C5.51 NQ-2-0134 ELBOW TO REDUCING TEE NQ (UT 072194 6.000 SEE TABLE 2 WELD AUG C-F-2 C5.51 NO-2-0134 IEL50w TO REDUCING TEE NQ SUR- 091794 6.000 SEE TABLE 2- '

WELD AUG C-F-2 C5.51 NO-2-0162. EL90w TO PIPE NO UT - 072894 14.000 WELD ISI' C-F-2 C5.51 NO-2-0162 ELBOW TO PIPE NQ ISUR 072894 14.000 WELD l l ISI C-F-2 C5.51 NQZ-1-0020 PIPE TO PIPE l.NQZlUT 080394 20.000 .

, WELD l l. lISI l i

i j

di

____---.--m_.-..---_----..w m-.m..,--<...,~._w.,.me~... -,w-~._._ ..--.-__#- ~ , . . . - -

NIS-1 OWNE35 DATA REP 03T FOR INSERVICE INSPECTION DATE: 03/15/95 PAOE: C013

1. OWNER: Jersey Control Powsr & Lig5t Camp:ny. Ecdtsen Avenus &

Punch Bowl Road. Morristown. New Jersey ,

2. PLANT: Oyster Creek Nuclear Generating Station.

U.S. Route 9. Forked River. New Jersey ,

3. PLANT UNIT: NA 4 OWNER CERTIFICATION OF AUTHORIZATION (if reoutred): None
5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUM8ER FOR UNIT
  • Reactor vessel 14895 OUTAGE 15R ,

TABLE 1 IDENTIFICATION EXAM ASME ASME l TAG NUM8ER NDE DATE/ FROM DIAM./

CAT l! TEM NOISUFFIx CODE DESCRIPTION SYST METH REASON TO OIAM. REMARKS i C - F - 21 C5.51 lN02-1-0020 PIPE TO PIPE N0Z SUR 080394 20.000 l WELD ISI C-F-2 C5.51 NZ-1-0013 VALVE TO PIPE NZ UT 082494 12.000 1 WELD ISI C-F-2 C5.51 NZ-1-0013 VALVE TO PIPE NZ SUR 072794 12.000 WELD . ISI C-F-2 C5.51 NZ-1-0018 TEE TO PIPE NZ UT 082394 12.000 SEE TACLE 2 WELD ISI +

C-F-2 C5.51 NZ-1-0018 TEE TO P1PE NZ SUR 072794 12.000 l WELD ISI I C-F-2lC5.51 NZ-2-0232 PIPE TO EL8OW NZ SUR 080594 10.000

' WELD AUG C-F-2 C5.51 NZ-2-0232 PIPE TO ELBOW NZ UT 080494 10.000 WELD AUG C-F-2 C5.51 .NZ-2-0233 ELBOW TO ELBOW NZ SUR. 080594 10.000 l WELD AUG

C-F-2lC5.51 NZ-2-0233 ELBOW TO EL8OW NZ UT 081994 10.000 WELO AUG l NZ SUR 080494 10.000 C-F-2lC5.51 NZ-2-0234 ELBOW TO ELBOW l WELD AUG C-F-21 C5.51 NZ-2-0234 lEL80w TO ELBOW NZ UT 080894 10.000  ;

, WELD 'AUG SUP 1080594 -10.000 C-F-2 C5.51 INZ-2-0235 EL8OW TO PIPE NZ l WELD AUG  !

10.000 l

< C-F-2lC5.51 INZ-2-0235 ' ELBOW TO PIPE NZ UT I WELD AUG SEE TABLE ~

C-F-2 C5.51 NZ-2-0235 ELBOW TO PIPE NZ UT 083094 1,0f 000 WELD ISI b C-F-2 C5.51 RF-2-0078 VALVE TO PIPE RF SUR ' 091494 14.D00 WELD ISI 14.000' C-F-2 C5.51 RF-2-0078 VALVE TO PIPE RF UT 091594 14.000 WELD ISI 14.000 C-H C7.30 541 REACTOR BUILDING CC IVT-2. 092194 PIPE l CLOSED CLG WTR SYS-PIPING ISI C-H C7.30 411 MAIN STEAM MS VT-2 090994

  • PIPE SYSTEM-PIPING 'ISI '

C-H C7.30 225 CONTROL ROO DRIVE SYSTEM NC VT-2 070794 SYSTEM 15 ISI i NC VT-2 070794 C-H lC7.30 225 CONTROL ROD DRIVE SYSTEM l NC-3 PIPE - PIPING NC-3 ISI .

C-H C7.30 211 EMERGENCY CONDENSER NE IVT-2 070694 .

NE-1 PIPE SYSTEM-PIPING NE-1 ISI C-H C7.30 241 CONTAINMENT SPRAY NQ VT-2 082994 I PIPE PIPING ISI i 1 -

NIS-1 OWNERS DATA CEPO37 FOR INSERVICE INSPECTION DATE: 03/15/93 PAGE: 0014 .

1. OWNER: J3rsey C6ntral Pow 2r & Li9ht Compsny. Ccdison Avenue &

Punch Bowl Road. Morristown. New Jersey

2. PLANT: Oyster Creek Nuclear Generatin9 Station.

U.S. Poute 9. Forked River. Nem Jersey -

3. PLANT UNIT: NA 4 OWNER CERTIFICATION 08 AUTHORIZATION (1* reouired): None
5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vessel 14895 OUTAGE 15R TABLE 1 l l IDENTIFICATION I i

! l  ! EXAM ASME i A5ME ' TAG NUuBER I NDE DATE/ FROM DIAM./

CAT l ITEM NO SUSFIk CODE  ! DESCRIPTION lSv5T METH ' REASON TO DIAM. REMARKS C-N IC7.30 !241 (CONTAINMENT SPRAY SUCTION l NQ DVT-2l092294 lN02-1 PIPE l HEADER PIPING l lISI C-H C7.30 214 (CLASS 2 PORTION Or THE SH NU VT-2lO91394 B-LOOP SYSTEM IUTDowN COOLING SYS 1151 C-H C7.30 :214 1 CLASS 2 PORTION OF THE SH NU VT-2 lO91394 C-LOOP SYSTEM luTDOWN COOLING SYS ISI C-H C7.30 212 (CORE SPRAY & AUTOMATIC NZ VT-2 071894 NZ-2 PIPE '

DEPRES. SYSTEM-PIPING N2-2 -

ISI C-H C7.30 422 FEEDwATER SYSTEM R* VT-2 l O90994 PIPE - PIPING  !!SI C-w C7.40 214 lCLASS 2 PORTION OF THE SH NU VT 091394

4-LOOP SYSTEM 'UTDOWN COOLING SYS I ISI D-B l D2.1C 541 '

REACTOR BUILDING CC VT-2 072694 PIPE CLOSED CLG WTA SYS-PIPING ISI D-B D2.10 424 CONDENSATE TRANSFER SYS.- CH VT-2 100494 PIPE PIPING 'ISI D-B D2.10 225 CONTROL ROD DRIVE SYSTEM NC VT-2 070894 NC-3 PIPE - PIPING NC-3 l ISI D-B D2.10 532 EMERGENCY SERVICE SWE VT-2 081194 PIPE WATER SYSTEM-PIPING ISI D-B iD2.20 541-1019 GU?DE CC VT-3 '072194

$UPORT (CC-4-MB) I ISI D-B D2.20 541-1032 ROD HANGER CC VT-31072194 SUPORT l(CC-3-H4} ' I SI l D-B HD2.20 541-1033 l ROD HANGER CC VT-3 072194)

SUPORT l(CC-3-H5)  :

ISI l D-B D2.20 541-1039 IROD HANGER CC VT-3 '0721941 1 SUPORT f(CC-4-M13) 1151 i D-B D2.20 541-1040 LGUIDE CC 'VT-3l071394l SEE TABLE 2 SUPORT (CC-a-Hta) [ISI l D-B D2.20 P-11-001 CONDENSATE TRANSFER PUMP CH VT-31020294 l H-1 SUPORT 1-1 2 WELDED ON 1 SKID l151 l D-B D2.20 532-BP-Sw-2-H14(B-0059' SLIDE , SWE VT-31091594 i SUPORT (Sw-2-H34) lISI D-B D2.40 541-1018 VARIABLE SPRING MANGEP CC VT-3 072194 SUPORT .(CC-4-H7) ISI D-B D2.40 541-1020 VARIABLE SPRING SUPPORT CC VT-3 072594 SUPORT  :(CC-4-H10) ISI D-C D3.10 251 SPINT FUEL POOL COOLING NN VT-2 071294 NN-1 PIPE SYSTEM-PIPING NN-1 ISI D-C D3.10 251 SPENT FUEL POOL COOLING NN VT-2 092294 NN-2 PIPE SYSTEM-PIPING NN-2 -

ISI D-C D3.10 531 SERVICE WATER SYSTEM (SwS) { SW VT-2 072094 c Sw-1 PIPE - PIPING Sw-1 l ISI

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DaTE: 03/15/EG PAGE: 0015 .

1. OWNER: Jarsoy Centrol power & Light Comp 2ny. Cadison Avsnus &

Punch 00=1 Cord. Corristomn. New Jersey

2. PLANT: Dyster Creek Nuclear Generatin9 Station.

U.S. Route 9. Formed River. Ne= Jersey .

3. PLANT UNIT: NA 4 OWNER CERTIFICATION OF AUTHORIZATION (if recuired): None
5. COMMERCIAL SERVICE DATE: 12/23/69
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor vessel 14895 OUTAGE 15R TABLE 1 I I IDENTIFICATION I l l l 1 Exam l ASME l ASVE ITAG NUMBEP l NDE DATE/ FROM DIAM./l CAT l ITEM NOISUFFIX CODE i DESCRIPTION USYSTI METH REASON TO DIAM. l REMARKS

__----------_------_------_---_-_--__--.-- ...------_-_--------_-----------_--__ __ -------------- __ =-

D-C lD3.20 lH-10-001C UAUG SPENT FUEL POOL Hx WE NN eVT-3l080294 i lH-1 SUPORT LLDED SUPORT (NN02-C) lISI D-C D3.20 lH-18-001C 'AUG SPENT FUEL POOL H) NN ;VT-31080294

~H-2 SUPORT l SUPPORT (NNO2-C) ISI F-A F1.10  : 411 -B P-MS-R 1 -00 2 2 MECHANICAL $NUBBER MS VT-3 093094 SUPORT (MS-1-51) PSI F-A F1.10 411-BP-MS-R2-0024 WECHANICAL SNUBBER N-t-5 MS (VT-3 :093094 PSI

~

SUPORT (MS-1-53)

F-A F1.10 411-BP-MS-R34-0003 "$CHANICAL SNUBBER N-1-6 MS :vT-3 '100394

$UPORT (MS-1-59) PSI F-A F1.10 411-BP-MS-P4A-0006 MECHANICAL SNUBBER MS VT-3 093094

$UPORT '(MS-1-511) ,

PSI F-A F1.10 L411-BP-MS-R4-0026 ' MECHANICAL SNUBBER MS IVT-3 092394 SUPORT  !(MS-1-54) '

HPSI F-A F1.10 411-9P-M5-R5-0027 MECHANICAL SNUBBER MS '

VT-3 092894 SUPORT (MS-1-55) PSI F-A F1.10 411-B -x-24-SS-1-0009 MECHANICAL SNUBBER S-1-1 MS VT-3 091994 A SUPORT (MS-1-513) PSI F-A F1.10 411-BP-x-2A-SS-1-0009 . MECHANICAL SNUBBER S-1-2 MS ' VT-3 093094 B SUPORT (MS-1-514) PSI F-A F1.10 411-BP-x-28-SS-1-0029 . MECHANICAL SNUBBER N-1-1 MS VT-3 100394 A SUPORT (MS-1-56) PSI F-A F1.10 (225-BP-NC-4-R5-0013 RESTRAINT NC oVT-3 091994 SEE TABLE 2 l SUPORT (NC-4-H12) ISI F-A IF1.10 l215-BD-N-9-SS-1-0004  ! MECHANICAL SNUBBER ND VT-31091994 I fB SUPORT l(ND-1-52) PSI F-A F1.10 211-BP-NE-5-H1-0057 l NE-5-10" VARIABLE SPRING NE VT-3 091794 SEE TABLE 2 SUPORT PIPE MANGER (NE-5-H1) ISI F-A -

F1.10 211-BP-x-38-SS-1-0039 NE-5-10* MECHANICAL PIPE NE VT-3 092794 A SUPORT SNUBBER (NE-5-53) PSI F-A F1.10 213-BP-NP-2-RBB-0005 WHIP RESTRAINT NP VT-3 091794 SUPORT (NP-2-H2) ISI F-A -

F1.10 213-BR-NP-1-R5-0014 U-BOLT NP VT-3 080294 SUPORT . (NP-2-H10) ISI F-A 'F1.10 214-BP-NU-1-M1-0001 { VARIABLE SPRING SUPPORT NU VT-3 092094 SEE TABLE 2 SUPORT (NU-1-H1) ISI E-A 'F1.10 214-BP-NU-1-H3-0039 VARIABLE SPRING SUPPORT NU VT-3 092094 SUPORT (NU-1-H3) ISI F-A F1.10 214-BP-NU-1-H8-0016 SLIDE NU VT-3 020294 SUPORT (NU-1-H11) ISI F-A F1.10 .

212-BP-461-R2-0051 -

MECHANICAL $NUBBER NZ VT-3 092894 SUPORT (NZ-3-SB) PSI F-A lF1.10 212-BP-461-R3-0002 MECHANICAL SNUBBER NZ VT-3 092294 l SUPORT l(NZ-3-S3) PSI

. . . ~ . ~ ..- .. . - .-,- - - .

1 s

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTION DATE: 03/15/05 PAGE* 0016 . -

1 OWNER: Jersey Central Power & Light Company. Dodison Avenue & ,

j Punch 80=1 Road. Morristown. New Jersey

2. PLANT: Oystee Creek Nuclear Generatin9 Station.

U.S. Route 9. Forked River. Nem' Jersey -

3. PLANT UNIT: NA
  • 4 DwMER CERTIFICATION OF AUTHORI2ATION (if reautred): None
5. COMMERCIAL SERVICE DATE: 12/23/69 r
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vessel.14895 OUTAGE ISR TABLE 1

....... =....................-= .--- . =- .__ --- - ................- == ......- -- -- =

-= ....- __.....

IDENTIFICATION I l l l l l EXAW ASwE ASWE TAG NUMBER l $NDE i DATE/. FROM DIAW./ 4 CAT ITEM NO SUFFIX CODE i DESCRIPTION SYSTlmETHlREASON TO DIAW. REMARKS hA- F 10 4 2 BD RF R H 0011 VARIABLE SDRING HANGER R VT 3 09 5941 SEE TABLE 2 [

SUPORT f(R*-2-Hit) 'ISI 1.

F-A. F1.10 422-BD-RF-RS-0025 MECHANICAL SNUBBER RF VT-3 092894 .

li SUPORT (RF-2-55) PSI l F-A lF1.10 422-8P-X-4A-SS-1-0027 lWECHANICAL SNUBBER RF VT-3 .091994 8 l(RF-2-56A)

I SUPORT -

PSI F-A- F1.20 411-80-729-739(1)-0010 ANCHOR MS (VT-3 101994 A .

SUPORT (MS-1-H8C) l PSI i F-A F1.20 211-80-NE-1-H6-0063  ! VARIABLE SDRING HANGER NE IVT-3 082594 t SUPORT l(NE-1-H1) 'ISI F-A F1.20 211-BP-634-R9-0028 NE-2-10" HYDRAULIC PIPE NE- VT-3 051794 SUPORT SNUBBER (NE-2-520)- ISI f F-A F1.20 241-BD-NO-Z-H18-0022 ROD MANGER NG VT-3 092194 SUPORT (NQ-2-H59) l ISI F-A F1.20 241-8P-NO-2-H20-0018 ROD HANGER { NQ VT-3 1109948 [

(NQ-2-H75)

SUPORT PSI

~

F-A F1.20 241-BD-NQ-2-H51-0090 VARIABLE SPRING HANGER NQ VT-3 072194 SUPORT (NQ-2-H8) ISI 8-A F1.20 241-BD-433-R2-0057 HYDRAULIC SMUSBER NQ VT-3 !O60893 THIS PSI IS PER J.O.34856 .i j $UASRT. (NQ-2-S7) 1151 P-A F1.20 241-80-487-RS-0032 HYDRAULIC SNUBBER 23/3 VT-3 020794

' NQ SUPDRT l(N0-2-514) PSI F-A F1.20 241-8D-NQZ-T-H1(E-0099l SLIDE NQZ VT-3 051294 SUPORT f(NQZ-1-H5)  :

ISI F-A F1.20 .

241-SP-NQZ-1-RS-0098 l HYDRAULIC SNU58ER - 19/15 NQZ VT-3l 051294 I A SUPORT l(NQZ-1-53) ISI-F-A IF1.20 '241-BD-NQZ-1-RS-0098 lHVDRAULIC $ NUB 8ER - 19/14' NQZ VT-3"051294  ;

9 SupORT l(N02-1-54) ' ' IISI F-A F1.20 1212-8D-NZ-2-H43-0080 VARIABLE SPRING MANGER' NZ VT-3 'D82294 .SEE TABLE 2 SUPORT. (NZ-2-H36)- ISI F-A F1.20 212-BP-411-R10-0078 HYDRAULIC SNUB 8ER' NZ 'VT-3 072994 ,

I- SUPORT l (NZ-2-512) .

ISI- ,

' F-A IF1.20 "212-BD-411-R11-0065 HYDRAULIC SNUB 8ER l NZ VT-3 020294 (NZ-2-515) IISI l SUPORT l F-A lP1.20 422-1004 NEED DETAILED DRAW 1NG RF VT-3 091494 l

  • I SUPORT (RF-2-H16) ISI F-A (F1.20 422-1007 NEED DETAILED DRAW!NG RF lVT-3 091494 SUPORT 'l(RF-2-H18) ISI F-A F1.20 422-1009 VARIABLE- RF VT-3 091494 SUPORT (RF-2-H22) ISI F-A F 1.30 ' 531-1018 ROD HANGER l SW IVT-3 110194 SUPORT . j PSI >

F-A F1.30 531-1019 -

ROD HANGER liSW VT-3 110194 SEE TABLE 2 L i SUPORT 1 i PSI 1 L

_______-.-_._____-m_.m__m.__.- _.__. _ _ _

,---.__m._.-----..www..' - - -..,-...-.m.__-m --_..-.._m-. . , , - ._mm--....~..m-&n-_ _ ._m - .___ .

NIS-1 OWNERS DATA REP 02T FOR INSERVICE INSPECTION DATE: 03/15/95 PAGEt 0017 .

i 1. OTNER: Jersey Csntral Power & Light Compsny. Madison Avenue &

Punch Cow 1-Rocd. Corristown. N3w Jersey

2. PLANT: Oyster Creek Nuclear Generating Station. ~

U.S. Route 9. Forked River. New Jersey .

3. PLANT UNITt NA 4 OWNER CERTIFICATION OF AUTHORIZATION (if required): None
5. COMMERCIAL SERVICE DATE: 12/23/69 .i
6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vesse! 14895 OUTAGE 15R TABLE 1

__________ __________.---_________- --_=.... ________________.-_______________---- =__ =-- _ _________----- -- _____

l IDENTIFICATION '

l EXAM ASME l ASME TAG NUMBER NDE DATE/ FROM DIAM./

CAT l ITEM NOI SUFFIN CODE -DESCRIPTION SYSTlMETHIREASONI TO DIAM. REMARKS


__- ....------. -__.....------____----__--___. =_

F-A 'F1.30 531-1034 14" SW PIPE ROD MANGER SW VT-3 110294 .

l SUPORT . PSI F-A 'F1.30 531-1035 14" SW DIPE ROD HANGER SW VT-3 092994 SUPORT PSI F-A F1.30 532-GU-ISH-10-0072 ROD MANGER I SWE VT-3 110194 SUPORT (SW-2-H1-8) PSI F-A F1.40 P-11-001 CONDENSATE TRANSFER PUMP CH- VT-3 020294 H-1 SUPORT 1-1 2 WELDED ON 1 SKID ISI F-A F1.40 411-5P-MSH-4-0030 VARIABLE SPRING SUPPORT MS VT-3 091794 SEE. TABLE 2 SUPORT (MS-1-H3C)  : ISI F-A F1.40 211-0123' VARIABLE SPRING MANGER ON NE. VT-3 051794 SUPORT V-14-0033 ISI F-A F1.40 211-0125 NE-2-10" VARIABLE SPRING NE VT-3: 091294 SEE TABLE.2:

  • I SUPORT HANGER ON V-14-0035 ISI F-A P1.40 223-GR-H4(C)-0026 CONSTANT NG VT-3 091594 SEE TABLE 2 SUPORT (NG-C-H3) ISI F-A F1.40 223-GR-H6(C)-0029 VARIABLE NG VT-3 091594 i SUPORT (NG-C-H12) . I SI F-A F1.40 223-GR-SS-1(C)-0031 MECHANICAL SNUSSER NG VT-3 091494 A SUPORT  :

(NG-C-53) PSI F-A F1.40 223-GR-SS-2(A)-0010 MECHANICAL SNUSBER NG VT-3 091994 0- SUPORT (NG-A-56) PSI' F-A (F1.40 223-GP-SS-2(E)-0054 . MECHANICAL' SNUBBER NG VT-3 091794 l lB SUPORT , (NG-E-56) PSI F-A IF1.40 lH-18-001C lAUG SPENT FUEL POOL MX WE NN l VT-3 080294 i H-1 SUPORT- LDED SUPORT (NNO2-C) l ISI F-A lF1.40 H-18-001C AUG SPENT FUEL POOL HK ~ NN VT-3 080294 H-2 SUPORT ' SUPPORT (NNO2-C) ISI F-A F1.40 P-20-001B CORE SPRAY PUMP NZO1-B ;NZ VT-3 013194 SEE TABLE 2 H-1 SUPORT '2 WELDED 1 SUPPORT ON SKID ISI F-A F1.40 NR02  : RX VESSEL SUPPORT RX- VT-3 091794 SUPORT ISI

____ - _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ . _ _ _ _ - . - _.._._.........._.__.m.._.-_.,,_..---...._.__u_-.___._._, . . _ _ . . _ _ _ _ _ . - _ _

i ,

l I

< C321-95-2113 )

ATTACIIMENT II l

i 1

1 1

! NIS-2 FORMS 1 i l

\ l 1

i 4

1 1 i

i OYSTER CREEK l i NUCLEAR GENERATING STATION 1 1 i.

REFUELING OUTAGE 15R i

j 4

)

i n

1 1

d

I FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ,

As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light IN $kf N IO, }QQ (
  • Date Madison Avenue & Purft8MBowl Road Morristown, N.J. 07960 Addoes Sheet / of N
2. Plant _. Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 N'"

Forked River, N.J. 08731 Addreas Mopelt Oreenlastion P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp NONE
  • One Upper Pond Road "*"'"

Authorization No. NONE' Parnipoany. N.J. 07054 Empiretion Date NONE Address  ;

i

4. Identification of System Main Steam System S. (a) Applicable Construction Code B31. I 19 55 Edition, ACdenda- Code Case -

(b) Applicable Edition of Section XI Utilized for Repairs or Replacement 19 P6 i

6. Identdication of Components Repaired or Replaced and Replacement Components l

r ASME Code National Repaired, Stamped Nome of Name of Manufacturer Board Other Year. Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Renlacement or No) c:PP ATTACHE )

N N

~ l l

l

7. Description of Work Renlacement of snubbers
8. Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O N/A Other O Pressure psi Tesi Temp. r NOTE:

Supple mental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 m., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l  !

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l

i e

. -. .. . - - + ~ . ~ _ . . _~ . . . . . . - . - , _ . - . . - . . - . - -

I f

i g

b i

t I

l i

FORM NIS-2 (Back)  !

I I

9. Remarks Applicable Manufacturer's Data Meoorte to be attached t

l l

l CERTIF6CATE OF COMPLIANCE 1

i If j

We certify that the statements made in the report are correct and this fanl en=n* conforms to the rules of the j ASME Code, Section X1.

t t

Type Code Symbol Stamp MnNP N/A N/A  !

Certificate of Authorization Ne, Empiration Date t Signed !l #dnee, Sb7//b/ Titl6 J2k M9 / A Date 3/ 3 $~

  • Owner er Owner's g {
  1. I t

CERTIFICATE OF INSERVICE INSPECTION . l 1, the undersigned, holding a valid commission issued by the Nationel Board of Boiler and Pressure Vessel inspectors and the Siete .  !

or Provence of New 3ersey and employed by H.F.B.I.&I. Company og l Hartford, Ct. have inspected the components described  !

in this Owner's Report during the period February 17, 1993 December 15, 1994 and state thet -

to l to the best of my knowledge and belief, the Owner has performed eneminations and taken corrective measures described in this Owner's Report in accordence with the requirements of the ASME Code,Section XI. j By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the l examinations and corrective s.wasures described in ' Owner's Report. Furthermore, neither the in_spector nor his employer l shall be lieble in any manner for any personal injury . property damage or a loss of any kind arising from or connected with this j inspection. {

Commissions NB5478 (I) (N) NJ442

~et .o. .. .t.t. ,,..inc.. en. . n.or n.s y e mn..c . s fur. )

Date

~

19 b i (12/82) .

i l

I I

I 1

l l

NIS-2 l

l l

6. Identification of components Repaired or Replaced and Replacement components Attachment 1

NAME OF REPAIRED, ASME NAME OF COMPONENT REPLACED, CODE MANUF. OR REPLANCEMENT STAMPED l (YES OR NO) l 411-BP-MS-R1-0022 PACIFIC REPLACED NO SNUBBER SCIENTIFIC l 411-BP-MS-R2-0024 PACIFIC REPLACED NO l SNUBBER SCIENTIFIC 411-BP-MS-R3A-0003 PACIFIC REPLACED NO SNUBBER SCIENTIFIC 411-BP-MS-R4-0026 PACIFIC REPLACED NO SNUBBER SCIENTIFIC 411-BP-MS-R4A-0006 PACIFIC REPLACED NO SNUBBER SCIENTIFIC 411-BP-MS-R5-0027 PACIFIC REPLACED NO SNUBBER SCIENTIFIC l 411-BP-I-2A-SS-1-0009 A PACIFIC REPLACED NO SNUBBER SCIENTIFIC i 411-BP-I-2A-SS-1-0009 B PACIFIC REPLACED NO SNUBBER SCIENTIFIC 411-BP-I-2B-SS-1-0029 A PACIFIC REPLACED NO SNUBBER SCIENTIFIC 411-BP-729-739(1)-0010A PACIFIC REPLACED NO SNUBBER SCIENTIFIC Page 3-of-3

I I

j i

FORM NIS-2 OWNER'S REPORT FOR REPAIR $ OR REPLACEMENTS '

As Required by the Provisions of the ASME Code Section XI fi

}

1. Owner Jersey Central Power & Light @ggy g Madison Avenue & Purft!MBowl Road '

fQQf .

[

I Morristown, N.J. 07960 Accrees Swee, / og 2 f

2. Plant Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 "*"* '

Forked River , N.J. 08731 I Adereas nepair oreentration P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp NONE j One Upper Pond Road "*"*

Authortretion No. NONE j Parnippany. N.J. 07054 Expiretion Date NONE  !

Amorees 4 Identification of System Rx Water Cleanup ..

5. (e) Applicable Construction Code B31.1 1,55 Edition, i Addende Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 190 1
6. Identification of Components Repaired or Replaced and Replacement Components

%SME Code National Repaired. Stamped Name of Name of Manufacturer Component Board Other Year Re A.sd, (Yes i Manufacturer Serial No. No. Identification Built or Re6ft/9 ment orNol  !

2 V-16-133 VALAN NA NA NA NA Replace N x

m w

N l 7. Description of Work The bolting was replaced on valve V-16-133

8. Tests Conducted: Hydrostatic Pneumatic OtherO Pressure 1050 Nominal psi Operating Test Temp. _225 Pressure C.p l NOTE:  !

' Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) site is 84 in. x 11 in., (2) Inforrne.

tion in items 1 through 6 on this report is included on each sheet, and (3) escr. sheet is numbered and the number of sheets is j

recorded et the top of this form.

l (12/82)

This Form (E00030) may be obtained from the Order Dept., ASM'!,345 E. 47th St., New York, N.Y.10017

. .ean.e ' *

-* ---g  % -y yr-,- -W w y y . + - - 3

t I

I i

i i

, FORM NIS 2 (Back) i f 9. Remarks l Applicable Manufacturer's Date Reports to be attached i

l CERTIFICATE OF COMPLIANCE ,

We certify that the statements made in the report are correct and this EPPI ar'om"*onforms to the rules of the i

ASME Code, Section Xl.

l i

l Type Coce Symbol Stamp MME .

' 1 l Certificate of Authorization No. M Expiration Date 'n l s;gned 4 1 N Date 19 l owner or own essenes, Title #

l CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New <Tercey and employed by H.S.B.I.&I. Company og Hartford, Ct. have inspected the components described in this Owner's Report during the period February 17, 1993 to December 15, 1994 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code Section XI. .

By signing this certificate neither the inspector nor his employer makes any warranty, empressed or emptied, concerning the -

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage of a loss of any kind arising from or connected with this inspection.

l Commissions NB5478 (I) (N) NJ442 V -'a n'op4ctoEs Signat/re Nationet Boers, State, Province, and E ndorsements Date 9 19 N I ,

I l

(12/821 i

l i

I

4 l

l . .

I l

I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS  !

As Required by the Provisions of the ASME Code Section XI

{

1. Owner Jersey Central Power & Light , @gyg gp .

{

Madison Avenue & Purft'f! Bowl Road  !

Morristown, N.J. 07960 Amorose Sheet / of N

2. Plant - Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 "***

l Forked River, N.J. 08731 Amoreas Mapelt Oreenization P.O. No.,Joo No., etc. I

3. Work Performed by GPU Nuc1 ear Corporation Type Code symbol stamp NONE Nome l One Upper Pond Road Authorization No. NONE Pa re:i neanv . N.J. 07054 l' Expiretion Date - NONE Accrees
4. Identification of System Isolation Condenser System i
5. (a) Applicable Construction Code B31.I 19 55 Edition, Addends- Code Case I (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 19
6. Identdication of Components Repaired or Replaced and Replacement Components  !

ASME {

Co*Je National Repaired, Stamped Name of Name of Manufacturer Board 4

Other Year Replaced. (Yes Component Manufacturer Serial No. No. or Replacement or No) l Identification Built  ;

V-14-0032 Anchor Darling NA" NA NA Replacement NO i

N

~

N

7. Description of work A new retainer ring was inutalled to valve V-14-0032
8. Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure b Other O Pressure 1050 _ psi Test Temp._225 .p NOTE:

Supplemental sheets in form of lists, sketches, or drowings may be used, provided til size is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) mey be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i

( _ -,

l .l l  !

\ -

l l

'I 1

I i

~

l FORM NIS-2 (Back) s [

9. Romerks Applicobie Manufacturer's Date Reports to be esteched i

l I

l i

A, l

CERTIFICATE OF COMPLIANCE i We certify that the statements made in the report are correct and thipelacement conforms to the rules of the  !

ASME Code, Section Xl.

I

' Type Code Symbol Stamp NONE j Certificate of uthorization No. NONE Expiration Date WP l

Signed 5 bf ^

Date ~ 19 ownerpr owner nee, THis g l

CERTIFICATE OF INSERVICE INSPECTION i I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New Jersev =nd employed by H.S.B.I.&I. Company ,,

Hartford, Ct. have inspected the components described I I in this Owner's Report during the period February 17,'1993 to December 15, 1994- . and stone that l to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this

! Owner's Report in accordance with the requirements of the ASME Code,Section XI. j Sy signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the j examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer sheit be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ,

.I Commissions' NB5478 (I) (N) NJ442 {

e u.mors ...ne.u,.y ~.t.r,. . ,e, ... . ,,ome. .n. . n.or.e-en,e ,

1 cate MAR' 9 19 96  !

l 02/82) i i

y ._p__, ,_,,w__ . , , , ., . . , _ , _

FORM Nis 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light ygppg.g gy .

Madison Avenue & Puzft.9! Bowl Road '

~

Morristown, N.J. 07960 Mem Sheet

/ of E l

2. Plant . Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 "*"*

Forked River, N.J. {

08731 Adesse j Receir oreenization P.o. No., Job No., etc.

{

3. Work Performed by GPU Nuclear Corporation Typo code symbol stamp NONE '

One Upper Pond Road " "

  • Authoritmion No. NONE' Parsd peanv. N.J. 07054 Empiration Dme NONE Asesos
4. Identifiestion of System Core Spray System
5. (e) Applicable Construction Code B3121 3g 55 Edition. Addende_ code case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 R A
6. Identification of Components Repaired or Replaced and Replacement Components ASME i code j National Repaired, Stamped i Name of Name of Manufacturer Board - Other Year Replaced, (Yes Component Manufacturer ,

Serial No. No. Identification Built or Replacement or No) >

V-20-0041

~

NA fA N / A' MfA f6 A NfA.

N.

N w

w w

~

N x

7. Oescription of work *N W"
8. Tests Conducted:

Hydrostatic 0 Paeumatic O Nominal Operatingrgesure @

OtherO Pressure 1050 psi Test Temp. *

.F NOTE: Supplemental sheets in form of lists, sketches, or drowings mey be'used, provided (1) size is 84 in. x 11 in (2) Informa-tion in items 1 through 6 on this report is included on sech sheet, and (3) sech sheet is numbered and the number of sheets is i recorded at the top of this form.

l (12/82) $

This Form (E000301 may be obtained from the Order Dept., ASME,345 E 47th St., New York, N.Y.10017 '

  • -=emew ,,

--=-r~ ' ' ' * ' '

p i

l ,

I i

l l

i

! t FORM NIS 2 (Back) l  ;

l 9. Remarks Applicable Manufacturer's Data Reports to be attacheo ,

i I

i l

i CERTIFICATE OF COMPLlANCE

(

l We certify that the statements made in the report are correct and this Renai r conforms to the rules of the ASME Code,Section XI.

l l

Type Code Symbol Stamp NONE NA Expiration Date NA f Certificate of Authorization No.

Signed / 'l A N NDate 19 Owner of Owner's Des n e. Tatio fj U

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New Jeney and employed by H.S.B.I.&I. Company og liartf ord, Ct. heve inspected the components described in this Owner's Report during the period February 17, 1993 to December 15, 1994 _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, f> Commissions NB5478 (I) (N) NJ442 c,emos.en.go ~.t on.. .o.ro. ....e. .,0..n.e. .no . noo,som.nts Date SAS 19 N (12/82) l

l FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code section XI

1. Owner Jersey Central Power & Light ggg g, g g.-

Madison Avenue & Purft'MBowl Road '~

Morristown, N.J. 07960 Aderses Sheet / of 7

2. Plant. Ovster Creek NGS unit Oyster Creek i 4

U.S. Hwy. 9 "***

Forked River N.J. 08731 Addreen l Rooelr Creenirstion P.O. No., Job No., etc. j

3. Work Performed by GPU Nuclear Corporation Type Code symbol Stamp NONE One Upper Pond Road Name Authorirstion No. NONE Parnippanv. N.J. 07054 Expiretion Date NONE Address
4. Identification of System Clean up Demineralizer System' S. (a) Applicable Construction Code B31.1 19_55 _ Edition, Addende. Code Case (b) Appricable Edition of Section XI Utilized for Repairs or Replacements 19 A6
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stemped Name of Name of Manufacturer Board Other Year Replaced, (Yes j Component Manufacturer Serial No. No. Identification Built or Replacement or No)

.i l

Pacific '

215-0004B Scientific NA NA ' NA NA Replacement NO 1

N 1

i N

N w

l N. ,

l 7. Description of Work The original snubber was replaced with a new' snubber. i i

8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure O h*' Pm*8um psi Test Temp. - *p NA ,

i NOTE: Supplemental sheets in form of lists, sketches or drowings may be used, provided (Il sire is 8% in, a 11 in., (2) informe.

tion in items 1 through 6 on this report is included on coch sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form, l j

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 I

I  !

  • ' * ~ = m

, - 4 m

p I

i I

-' FORM NIS-2 (Back) .:

_ f- -!

1

' ' ^ '

9. Remarks Aoptic.bl. Manufacturer's D.te Meports to be attach.d {

t i

e 5 b r

i CERTIFICATE OF COMPLIANCE ,

We certify that the statements made in the report are correct and this12nn1 =A conforms to the rules of the

'***I'**'***'"*"1 ASME Code, Section X1, i

Type Code Symbol Stamp NONE Certificate of Authoritation No. NA Expiration Date NA l 4 -

Date  ! 19 Signed- 0.u, .. o.n.<sg. fen.e,1,t . g i

i CERTIFICATE OF INSERVICE INSPECTION ,

l, the undersigned, holding a valid commission issued by the National Board of Boiler end Pressure Vessel inspectors and the State  ;

! or Province of _ New Jersey and employed by H.S.B.I.&I. Company og j Hartford,-Ct. have inspected the components described  ;

in this Owner's Report during the period February 17, 1993 to December 15, 1994 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the reouirements of the ASME Code,Section XI. }

l By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the 3 examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. l i

Commissions NB5478 (I) (N) NJ442 rnso.ctors ..en.p. ~ .t.o n .o.,.. .t.t.. ,..mc.. .nu ne.-s  :

Date bfM. l 1e W_

i l

(12/821  !

r I

I i

l-l i

l

~,, .

I

. . i FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI f i

, , g n,, Jersey Central Power & Light 9,, gyg g, g g-Madison Avenue & PurfteMBowl Road '

Morristown, N.J. 07960 Adoroes Sheet / of 2 '

2. Plant Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 N*'"*

I Forked River, N.J. 08731 Amareas moosir oreenitetton P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporation Type Code symbol Stamp NONE One Upper Pond Road N'**

Authoritetion No. NONE Parsicoany, N.J. 07054 Empiretion Date NOME Address

4. Identification of System Core Spray System I
5. (e) Applicable Construction Code B31.1 gg 55 Edition; Addende- Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 R6 I
6. Identdication of Components Repaired or Replaced and Replacement Components  !

I

, f l

l ASME Code  !

National Repaired, Stemped Nome of Name of Manufacturer Board Other Year Replaced, (Yes Component Manu facturer Serial No. No. Identification Built or Replacement or No)

Pacific '

i f 212-0051 Scientific NA NA ' NA NA Replacement No  !

217-0002 NA NA E E D## #

i i

N N

N w '

N

7. Description of work New snubbers that replaced the original

! 8. Tests Conducted: Hydrostatic Pneumeric O Nominal Operating Pressure Other Pressure psi Test Temp.

'F NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) site is 8% in. m 11 in., (2) inforrne.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) i This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 '

l I

a-: ,

l 1

FORM NIS 2 (Back) l

9. Remarks h Aopticable Manufacturer's Data Reports to be attached i

I i

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and n?

thisD_e#M

'** ' ' * * ' * * *^-^a

?

Type Code Symbol Stamp NOMP i

Certificate of Authorization No. NA Expiration Date NA  ;

Signed A '

Date  !~ ,19 owner br owners ssnee, Title p ,

f CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State

or Province of New Jernev and employed by H.S.B.I.&I. Company og  ;

I Ilartford, Ct. have inspected the components described in this owner's Report during the period February 17, 1993 December 15, 1994 . and state that l to l I

to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this  ;

Owner's Report in accordance with the reauirements of the ASME Code,Section XI.

j By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the  ;

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer j shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

=

' Commissions NB5478 (I) (N) NJ442

,ov.n... .ne . n.o, r.o.ctors ..ex .tu,.f ~ .t.n., as.,.. .t.t.. mw.t.

l 1

care I4 h 19 (12/82) ,>

i

l I ,

t FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS  :

As Required by the Provisions of the ASME Code Section XI '

1. Owner Jersey Central Power & Light gggg fyy '

Madison Avenue & PurfLT! Bowl Road " '

Morristown, N.J. 07960 Address Sheet / of 2  !

l

2. Plant Ovster Creek NGS Unit Oyster Creek ,
U.S. Hwy. 9 "***

l Forked River, N.J. 08731 -

Address Raoelt Orsenization P.0, No., Job No., etc. h

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stemo NONE

! One Upper Pond Road "***

Authorization No. NONE.

parsippany, N.J. 07054 Empiretion Date NONE Address ,

4. Identification of System Service Water System i _
5. (a) Applicable Construction Code B31.1 jg 55 Edition, Addende; Code Cese (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 P6
6. Identification of Components Repaired or Replaced and Replacement Components

?

ASME i Code  :

National Repaired, Stamped Name of Name of Manufacturer Board Other Year Reptoced, (Yes Component Manufacturer Serial No. No, identification Built or Replacement or No) ,

531-1035 GPUN - - -

1994 Replacemerit No 531-1034 GPUN - - -

1994 Replacemerit No '

531-1019 GPUN - - -

1994 Replacement NO '

531-1018 GPUN - - -

1994 Replacement No i

l l

7, Description of Work Replacement of pipe support

8. Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nomir.el Operating Pressure O OtherO Pressure _psi Test Temp. 'F NOTE: '

Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) slie is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12,82)

This Form (E00030) may be obtained frem the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

._,w

4 8 FORM NIS 2 (Back) '

9. Remarks Applicable Manufacturer's Date Mooorts to tre etteched

, + .

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the .

ASME Coos, Section Xl. 1'''''''***"'*"'

Type Code Symbol Stamp NONE Certificate of Authoritation No. N/A Expiration Date N/A Signed ^*4 E Date 19

" Cbnef or owner sense, fitte (/

CERTIFICATE OF INSERVICE INSPECTION .

I, the undersigned, holdin0 a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New Jersey and employed by H.S.B.I.&I. Company og Hartford, Ct.- have inspected the components described in this Owner's Report during the period February 17, 1993 to December 15, 1994 _ and stoie that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this lngpection.

' Commissions NB5478 (I) (N) NJ442

.nso

, s ..enaut. f ~ .t.o r,e, .oe,.. .t.,s. ,o..n... en. . n..,s ,.n s Date bd8 19 I (12/B2)

i FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light ggg g .- .

Madison Avenue & Purft*mSowl Road Morristown, N.J. 07960 8 j Adorous Sheet / of '

2. Plant Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 Navne Forked River, N.J. 08731 l Adoroes piepair oreenization P.O. No., Job No.. etc.
3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp NONE j One Upper Pond Road "*'"*

Authorization No. NONE Pa r c:1ppany. N.J. 07054 Empiretion Date NONE Adorsee

4. Identification of System Feedwater System
5. (a) Applicable Construction Code B31.1 55 3, Edition, Addende_- Code Case Ib) Applicable Edition of Section XI Utilized for Repairs or Replacements Ig 86
6. Identification of Components Repaired or Replaced and Replacement Components -

ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Replaced, Other Year (Yes Component Manufacturer Serial No. No, Identification Built or Replacement or No) 422-0025 Pacific Scientific - - - - -

NO 422-0027 Pacific Scientific - - - -

NO N

w N

N w

7. Description of Work Snubber replacement
8. Tests Conducted: Hydrostatic 0 Pneumetic Nominal Operating Pressure OtherO Pressure psi Test Temp. - 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is BM in. x 11 in (2) Informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/B2)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 e

ew . ee

__ _. - _ . . _ _ __ . _ _ _ . _ . ~ ~ _ __~ _ . . . . - ._. _ _. _ _

i

. FORM NIS 2 (Back) q i

~

9. Remarks Applicable Menufacturer's Date Reports to be attached ll

.i i

~l l

(

i CERTIFICATE OF COMPLIANCE -

We certify that the statements made in the report are correct and this Renlacamont conforms to the rules of the .!

ASME Code,Section XI, ']

l l

Type Code Symbol stamp NONE f Certificate of Authoritation No, N/A Expiration Date N/A l

~

Signed e Date 19 O(enerlor owner'sgones, Titief G

i > 3 CERTIFICATE OF INSERVICE INSPECTION i I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State f or Province ofdleW JerEey and employed by H.S.B.I.&I. Company og j

!- Hartford, Ct. have inspected the components described l in this Owner's Report during the period February 17, 1993 December 15,~1994 . and state that to f to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this  !

Owner's Report in accordance with the requirements of the ASME Code,Section XI, i By signing this certificate neither the inspector nor his employer rnakes any warranty, expressed or implied, concerning the j examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer I j shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this  !

inspection, d Commissions NB5478 (I) (N) NJ442 l ipid6ctor's Sienstur Netsonal Board. State, Province, and Endorsements Date NN 19 W O 2/82)

-M d

. --,r. - - ~ , , . - , , _ . , ,

,l

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light gg g g._ ,

Madison Avenue & Purft8m5 owl Road Morristown, N.J. 07960 Sheet / of M Address '

2. Plant Ovster Creek NGS Unit Oyster Creek '

U.S. Hwy. 9 "*'"*

Forked River, N.J. 08731  !

Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp NONE  !

One Upper Pond Road "*'"*

Authorization No. NONE Parsipoanv. N.J. 07054 Expiretion Date NONE  ;

Address 4 Identification of Svetem . Emergency Service Water System t

5. (a) Applicable Construction Code B31.1 39 55 Edition, Addende Code Case ib) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86 i
6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes f Component Manufacturer Seriel No. No. Identification Built or Replacement or No) s 1

532-0072 GPUN NA NA NA 1994 Modifica tionNf N~  % l N

N w

N x

7. Description of Work. Pipe support was modified j
8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure O i

N/A Other O Pressure psl Test Temp. - 'F l

NOTE: l Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. m 11 in., (2) Informe- '

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form.

(12/82)

This Form (E000301 rney be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l

I e

I

+=ee.

-.w--. .-.o y t- v

i i

.i i

! t t

l FORM NIS-2 (Back) l l

I i

9. Remarks >

l Applicable Manufacturer's Date Reports to be etteched f I f

[

r l

i f

k i

i CERTIFICATE OF COMPLIANCE [

We certify that the statements made in the report are Correct and this 18^Aif f etiOpRpforms to the rules of the }

'*****'*****"*- [

ASME Code Section XI, i

i Type Code Symbol Stamp NnNP >

Certificate of Authorization No. M/A Expiration Date N/A NE Signe ' 'f)wnair or owner D sones, Title E US/ -

Dete  ! ~ 19

()

v  :

I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State i or Province of New Jereey end omployed by H.S.B.I.&I. Company og i Hartford, Ct. have inspected the components described [

in this Owner's Report during the period February 17, 1993 to December 15, 1994 . and state that [

to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this

[

Owner's Report in accordance with the roouirements of the ASME Code,Section XI, l

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the j examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer j shall be lieble in any menner for any personal injury or property damage or a foss of any kind arising from or connected with this {

inspection. '

{

/ Commissions NB5478 (I) (N) NJ442 InsoMo'r'fsig'risture National Board, State, Province, and Endorsements i

oa,e A.9 , , <  !

(12/82)

{

i j

i l

l I

.1

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI  ;

i

1. Owner Jersey Central Power & Light Madison Avenue & PudtMBowl Road '

ygg y gy ,

Morristown, N.J. 07960 /

Aooroes shes ,, 2 i

2. Piant___.Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 N***

Forked River, N.J. 08731 Adorous Mepear orpenization P.o. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp NONE -

One Upper Pond Road N'**

Authorization No. NONE '

Parsippany. N.J. 07054 Empiretion Date NONE Address

4. identification of System Reactor Recirculation System '
5. (a) Applicable Construction Code B31.1 ig 55 Edition, Addenda, Code Case l tb) Applicable Edition of Section XI Utilized for Repairs or % placements 19 86 '
6. Identification of Components Repaired or Replaced and Replacement Components ASME  ;

Code National Repaired, Stamped '

Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or No) -

-n 223-0054B b$$ $fic NA NA

  • NA NA. Replacemer t NO i

223-0010B NA NA NA NA i

223-0031A NA NA NA NA N

' i N ~  !

W ~_ l

7. Description of work New snubbers were installed and replaced the original supports j
8. Tests Conducted:

Hydrostatic 0 eneumatic O Nominai Operetine eressure O Other Pressure . _psi Test Temp. 'F NOTE:

Supplemental sheets in form of lists, sketches, or drewings rney be used, provided (1) size is 84 in. x 11 in (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) mey be obtained from the Order Dept., ASME,345 E. 47th St.. New York. N.Y.10017 i

l I

ame.we **

_y_t

l t l l I l

  • l l

l 1

i FORM NIS 2 (Back) l

?

9. Remarks  !

Applicable Manufacturer's Data Rooorts to be attached i

y I

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thisReplacement conforms to the rules of the  ;

ASME Code, Section Xt. '"'*****"'

Type Code Symbol Stamp NONE f I

Certificate of Authorization No. NA Expiration Date NA j Signed <b N 3 N Date 19 ownsfor owner syenee, T6 tie (/

CERTIFICATE OF INSERVICE INSPECTION l 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Provmes of New Jersev and employed by H.S.B.I.&I. Company og i Hartford, Ct. have inspected the components described ,

in this Owner's Report during the period February 17, 1993 to December 15, 1994 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI, .

. t By signing this certificate neither the !nspector nor his employer rnakes any warranty, expressed or implied, concerning the l examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this i inspection, f

. so I

,.rs ...4,ar.

II' Commissions NB5478 (I) (N) NJ442

~.t.on.. .o.,o. ...... ,,o..n.e. .nu no.,eem.n.s 7  ;

Date MM 19 b l

f (12/82) t I

I h

i k

{

(' . .

l l

i l

I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light yyy g g _.

Madison Avenue & Pudt*MBowl Road Morristown, N.J. 07960 /

Addreas sh , og 2 l

2. Plant ___Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 "***

Forked River , N.J. 08731 t Addreen Pteosir Orsenisation P.O. No., Job No., etc. .

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp NONE '

One Upper Pond Road "*'"*

Authorization No. NONE pa r e:i npany . N.J. 07054 Empiration Dete NONE Address 4 Identification of System Containment Spray System t

5. (a) Applicable Construction Code B31.1 19 55 Edition: Addende. Code Case ,

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986 '

6. Identification of Components Repaired or Replaced and Replacement Components l ASME  :

Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes "

Component Manufacturer Seriet No. No. Identification Built or Replacement or No) i I

241-0032 haE0 Son NA NA

  • NA NA Replacemer t NO 2g-0018 GPUN NA NA NA NA Replacemer.t NO l

N ,

N w ^

N i N w  !

i

7. Description of worg 241-32 is a new support that replaces the original 241-18. New  !

bolting was installed.

8. Tests Conducted:

Hydrostatic 0 Pneumetic 0 Nominal Oper& ting Pressure O OtherO Pressure psl Test Temp. _' F l NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) Informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recoroed at the top of this form.

l l (12,82)

I This Form (E00030) mey be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l

i l . we *

  • J l

i

! i l l l

I d

FORM NIS 2 (Back) ~'

9. Remarks l Applicaole Manufacturer's Data Reports to tHe attached t l  !

e t  !

I l l [

i CERTIFICATE OF COMPLIANCE  ;

i We certify that the statements made in the report are correct and this DM ==a"* conforms to the rules of the .-

l ASME Code, Section Xl. "******"'  !

t l

! i Type Code Symbol Stamp NONE ,

l l

Certificate of Authoritation No, NA Expiration Det, NA  ;

Signed '

Date  ! 19

' owner /or ownerf opsionse, titse 0 i

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New . Tere:ev and employed by H.S.B.I.&I. Company og Hartford, Ct. have inspected the components described in this owner's Report during the period February 17, 1993 December 15, 1994 . and state that l

! to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this l Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate recither the inspector nor his employer makes ariy warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer f shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB5478 (I) (N) NJ442

~et. n ..e,.. . tete. ,r...nc.. eno a no r mont.

,es,enop.on.ts,e f .

Date hw f tofr i (12/82) l

, - . e w , , - , , e --

. ..= . . .___. - - - - .. . - _ . __

l 1

l L

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

,, 3 ,,, Jersey Central Power & Light f// g g g /99 7 {

Madison Avenue & Purft'f! Bowl Road

~

Morristown, N.J. 07960 Sheet / of 8 Address l

2. Plant ___Ovster Creek NGS Unit Oyster Creek N*** l U.S. Hwy. 9 l Forked River, N.J. 08731  ?

Acereas nepair orsentastion P.O. No., Joe No., etc.

3. Work Nrformed by GPU Nuclear Corporation Type Code Symbol Stomp NONE j Au' thorization No. NONE.

One Upper Pond Parsienanv. N.J.Road.. 07054 Empiretion Date NONE j

Aeoness

4. Identification of System Reactor Recirculation System .

I S. (a) Applicable Construction Code B31.1 - ig 55 Edition. Addende, I

Code Csee (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 R6 f i

! 6. Identification of Components Repaired or Replaced and Roolecoment Components i

l ASME I

5 Code National Repaired, Stemped s Name of Name of Manufacturer Board Reptoced, Other Year (Yes Component Manufecturer or Replacement or No)

Serial No. No. Identification Built

^l n NA NA NA NA leplacemen; NO P-37-001 l

P-37-002 NA NA NA NA " "

l l j l P-37-003 "

NA NA NA NA " " j l .

l

( w_

^  %

7. Description of Work The Reactor Recir pumps ' bolting was ' replacedi
8. Tests Conducted: Hydrostatic l Pneumatic 0 Nomine! Operatirq Pr asure {

Other Q Pressure 1050 psi Test Temp. 'F i

' NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, prrwided (1) size is 84 in. x 11 in., (2) Informs.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

l. .

I

~- - -. .. ._,.

l

[

W FORM NIS 2 (Back) 9 Remarks Appl 6 cable Manufacturer's Date Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code. Section Xl.

l Type Code Symbol Stamp NA Certificate Authorization No. NA Expiration Date M l

Signed  ! bMM b- Date

~

19 Own'e/ or owner signes, Title g I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of New 3ere:ev and employed by H.S.B.I.&I. Company og Hartford, Ct* have inspected the components described in this Owner's Report during the period February 17, 1993 to December 15, 1994 _ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed of amplied, concerning the

~

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

NJ442 Commissions NB5478 (I) (N) inspectcies s.o%atGre' g Nationel Board, State, Province, and E ndorsements Date BA 19 l l

(12/82) l l

i FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI I  !

! 1, Owner Jersey Central Power & Light pgg g gy Madison Avenue & Pudt*HBowl Road '

Morristown, N.J. 07960 AOdrese sheet "

/ of '

Y t 2. Plant _ . Oyster Creek NGS Unit Oyster Creek l U.S. Hwy. 9 N'** )

. Forked River, N.J. 08731 Adoress  !

Repelt Orpenlastion P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp NONE One Upper Pond Road "***

NONE.

Aut'horization No.

Parsippany. N.J. 07054 Empiretion Date NONE Address

4. Identification of SystemControl Rod Drive Hydraulic
5. (a) Applicable Construction Code M1 1 19 55 Edition, Addenda. Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86
6. Identification of Componems Repaired or Replaced and Replacement Components ASME Code National Repaired. Stamped Name of Name of Manufacturer Board Other Replaced, Component Year (Yes  ;

Manufacturer Serial No. No. or Replacement or No)

Identification Built t

SEE ATTACllED N

N 1 I

N m

~

N -

7. Description of work Bolting on the Control Rod Drives were replaced
8. Tests Conducted:

Hydrostatic 0 eneumatic 1050 0 Nominal Operating Pressure @

Other O Pressure psi Test Temo;225 .p l NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (

tion in items recorded 1 through et the top 6 on this report is included on each sheet, and (3) each sheet is numbered and the numbe of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St. New York N

. l

l I i

b l

i c

i FORM NIS 2 (Back)  !

l t

\

+

l 9. Remarks l Applicable Manufacturer's Data Meports to be attached ,

I I

f I

i i

CERTIFICATE OF COMPLIANCE  ;

I We certify that the statements made in the report are correct and this Reclacementconforms to the rules of the ASME Code,Section XI.  ;

r i r

i Type Code Symbol Stamp NONE ,

Certificate of Authoritation No. N/A Expiration Date N/A l Signed SA W 'N?flbl *US YM v Date ' ~l~ 19 Owner or Owne eseenee,' Title v  ;

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State .

or Province of New Jere:ev and employed by H.S.B.I.&I. Company og Hartford, Ct. have inspected the components described  !

in this Owner's Report during the period February 17, 1993 to December 15, 1994 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this l

l Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer  !

shall be liable in any manner for any personal injury or property dama0e or a loss of any kind arising from or connected with this inspection.  ;

  1. Commissions NB5478 (I) (N) NJ442

~.t.on., pos,o. .,a,e, ,,.. n.e. .no . noo,,emen,s

.ne,uem' .e f Date u- f is @

(12/82)

NIS-2 i

6. Identification of components Repaired or Raplaced and Replacement components ,

Attachment NAME OF REPAIRED, ASME i NAME OF COMPONENT REPLACED, CODE i MANUF. OR REPLANCEMENT STAMPED l (rES OR NO)  :

CONTROL ROD DRIVES BOLTING GENERAL REPLACED NO .

14-27, 18-27, 18-35 ELECTRIC t CONTROL ROD DRIVES BOLTING GENERAL REPLACED 'NO i 18-47, 18-51, 22-15 ELECTRIC ,

CONTROL ROD DRIVES BOLTING GENERAL ' REPLACED NO 22-19, 22-27, 26-27 ELECTRIC-CONTROL ROD DRIVES BOLTING GENERAL REPLACED NO 6 30-27, 30-39, 34-39 ELECTRIC CONTROL ROD DRIVES BOLTING GENERAL REPLACED NO 34-47, 42-31, 42-43 ELECTRIC d

l Page 3.og.3

, - , - . ,,y-.- v-w , . - - , - - - , , ,, -

. , _ . -,, ,, - .--,m-..-s.~ ,, y-y,.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Jersey Central Power & Light ggg g 3, g o,,

gy.

Madison Avenue & Purft'HBowl Road '

Morristown, N.J. 07960 Address 3h , / ,, 3 2.' Plant Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 "***

Forked River, N.J. 08731 Address Repair Orsenization P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp NONE One Upper Pond Road "***

NONE~

Authorization No.

Parnipnanv. N_3. 07054 Expiration Date Address NONE

4. Identification of System Core Spray SYS_ tem
5. (e) Applicable Construction CodeB31.1 1g 55 Edition, Addende- Code Case

- (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National Repaired, Stemped Name of Name of Manufacturer Board Other Year Replaced. (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or No) c:FF ATTACHED N

N w

N N

7. Description of Wrnk Valve Bolting was replaced
8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure OtherO Pressure 1050 _psi Test Temp.500 .p NOTE:

Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) sire is 8% in. x 11 in,, (2) informe.

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) mey be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

..m -

e

. y e

t t

I s

i i

FORM NIS-2 (Back)

[

9. Remarks l Applicable Manufacturer's Data Reports to be etteched j

(

i i

I t

CERTIFICATE OF COMPLIANCE i i

We certify that the statements made in the report are correct and this h'M wmmt conforms to the rules of the ASME Code, Section Xl.

?

Type Code Symbol Stamp MnNP f I

Certificate of Authorization No. Nnu" Expiration Date unur f Signed b < - Date 19 owned or ownersgenee Tdie g  ;

v CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by ll . S . B. I . &I . Company og l Hartford, Ct. hwe inspected the components described I in this Owner's Report during the period February 17, 1993 December 15, 1994  ; n'd state that to [

to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this

{

Owner's Report in accordance with ths requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the I

examinations and corrective measures described in this Owner's Report. Furghermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this f inspection, 4 IA Commissions NB5478 (I) (N) NJ442

~et one ..e,o. utet.. . ov.n.e. enu nooreernents I nsouors ..,n.tu,ef  ;

oate M/u 9 iS_gr {

(12/82)

I O

f 1

l r

l I

i I

i i I i

1 l 518-2 l i i >

6. Identification of components Repaired or Replaced and Replacement cosaponents

{

Attachment j t

MAME OF REPAIRED, ASME l MAME OF COMPONENT REPLACED, CODE I MANUF. OR REPLANCEMENT STAMPED (rES l OR NO) ,  !

V-1-0173 REPLACED NO  ;

BOLTING  !

V-1-0175 REPLACED NO }

BOLTING >

V-1-0176 REPLACED NO BOLTING V-20-0015 REPLACED NO BOLTING V-20-0021 REPLACED NO BOLTING V-20-0040 REPLACED NO BOLTING V-20-0041 REPLACED NO BOLTING -

I i

l l

Page 3-of-3 i

l I

e t

i l

FORM Nis 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI g , gn,, Jersey Central Power & Light Madison Avenue & Purft'HBowl Road

, gggg gg - '

i Morristown, N.J. 07960 Adereas Shee / of .I

2. Plant Ovster Creek NGS Unit Oyster '.:rcak U.S. Hwy. 9 " * "

Forked River, N.J. 08731 Adereen }

Repair oreenlastion P.O. No., Job No,, etc. l

3. Work Performed by GPU Nuclear Corporation Type Code Symbol stamp 'R One Upper Pond Road "*" _

Authoriration No. 992-

_Parnippany. N.J. 07054 Empiretion Date 4/13/95 Address

4. Identifiestion of System Isolation Condenser System

)

5. Is) Apphceble Construction Code B31.1 ,, 5 5 Edition,- Addende- Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 R6 j
6. Identification of Components Repaired or Replaced and Reoiscement Components i ASME Code i National Repaired, Stamped Name of Name of Manufacturer Board Replaced, {

Component Other Year (Yes Manufacturer Seriel No. No. Identification or Replacement or No) i Built j

)

SEE ATTACHED '

N N l w

N m

w N

7. Description of work Clamps re-welded to pipe after removal for MSIP of adjacent weld B. Tests Conducted:

Hydrostatic 0 eneumeric 0 Nominal Operating Pressure O Other Pressure psi Test Temp.

NA

'F NOTE: Supplemental sheets in form of lists, sketches. or drawings may be used, provided (1) sire is 84 in. m 11 in (2) informs.

tion in items 1 through 6 on this report is included on sech sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 4 7th St., New York, N.Y.10017 a.

i I

f l FORM NIS 2 (Back)  :

I

9. Remarks Applicable Manufacturer's Data Reports to be attached I l

t

. \

i l,

CERTIFICATE OF COMPLIANCE i We certify that the statements made in the report are correct and this Reni acoment conforms to the rules of the .- .

ASME Code,Section XI. [

l i

i Type Code Symbol Stamp R Certificate of Authoritation No. 992 Expiration Date 4/13/95 l Signed

! N'

  • Date 19 g

eenee, Title  ;

' Owner [or Owner N '},

CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Provmee of New Jersey and employed by H.S.B.I.&I. Company og  ;

Hartford, Ct. have inspected the components descrited I in this Owner's Report during the period February 17, 1993 to December 15, 1994 _ and state that l

to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describod in this l Owner's Report in accordance with the requirements of the ASME Code,Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer

( shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection,

' Commissions NB5478 (I) (N) NJ442 ineoector's S'Onsture [ National Board, State, Provmce, and E ncoreements Date 44- 19 b 1t?/82) l l

l I

l l

t _

l

i

. . f i

NIS-2

6. Identification of components Repaired or Replaced and Replacement components Attachment NAME OF REPAIRED, ASME NAME OF COMPONENT REPLACED, CODE MANUF. OR REPLANCEMENT STAMPED (YES OR NO)  ;

V-1-0173 REPLACED NO BOLTING V-1-0175 REPLACED NO BOLTING i V-1-0176 REPLACED NO BOLTING ,

V-20-0015 REPLACED NO [

BOLTING  ;

l V-20-0021 REPLACED NO ,

BOLTING V-20-0040 REPLACED NO  !

BOLTING V-20-0041 REPLACED NO BOLTING J l

Page 3-of-3 1

l

l 1

i i l  !

i l

J l

FORM Nls.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS

{ As Required by the Provisions of the ASME Code Section XI i

\

1. k ner Jersey Central Power & Light gygg gpf .

Madison Avenue & PudtRfBowl Road ' ~

Morristown, N.J. 07960  ! Y Sheet of Addreas f

2. Plant Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 "*"'"

Forked River, N.J. 08731 l Address Repelf Oreenlastion P.O. No., Job No., etc.

3. Work Performedby GPU Nuclear Corporation Type Code Symbol Stamp ^R~  ;

One Upper Pond Road N*"'*

Authoritation No. 992 l

Parsipoanv. N.J. 07054 Expiration Date 4/13/95 Address

4. Identification of System Isol.ition Condenser System .

k

5. (e) Applicable Construction Code B31.1 3g 55 Edition, Addende, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 Bfi _

j

6. Identification of Components Repaired or Replaced and Replacement Components i

I L

ASME Code (

National Repaired, Stemped i Name of Name of Manufacturer Board Other Year Replaced, (Yes i Component Manufacturer Serial No. No. Identification Built or Replacement or No) l 1 l 1 l

SEE ATTACHED

  • l l

N.

~

N I

w N

7. Description ot Work Clamps re-welded to pipe after removal for MSIP of adjacent weld
8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure OtherO Pressure psi Test Temp. 'F NA NOTE:

Supplementd sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in, a 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., Af 1!,345 E. 47th St., New York, N.Y.10017 l

j .eme.

  • I

]

t I

r

?

I FORM NIS 2 (Back)  !

9. Remarks ,

Applicanie uenufacturer's cate Pieports to be ettsche.

I i

I h

t f

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reni acoment conforms to the rules of the ASME Code, Section Xl.

I t

i Type Code Symbol Stamp R .

I Certificate of Authordation No. 992 Expiration Date 4/13/95 {

- MDA Date 19 Signed - Owner [or owner sense, Title g N ,f CERTIFICATE OF INSERVICE INSPECTION l 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State  !

or Province of New .Tersey and ompioved by H.S.B.I.&I. Company a, Hartford, Ct. have inspected the components described in this Owner's Report during the period February 17, 1993 go December 15, 1994 . and staie thet . j to the best of my knowledge and belief, the Owner has performed examinations and taken correcthe measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. ,

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the .li examinations and corrective measures described in this Owner's Report. Farthermore, neither the inspector nor his employer j shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from of connected with this  !

inspection.

Commissions NB5478 (I) (N) NJ442 in .aors ...n.ture f ~ etion ..e,.. .tet.. ...in... en. .n.or m.nts  !

i Date L*- 0 19 ?T t (12/P21 l

1 l

i l

I f

i 3

l NIs-2  :

6. Identification of components Repaired or Replaced and Replacement coa.ponents ,

l Attachment l NAME OF REPAIRED, ASME '

i NAME OF COMPONENT REPLACED, CODE l HANUF. OR REPIANCEMENT STAMPED l

(TEs OR NO) 211-BP-X-38-85-1-0039 A GPUN REPIACED NO l INTEORAL ATTACEMENT WELD 211-BP-I-35-88-1-0039 B GPUN REPLACED No f i INTEGRAL ATTACEMENT WELD f I  !

l t

l .

Page 3-of-3 l

I l l

l.

1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i

i

1. Owner Jersey Central Power & Light Madison Avenue & PurftN! Bowl Road gg g g gy .

Morristown, N.J. 07960 Addreas Sheet / of E

2. Plant Ovster Creek NGS Unit Oyster Creek i U.S. Hwy. 9 N* '"'

Forked River, N.J. j 08731 Address 1 Repolr orpentration P.O. No., Joo No., etc.

I 3. Work Performedby GPU Nuclear Corporation Type Code Symbol Stamp NONE  !

! One Upper Pond Road Narne Authorization Nd. NONE ,

Parnippany, N.J. 07054 Empiretion Date NONE Address {

4. Identification of System Main Steam System i

S. (e) Applicable Construction Code B31.1 _39 55 Edition, '

Addende- Code Case lb) Applicable Edition of Section XI Utilized for Repeirs or Replacements 19

6. Identification of Components Repaired or Replaced and Replacement Components l

l i l  !

i ASME t Code .

7 Nationel Repaired, Stemped 5 Nome of Nome of Manufacturer Board Other Year Replaced, (Yes >

Component Manufacturer Serial No. No. Identification Built or Replacement or No) '

I RFP A'PTArNPn 1 l  %

I W I N l m

w

, i

, x .

l

7. Description of Work Boltina was replaced on the valves B. Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nomiasi opersim,25 Pressure @

poi Test Temp. 2 Other O Pressure 1050 .,

, NOTE:

Supplemental sheets in form of lists, sketches, or drowings mey be used, provided (1) sire is 8% in. e 11 in, (2) Informe-(

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l (12/B2)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i

i e

i .w.

FORM NIS-2 (Back) .

9. Remarks Appiketzte Manufacturer's Date Reports to t>e attached '

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Mppl epmnMeonforms to the rules of the ASME Code,Section XI. **''***'"*"'

Type Code Symbol Stamo NOMP Certificate of Authorization No. N/A Expiration Date N/A Signed A

~ Nwnek or Owner-llN lSlbOM} 00 Y %-

ence, Tit,e g Date Y~l 19 W' CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure vessel inspectors and the State or Province of Mew Jersey and employed by H.S.B.I.&I. Company og Hartford, Ct. have inspected the components described in this Owner's Report during the period February 17, 1993 to December 15, 1994 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or amplied, concerning the Osaminations and corrective rnessures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this ir+spection.

I -

Commissions NB5478 (I) (N) NJ442

.n - , m n. m y ~ et,ons, .e.,.. .t.... P,0. n.e. .n. . n.._ents Date ~ho e i ir n.

(13/82)

_u_

l 1 l

NIS-2

6. Identification of components Repaired or Replaced and Replacement components Attachment NAME OF REPAIRED, ASME ,

NAME OF COMPONENT REPLACED, CODE l MANUF. OR REPLANCEMENT STAMPED (TEs l OR NO)  ;

V-1-0010 REPLACED NO BOLTING  ;

V-1-0164 REPLACED NO BOLTING i 1

V-1-0165 REPLACED NO l BOLTING i V-1-0166 REPLACED NO V-1-0167 REPLACED NO BOLTING V-1-0168 REPLACED NO BOLTING b

1

Page 3-of-3 l

l l

l l

l

i

. . l 6

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Light ggg g gp i

l Madison Avenue & Purft*m5 owl Road '

Morristown, N.J. 07960 /

Address sh , o, 3

2. Plant Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 "***

Forked River, N.J. 08731 Address Mapelt orpenization P.O. No., Job No., etc.

3. Work Parformed by GPU Nuclear Corporation Type Code Symbol Stamp R One Upper Pond Road "*""

Authorization No. EN parsinpanvf N.J. 07054 Expiration Date 4/13/95 Addreae

4. Identification of System Reactor Head Cooling System.
5. (a) Applicable Construction Code B31.1 39 55 Edition, Addenda _. Code Case j (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 A6
6. Identification of Components Repaired or Replaced and Replacement Components I ASME Code National Repaired, Stamped Name of Name of Manufacturer Board Other Year Replaced, (Yes Component Manufseturer Serial No. No. Identification Built or Replacement or No)

SEE ATTACHED N

'N 1

N_  %

N -.

7. Description of Work Replace valve V31-0005 and connecting piping
8. Tests Conducted: Hydrostatic @ Pneumatic 0 Nominal Operating Pressure Other O Pressure 1900 psi Test Temp. 'F l

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is BM in. x 11 in., (2) Informs-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l

l

- em - ,,

j

l. . .

l ,

l i

i FORM NIS 2 (Beck) I

9. Remarks ,

Applicable Manufacturer's Data Reports to be attached

{

f F

l l

l .

t '

l /

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this aCOEed conforms to the rules of the j

D**'"**'*****"'

ASME Code,Section XI.

i Type Code Symbol Stamo n  !

i 992 Expiration Date April 13' 1995  ;

Certificate of Authorization No.  ;

Signed b M 3 Date  ! 19 [

l oher pr owner's D nee, Title O CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of. New Jersey and employed by H.S.B.I.&I. Company og Hartford, Ct. have inspected the components described 'k in this Owner's Report during the period February 17, 1993 to December 15, 1994 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this ,

Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his ernployer makes any warranty, expressed or emptied, concerning the  ;

examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector por his employer f

! shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this {

inspection. ,

1 l

Commissions NB5478 (I) (N) NJ442 l ingEtori s.enature National Board, State, Province, and E ndorsements ,

Oa,e k 9 ,, er i b

(12/82) l  :

l i

1 j

1 l

I i ,

i l

1 4

NIs-2

6. Identification of components Repaired or Replaced and Repiscenent cosaponents i

1 Attaciunent

. 4:m=

NAME OF REPAIRED, ASME i 'NAME OF COMPONENT REPLACED, CODE MANUF. OR REPLANCEMENT STAMPED (TEs oR NO) i REC-2-0060 GPUN -REPLACEMENT NO .

WELDED i i RBC-2-0061 GPUN REPLACEMENT NO i WELDED  !

i REC-2-0063 GPUN REPLACEMENT NO

, WELDED *' ,\ <

J i REC-2-0064 GPUN REPLkCEMENT NO I i WELDED I l

REC-2-0065 GPUN REPLACEMENT MO i a

WELDED REC-2-0066 GPUN REPLACEMENT NO l WELDED  ;

VALVE V-31-0005 EDWARDS REPLACEMENT NO WELDED \

1 1

Page 3-of-3 1

i 4

4 I

S

~ - -

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS >

As Required by the Provisions of the ASME Code Section XI i

1. Owner Jersey Central Power & Light Madison Avenue & Purftim5 owl Road ggg g '

gg i

Morristown, N.J. 07960 Adoroes Sheet / of I  ;

2. Plant Ovster Creek NGS Unit Oyster Creek U.S. Hwy. 9 "*** '

Forked River, N.J. 08731 Address Repelr Creenization P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp R One Upper Pond Road "'**

Authorization No. 992 Pa r e:1praanv . N.J. 07054 _ Expiration Date 4/13/96 Address 4 Identification of System Reactor Head Vent System . >

5. (a) Applicable Construction Code
  • 19 Edition, Addende- Code Case i (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86
6. Identification of Components Repaired or Replaced and Replacement Components t

ASME Code National Repaired. Stemped Nome of Name of Manufacturer Board Other Year Replaced, (Yes  ;

Component Manufacturer Serial No. No. Identification Built or Replacement or No) f SEE ATTACHED  !

' i l

w

~ i N

N x

7. Description of Work Replace valve V-25-0022
8. Tests Conducted: Hydrostatic @ Pneumatic Nominal Operatirig Pressure Other] Pressure 1588 psi Test Temp. 'F NOTE:

Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) i This Form (E00030) mey be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

{

l l

i

.I e l i

4

.t

- FORM NIS 2 (Back)

< t e

9. Remarks Aoplicable Manufacturer's Date Reports to De etteched ,

i l

P t

[

i

+

1 CERTIFICATE OF COMPLIANCE t We certify that the statements made in the report are correct and this Replacement conforms to the rules of the  !

ASME Code,Section XI.

~

! Type Code Symbol Stamp R 992 Certificate of Authorizatlon No. Expiration Date April-13, 1995  !

Signed O bI b O O Date ~! 19 '

' owner 8er owner syenee. Titie g CERTIFICATE OF INSERVICE INSPECTION - -!

t, the undersigned, holding a valid commission issued tw the National Board of Boiler and Pressure vessel inspectors and the State I or Province of Now JTermey and employed by H.S.B.I.&I. Company ,, i Hartford, Ct. have inspected the components described  !

December 15, 1994 '

in this Owner's Report during the period February 17, 1993 to . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this -

Owner's Report in accordance with the requirements of the ASME Code,Section XI. j By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the '

examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer +

! shall be liable in any manner for any personal injury or property damage or a foss of any kind arising from or connected with this inspection. $

E Commissions NB5478 (I) (N) NJ442 ,

Nationes soara, state. Province. and Endorsemente -

anptoFs s.ensture g  ;

Date fH- 19 I

(12/82)  :

1 I

l l

l I

l I i

a 1

- E

l l

NIS-2 l

6. Identification of components Repaired or Replaced and Replacement components l Attachment NAME OF REPAIRED, ASME  !

NAME OF COMPONENT REPLACED, CODE MANUF. OR REPIANCEMENT STAMPED l (YES OR NO)

MV-5-OO37 GPUN '

REPLACEMENT NO WELDED  ;

MV-5-OO3B GPUN REPLACEMENT NO WELDED i

VALVE V-25-OO22 VALCOR REPLACEMENT NO WELDED ,

1 Page 3-of-3 i

l l

I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Jersey Central Power & Uaht Date M[

[d Nf Name Madison Ave.& Punchbowl Rd., Morristown, N.J. 07960 Sheet / of 2 Address

2. Plant Ovster Creek NGS Unit _Ovster Creek Name U.S. Hwv.9 Forked River N.J. 08731 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by GPU Nuclear Corporation Type Code Symbol Stamp Name Authorization No.

One Upper Pond Rd. Persioenny. N.J. 07054 Expiration Date Address

4. Identification of System Reactor VesselInternals
5. (a) Applicable Construction Code ef Af8 .I 19__ Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 82 ,

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this modifiestion conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NONE Certificate of Authorization No. NONE Expiration Date N/A Signe ~ Owner'or Owne

' llY6l $2ht lA l Date N0 19 esigrios, Title I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesset inspectors and the State or Province of New Jersev and employed by H.S.B.I.& l. Company of Hartford. Ct. have inspected the components described in this Owner's Report during the period February 17.1993 to December 15.1994.and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector not his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB5478 (t) (N) NJ442 Irdp'ector's Signatdfe National Board, State, Province, and Endorsements Date MtM. M 19b i

ma oa FORM NIS 2 (Back)

6. Identification of Components Repaired Replaced and Replacement Components Repaired, ASME Code Name of Name of Manufacturer National Other Year Replaced, or Stamped Component Manufacturer Serial No. Board No. Identification Built Replacement (Yes or No) t Core Shroud Avery None None 1965 Mod No
7. Description of Work Nont welded reonir. Tie rode were installed.

kk

8. Tests Conducted: Hydrostatic O Pneumatic O Nominal Operating Pressure O N/A Other O Pressure psi Test Temp. 'F 8

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) sire is 8-1/2*x 11",

(2)information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9. Remarks This raDair followed the ovidence of ASMS Section XI 1989 Edition where possible.

Applicable Manufacturer's Data Reports to be attached l

l i

l l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i

1. Owner Jersey Central Power & Uoht Date March 10,1995 Name Madison Ave.& Punchbowl Rd., Morristown, N.J. 07960 Sheet 1 of M Address
2. Plant Ovster Creek NGS Unit Ovster Creek '

Name

_ U.S. Hwv.9 Forked River N.J. 08731 Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporotion Type Code Symbol Stamp Name Authorization No.

One Upper Pond Rd., Persioanny, N.J. 07054 Expiration Date i Address

4. Identification of System See Remarks

?

5. (a) Applicable Construction Code B31.1 19 55 Edition, NA Addenda, NA Code Case '

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 86

[

i h

CERTIFICATE OF COMPLIANCE '

We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI. [

repair or replacement  :

I Type Code Symbol Stamp NONE t

Certificate of Authorization No. NONE Expiration Date N/A Signed ud / # Date /MI# /d .19 [I 5v/ner opn'Fs Cesignes, Title f CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesselinspectors and the State or Province of New Jersey and employed by H.S.B.I.& l. Comoany of Hertford, Ct.

have inspected the components described in this Owner's Report during the period February 17,1993 to December 15,1994.and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificato neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector not his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.

s, / Commissions NB5478 (t) (N) NJ442 Indfe'etor's Signature / National Board, State. Province, and Endorsements Dete Y8 191 as cu 1 i

l l

FORM NIS-2 (Bock)

6. Description of Work Replacements performed not by weldina.
7. Tests Conducted: Hydrostatic D Pneumatic D Nominal Operating Pressure N/A Other D Pressure psi Test Temp. *F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2*x 11",

(2)information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

B. Remarks This report is for multiple svetems. The pressure testina that was performed satisfied desian for hydros or nominal (Applicable Manufacturer's Data Reports to be attached) operatina pressure for inservice.

9. Identification of Components Repaired Replaced and Replacement Components SEE ATTACHED Repaired, ASME Code Name of Name of Manufacturer National Other Year Replaced, or Stamped Component Manufacturer Serial No. Board No. Identification Built Replacement (Yes or No)

'N

'x s

\ x Ns

\

\

N s

\ sN

\

Ns Ns l \ s

\

\

\ ,

I DNkt Ga i

l

.__. m m_ _ . _ _ ._m,__.. _ _ _. -._.i.-.. .. . .. .-_m . . - . . .

-(

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee ~- ' *

  • CYCLE JOB STAT CRAFT WELD !$1 ANI. SYS COMPONENT DESCRIPTION
  • e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee r .. . o - - e e e M e eM e e e e e e e e e 14 48287 CLSD MECH N Y 4 541 H-5-001//HTEXCH
  • RB CLOSED COOLING WATER HEAT EXCHANGER 1-1 THE RETURN CHANNEL HEAD FOR THE 1-1 RBCCW HEATEXCHANGER SHOU LD.BE REPLACED. THE HEAD WAS DAMAGED " GALANT 0" AND NEEDS REPAIR. THE DAMAGED "0RIGINAL COPY DISTROVED IN PRINTING" 14 49193 CLSD MECH N Y 4 532 V-3-0131// VALVE Sws TO CONTAINMENT SPRAV HEAT EXCHANGERS 1-3/1-4 V-3-131 WAS FOUND TO BE STUCK OPEN DURING THE-AUGUAUGUST IN SERVICE TEST. PLEASE INVESTIGATE. REPAIR OR' REPLACE. VERIF V VALVE IS INSTALLED IN CORRECT CONFIGURATION.

14 49842 CLSD MECH N Y 5 532 V-3-0131// VALVE Sw$ TO CONTAINMENT SPRAY HEAT EXCHANGERS 1-3/1-4 RECLACE/ REINSTALL V-3-131/133 14 50564 CLSD MECH N V V 531 P-3-001A//PUMD SERVICE WATER SYSTEM PUMP 1-1 REPLACE PUMP w!TH A REBUILT SPARE OR NEW ASSEMBLY FROM STORE 5.' REMOVE AND REPLACE / REUSE THE MOTOR.

?4 50698 CLSD MECH N Y 5 532 V-3-0065// VALVE EMERG*v SERVICE WATER PMP1-4 DISCHARGE CHECK VALVE PREDICTIVE MAINTENANCE INDICATES CHECM VALVE 15 wCRN AND MAY BE STICKING OPEN. REPLACE DURING pump REPLACEMENT worm i4s 35958 CLSD CNTR N

  • 4 215 .

V-16-0076// VALVE i

' DEMINERALIZER LINE RELIEFVALVE TO SUPPRESSION POOL SUSPECT RELIEF VALVE IS. LEAKING BY. PLEASE REPLACEVALVE WITH VALVE FROM STORES -

'Ac 37360 CLSD CNT* N Y 4 532 532// SYSTEM

' EMERGENCY SERVICE WATER SYSTEMS-3 EMERG SERVICE WATER PIPING INSPECTION / MINOR REPAIR

\

94: 37527 CLSD MCc8 N v 4. 531 V-3-0033// VALVE SwS PUMD 1-1 DISCHARGE HEADER VALVE VALVE V-3-0033RIS VERY DIFFICULT TO OPERATE AND ENGINEERIN

-G PREDICTS THAT V-3-0034 WILL SOON EMPERIANCE THE SAME PROBL EM. REDLACE BOTH VALVES. ** THIS 15 A MULTI-COMP 0NENT J0. **

'4: 36243 CLSD M o* N v 3 24' V-21-0021// VALVE .

CSS HEAT EXCHGR H-21-001ATHERMAL RELIEF VALVE IST PROGRAM AND TECH SPECS 4.3.C REQUIRES REPLACEMENT OF THE'--

FOLLOWING RELIEF VALVES.V-21-21.22.23.24.AND V-3-82.83.84,8

_ _ . _ _ ._ -.____._--m m..-____. _--- - - - - - - - - - - - - - - - - - - - - - - - - - - '---- - "' ' " * " - ^ ' " * ' * ~ ^ ~ - ~ ~ - ~ ~ ~ " * * ' ~ ~ * * '

seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesseeese

  • CVCLE JOJ STAT
  • CRAFT WELD I5I ANI SYS COMDONENT DESCRIPTION
  • e e e.ee eeeeeeeeeeeeeeeeeeeeeeee.seeeeeeeee..ee.es....ee.....eeeeeee.e ee....ee......e.e.ee................... y y, e

. heAe.g iese p w@esees ,

5 IN 14R 14R 42161 CL5D MECH N V 3 213 V-59-0044// VALVE EXPLOSIVE INJECTION VALVE (NP05-A)

REPLACE V-19-44 AND V-19-45 AFTER FUNCTIONAL TEST IS PERFORM ED, PER A100-5MM-3219.02 15R 50587 CLSD CNTR N Y 4 54' V-5-0165// VALVE DRVWELL EQUIPVENT COOLINGINLET CHECK VALVE REPLACE VALVE WITH NEn.

15R 54025 CL5D WECH N v 3 213 V '9-0044// VALVE EMPLO5IVE INJECTION VALVE (NDC5-A)

REPLACE V-19-C044 AND V-19-0045 wwEN 612.4.002 15 PERFORVED cEn At00-5vu-3219.02. SEE STED 6.38 AND 6.39 05 61 2.4.002.

tSR 54233 COUD CNTc N v 4 212 v-20-0015// VALVE COEE SDRAv Sv5.I DamALLELIsciATION VAL %E C3GE SDRA* SAL'vE :EDAIS & MODI *ICATION

-

  • A a. - & . ._ m _s.m-_- . uan. e,,,-_a. 2 -.__a .m, _. _...u.. e _ w._ 4 s. am..

4 4

-I i

i i

5 1

1 1

1 s

I I

i I

6 h

. 8P -

)

g I

b

.c 1

s A

i

-1g n

a r

b I

t 6

L

?

k 4

7 I

J i

l l

l l

I i

- ~ p

I t

l e .

l I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI l

t

1. Owner Jersev Central Power & Ucht Date March 10.1995 Name Madison Ave.& Punchbowl Rd., Morristown. N.J. 07960 Sheet 1 of Address
2. Plant Ovster Creek NGS Unit Ovster Creek l Name

\

l _ U.S. Hwy 9. Forked River. N.J. 08731  !

Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by GPU Nuclear Corporetion Type Code Symbol Stamp Name Authorization No. l One Vocer Pond Rd Persioennv. N.J. 07054 Expiration Date Address 4 Identification of System See Remarks l 5. (a) Applicable Construction Code B31.1 19 55 Edition, NA Addenda, N A Code Case l (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 8,L l I

i CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this both conforms to the rules of I the ASME Code,Section XI. repair or replacement I l

Type Code Symbol Stamp NONE Certificate of Authorization N NONE Expiration Date J/A Signed M Date /8 [ .19

' Owr #r [Owne'r's Designee, Title '

1 i

CERTIFICATE OF INSERVICE INSPECTION l l

1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vesselinspectors and the State or Province of New Jersey and employed by H.S.B.f.& l. Company of Hertford. Ct. have inspected the components described in this Owner's Report during l the period February 17.1993 to Ac,gember 15.1994.and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any worrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

( // Commissions NB5478 (0 (N) NJ442 inspector's Sig6ature National Board, State, Province, and Endorsements Date d- /d 19 (

m aa

( FORM NIS-2 (Back) l l

f

, 6. Description ot Work Repaire end replacements Mrformed by Weldina.

7. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure N/A Other O Pressure es! Test Temp. *F NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, previded (1) sire is 8-1/2*x 11",

(2)Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

8. Remarks This report le for multiple evrtems. The pressure testina that was performed satisfied desian for hydros or nominal (Applicable Manufacturer's Data Reporte to be attached) 1 operatino oressure for in**fVIC'-

l

3. Identification of Componente Repaired Replaced and Replacement Componente SEE ATTACHED Repaired, ASME Code l Name of Name of Manufacturer National Other Year Replaced, or Stamped Component Manufacturor Serial No. Board No, identification Built Replacement (Yas or Nol

\ .

sN

'N s

\

N N

Ns

\

\

N N

Ns Ns

\

\ \

x  !

1 M3 Gil 1

\

I i

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeeeeeeeeeeeesseee e *

  • CYCLE JOB . STAT CRAFT WELD ISI ANI SYS COMPONENT DESCRIPTION
  • e o e e

7.h4F 9 ' *

, t seeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee e fs e Fle m e Fe e s s e e e s - 3 E

14 42934 CLSD MCPF V V V 532 V-3-0131// VALVE SwS TO CONTAINMENT SPRAY HEAT EXCHANGERS 1-3/1-4 REPLACE V-3-131 WITH NEW DUO-CHECK. TH IS IS A CO RRECTCORRECTIVE CHANGE PER 125-1 52-92. INSTALL NEW HARDWARE PER THE 14 54345 CLSD MECH V V 5 211 V-14-0030// VALVE STEAM INLET VALVE TO 'A* EMERGENCY CONDENSER PERFORM UT INSPECTIONS Op VALVE STEMS ON V-14-30, 31 32 & 33 IN CONJUNCTION WITH OPERABILITY SURVEILLAN CE. ,

14R 26258 CLSD CNTR v v 3 573 573// SYSTEM DRYwELL FLOOR AND EQUIPMENT DRAINS-22 INSTALL BLOCK VALVES UPSTREAM 05 V-22-1 & V-22-28 14R 32366 CLSD MCDF Y 212 Y 4 V-20-0104// VALVE SYSTEM I VENT VALVE NALVE WAS DETERMINED TO LEAK DURING LEAK RATE TEST OF V-40-1

2. VALVE NEEDS TO BE REPAIRED TO DETERMINE LEAKAGE PAST V-40-12. REPLACE VALVE 14R 34384 CLSD MCP* v V 3 424 V-11-0113// VALVE CORE SDRAY FILL & MAKEUP BYPASS VALVE VALVE AppARENTLY LEAKS-BY. CAUSING V-11-0118 TO LEAK REPLACE' DIAPHRAGM IN V-11-118. REDLACE V-11-0112 AND V-11-01131AW F ORu 125-1 P.E. FILE NO.366-92.

42 3440' C SD uCPe v v 3 424 V-11-Ot14// VALVE

. CORE SDRAv FILL & MAMEUP VALVE .-

41 ..

VALVE ADPARENTL4 LEAKS-BY. CAUSING'V-11-119 TO IEAK REPLACE DIAPHRAGM !N V-11-0119 REPLACE V-11-0114 AND,V-0115 IAw F ORM 125-1 P.E. FILE NO.366-92.

'4 3485$ CLSD CNTR v v 4 241 241// SYSTEM CONTAINMENT SDRAY SYSTEM -21 79-14 SUDDORT UPGRADES (NON Dw RAMPup)

'4c 34856 CLSD .CNTP v v 4 241 241-BP-433-R2-0057//SupORT HVDRAULIC SNUBBER (NQ-2-57) 79-14 $UppORT UPGRADE (NON DRvwELL) 4: 34257 CLSD CNTE C v 4 241 241//Sv5TEu- t CONTAINMENT SDRAY SYSTEM -21 79-14 SUPPORT-UPGRADES (DRvwELL) o i

_____ _ . _ _._________.m._ _ . _ _ _ _ _ _ . . _ _ _ _ . _ - - - - . - . . , _...M~,..- ..e....m__.-_._m~ . - . _ , . . . . . . , _ _ _ , _ . . , _ , . , . -_ _ _,..__~ ~ _ _

.e eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee.o

4. CYCLE. JOB' STAT CRAFT WELD ISI ANI SYS ...eeeeeeeeeeeeeeeeeeeee ' *:

COMPONENT DESCRIPTION

  • o , s. *-
y. .

o, eseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee .

selee see esses' i

14R 35013- CLSD MCPF V V 2 411 '

V-1-0186// VALVE PS-RE0023B ROOT VALVE PACKING APPEARS TO BE BLOWN OUT. BLOWING A 2* PLUME  :

OF STEAM. REPLACE VALVE.

  • 14R i

35498 CLSD MCDF v v N 424 '424// SYSTEM.

CONDENSATE TRANS8ER SYSTEM .!

4 A CLAMP WAS INSTALL'AND INJECTED TO STOP LEAMAGE joe 35216.

REMOVE CLAFP AND REPAIR / REPLACE DIPING AS REQUIRED.THIS

. JOB ORDER IS CONSIDERED REwCRM MATS 262-14R 35974 CLSD MCD* v v 3 215 V-16-0030// VALVE . ,

' RELIES TO TODUS TELL-TALEDRAIN. VALVE SOLENOID WA5 REPLACED VALVE STILL INOPERABLE JO TRANSFE RED'TO MECMANICAL *R0w ELECTRICAL REDAIR. REPLACE VALVE AS REQUIRED. MADD COD

  • 08 JO IN FILE.

14R 36099 CLSD CNTA Y v 4 241 241//SYSTEW CONTAINVENT Speav SYSTEM *21 REDLACE HvDRAULIC SNUBBERS w/ STRUTS.(SYSTEUS 2 14 AND 241).

14R 36930 'CLSD CNTR v v 4 212 .

V-20-0052// VALVE CS PUMP NZC3-A DISCHARGE CHECK VALVE (SYSTEW Il DER *04w VALVE w0DIFICATION TO REMOVE kev'FROM' VALVE SMAFT.

, 800 TO BE PEEFORMED.SAME AS V-20-51 CONTACT PE FOR MOD PAC MAGE. PETar 92-054 14R 37082 CLSD MCDF V V 3 5?2 i l (-3-Ot33//VALVEm ..a '

SwS TO CONTAINVENT 5:RAV' MEAT EMCHANGERS 1-1/1-2.

DEDLACE V-3-933 mIT* nee DOO-CMECM. THIS IS A-CORRECTIVE C*aNGE CER.125-1 52-92.' INSTALL NEW HARDW ARE PER TwE *25 ' 804V.

14R 37518 CLSD CNTR v v  ? di*

V-1-0013// VALVE

-STV SEA. DEG,.ATOR BVPAS$4ALvE-

'v '-13 taEwOn* J (ELEC Jos39286)-

t 14R 37524 CLSD 'WCD*.

  • 3 6 '2 ' : .

212//SYSTEW CODE Scrav Sv5TEV.&' AUTO DEDRE550RIZATION-20

!NSTAa. -0SE' CONNECTIONS ON CORE SDRav PUwo CASING VENTS DER INSTRUCTIONS CONTAINED IN OCww-328328-001 14R 38063 CLSD MEC~ v v 2- 225 V-305-0101/02-27/ VALVE-CCD INSEsT SALVE .

CcO- - L WODULE-AEBLILD ON 35 UNITS PER THE DROJ. SDONSORS' I i

i 1

5

' r I

I

._________________.._.______.c_. . ...._.._____..___._____;_,._.._... .u a. c _ _ _ _ _ a _ _ _, _

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeenseeeeeeeeeeeeeeeeeeeeeeeeeeeeesseseeeseeeese**

  • CYCLE e

JOB STAT CXAFT WELD ISI LNI SYS COMPONENT DESCnIATION *

. a

....................................................................................................... . (sc.5.:s7/f.:.F.......

NSTR.ScF*ED IN BA-323629 ANY QUESTIONS CONTACT WALCOLW GONZ ALES,x2176 14R 38599 CLSD CNTR V V 212 1

V-20-0024// VALVE CORE SDRAY SYSTEM RELIEF VALVE (SYSTEM II)

REPLACE V-20-24 & 25 14R 38711 CLSD UECH v v v 225 v-305-0106/14-31/ VALVE ACCUVJLATOR CHARGING WTR R!SER ISOLATION VALVE REPLACE V-305-010E 14-31 VALVE WHICH IS LEAKING. FIRST OFFICIAL CODY Wa$ U!SPLACED AND SECOND ONE ISSUED. ORIGI NAL FOUND AFTER JCB COVDLETED & DESTRCvED JB */ PU 1/7/93.

14R 38712 CLSD VECH v v v 225 v.305-C'06/10-47/va.vE ACCUMJLATOR CHADGING WTR RISER ISOLATION VALVE REC. ACE v-305-0106 10-47 VALVE wwICw 15 LEau!NG.

14R 39741 CLF0 UECH V V 2 221 v-25-0021// VALVE REACT 0A wEAD VENT VALVE RX VENT VALVES v-25-21 & -22 ARE LEAMING THROUGH. REPAIR THE SE VAiv25 AND PROVIDE INc0 70 p_ ANT ENGINEERING COR ROOT CAUSE ANALYSIS 14R 39955 CLSD CNTR Y / 212 1

v-20 0119// VALVE FILL PJVP NZO4A DISCHARGECHECv VALVE Cwr VLv. INST. v-2C-?!9 (Sv5 I) 14R 39959 CLSD CNTR v v 3 422 .-2-0073 itAuvE CEEDnaTE: ISOLATICN C-E:= SALVE TO REACTO:

Cw* , _ . IN50 .-I ~?

14R 40253 CLSD CNTR v v 3 424 'I/SYSTEV CO*. DEN 5 ATE *:ANS*Em Sv5TEV CONr. ?:ANSEEc S<5TEY DIDING REDAIDS 14m 42003 CLSD CNTR v v 53; 532/c5vi'EV EVEcSENC$ SEE ICE % ATE:. S*S*EV5-3 ESn cICI'.a :Ec ACEVE.*

14R 42937 CLSD MECw v v 4 225 t-305-C'38/34-C3rvAivE COD. INS aA*E: 0-E!* 4.*E

  • eesseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeescocesosecoeeeeeeeeeeeeeseeeeeeee CYCLE JOB STAT CRAFT WELD ISI ANI SYS e COMPONENT DESCRIPTION
  • e e
  • f .nf. y * ,

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeese e e s e ese e Yle s e re e e e e e e CRD HCU MODULE REBUILD ON 35 UNITS PER THE PROJ. SPONSORS' I NSTR.REF'ED IN 9A-323629 ANY OUESTIONS CONTACT MALCOLM GONZ ALES.X2176 14R 43034 COMP MECH v v 2 225 V-305-0101/18-39/ VALVE CRD INSERT VALVE CRD HCU MODULE REBUILD ON 35 UNITS DER THE PROJ. SPONSORS' I NSTR.REF'ED IN 84-323629 ANY CUESTIONS CONTACT MALCOLM GONZ ALES.X2176 14R 44064 CLSD MECH v v 2 225 V-305-0106/02-23/ VALVE ACCUMULATOR CHARGING WTR RISER ISOLATION VALVE REDLACE OR REFURBISH VALVE IN ACCORDANCE WITH MAINT, PROCEDU RE A100-GYV-3225.52. PERFORMANCE OF OPS DIAGNOSTIC TEST (6 17.4.013) MJLTI- COUD 14R 440E5 CLSD MECH v w 2 225 V-305-0106/06-35/ VALVE ACCUMacATOR CHARGING WTC RISER ISOLATION VALVE DEPLACE OR REFURBIS* VALVE IN ACCCGDANCE mITH MAINT. DCOCEDL DE A100-Gvv-3225.52. DERrouvANCE 05 O?S. DIAGNOSTIC TEST (

617.4.013) 14c 44066 CLSD MECH v v 2 225 v-305-0106 /4 6

  • 5 / v A LVE ACCUVUmATOR CHARGING WTR RISER ISCgATION VALVE REDLACE OR REFUDDISH VAcvE IN ACCC2 DANCE eIT- VAINT. DCOCEDU RE A100-Gvv-3225.52. DERFORMANCE 08 ODS. DIAGNOSTIC TEST f 617.4.013) 14R 44476 CLSD CNTR v v 4 213 213//5v5TEV LIQUID POISON SYSTEV-19 REDAIR LIQUID POISON PIPING IA* MNCR*92-0536 14 44580 CLSD MECH v v 3 225 V-305-0106/22-31/ VALVE ACCUMasATCR CHARGING mTD DISEC ISC A' ION VALVE PLEASE REPLACE THE 106 VALVE ON hec LNI' NUMBER 22-31 AS DER P WATTERSON mIT* CONCURRENCE Ce Dc0 JECT SPONSOR MALCL OU GONZALES. x2176

'4R 45211 CLSD MECH Y Y 4 532 532//Sv5TEv EVERGENCY SECv!CE MATED SYSTEYS-3 THIS SUPPORT IS CO: CODED AND NEEDS CEDAI:. CErEC ENCE MNCP 93-0060.

  • 5C 45663 COMD MECH w v 2 411 . -0344r va vE Ec*-OOC 3 INSTRuvENT 000' VALcE BODv TC BONNET LEA *: EED_ ACE GAS *ET;;EcAID.GE 5 ACE VALVE (AS EEO'D:. REYOvE SEA ANT DETAINING OE; ICE 0* ;.C. 45E64 ****$

T OCFICIA, COPv DESTc0VED DUE TO DcIN'EC VAL *LNCTICN*** CY>

  • S: 49629 COYD CNTR w V t 212 2127/SvS*EY

4

.seeeeeeeesseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeste *

  • CYCLE ' JO3 STAT CRAFT WELD ISI ANI SYS COMPONENT DESCRIPTION *

. .- ,t

  • D

...................................................................................................... K M .. 7. ... g f.. .v........

9 . ,

CORE SPRAY SYSTEM & AUTO DEPRESSURIZATION-20 CORE SPRAY SYSTEM IMPROVEMENTS 15R 50261 COwP CNTR. w' Y 3 532 532// SYSTEM EMERGENCY SERVICE WATER SYSTEM - 3 EROSION / CORROSION PROGRAM 15R i

15R 50265 COVD CNTR w Y 2 531 531//Sv5 TEM SERVICE WATER SYSTEM-3 SERVICE WATER PIDING REDL 9 INTAME.STRUCT j iSR 53186 COMD CNTR w V 3 532 532// SYSTEM EMERGENCY SERVICE WATER SYSTEM - 3 MM-270 E5W ORIFICE RELOCATION AND REDLACE ELBOW DOWNSTREAV r OF V-3-89. '

154 53427 COMD CNTR w V 2 531 531// SYSTEM SERVICE WATER SYSTEM-3 SERVICE WATER PIPING ON 51* RM' BLDG

?SR 54032 CLSD CNT4 w V 3 532 532//Sv5TEW EMERGENCY SERVICE WATER SYSTEM - 3 9 ESw KEED "ILL LINE THROTTLE va uvE MW-283

'Sc 5589E CLSD WECM m v v 424 D-11-OO1//DLMD CONDENSATE TRANSFER DuMD 1-?

INSTALL EMDANSION' JOINTS IN 0-11-002 AND D-11-OO1 puMD SUCTI ON LINE. SEE OC-CCD-328333-OO3 AND DDAwING 3C-424 1 000. *******THIS IS A MULTIDLE COVDONENT JOB CRDEp*******

152 565T1 Corp CNT4 W V 532 1

532//Sv5TEU EMERGENCY SERVICE WATER SYSTEM - 3 HYDROLASE L MODIFY ESw PIDE @-!NTakE STRJCTUCE *** USE Cw RG e2440-CC506 "OR Hv0ROLASING *** *** U SE CHRG e5518-C0490 FOR MODIFICATION ***

  • ?: 5T349 COUD CNTn Y- V 1 531 531//Sv5?Ev 4 SERV!CE WATER Sv5TEv.3 SERVICE wATEm p!c!NG LEAW REpalc t NE Re I

_ _ _ _ _ _ - _ . _ - - _ . . . , _ . _ . . . _ . _ _ _ _ _ . _ . - . , - . . - - . - _ . _ _ . . . ~ . _ _ ._ _ _

~____.______-..,__.._._._-.._-___4

II 4

! eteeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeeeeese

  • CYCLE JOD e

e STAT CRAFT CELD ISI ANI SYS COMPONENT DESCRIPTION * .

e e .

Q ,jnf.*Q e y eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee ISR o e e m e e We e e ewe e e 4

57696 CLSD MECH Y Y 1 531 531// SYSTEM ,

i SERVICE WATER SYSTEM-3 4 REPLACE 16" FLANGPS FOR V-3-78 AND 79 IAW PLANT ENGINEERIN G EVALUATION FORM 125-1, D.E. FILE

  • 441-94 *****
              • THIS IS A MULTIPLE COMPONENT JOB ORDER *************

15R 57704 COMD CNTR W Y 3 424 424// SYSTEM CONDENSATE TRANSFER WATER $YSTEM-11.CH  !

EXCAVATE. REPAIR CONDENSATE TRANSFER PIPING NEAR COND XFR B LDG.

15R 57785 COMO CNTR v v 3 535 531// SYSTEM SERVICE WATER' SYSTEM-3 i SERV!CE WATER PIPE INSD/ REPAIR AT NW TURBINE BLDG 15R 58793 COMD MECH V V 4 411 V-1-0107// VALVE MAIN STEAM LINE 'B' DRAINVALVE DISASSEMBLE AND REPAIR VALVE V-1-107 50 DPM LEAM 1

)

i 4

d

+

\.

.--_-._.-.---._.--_...__-...--.__....-.---.a..-.:.__,..--._-,-,