I s

.a i

GPU Nuclear Corporation o te ou h Forked River, New Jersey 08731-0388 609 971-4000 Writer's Direct Dial Number:

March 16,1995 C321 95-2113 l

U. S. Nuclear Regulatory Commission l

Att: Document Control Desk l

Washington, DC 20555 i

r

Dear Sir:

t

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Inservice inspection Data Reports in accordance with 10 CFR 50.55a(g) and ASME XI Section IWA-6220,1986 editon with no l

addenda, GPU Nuclear is forwarding the requisite reports resulting from the Inservice Inspection activities conducted during our recently concluded 15R refueling outage.

i l

The NIS-1 inspections which were performed have been separated into two groups. Table I contains a list of inspections performed for ASME Code credit or augmented inspection requirements. Table 2 contains a list of inspections where indications were recorded and resolved. In-vessel visual inspections have been summarized in the abstract section of the NIS-1 form.

The NIS-2 forms, documenting repairs or replacements, are also attached. The repair performed on the core shroud is included in this group.

If any additional information or assistance is required, please contact Mr. John Rogers of my staff at 609.971.4893.

r Jo n J. B on ce President and Director l

l yster Creek JJB/JJR g.3000 g Attachments l

I cc:

Oyster Creek NRC Projet Manager Administrator, Region i 9503230068 950316

^

Senior Resideat inspector

{DR ADDCK 0500 9

l GPU Nuclear Corporation is a subsidiary of General Public Utilities :.:orporation l

'