ML20076H345

From kanterella
Jump to navigation Jump to search

Forwards Ga Co Repts 906505,906577 & GA-A16829 Describing Results of Exams on Fuel Elements W/Cracked Webs.Repts Convey Belief That Cracks in Fuel Block Graphite Webbing Do Not Intersect Fuel Holes
ML20076H345
Person / Time
Site: Fort Saint Vrain 
Issue date: 06/02/1983
From: Brey H
PUBLIC SERVICE CO. OF COLORADO
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20076H347 List:
References
P-83169, TAC-57625, NUDOCS 8306160541
Download: ML20076H345 (1)


Text

.-.

y r

fP Cderado public Service Company C

2420 W. 26th Avenue, Suite 1000, Denver, Coldrado 80211 June 2, 1983 Fort St. Vrain 6 /,

g.7 Unit No. 1 P-83196 Mr. John T. Collins Regional Administrator U. S. Nuclear Regulatory Commission JE - 91983 Region IV 611 Ryan Plaza Drive, Suite 1000 W

Arlington, TX 76011

SUBJECT:

Transmittal of Nondestructive Fuel and Reflector Examination Reports GA-A16829, 906505, 906577

Dear Mr. Collins:

In order to keep you apprised of the results of examinations to date on the fuel elements with cracked webs, PSC is transmitting 40 copies

'1 of each of the following reports:

1)

GA-A16829,

" Nondestructive Examination of 54 Fuel and Reflector Elements from Fort St.

Vrain Core Segment 2",

October 1982.

2)

GA report 906505,

" Nondestructive Examination of FSV Fuel Element 1-2415", May 17, 1982.

3)

GA report 906577, " Visual Examination Results of Segment 2 FSV Fuel Elements 1-2415, 1-0172, 2-2693, 1-018 and 5-0801",

October 7, 1982.

These reports convey the belief that the cracks in the fuel block graphite webbing do not intersect fuel holes.

However, upon destructive examination of block 1-2415 at GA Technologies Inc., the crack path was found to partially intersect a fuel hole.

The report i

on this DOE-funded destructive examination will be transmitted to NRC as soon as it is available.

If PSC can be of further assistance, or if you have any questions regarding this matter, please let us know.

Very truly yours, YMwL ]

9 H. L. Brey, Manager i

Nuclear Engineering Division HLB /SH:pa cc: Mr. Robert Clark, Operating Reactor Branch, NRC w/2 copies enclosures

[

8306160541 830602 PDR ADOCK 05000267 t

P PDR t