Text

_ _ _ _ _ _ _ _ _ _ _

ATTACHMENT 1 NORTHERN STATES POWER COMPANY MONTICELLO NUCLEAR GENERATING PLANT License No. DPR-22 I

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 Supplemental Information

1. Regulatory Limits - Quarterly levels requiring reporting to Nuclear Regulatory Commission A.

Noble Gases :

5 mrad / quarter gamma radiation 10 mrad / quarter beta radiation B.

Long Lived Iodines, Particulates, and Tritium :

7.5 mrem / quarter dose to any organ C.

Liquid Effluents :

1.5 mrem / quarter dose to the total body 5.0 mrem / quarter dose to any organ

2. Maximum Permissible Concentrations A.

Noble Gases :

10 CFR Part 20, Appendix B,

Table II, Column 1 B.

Long Lived Iodines, Particulates, and Tritium :

10 CFR Part 20, Appendix B, Table II, Column 1 C.

Liquid Effluents :

10 CFR Part 20, Appendix B, Table II, Column 2 2.0 E-4 uci/ml for dissul-red and entrained gases

3. Average Energy (Not Applicable) 9409080219 940829 PDR ADOCK 05000263 R

PDR L

Page 2

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 Supplemental Information (continued)

4. Measurements and Approximations of Total Radioactivty A.

Noble Gases :

Continuous gross activity monitors in Reactor Building Vent and Plant Stack exhaust streams.

Weekly isotopic analysis of exhaust streams.

B.

Iodines in Gaseous Effluent :

Continuous monitoring with charcoal cartridges in Reactor Building Vent and Plant Stack exhaust streams with weekly analysis.

C.

Particulates in Gaseous Effluent :

Continuous monitoring with particulate filters in Reactor Building vent and Plant Stack exhaust streams with weekly analysis.

D.

Tritium in Gaseous Effluent :

Continous monitoring with silica gel cartridges in Reactor Building vent and Plant Stack exhaust streams with weekly analysis.

E.

Liquid Effluents :

Tank sample analyzed prior to each planned release and continuous monitoring of gross activity during planned release.

5. Batch Releases A.

Liquid :

1. Number of Batch Releases 0
2. Total Time Period for Batch Releases 0.0 min
3. Maximum Time Period for a Batch Release 0.0 min
4. Average Time Period for a Batch Release 0.0 min
5. Minimum Time Period for a Batch Release 0.0 min
6. Average River Flow During Release 0.0 cf/sec B.

Gaseous :

1. Number of Batch Releases 4
2. Total Time Period for Batch Releases 3533.0 min
3. Maximum Time Period for a Batch Release 1462.0 min
4. Average Time Period for a Batch Release 883.3 min
5. Minimum Time Period for a Batch Release 320.0 min

Page 3

i EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 Supplemental Information (continued)

6. Abnormal Releases A.

Liquid :

1.

Number of Releases 0

2. Total Activity Released 0.0 Ci B.

Gaseous :

1. Number of Releases 1

2.

Total Activity Released 0.3 Ci

+

Page 4

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 Table 1A Gaseous Effluents - Summation of all Releases l

l Units 1st Qtr 2nd Qtr Est. Total l

l Error, %

A.

Fission & Activation gases l

1.

Total Release Ci 1.65E+02 1.75E+02 2.00E+01 l

{

2. Average Release Rate uci/sec 2.12E+01 2.22E+01 l

3.

Percent Tech Spec Qtrly l

Reporting Level l

Gamma Radiation 9.36E-02 1.69E-01 l

Beta Radiation l

3.66E-02 1 5.83E-02 B.

Iodines l

1.

Total 1-131 Release Ci 2.04E-03 3.13E-03 1.00E+01 l l

2. Average I-131 Release Rate uci/sec 2.62E-04 3.98E-04 C.

Particulates

1. Total Particulates Ci 6.89E-04 6.61E-04 3.00E+01 l
2. Average Release Rate uci/sec 8.86E-05 8.41E-05 l

3.

Gross Alpha Radioactivity Ci 2.71E-06 8.47E-06 D.

Tritium l

1.

Total Release Ci 1.25E+01 2.54E+01 1.00E+01 l l

2.

Average Release Rate uci/sec 1.61E+00 3.23E+00 E.

Percent Qtrly Tech Spec Reporting Levels l

1.

Iodines, Particulates, l

l l

l l

and Tritium l

I 3.83E-01 l 4.41E-01 l l

l I

Page 5

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 Table 1B Gaseous Effluents - Elevated Releases l

l l

Continuous Mode l

Batch Mode l

l Nuclides Released l Unit l 1st Otr l 2nd Otr l 1st Otr l 2nd Otr l

1.

Fission Gases l

KR-85M Ci 4.95E-01 1.47E+00 0.00E+00 0.00E+00 l

KR-87 Ci 1.64E+00 3.17E+00 0.00E+00 0.00E+00 KR-88 Ci 1.46E+00 3.93E+00 0.00E+00 0.00E+00 KR-89 Ci 2.47E+00 0.00E+00 0.00E+00 0.00E+00 XE-133 Ci 3.38E+01 3.64E+01 0.00E+00 1.83E-02 XE-133M Ci 5.53E-01 4.35E-01 0.00E+00 0.00E+00 l

XE-135 Ci 9.40E+00 1.59E+01 0.00E+00 4.87E-03 l l

XE-135M Ci 1.29E+01 9.24E+00 0.00E+00 0.00E+00 l l

XE-137 Ci 6.09E+01 5.62E+01 0.00E+00 0.00E+00 l l

XE-138 Ci 3.32E+01 2.55E+01 0.00E+00 0.00E+00 l l

AR-41 Ci 2.74E-02 1.76E-01 0.00E+00 1.08E-03 l l

l l

Total for Period Ci 1.57E+02 1.52E+02 0.00E+00 2.43E-02 l 2.

Iodines l

I-131 Ci 2.94E-04 1.37E-03 0.00E+00 3.56E-08 l l

I-133 Ci 1.73E-03 8.12E-03 0.00E+00 0.00E+06-l I-135 Ci 2.46E-03 4.72E-03 0.00E+00 0.00E+00 l

l Total for Period Ci 4.49E-03 1.42E-02 0.00E+00 3.56E-08 3.

Particulates l

MN-54 Ci 0.00E+00 5.51E-07 0.00E+00 0.00E+00 l l

CO-58 Ci 0.00E+00 9.62E-08 0.00E+00 0.00E+00 l l

CO-60 Ci 2.90E-06 6.33E-06 0.00E+00 0.00E+00 l

ZN-65 Ci 5.29E-07 7.78E-06 0.00E+00 0.00E+00 l

CS-137 Ci 2.06E-06 3.28E-06 0.00E+00 0.00E+00 l

BA-140 Ci 2.57E-04 2.09E-04 0.00E+00 0.00E+00 l

SR-89 Ci 3.69E-05 9.46E-05 0.00E+00 0.00E+00 l

SR-90 Ci 2.24E-07 4.22E-07 0.00E+00 0.00E+00 I

l Total for Period Ci 2.99E-04 3.22E-04 0.00E+00 0.00E+00 i

Page 6

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 Table 1C Gaseous Effluents - Building Vent Releases l

l l

Continuous Mode l

Batch Mode l

l Nuclides Released l Unit l 1st Qtr l 2nd Qtr l 1st Qtr l 2nd Qtr l

1.

Fission Gases l

XE-133 l

Ci 0.00E+00 0.00E+00 0.00E+00 3.96E-02 l l

XE-135 Ci 7.07E+00 1.43E+01 0.00E+00 5.67E-02 l l

XE-135M Ci 9.50E-01 7.80E+00 0.00E+00 7.69E-03 l l

AR-41 Ci 0.00E+00 0.00E+00 0.00E+00 2.13E-02 l l

l l

Total for Period Ci 8.02E+00 2.21E+01 0.00E+00 1.25E-01 l 2.

Iodines l

I-131 Ci 1.74E-03 1.75E-03 0.00E+00 8.82E-07 l l

I-133 Ci 1.57E-02 1.40E-02 0.00E+00 0.00E+00 l l

I-135 Ci 2.71E-02 2.33E-02 0.00E+00 0.00E+00 l l

l l

Total for Period Ci 4.45E-02 3.90E-02 0.00E+00 8.82E-07 l 3.

Particulates l

MN-54 Ci 6.20E-06 3.52E-06 0.00E+00 0.00E+00 l l

CO-60 Ci

39E-04 1.28E-04 0.00E+00 9.58E-06 l ZN-65 Ci

'1.12E-04 1.04E-04 0.00E+00 0.00E+00 l CS-137 Ci 2.83E-05 2.84E-05 0.00E+00 0.00E+00 l

)

BA-140 Ci 1.12E-04 5.07E-05 0.00E+00 0.00E+00 l l

SR-89 Ci 1.97E-06 1.43E-05 0.00E+00 0.00E+00 l l

l Total for Period Ci 3.90E-04 3.29E-04 0.00E+00 9.58E-06 l

\\

1 a

Page 7

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 Table 2A Liquid Effluents - Summation of all Releases l

Units l 1st Qtr 2nd Qtr lEst. Total l l

l l Error, % l A.

Fission & Activation products l

1. Total Release (not including l l

l l

tritium, gases, alpha)

Ci 0.00E+00 0.00E+00 0.00E+00 l l

2. Avg Diluted Concentration uci/ml 0.00E+00 0.00E+00 B.

Tritium l

1.

Total Release Ci 0.00E+00 0.00E+00 0.00E+00 l l

2. Avg Diluted Concentration uci/ml 0.00E+00 0.00E+00 C.

Dissolved and Entrained Gases l

1.

Total Release Ci 0.00E+00 0.00E+00 0.00E+00 l l

2. Avg Diluted Concentration

.ucl/ml 0.00E+00 0.00E+00 D.

Percent Qtrly Tech Spec Reporting Level l

1. Whole Body Dose 0.00E+00 0.00E+00 l

2.

Organ Dose 0.00E+00 0.00E+00 E.

Gross Alpha Radioactivity l

1.

Total Release l

Ci l 0.00E+00 l 0.00E+00 l 0.00E+00~l lF. Volume of Waste Released l

Liters { 0.00E+00 l 0.00E+00 l 0.00E+00 l lF. Volume of Dilution Water Used l Liters l 0.00E+00 l 0.00E+00 l 0.00E+00 l Table 2B Liquid Effluents l

l Continuous Mode l

Batch Mode l Nuclides Released Unit l 1st Qtr l 2nd Otr l 1st Qtr 1 2nd Qtr None Released This Period

Page 8

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 Table 3 Solid Waste and Irradiated Fuel Shipments A.

Solid Waste Shipped Offsite for Burial or Disposal (not irradiated fuel) l 1.

Type of Waste Units l

6-month Est. Total l l

Period Error, % l l

a.

Spent resins, filter sludges, Cu. Meter 1.85E+01 l

l evaporator bottoms, etc.

Ci 1.40E+03 3.70E+01 l l

b.

Dry compressible waste, Cu. Meter 1.05E+01 l

l contaminated equipment, etc.

Ci 4.21E-01 3.50E+01 l l

c. Irradiat'ed components, Cu. Meter 0.00E+00 l

l control rods, etc.

Ci 0.00E+00 0.00E+00 l l

d. Other (describe)

Cu. Meter 0.00E+00 l

l l

Ci 1 0.00E+00 l 0.00E+00 l l

2.

Estimate of major nuclide composition (by type of waste) l l

Type A l

Type B Type C Type D l

l Nuclide percent percent percent percent l l

H-3 1.48E-02 2.48E-01 l

l C-14 l 1.10E-02 4.59E-02 l

l l

Cr-51 l 1.04E+00 l l

l Mn-54 l 3.12E+00 l 5.29E+00 l

l Fe-55 l 1.32E+00 l 4.83E+01 l

l l

Co-57 l 1.30E-02 l l

l l

Co-58 l 3.84E-01 l 7.07E-01 l

l l

Fe-59 l 1.89E-01 l 1.85E+00 l

l l

Ni-59 l 7.96E-03 l l

l l

Co-60 l 1.20E+01 l 2.04E+01 l

l l

Ni-63 l 1.47E-02 l 3.96E+00 l l

l l

Zn-65 l 7.69E+01 l 1.79E+01 l l

l l

Sr-89 l 4.85E-02 l 3.58E-02 l l

l l

Sr-90 l 4.92E-03 l 2.97E-02 l l

l l

Nb-94 l 1.40E-04 l l

l l

l Nb-95 l 1.89E-01 l l

l l

l Zr-95 l 2.98E-01 l l

l l

l Tr-99 l 9.38E-05 l 2.41E-05 l l

l l

Ru-103 l 1.55E-01 l l

l l

l Ru-106 l 1.37E+00 l l

l l

l Cd-109 l 3.63E-01 l

l l

l Ag110m l 6.87E-02 l

l Sb-124 l 1.89E-02 l

l Sb-125 l 8.11E-02 l

l l

I-129 l 1.57E-04 1.09E-04 l l

l I-131 1 3.45E-01 l

l l

Cs-134 l 4.67E-01 7.44E-02 l l

l Cs-137 l 8.16E-01 l 4.94E-01 l l

l l

Ba-140 l 3.86E-01 l l

l l

l La-140

. l 3.86E-01 l l

l l

Ce-141 l 8.71E-03 l l

l l

Ce-144 l 6.87E-03 l 6.64E-02 l

l Eu-154 l 1.71E-04 l l

l Eu-155 l 2.62E-04 l l

l l

Np-237 l 6.61E-06 l l

l l

Pu-238 l 2.23E-04 l 2.43E-01 l l

l Pu-239 l 8.67E-05 l 1.20E-01 l l

l l

Am-241 l 2.70E-04 l 2.88E-02 l l

l Pu-241 1 1.91E-02 l 6.49E-02 l l

l Cm-242 l 1.30E-03 l 4.39E-02 l

l Pu-242 l 4.13E-05 l 1.93E-01 l

l Cm-243 l 2.29E-04 l 8.69E-03 l l

l l

l I

l I

l

Page 9

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Period : Jan - Jun 1994 i

Table 3 Solid Waste and Irradiated Fuel Shipments 3.

Solid waste disposal l Number of l Mode of Destination l

Shipments Transportation 6

Truck Chem-Nuc Inc., Barnwell, SC.

I I

3.

Irradiated Fuel Shipments l

l

1. Disposition ll Number of l Mode of l

Destination l Shipments l Transportation l None This Period C. Shipping Container and Solidification Method j

No.

l Volume l Activity l Type of l Container Solidification l

M3 Ci Waste Code Code l 94-13 3.41E+00 8.03E+02 A

B D

l 94-15 l 3.41E+00 1 4.91E+02 l A

B D

94-17 l 5.83E+00 l 6.17E+01 l A

A D

94-18 l 5.83E+00 l 4.41E+01 l A.

A D

l l 94-10 l 9.10E+00 l 3.91E-01 l B

L N

I l 93-79 1.43E+00 l 2.99E-02 l B

L N

l I l l

1 l

l Container Codes :

Solidification Codes :

l L - LSA C - Cement A-Type A U - Urea Formaldehyde l

B - Type B D - Dewatering l

0 - Large Quantity N - Not Applicalble i

l I

l l

l l