Fcrm NEL 006 Rsc Approvat: Ms48 1
Procedure for Changing Filters in the Water Domineralizer Circuit 1.
Change prefilter when flow drops below 2 gpm with pump throttled.
2.
Change postfilter if flow does not increase to 3 gpm after changing prefilter.
3.
Turn off pump.
4.
Close pre-lon and fill valve and pre-lon valve.
5.
Have bucket available to catch spill.
6.
Check filters and domineralizer with gamma survey meter. Survey domineralizer-6" from top of tank. Treat filters as contaminated radioactive waste until determined otherwise.
Pre filter mR/hr Post filter mR/hr Demineralizer mR/hr
'7.
Loosen plastic jar with strap wrench.
8.
Remove plastic jar and place in bucket to dry.
Replace new filter i
9.
Admit as little air as(25 micron prefilter,125 micron post filter).
possible by filling the jar with water, f,..
- 10. Screw jar and filter back on handtight.
11, Turn on pump open pre lon and fill valve open pre lon valve. Check for leaks.
' 12. Check and record flow rate, gpm
- 13. After filter has dried, count filter on the Nai detector. Are any visible
- Gamma ray peaks present in spectrum?
YES NO~
Give source and ap:>roximate activi if YES:
- pCl If activity is greater chan pCl, treat filters as radioactive raste.
14 Operator performing procedure.
- 15. Date completed.
Form approved by Reactor Safety Committee:
' Reactor Administrator:[db
/
Date: May 25.1988