CIMARRON CORP.
(UNIT)
INTERNAL CORRESPONDENCE E. T. Still TO FROMJ.L. Kegin January 25, 1994 DATE su~ECT Burial Ground & Sanitary Lagoons Backfill Survey Data The attached documentation, for the Burial Ground and the Sanitary Lagoons, is support data to comply with condition 22.a of Amendment No. 9 to Cimarron Corp. Material License SNM-928 dated. December 28, 1992.
Supplied in this document you will find the data to support a walkover survey of both areas on a 10 meter x 10 meter grid.
Micro-R/Hr reading were taken and documented for both surface and one ( 1) meter above surface. Also on the 10 x 10 meter grid a computer data grid was selected to provide a thirty(30) percent random sampling of surface to six(6) inches depth.
This data is supplied for both uranium and thorium in both areas.
Samples of soil to be used for backfill was sent to Core Laboratories, Inc. in Casper, WY for Isotopic Analysis.
The Analytical Report is attached which should complete the data requested.
This information will also be the data for our final survey results.
copy:
R.R. Smith
CIMARRON CORPORATION CIMARRON FACILITY BURIAL GROUND RANDOM SURFACE SAMPLING OF BACKFILLED AREA AUGUST 1993 0-6 11 SURFACE SAMPLE LOCATION PCI/GRAM U PCI/GRAM TH LOCATION 10E-20N 10.63 1.32 50E-10N 10E-50N 3.9 0.81 50E-50N 10E-70N 12.48 0.71 50E-80N 20E-20N 10.24 0.79 50E-100N 20E-30N 8.44 1 60E-40N 20E-90N 8.74 0.69 60E-70N 30E-20N 7.25 0.79 60E-90N 30E-60N 9.39 0.95 70E-10N 30E-80N 10.68 0.57 70E-20N 30E-100N 8
0.84 70E-60N 40E-40N 5.63 1.08 80E-50N 40E-80N 7.54 0.9 SOE-SON 40E-90N 6.55 0.71 SOE-1 OON 40E-120N 9.87 0.7 COMPOSIT Thorium background of 1.5 pCi/gram not subtracted Uranium background of 6 pCi/gram not subtracted 0-6 11 SURFACE SAMPLE PCI/GRAM U PCI/GRAM TH 10.03 0.93 6.48 0.78 2.45 1.53 12.76 0.75 8.54 1.09 11.08 0.82 6.85 0.65 4.47 1.06 9.97 0.5 6.83 0.29 5.29 0.93 10.27 1.45 8.74 1.09 7.27 0.65
- CIMARRON CORPORATION CIMARRON FACILITY BURIAL GROUND WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA - 10 METER X 10 METER GRID DATE: AUGUST 11, 1993 & September 28, 1993 3"DET MICRO-A/HR MICRO-A/HR 3"DET MICRO-A/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER ON-OE 9880 8
8 ON-10E 8020 7
10N-OE 9190 8
7 10N-10E 8620 7
20N-OE 9540 9
8 20N-10E 8910 7
30N-OE 9820 8
8 30N-10E 8220 8
40N-OE 8940 8
7 40N-10E 7180 7
SON-OE 8990 7
7 50N-10E 9400 8
60N-OE 10030 8
8 60N-10E 9170 8
70N-OE 9110 8
7 70N-10E 8350 8
SON-OE 10010 8
8 80N-10E 9060 8
SON-OE 10270 9
9 90N-10E 9140 7
100N-OE 8750 7
8 100N-10E 9210 8
110N-OE 9460 7
8 110N-10E 8710 8
120N-OE 8640 8
8 120N-10E 8130 8
U 130N-OE 8310 8
7 130N-10E 7760 7
INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2:' Nal DETECTOR, UNSHIELDED BACKGROUND OF 7800 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E Bkg @ 1 M 6 @ Suriace 6 Highway Rightaway Marker #'2V'/ Bkg @ 1 M 8 @ Surface 7 South Enviromental Sampler 8kg @ 1 M 8 @ Surf ace 8 MICRO-A/HR
@SURFACE 8
7 8
8 6
8 7
8 7
8 9
8 7
7
CIMARRON CORPORATION CIMARRON FACILITY BURIAL GROUND WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA-10 METER X 10 METER GRID DATE: AUGUST 11, 1993 & 9-28-93 3"DET MICRO-A/HR MICRO-A/HR 3"DET MICRO-A/HR LOCATION CPM
@1 METER
@SURFACE LOCATION CPM
@ 1 METER ON-20E 6880 6
6 ON-30E 7550 6
10N-20E 7570 6
6 10N-30E 8220 7
20N-20E 9030 7
7 20N-30E 8160 7
30N-20E 7880 8
8 30N-30E 8450 7
40N-20E 7330 6
6 40N-30E 6250 7
50N-20E 8690 6
6 50N-30E 7720 7
60N-20E 8740 8
8 60N-30E 8200 6
70N-20E 9100 8
7 70N-30E 8770 6
80N-20E 8050 8
8 80N-30E 8220 7
90N-20E 9170 6
7 90N-30E 7710 7
100N-20E 9760 8
8 100N-30E 9020 7
'10N-20E 8990 8
7 110N-30E 9060 7
r 120N-20E 8020 7
7 120N-30E 8530 6
7150 7
8 130N-30E 7500 8
130N-20E INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2" Nal DETECTOR, UNSHIELDED BACKGROUND OF 7800 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E Bkg @ 1 M 6 @ Surface 6 Highway Rightaway Marker #2W Bkg @ 1 M 8 @ Surface 7 South Enviromental Sampler Bkg @ 1 M 8 @ Surf ace 8 MICRO-A/HR
@SURFACE 6
6 7
7 7
7 7
6 6
7 7
6 8
7
CIMARRON CORPORATION CIMARRON FACILITY BURIAL GROUND WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA-10 METER X 10 METER GRID DATE: AUGUST 11, 1993 & 9-28-93 3"DET MICRO-A/HR MICRO-A/HR 3"DET MICRO-A/HR LOCATION CPM
@1 METER
@SURFACE LOCATION CPM
@ 1 METER ON-40E 8290 7
6 ON-SOE 8860 7
10N-40E 8590 7
8 10N-50E 8060 6
20N-40E 8610 7
7 20N-50E 8240 8
30N-40E 8580 7
6 30N-50E 8720 7
40N-40E 7950 8
8 40N-50E 8590 7
50N-40E 8230 7
8 50N-50E 8070 8
60N-40E 8220 8
7 60N-50E 8270 8
70N-40E 8040 7
8 70N-50E 7850 8
80N-40E 7870 7
7 80N-50E 7700 7
90N-40E 8060 7
8 90N-50E 8250 7
100N-40E 8860 7
7 100N-50E 8230 8
110N-40E 8690 8
8 110N-50E 9460 7
120N-40E 8660 8
7 120N-50E 8990 8
130N-40E 8200 8
8 130N-50E 8280 7
INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2" Nal DETECTOR, UNSHIELDED BACKGROUND OF 7800 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E Bkg @ 1 M 6 @ Surface 6 Highway Rightaway Marker #2W Bkg @ 1 M 8 @ Surface 7 South Enviromental Sampler Bkg @ 1 M 8 @ Surface 8 MICRO-A/HR
@SURFACE 6
7 8
8 8
7 8
8 7
8 7
8 7
8
CIMARRON CORPORATION CIMARRON FACILITY BURIAL GROUND WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA* 10 METER X 10 METER GRID DATE: AUGUST 11, 1993 & SEPTEMBER 28, 1993 3"DET MICRO-A/HR MICRO-A/HR 3"DET MICRO-A/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER ON-60E 8310 8
7 ON-70E 8070 6
10N-60E 8690 7
7 10N-70E 8930 6
20N-60E 8780 7
6 20N-70E 8340 7
30N-60E 9180 8
8 30N-70E 7470 7
40N-60E 8420 6
7 40N-70E 7860 6
50N-60E 8330 7
8 50N-70E 8170 7
60N-60E 8470 8
8 60N-70E 8140 7
70N-60E 9210 7
8 70N-70E 8210 8
80N-60E 8490 8
7 80N-70E 8670 7
90N-60E 8540 8
9 90N-70E 8170 7
100N-60E 8720 8
7 100N-70E 8390 7
110N-60E 7490 7
7 110N-70E 8400 7
120N-60E 8760 8
8 120N-70E 7630 7
Ii 130N-60E 8290 8
7 130N-70E 7870 8
INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/Z' Nal DETECTOR, UNSHIELDED BACKGROUND OF 7800 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF 8 MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker # 1 E Bkg @ 1 M 6 @ Surface 6 Highway Rightaway Marker #2W Bkg @ 1 M 8 @ Surface 7 MICRO-A/HR
@SURFACE 7
7 8
6 6
7 7
7 7
8 8
8 8
8
- CIMARRON CORPORATION CIMARRON FACILITY BURIAL GROUND WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA-10 METER X 10 METER GRID DATE: AUGUST 11, 1993 & SEPTEMBER 28, 1993 3"DET MICRO-A/HA MICRO-A/HA 3"DET MICRO-A/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER ON-SOE 8930 7
7 10N-80E 7820 7
8 20N-80E 7870 7
7 30N-80E 7970 7
7 40N-80E 8030 6
7 50N-80E 8800 6
7 60N-80E 9040 7
8 70N-80E 8190 7
8 SON-SOE 9310 8
8 90N-80E 8370 7
7 100N-80E 8590 8
9 110N-80E 8600 8
7
,20N-80E 9230 7
8 ii 130N-80E n7o 8
8 INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3 11 X 1/2" Nal DETECTOR, UNSHIELDED BACKGROUND OF 7800 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HA NOT SUBTRACTED SITE BACKGROUND READINGS Highway Aightaway Marker #1 E Bkg @ 1M 6 @ Surface 6 Highway Rightaway Marker #2W Bkg @ 1 M 8 @ Surface 7 South Enviromental Sampler Bkg @ 1 M 8 @ Surf ace 8 MICRO-A/HA
@SURFACE
-...L ct:: --
~
~-
~
I
.. L-J..
I
)....
~
-<::l UL
~
~
~
~
~
~
- s Ct)
~
~
~
~
\\1J
-<Q
~
<...)
~
~
<..)
~
li:.
a:
~
<:)
~ -
~
1>-
-I lit 0
r=-
~
Co
~
~
c;x:::
tu
- t:
~
~. ~-
u 0 V) ~t I
. UJ Ui-I
~ I <
X 0
..s
@c§: -~
\\lt
)<
~
~
!It. "' '.
~
~ ' "
\\u 0
- r-
,. Ill.
~...
~,
~
<) -
I I
I I
I I
I cr:=_L-t~~+~-t---t-t-,-t-+--+-+-+-1-t--t-r1-:--r-!---t:--+-----l--t--t--
/
\\
CIMARRON CORPORATION CIMARRON FACILITY EAST & WEST SANITARY LAGOONS RANDOM SURFACE SAMPLING OF BACKFILLED AREA AUGUST 1993 0-611 SURFACE SAMPLE LOCATION PCI/GRAM U PCI/GRAM TH LOCATION 120E-250N 10.34 0.73 170E-250N 120E-260N 10.57 1.54 170E-260N 130E-230N 19.62 0.94 180E-210N 130E-240N 6.39 0.95 180E-230N.
130E-270N 7.94 1.01 180E-260N 140E-240N 7.12 0.41 190E-230N 140E-260N 7.16 0.6 190E-250N 140E-270N 4.42 0.76 210E-200N 150E-220N 10.87 1.4 210E-250N 150E-250N 4.34 1.29 220E-190N 150E-280N 8.87 0.59 220E-230N 160E-250N 10.7 0.98 230E-200N 170E-230N 3.59 1.51 240E-230N Thorium background of 1.5 pCi/gram not subtracted Uranium background of 6 pCi/gram not subtracted 0-611 SURFACE SAMPLE PCI/GRAM U PCI/GRAM TH 5.76 0.95 6.49 0.7 6.16 0.61 10.21 0.83 3.72 1.22 2.7 1.36 6.63 0.72 8.55 0.74 10.27 1.24 5.08 0.61 8.65 1.13 2.91 0.81 3.11 1.04
CIMARRON CORPORATION CIMARRON FACILITY SANITARY LAGOONS WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA-10 METER X 10 METER GRID AUGUST 12, 1993 & SEPT. 29, 1993 3"DET MICRO-A/HR MICRO-A/HR 3"0ET MICRO-A/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER 200N-110E 8810 6
7 200N-120E 8610 7
21 ON-11 OE 9300 8
8 210N-120E 8060 7
220N-110E 8300 7
8 220N-120E 7220 7
230N-110E 9790 8
7 230N-120E 8670 7
240N-110E 9070 7
7 240N-120E 9190 7
250N-110E 8950 7
8 250N-120E 9100 7
260N-110E 10070 7
8 260N-120E 10060 a
270N-110E 9860 7
7 270N-120E 8620 8
8 280N-120E 9440 9
290N-110E 10500 8
9 290N-120E 9860 8
300N-110E 10850 8
9 300N-120E 9850 9
INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2" Nal DETECTOR, UNSHIELDED BACKGROUND OF 7720 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E Bkg.@ 1 M 6@ Suriace 6 Highway Rightaway Marker #2W 8kg. @ 1 M 8@ Suriace 7 South Enviromental Sampler 8kg. @ 1 M 8 @ Surtace 8 MICRO-A/HR
@SURFACE 7
6 7
8 8
8 a
9 8
8 8
CIMARRON CORPORATION CIMARRON FACILITY SANITARY LAGOONS WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA - 10 METER X 10 METER GRID AUGUST 12, 1993, & SEPT. 29, 1993 3"DET MICRO-A/HR MICRO-A/HR 3"DET MICRO-A/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER 200N-130E 8730 7
7 200N-140E 9130 7
210N-130E 8180 8
7 210N-140E 8890 7
220N-130E 8210 6
7 220N-140E 9000 7
230N-130E 8590 7
7 230N-140E 9130 8
240N-130E 8380 7
6 240N-140E 8860 7
250N-130E 8560 7
7 250N-140E 9940 8
260N-130E 9800 8
8 260N-140E 8660 8
270N-130E 9220 8
7 270N-140E 9130 8
280N-130E 9010 7
8 280N-140E 9350 8
290N-130E 9610 9
8 290N-140E 10190 9
300N-130E 8490 8
8 300N-140E 9600 7
. INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2" Nal DETECTOR, UNSHIELDED BACKGROUND OF 7720 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E Bkg. @ 1 M 6 @ Suriace 6 Highway Rightaway Marker #2W Bkg.@ 1 M 8@ Surface 7 South Enviromental Sampler Bkg. @ 1 M 8 @ Surface 8 MICRO-A/HR
@SURFACE 8
7 6
6 8
7 8
7 7
9 7
CIMARRON CORPORATION CIMARRON FACILITY SANITARY LAGOONS WALKOVER GAMMA SCAN AND DOSE RATE SURVEY
(
AFTER BACKFILL OF AREA -10 METER X 10 METER GRID AUGUST 12, 1993,- SEPT.,29, 1993 3"DET MICRO-A/HR MICRO-A/HR 3"DET MICRO-A/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER 200N-150E 9120 7
7 200N-160E 9000 7
210N-150E 9830 7
8 210N-160E 9470 7
220N-150E 8810 7
7 220N-160E 8850 8
230N-150E 8670 7
8 230N-160E 9110 8
240N-150E 8750 7
7 240N-160E 8880 8
250N-150E 8520 8
8 250N-160E 8810 7
260N-150E 8730 a*
7 260N-160E 9460 7
270N-150E 9240 8
8 270N-160E 8780 8
280N-150E 9600 8
8 280N-160E 8500 8
290N-150E 8880 8
8 290N-160E 9480 8
300N-150E 10040 8
7 300N-160E 9810 9
INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2" Nal DETECTOR, UNSHIELDED BACKGROUND OF 7720 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E 8kg. @ 1 M 6@ Suriace 6 Highway Rightaway Marker #2W Bkg. @ 1 M 8@ Suriace 7.
South Enviromental Sampler Bkg. @ 1 M 8 @ Suriace 8 MICRO-A/HR
@SURFACE 7
6 7
8 8
7 8
8 8
7 8
CIMARRON CORPORATION CIMARRON FACILITY SANITARY LAGOONS WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA - 10 METER X 10 METER GRID AUGUST12, 1993,- SEPT. 29, 1993 3"DET MICRO-A/HR MIQRO-R/HR 3"DET MICRO~R/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER 200N-170E 8290 7
8 200N-180E 9010 7
210N-170E 8540 7
7 210N-180E 8900 8
220N-1"/0E 8930
- 7 7
220N-180E 8810 8
230N-170E 9060 7
8 230N-180E 8720 7
240N-170E 9200 7
7 240N-180E 8780 7
250N-170E 8710 8
8 250N-180E 9600 7
260N-170E 9560 8
8 260N-180E 10070 7
270N-170E 8970 8
8 270N-180E 9530 8
280N-170E 7810 8
8 280N-180E 8710 7
290N-170E 9590 8
7 290N-180E 9550 7
300N-170E 10330 9
8 300N-180E 8920 8
- INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2" Nat DETECTOR, UNSHIELDED BACKGROUND OF 7720 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E Bkg. @ 1 M 6 @ Surface 6 Highway Aightaway Marker #2W Bkg. @ 1 M 8 @ Surface 7 South Enviromental Sampler Bkg. @ 1 M 8 @ Surface 8 MICRO-A/HR
@SURFACE 7
7 7
7 7
9 7
7 6
7 7
CIMARRON CORPORATION CIMARRON FACILITY SANITARY LAGOONS WALKOVER GAMMA SCAN AND DOSE RATE SURVEY
(
AFTER BACKFILL OF AREA -10 METER X 10 METER GRID AUGUST 12, 1993, - SEPT. 29, 3"DET MICRO-A/HR MIC~O-R/HR 3"DET MICRO-A/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER 190N-190E 8730 7
7 180N-200E 7440 7
200N-190E 8240 7
7 190N-200E 7990 7
210N-190E 8840 8
8 200N-200E 7760 7
220N-190E 8640 7
7 210N-200E 8730 7
230N-190E 8970 8
7 220N-200E 8660 8
240N-190E 9030 7
8 230N-200E 8660 7
250N-190E 9060 8
8 240N-200E 8690 7
260N-190E 8910 7
7 250N-200E 9300 7
270N-190E 9550 7
6 260N-200E 8020 7
280N-190E 7400 7
8 270N-200E 10180 6
290N-190E 9200 7
8 280N-200E 7420 7
300N-190E 9940 7
7 290N-200E 9220 8
300N-200E 9220 7
. INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2" Nal DETECTOR, UNSHIELDED BACKGROUND OF 7720 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E Bkg. @ 1 M 6@ Surface 6 Highway Rightaway Marker #2W Bkg.@ 1 M 8@ Surface 7.
South Envirornental Sampler Bkg. @ 1 M 8 @ Surf ace 8 MICRO-A/HR
@SURFACE 8
7 8
8
.8 7
8 7
7 6
7 7
8
CIMARRON CORPORATION CIMARRON FACILITY SANITARY LAGOONS WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA-10 METER X 10 METER GRID AUGUST 12, 1993,- SEPT. 29, 1993 3"DET MICRO-A/HR Ml9RO-R/HR 3"DET MICRO-A/HR LOCATION CPM
@1 METER
@SURFACE LOCATION CPM
@ 1 METER 180N-210E 7440 6
6 180N-220E 8970 7
190N-210E 7590 7
6 190N-220E 5890 6
200N-210E 7630 6
7 200N-220E 8070 7
210N-210E 8360 7
8 210N-220E 7740 6
220N-210E 8540 8
7 220N-220E 8190 8
230N-210E 8910 7
8 230N-220E 8380 7
240N-210E 8750 8
8 240N-220E 8540 7
250N-210E 9270 8
8 250N-220E 9040 7
260N-210E 8500 8
8 260N-220E 7230 9
270N-210E 9220 7
8 270N-220E 8790 7
280N-210E 9610 8
7 280N-220E 9320 7
290N-210E 8620 7
8 290N-220E 7930 7
300N-210E 9150 8
8 300N-220E 8890 8
INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2 Nal DETECTOR, UNSHIELDED BACKGROUND OF 7720 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway. Rightaway Marker #1 E Bkg. @ 1 M 6 @ Surfa*ce 6 Highway Rightaway Marker #2W Bkg. @ 1 M 8 @ Surface 1 South Enviromental Sampler Bkg. @ 1 M 8 @ Surf ace 8 MICRO-A/HR
@SURFACE 6
6 8
7 7
8 8
7 8
8 7
7 7
CIMARRON CORPORATION CIMARRON FACILITY SANITARY LAGOONS WALKOVER GAMMA SCAN AND DOSE RATE SURVEY AFTER BACKFILL OF AREA-10 METER X 10 METER GRID AUGUST 12, 1993, - SEPT. 29, 1993 3"DET MICRO-A/HR MICRO-A/HR 3"DET MICRO-A/HR LOCATION CPM
@ 1 METER
@SURFACE LOCATION CPM
@ 1 METER 190N-230E 6230 7
7 210N-240E 6990 6
200N-230E 6270 6
7 220N-240E 7640 7
210N-230E 8160 7
7 230N-240E 8610 7
220N-230E 8810 7
7 240N-240E 8430 7
230N-230E 8850 7
7 240N-230E 8610 7
7 230N-250E 9010 8
250N-230E 8980 7
7 260N-230E 8190 7
7 270N-230E 8800 7
6 280N-230E 7450 6
6 290N-230E 7090 7
6 300N-230E 7290 7
7
. INSTRUMENTS:
LUDLUM 2221 S/N 102029, 3" X 1/2 11 Nal DETECTOR, UNSHIELDED BACKGROUND OF 7720 CPM NOT SUBTRACTED LUDLUM MICRO-A METER MODEL 19 S/N 75544 BACKGROUND OF MICRO-A/HR NOT SUBTRACTED SITE BACKGROUND READINGS Highway Rightaway Marker #1 E Bkg. @ 1 M 6 @ Suriace 6 Highway *Rightaway Marker #2W Bkg. @ 1 M 8 @ Suriace 7.
South Enviromental Sampler Bkg. @ 1 M 8 @ Suriace 8 MICRO-A/HR
@SURFACE 7
7 7
7 8
'MfiRRDN coRP.
q}.)JTfi~Y LflGooN I MJ:'rE1<. x Jo MErEI?
1R//:J
- Gft.1,u11r t 1;;osE 1ATE SLJ.:RVEY
~ - Coi1PUTEI<.
3ooN 1CkE/J SAfaPLE Po11vrs ~80 AUG/DCT 1993
~"-----I 27?>N 2.SON 2.'IDN 230N 200N 3Do 19tJN N
23t:l 22DN
/.5oE
,111, Western Atlas International Name:
Jc CORE LABORATORIES Date:
~;;),./ tkJ c: r t:'Sr Core Labor<;ltories, Inc.
420 West First Street Casper, WY 82601 The analyses, opimons or interpretations contained in this report are based upon observahOns and material supplied by the client for whose exclusive and confidential use this report has been made. The mterpreta\\1ons or opinions expressed repre-sent the best judgment of Core laboratories. Core laboratories. however. assumes no respons1b1lrty and makes no warranty or representations, express or implied, as to the productivity, proper operations. or profrtableness of any oi!, gas. coal or other mineral. property, well or sand in connectlOn with which such report 1s used or relied up.:m !or any reason whatsoever This relX)rt shall not be reproduced except 1n 11s entirety. w1!hou1 the wntten approval ol Core laboratories
.,~,,
Western Atlas International L A B O R A T O R Y CLIENT I.D *******.* : SANITARY LAGOONS COMP ioATE SAMPLED ******* : 08/30/93 TIME SAMPLED ******* :
WORK DESCRIPTION *** : SANITARY LAGOONS COMP URANIUM NATURAL TOTAL, (UNAT) 0.003 Uraniun 234, total 1.1 Uraniun 234, total, error, +/-
0.2 Uraniun 234, total, LLD 0.1 Uraniun 235, total 0.0 Uraniun 235, total, error, +/-
0.1 Uraniun 235, total, LLD 0.1
/'
m 238, total 1.1 L
..Ill 238, total, error, +/-
0.2 Uraniun 238, total, LLD 0.1 0.001 CORE LABORATORIES T E S T S 01/07/94 mg/g mg/g mg/g mg/g mg/g mg/g mg/g mg/g mg/g mg/g PAGE:1 R E S U L T S LABORATORY 1.D *** : 931711-0001 DATE RECEIVED **.* : 09/07/93 TIME RECEIVED **** : 14:30 REMARKS *****..**. : SOIL EPA 908.1 EPA 901.1 420 West First Street Casper, WY 82601 (307) 235-5741 10/28/93 12/29/93 12/29/93 12/29/93 12/29/93 12/29/93 12/29/93 12/29/93 12/29/93 12/29/93 RS RS RS RS RS RS RS RS RS RS The analyses, oplmons or interpretations contained 1n this report are based upon observations and material supplied by the chent for whose exclusive and conhdential use this report has been made. The 1nterpretat1ons or opinions expressed rapre-sent the best judgmenl of Core Laboratories. Core laboratories. however, assumes no responsibility and makes no warranty or representations. express or 1rnp!ied. as to the produchv1ty, proper operations. or profitableness ol any oil, gas, coal or olher mineral, property, well or sand in connection w11h which such report 1s used or re.lied upon !or any reason whatsoever. This report shall not be reprOOuced except 1n 1ts entirety. without the written approval of Core Laboratories
,11, Western Atlas International CLIENT I.D ********* : BURIAL GROUND COMP DATE SAMPLED.****** : 08/27/93 TIME SAMPLED ******* :
WORK DESCRIPTION *** : BURIAL GROUND COMP f t!r:i::er !w.t:~!it:i:21111::i::1111::11111:1111r 1t:::::::
URANIUM NATURAL TOTAL, (UNAT)
Uraniun 234, total Uraniun 234, total, error, +/-
Uraniun 234, total, LLD Uraniun 235, total Uraniun 235, total, error, +/-
Uraniun 235, total, LLD Ill 238, total l..
.,un 238, total, error, +/-
Uraniun 238, total, LLD L A B O R A T O R Y 0.002 5.5 1.1 0.1 1.3 0.4 0.4 3.1 0.7 0.3 0.001 CORE LABORATORIES T E S T S 01/07/94 R E S U L T S
- =v:iR*:.:.E::={/:*1.-0**:.. R.:.:J:A:\\i: f)_}_(!/ff
- ...,,... :'1-:fr*. " "'";::
- .*.*.**:*:*:*:*:*:,*,:,:*:;:;:;:;:::*::::::;:;:;:;:::,:::::::::;:::::::::::::::::*:*:***=*
LABORATORY 1.0 *** : 931711-0002 DATE RECEIVED **** : 09/07/93 TIME RECEIVED.*** : 14:30 REMARKS.********* : SOIL dN'.i.[{fef:I!~i~Yii ::::1::i::11:::1tESJ{M~*-**w* -
gif=f1
- i::::1::::: :[igQMfiM~
PAGE:2 mg/g EPA 908.1 10/28/93 RS mg/g mg/g mg/g mg/g mg/g mg/g mg/g mg/g mg/g EPA 901.1 420 West First Street Casper, WY 82601 (307) 235-5741 01/07/94 LBA 01/07/94 LBA 01/07/94 LBA 01/07/94 LBA 01/07/94 LBA 01/07/94 LBA 01/07/94 LBA 01/07/94 LBA 01/07/94 LBA The analyses. opinions or interpretations contained in lh1s report are based upon observahOns and material supphed by the client tor whose exclusive and conhdent1al use this report has been made. The mterpretat1ons or opm1ons expressed rapre-senl the best judgment ol Core laboratories. Core Laboratories. however, assumes no responsibility and makes no warranty or representations, express or implied. as to the productr,,ity, proper operations. or profitableness ol any oil, gas. coal or Olher mineral, property, welt or sand in connection wilh which such report is used or rejied upon for any reason whatsoever This report shall not be reproduced excep11n its entirety, without lhe written approval o! Core Laboratories
.,111, Western Atlas International ANALYSIS CORE LABORATORIES Q U A L I T Y C O N T R O L 01/07/94
'DUPLICATES R E P O R T REFERENCE STANDARDS MATRIX SPIKES I
ANALYSIS ANALYSIS ANALYSIS ANALYZED DUPLICATE RPD or TRUE TYPE SUB-TYPE I.D.
VALUE (A)
VALUE CB)
CIA-Bl)
VALUE PERCENT RECOVERY ORIGINAL VALUE SPIKE ADDED BLANK STANDARD SPIKE DUPLICATE BLANK BLANK STANDARD STANDARD DUPLICATE
'b.
DUPLICATE BLANK BLANK STANDARD STANDARD DUPLICATE BLANK BLANK STANDARD STANDARD SPIKE DUPLICATE BLANK BLANK DUPLICATE MB LCS MS MD MB MB LCS LCS MB MB MB MD MB MB LCS LCS MD MB MB LCS LCS MS MD MB MB MD MB3UN1028 LC3UN1028 931903-1 931879-2 MB1U1216 MB2U1216 ST1U1216 LC1U1216 931711-1 MB1U1216 MB2U1216 931711-1 MB1U1216 MB2U1216 ST1U1216 LC1U1216 931711-1 MB1U0106 MB2U0106 ST1U0106 LC1U0106 931711-2 931711-2 MB1U0106 MB2U0106 931711-2
<0.001 0.079 0.001
<0.001 0.0 0.0 5.2 5.2 1.1 0.0 0.0 0.0 0.0 0.0 3.2 5.2 1.1 0.0 0.0 6.5 7.0 10.9 5.5 0.0 0.0 1.3
<0.001 NC 1.1 0
0.0 0
1.2 9
2.9 62 0.5 89 PAGE:3 0.085 6.6 6.6 6.6 6.6 13.8 13.8 93 79 79 48 79 47 51
<0.001 2.9 420 West First Street Casper, WY 82601 (307) 235-5741 0.001 13.8 PERCENT RECOVERY 100 58 The analyses. opm1ons or interpretations contained m this report are based upon observations and material supplied by the client lor whose exclusive and confidential use this report has been made. The mterpreta!fOns or opinions expressed repre~
sent the best judgment of Core Laboratones. Core Laboratories, however. assumes no respons1b1lrty and makes no warranty or representations. express or 1rnpl1ed. as to the productivity, proper operations. or profrtableness of any 011. gas, coal or other mineral. property, well or sand 1n connection wilh which such report 1s used or relted upon for any reason whatsoever This report shall not be reproduced except in its entirety, without the written approval of Core LaOOratories
ANALYSIS TYPE BLANK BLANK STANDARD STANDARD SPIKE DUPLICATE Vil Western Atlas International ANALYSIS ANALYSIS SUB-TYPE MB MB LCS LCS MS MD ANALYSIS I.D.
MB1U0106 MB2U0106 ST1U0106 LC1U0106 931711-2 931711-2 CORE LABORATORIES QUAL TY C O N T R O L 01/07/94
- DUPLICATES ANALYZED VALUE (A) 0.0 0.0 7.3 6.7 8.9 3.1 DUPLICATE VALUE (B) 1.8 RPD or (IA-BI>
53 PAGE:4 R E P O R T REFERENCE STANDARDS MATRIX SPIKES TRUE VALUE 13.8 13.8 PERCENT RECOVERY ORIGINAL VALUE SPIKE ADDED 53 49 1.8 420 West First Street Casper, WY 82601 (307) 235-5741 13.8 PERCENT RECOVERY 51 The analyses. opinions or interpretations contained in this report are based upon observations and material supplied by the client tor whose exc!usrve and confldenlfal use this report has been made. The interpretations or opinions expressed repre-sent the best judgment ol Core Laboratories. Core laboratories. however, assumes no responsibility and makes no warranty or representations, express or implied, as to the product1Vrty, proper operations. or profrtab\\eness ol any oi!, gas, coal or other mineral, property. well or sand m connection with which such report 1s used or rehed upon tor any reason whatsoever This report shall not be reproduced except m,ts entirety, without the written approval of Core Laboratories.
,11, CORE LABORATORIES Western Atlas International Q U A L I T Y C O N T R O L 01/07/94 NC= Not Calculable due to values lower than the detection limit ND= Not detected at level in limits colUTYl F O O T E R
- in the 11TECHN 11 colUTYl signifies that the analysis was performed by a subcontract laboratory.
Analyses on soil/sediment samples are performed 11as received" (e.g., uncorrected for moisture) unless otherwise specified.
(1)
(2)
(3)
(4)
(5)
(6)
NOTE NOTE EPA 600/4-79-020, Methods for Chemical Analysis of Water and Wastes, March 1983 EPA SW-846, Test Methods for Evaluating Solid Waste, Third Edition, November 1986 Standard Methods for the Examination of Water and Wastewater, 16th, 1985 EPA/6004-80-032, Prescribed Procedures for Measurement of Radioactivity in Drinking Water, August 1980 Federal Register, Friday, October 26, 1984 (40 CFR Part 136)
EPA 600/8-78-017, Microbiological Methods for Monitoring the Environment, December 1978
- Data reported in QA report may differ from values on data page due to dilution of sample into analytical
- The "TIME ANALYZED" as indicated in the QA Report may not reflect the actual time of analysis.
The "DATE ANALYZED" is the actual date of analysis.
PAGE:5 420 West First Street Casper, WY 82601 (307) 235-5741 ranges.
The analyses, opinions or interpretahons contained in this report are based upon obseivat1ons and material supplied by lhe client for whose exclusive and conhdentral use th1s report has been made. The interpretations or opinions expressed repre-sent the best judgment of Core laboratories. Core laboratories. however, assumes no responsibility and makes no warranty or representations. express or imphed, as to lhe productivity. proµer operations. or profitableness ol any oi!, gas, coal or olher mineral. property. well or sand m connection with whteh such report 1s used or re!i.ed upon for any reason whatsoever. This report shalt not be reproduced except in its en11rety. without lhe written approval of Core laboratories.