9400 Ward Parkway

  • Kansas City, MO 64114 Tel: 405-642-5152
  • jlux@envpm.com July 3, 2024 Mr. James Smith U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2738 Ms. Rachel Miller Oklahoma Department of Environmental Quality 707 North Robinson Oklahoma City, OK 73101 Linda Gersey U.S. Nuclear Regulatory Commission, Region IV 1600 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4511 Re: Docket No. 07000925; License No. SNM-928 Cimarron Environmental Response Trust Annual Environmental Monitoring Program Data

Dear Recipients:

Solely as Trustee for the Cimarron Environmental Response Trust (CERT), Environmental Properties Management LLC (EPM) submits herein to the U. S. Nuclear Regulatory Commission (NRC) and the Oklahoma Department of Environmental Quality (DEQ) the analytical results from the 2024 Annual Environmental Monitoring Program. Samples were collected and analyzed in accordance with Section 15 of the CERT Radiation Protection Plan (RPP).

Section 15 of the RPP specifies that groundwater samples are to be collected from 29 monitor wells and surface water samples are to be collected from two locations in the Cimarron River.

Samples were collected from April 16 through April 18, 2024.

Concentrations of uranium, nitrate, or fluoride that exceed either NRC or State criteria are highlighted. It looks like there are very few locations where either nitrate or fluoride exceed State criteria; this is due to the fact that the environmental monitoring program was intended to assess the extent of licensed material in the environment. Consequently, the majority of sample locations are within areas where uranium concentrations exceed the NRC criterion, extending downgradient from those locations.

With the exception of the surface water samples, the data is tabulated by remediation area as defined in Facility Decommissioning Plan - Rev 3, and within each remediation area, locations are generally arranged in order from upgradient to downgradient locations.

9400 Ward Parkway

  • Kansas City, MO 64114 Tel: 405-642-5152
  • jlux@envpm.com If you have any questions or desire to discuss the results of the annual environmental sampling program, please call me at (405) 642-5152.

Sincerely, Jeff Lux Trustee Project Manager cc: (electronic copies only)

Stephanie Anderson, NRC Region IV Paul Davis, Keisha Cornelius, Lee Dooley, David Cates, and Jonathan Reid, DEQ NRC Public Document Room vcpsubmittals@deq.ok.gov

2024 Annual Environmental Monitoring Data

ATTACHMENT 1 2024 ANNUAL ENVIRONMENTAL MONITORING DATA

Cimarron Environmental Response Trust 2024 Annual Environmental Monitoring Data Area Sample Number Collection Date Parameter Lab Result Uncertainty Units Total Activity/

Concentration Lab or Data Review Qual MDL Fluoride 0.347 0.0249 mg/L 0.066 Nitrogen, Nitrate/Nitrite 0.017 mg/L U

0.017 Uranium-235 0.0513 0.00421 ug/L J

0.010 Uranium-238 7.15 0.358 ug/L 7.20 0.067 Fluoride 0.337 0.0247 mg/L 0.066 Nitrogen, Nitrate/Nitrite 0.017 mg/L U

0.017 Uranium-235 0.0503 0.00418 ug/L J

0.010 Uranium-238 6.89 0.345 ug/L 6.94 0.067 Fluoride 6.36 0.213 mg/L 0.066 Nitrogen, Nitrate/Nitrite 16.4 mg/L 0.850 Uranium-235 6.45 0.330 ug/L 0.200 Uranium-238 212 10.6 ug/L 218.45 1.340 Fluoride 4.39 0.147 mg/L 0.033 Nitrogen, Nitrate/Nitrite 6.06 mg/L 0.170 Uranium-235 2.81 0.144 ug/L 0.100 Uranium-238 156 7.80 ug/L 158.81 0.670 Fluoride 0.699 0.0258 mg/L 0.033 Nitrogen, Nitrate/Nitrite 45.6 mg/L 0.850 Uranium-235 0.218 0.0114 ug/L 0.010 Uranium-238 9.77 0.489 ug/L 9.99 0.067 Fluoride 0.718 0.0264 mg/L 0.033 Nitrogen, Nitrate/Nitrite 46.5 mg/L 0.850 Uranium-235 0.220 0.0115 ug/L 0.010 Uranium-238 9.94 0.498 ug/L 10.16 0.067 Fluoride 0.455 0.0187 mg/L 0.033 Nitrogen, Nitrate/Nitrite 22.3 mg/L 0.850 Uranium-235 0.166 0.00895 ug/L 0.010 Uranium-238 14.9 0.746 ug/L 15.07 0.067 1352 1351 DUP WU-BA3 04/16/24 04/18/24 MWWA-03 04/18/24 1206-NORTH 1351 04/16/24 MWWA-09 04/18/24 Surface Water 4/17/2024 1201 4/17/2024 1202 Page 1 of 5

Cimarron Environmental Response Trust 2024 Annual Environmental Monitoring Data Area Sample Number Collection Date Parameter Lab Result Uncertainty Units Total Activity/

Concentration Lab or Data Review Qual MDL Fluoride 0.518 0.0205 mg/L 0.033 Nitrogen, Nitrate/Nitrite 124 mg/L 1.700 Uranium-235 0.0183 0.00346 ug/L J

0.010 Uranium-238 2.72 0.138 ug/L 2.74 0.067 Fluoride 0.380 0.0168 mg/L 0.033 Nitrogen, Nitrate/Nitrite 9.02 mg/L 0.170 Uranium-235 3.52 0.179 ug/L 0.100 Uranium-238 201 10.0 ug/L 204.52 0.670 Fluoride 2.81 0.0942 mg/L 0.033 Nitrogen, Nitrate/Nitrite 45.4 mg/L 1.700 Uranium-235 1.74 0.0888 ug/L 0.050 Uranium-238 95.5 4.78 ug/L 97.24 0.335 Fluoride 1.32 0.0453 mg/L 0.033 Nitrogen, Nitrate/Nitrite 2.21 mg/L 0.170 Uranium-235 0.796 0.0403 ug/L 0.020 Uranium-238 22.0 1.10 ug/L 22.80 0.134 Fluoride 0.636 0.0239 mg/L 0.033 Nitrogen, Nitrate/Nitrite 4.75 mg/L 0.170 Uranium-235 1.14 0.0595 ug/L 0.050 Uranium-238 25.6 1.29 ug/L 26.74 0.335 Fluoride 2.57 0.0864 mg/L 0.033 Nitrogen, Nitrate/Nitrite 3.94 mg/L 0.170 Uranium-235 3.43 0.175 ug/L 0.100 Uranium-238 126 6.29 ug/L 129.43 0.670 Fluoride 0.626 0.0236 mg/L 0.033 Nitrogen, Nitrate/Nitrite 0.820 mg/L 0.085 Uranium-235 0.961 0.0485 ug/L 0.020 Uranium-238 29.8 1.49 ug/L 30.76 0.134 T-62 WU-BA3 T-77 04/18/24 04/18/24 T-64 04/18/24 T-70R 04/18/24 WAA U>DCGL 04/18/24 1354 04/18/24 1356 T-76 04/18/24 Page 2 of 5

Cimarron Environmental Response Trust 2024 Annual Environmental Monitoring Data Area Sample Number Collection Date Parameter Lab Result Uncertainty Units Total Activity/

Concentration Lab or Data Review Qual MDL Fluoride 0.502 0.02 mg/L 0.033 Nitrogen, Nitrate/Nitrite 0.105 mg/L 0.017 Uranium-235 0.587 0.0295 ug/L 0.010 Uranium-238 22.0 1.10 ug/L 22.59 0.067 Fluoride 0.433 0.0182 mg/L 0.033 Nitrogen, Nitrate/Nitrite 0.830 mg/L 0.085 Uranium-235 0.247 0.0128 ug/L 0.010 Uranium-238 16.2 0.810 ug/L 16.45 0.067 Uranium-235 0.01 0.00336 ug/L U

0.010 Uranium-238 1.1 0.0594 ug/L 1.11 0.067 Uranium-235 1.52 0.0777 ug/L 0.050 Uranium-238 127 6.33 ug/L 128.52 0.335 Uranium-235 2.66 0.134 ug/L J

0.050 Uranium-238 177 8.87 ug/L 179.66 J

0.335 Uranium-235 2.32 0.121 ug/L 0.100 Uranium-238 154 7.68 ug/L 156.32 0.670 Uranium-235 0.0268 0.00359 ug/L J

0.010 Uranium-238 2.91 0.147 ug/L 2.94 0.067 Uranium-235 0.173 0.00928 ug/L 0.010 Uranium-238 14.6 0.729 ug/L 14.77 0.067 Uranium-235 22 1.15 ug/L 1.000 Uranium-238 1880 94.1 ug/L 1902.00 6.700 Uranium-235 21.3 1.11 ug/L 1.000 Uranium-238 1820 90.8 ug/L 1841.30 6.700 BA1-A TRANSITION ZONE BA1A SANDSTONE B

1314 04/17/24 02W28 04/17/24 TMW-09 04/17/24 TMW-09 DUP 04/17/24 02W42 04/17/24 02W27 02W09 04/17/24 04/18/24 T-82 04/18/24 WAA-WEST T-79 WAA U>DCGL 04/17/24 TMW-08 04/17/24 Page 3 of 5

Cimarron Environmental Response Trust 2024 Annual Environmental Monitoring Data Area Sample Number Collection Date Parameter Lab Result Uncertainty Units Total Activity/

Concentration Lab or Data Review Qual MDL Uranium-235 3.59 0.182 ug/L 0.100 Uranium-238 292 14.6 ug/L 295.59 0.670 Uranium-235 1.18 0.0613 ug/L 0.050 Uranium-238 98.0 4.90 ug/L 99.18 0.335 Uranium-235 1.17 0.061 ug/L 0.050 Uranium-238 96.4 4.82 ug/L 97.57 0.335 Uranium-235 3.47 0.177 ug/L 0.010 Uranium-238 269 13.4 ug/L 272.47 0.670 Uranium-235 0.416 0.0211 ug/L 0.010 Uranium-238 35.2 1.76 ug/L 35.62 0.067 Uranium-235 3.29 0.168 ug/L 0.100 Uranium-238 254 12.7 ug/L 257.29 0.670 Uranium-235 2.38 0.123 ug/L 0.100 Uranium-238 179 8.97 ug/L 181.38 0.670 Uranium-235 0.547 0.0276 ug/L 0.010 Uranium-238 43.4 2.17 ug/L 43.95 0.067 Uranium-235 0.421 0.0213 ug/L 0.010 Uranium-238 34.0 1.70 ug/L 34.42 0.067 Uranium-235 1.20 0.0621 ug/L 0.050 Uranium-238 94.5 4.72 ug/L 95.70 0.335 02W35 04/16/24 04/17/24 02W32 02W08 04/17/24 02W16 04/17/24 04/17/24 02W32 DUP 04/17/24 02W06 BA1-B SOUTH BA1-BNORTH 04/17/24 TMW-13 04/16/24 02W44 04/16/24 02W43 04/16/24 02W17 Page 4 of 5

Cimarron Environmental Response Trust 2024 Annual Environmental Monitoring Data Area Sample Number Collection Date Parameter Lab Result Uncertainty Units Total Activity/

Concentration Lab or Data Review Qual MDL Notes:

Highlighted cells indicate results above remediation goal.

Red bold font indicates information not provided in laboratory electronic deliverable.

MDL = Method Detection Limit mg/L = milligrams per Liter ug/L = micrograms per Liter Nitrate: 22.9 mg/L Fluoride: 4 mg/L Uranium: 30 µg/L CalcultedUranium Concentration: 123 ug/L in WAA U>DCGL, 1206-NORTH, & WU-BA3 CalcultedUranium Concentration: 201 ug/L elsewhere NRC Criteria DEQ Criteria Page 5 of 5