l i

Omaha Public Power District 1623 HARNEY a OMAHA, NEBRASMA 66102 e igLEPHONE 536 4000 AREA CODE 402 March 25, 1982 LIC-82-134 co 0) i Mr. Robert A. Clark, Chief 46 4p ?3<.&pg U. S. Nuclear Regulatory Commission

~

Office of Nuclear Reactor Regulation

(

e Division of Licensing Operating Reactors Branch No. 3 9

//

Washington, D.C.

20555

Reference:

Docket No. 50-285 ru

Dear Mr. Clark:

3 to the Omaha Public Power District's letter dated August 26, 1981, concerning environmental qualification of safety-related electrical equipment, provided a list of outstanding items that the District had yet to complete to ensure Fort Calhoun Station electri-cal equipment and components are environmentally qualified.

Items 11 and 12 of the subject enclosure involve the replacement of certain harsh environment limit switches and solenoid valves in containment and the auxiliary building, respectively. The District replaced these limit switches and solenoid valves with IEEE 323-1974 qualified components during the 1981 refueling outage. Accordingly, the District submits the attached revised system component evaluation worksheets (SCEWS) which incorporate the new aualification information and replace the correspond-ing SCEWS in Enclosure 6 of the District's August 26, 1981 letter.

Please note that the attached SCEWS pages 6-1D, 6-44, and 6-59a provide new data not previously included in Enclosure 6.

The solenoids identi-fied on these pages were also replaced with IEEE 323-1974 qualified ASCO solenoids and are now included with the other SCEWS of Enclosure 6. 3 has been revised to reflect the completion of Items 11 and 12.

Items 2, 4, and 15 of Enclosure 13 have also been updated to reflect current information. The revised Enclosure 13 is attached.

Sincerely,

/M U W. C. Jones Division Manager Production Operations Attachments cc: LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, N.W.

Washington, D.C.

20036 0

8204050333 820325 PDR ADOCK 05000285 I

l g;

T PDR I jf i

-. 3 Outstanding Items 1.

The aging and qualified life maintenance program will be imple-2 mented by June 30, 1982.

2.* FT-236 was relocated from a harsh environment to a " normal room i

environment" (the corridor outside of Room 13) during the 1981 refueling outage.

3.

The Conax penetration testing will be completed by June 30, 1982.

4.

The District has completed a submergence evaluation and expects to move the following electrical equipment above the flood level in containment durine the 19E3 refueling outage:

Limit Switches and Solenoids Limit Switches Only Flow Transmitters HCV-467A HCV-238 FT-313 HCV-467C HCV-239 FT-316 HCV-438A FT-319 HCV-438C FT-322 HCV-1387A

' HCV-1388A 5.

The District plans to re-evaluate the radiation dose received by equipment just above the containment flood level.

This will be completed by June 30, 1982.

6.

In investigating the effects of chemical spray, the FSAR value of 1700 ppm boron was used.

In discussions with the plant staff, the concentration for the Safety Injection and Refueling Water Storage Tank is maintained at up to 2500 ppm boron.

The District feels l

that this will not effect the equipment; however, the question is t

being re-evaluated.

This will be completed by June 30, 1982.

7.

To ensure proper evaluation of the radiation effects in contain-ment, the District requests the NRC's concurrence on its use of the D0R guidelines to establish containment radiation doses.

8.

The District plans to do plant specific radiation calculations for Auxiliary Feedwater Valves HCV-1107A and HCV-1108A due to their proximity to the RCS.

The District plans to do plant specific calculations for VA-3A and VA-3B due to their proximity to the charcoal filters.

This will be completed by Jure 30, 1982.

9.

The bistrict will complete evaluation of FT-416, 417, 418, and 419 by June 30, 1982.

i 13-1 R7 3/25/82

_ 3 Outstanding Items (Continued)

10. The District plans to complete testing of the Fisher 304 limit switch by June. 30, 1982.

11.* The limit switches and Valcor solenoid valves in containment were replaced with environmentally qualified components during the 1981 refueling outage.

12.* The solenoid valves and limit switches in the auxiliary building

-were replaced with environmentally qualified components during the 1981 refueling outage.

13. TE 8?6 and TE 867 will be replaced during the.first refueling outage after receipt of qualified parts.

4

14. Qualified Safety Related Equipment will be identified and marked with orange in the control room and operator training will be completed by June 30, 1982.
15. Conax Corporation has verified that the concentration of boron used in the chemical concentration qualification of their Conax seals was an acceptable 3000 parts per million.

Conax Corporation has

.also confirmed in the same letter that their seals are' qualified 4

for a design life of 40 years (reference Conax letter from W. C.

i Frederick to R. F. Mehaffey (0 PPD) dated February 5,1982). The SCEWS have been revised to reflect this information and will be provided to the Commission by May 1,1982.

  • These items are complete.

i i

i l

i

Facility: Fort Calhoun 1 Docket No.: 50-285 C-52 SYSTEM COMPONENT EVALUATON k'ORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OITTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Charcoal Spray l atermittent System Time Note 1 Note 2 Note 2 2

Type Test NONE Item No.: HCV-865, 864 Tempera-ture *F

.305 F 340 F 1

2 Type Test NONE Component: Solenoid Pressure PSIg 60 psig 110 psig 1

2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP-8321A185E Humidity %

100%

100%

1 2

Type Test NONE ga Function: Remote Operation of Chemical 1700 ppm 3000 ppm Valves Spray Boron Boron PHIC 1

2 Type Test NONE g

7' Accuracy - Spec: N/A E$

Demon: N/A Radiation 3x10 R 2.04x10 R 1

2 Type Test NONE 8

8 Se rvice: See Function Location: Containment Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev:

1000.9' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A Type Test NONE Documentation

References:

Notes:

1) Enclosure #1
1) Required to operate intermittently during an accident.
2) ASCO Test Report No. AQS 21678/TR
2) Radiation is limiting, qualification shown adjusting 7
3) ASCO Letter Dated July 10, 1980 1.92x10 R for 1000 HR using D0R Guideline NoMagrams qualification is adequate.

Present Qualification:

IEEE 323-1974 4574/a-53/g

Focility: Fort Calhoun 1 Docket No.:

50-285 R1-1 SYSTEM COMPONENT EVALUATON k'ORK SifEET ENvTunwrer nommrerrrnv nvr QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation carinn entinn cation System: Chemical & Volume Control Operating Time 1000 hrs 1000 hrs Note 1 2

Tvne Test NONE Item No.: HCV-204 HCV-206 Tempera-ture *F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8320A185E Humidity 1 N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical CVCC Spray N/A N/A N/A N/A N/A NONE Accuracy - Spec: N/A 8

Demon: N/A Radiation 4x106 R 2x10 R 1

2 Type Test NONE Service: See Function Location: Room 13 Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev:

N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 17, Figure 4.2-2 (December 1979)
2) ASCO Test Report Model AQS 21678/TR g
3) ASC0' letter dated July 10, 1980 Present Qualification c3 IEEE 323-1974 l ES

Facility: Fort Calhoun 1 Docket No.: 50-285 C-52 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUI'cMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Auxiliary Feedwater System Time 1000 hrs Note 1 Note 1 2

Type Test NONE Item No.: HCV-1107A, HCV-1108A Tempera-ture 'F

.305'F 340 F 1

2 Type Test NONE Component: Solenoid Pressure PSIg 60 psig 110 psig 1

2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP-8320A175E Humidity %

100%

100%

1 2

Type Test NONE Function: Remote Operation of Chemical 1700 ppm 3900 ppm Valves Spray Boron Boron PHIC 1

2 Type Test NONE

$E Accuracy - Spec: N/A 6

8 Demon: N/A Radiation 3x10 R 2.04x10 R 1

2 Type Test NONE Service: See Function Location: Containment Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev:

1000.9' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) Enclosure #1
1) Radiation is limiting, qualification shown.Qjusting 7
2) ASCO Test Report No. AQS 21678/TR 1.92x10 R for 1000 HR using D0R Guideline NoMagrams
3) ASCO Letter Dated July 10, 1980 qualification is adequate.

Present Qualification:

IEEE 323-1974

g 4574/a-51/g

Facility: Fort Calhoun 1 Docket No.: 50-285 S-2 SYSTEM COMPONENT EVALUATON WORK SHEET revTunwrw nnmpirm7ne DEF-QUALIFI-Ob7 STAND CATION ING EQUIPMENT DESCRIPTION

.Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter carinn ratinn entinn carinn System: Component Cooling Operating Time Note 1 1000 hrs N/A

?

Type Test NOVF Item No.: HCV-2898A,B and HCV-2899A,B Tempera-ture *F 216'F 346 F 1

2 Type Test NONE Component: Solenoid Valve Pressure PSIR 1.2 psig 110 psig 1

2 Type Tesi NONE Manufacturer: ASCO Relative Model No.: NP 8320A185E Humidity % 100%

100%

1 2

Type Tes1.

NONE Function: CCW inlet and disch Chemical valves Spray N/A N/A N/A N/A N/A NONE o,

Accuracy - Spec: N/A Demon: N/A Radiatior N/A N/A N/A N/A N/A NONE Service: CCW inlet & disch vv for cont run HVAC units VA-46A, H Location: Room 81 Aging N/A 10 yrs N/A 2

Type Tesu NONE Flood Level Elev:

1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) See Enclosure #2 -
1) '7V's are required to operate only if there is a failure
2) ASCO Test Report Model AQS 21678/TR of the Component Cccling System. They function to block CCW flow and are normally open and de-energized.

Present-Qualification U5 IEEE 323-1974 t'

2; si

~

e

Facility:

Fort Calhoun 1 Docket No.:

50-285 I-26 SYSTEM COMPONENT EVALUATON WORK SHEET vwInnvMrer nnnmvvt> rnv per QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation catinn cation System: Component Cooling Operating Time 1000 hrs 1000 hrs Note 1 1

Type Test NONE Item No.: HCV-2808A, 2808B, 2810A, 2810B, 2812A, 2812B, 2813A, 2813Ii Tempera-ture *F 109'F 346'F 2

1 Type Test NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative

.Model No.: NP 8320A185E Humidity % 100%

100%

2 1

Type Test NONE Function: Valve Actuators for Chemical

{}

inlet & outlet falves for SI &

Spray N/A N/A N/A N/A N/A NONE j

Spray pumps bearing coolers.

Accuracy - Spec: N/A Demon: N/A Radiation 7x10 R 2x10sR 3

1 Type Test.

NONE 6

Service: See Function Location: Room 21 (SI pumps)

Aging N/A 10 yrs N/A 1

Type Test.

NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) ASCO Test Report Model AQS 21678/TR
1) Valves are locked open and do not operate during
2) Combustion Engineering study " Evaluation of Fort an event.

(See Enclosure #14).

Calhoun Safety Injection Pump Room Temperature following 32 a Loss of Coolant Accident.

(See OPPD letter to the NRC ated 9/6/79) i Ef

3) Implementation Methods and Schedules for NUREG-0578 jf Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)

. 00 Present Qualification IEEE 323-1974 l

I e

Facility: Fort Calhoun 1 Docket No.:

50-285 I-27 SYSTEM COMPONENT EVALUATON WORK SHEET ENVT ROUfENT TW'IMMT! TOM DFF QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation carinn catinn System: Component Cooling Operating Note 1 Time 1000 hrs 1000 hrs Note 2 3

Tyne Test NONE Item No.: HCV-2809A, 2809B, 2811A, 2811B, 2814A, 2814B, 2815A, 2815B Tempera-ture F 109 F 346 F 1

3 Type Test NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8320A185E Humidity % 100%

100%

1 3

Type Test NONE Function: Valve Actuators for Chemical os inlet & outlet Salves for SI &

Spray N/A N/A N/A N/A N/A NONE Spray pumps bearing coolers.

e)

Accuracy - Spec: N/A 6

8 Demon: N/A Radiation 7x10 R 2x10 R 2

3 Type Test.

NONE Se rvice: See Function Location: Room 22 (SI pumps)

Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev: N/A Submer-N/A N/A NONE Above Flood Level:

gence N/A N/A N/A Documentation

References:

Notes:

1) Combustion Engineering study " Evaluation of Fort
1) See Enclosure #18.

Calhoun Safety Injection Pump Room Temperature following 2) Values are locked open and do not operate during m

a Loss of Coolant Accident.

(See OPPD letter to the an event. See Enclosure #14.

NRC ated 9/6/79)

{$

2) " Implementation Methods and Schedules for NUREG-0578" c3 Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)
cg
3) ASCO Test Report Model AQS 21678/TR Present Qualification IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.:

50-285 RI-3 SYSTEM COMPONENT EVALUATON k'ORK SHEET vvvinnywrvT nnmmvvT Tnv ove QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parnmeter cation entinn entinn catinn System: Component Cooling Operating Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-467B,D HCV-438B,D Tempera-ture *F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIR N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8320A185E Humidity % N/A N/A N/A N/A N/A NONE function: Valve Actuators for Chemical Component Cooling Spray N/A N/A N/A N/A N/A NONE en1 Accuracy - Spec: N/A Demon: N/A Radiation 4x108 R 2x10 R 1

2 Type Test NONE 8

Service: See Function Location: Room 13 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) "Implemeatation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 17, Figure 4.2-2 (December 1979)
2) ASCO Test Report Model AQS 21678/TR

[3 Present Qualification IEEE 323-1974 na

, 23 5?

.E a

Facility: Fort Calhoun 1 Docket No.: 50-285 R2-1 SYSTEM COMPONENT EVALUATON WORK SHEET FNVTRONMFMT DOPPfFNT! TON RFF-QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi.-

METIIOD ITEMS Pa ra*.e t e r cation cation cation cation System: Component Cooling Operating Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-425B HCV-425D Tempera-ture *F N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical as Component Cooling Leakage Spray N/A N/A N/A N/A N/A NONE

.L l

Accuracy - Spec: N/A Demon: N/A Radiation 8x105 R 2x10sR 1

2 Type Test.

NONE Se rvice: See Function Location: Room 59 Aging N/A 10 yrs N/A 2

Type Test.

NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 18, Figure 4.2-3 (December 1979)
2) ASCO Test Report Model AQS 21678/TR
o Present Qualification If IEEE 323-1974 E;

og N

O 9

Facility: Fort Calhoun 1 Docket No.:

50-285 R4-2 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRO'efENT DOCUMENTATOM RFP-QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Speci fi-Qualifi-METHOD ITEMS Pa rameter cation cation cation cation System: Component Cooling Operating Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-400A,B,C,D HCV-401A,B,C,D - HCV-402A,B,C,D Tempera-HCV-403A,B,C,D ture F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A h/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical m

Component Cooling water to cont.

Spray N/A N/A N/A N/A N/A NONE

L air cooling units Accuracy - Spac: N/A 5

8 Demon: N/A Radiatiori 2.5x10 R 2x10 R 1

2 Type Test NONE Service: See Function Location: Room 69 Agin; N/A 10 yrs N/A 2

Type Test.

NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implement. *J on Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6b Page 19, Figure 4.2-4 (December 1979)
2) ASCO Test Report Model AQS 21678/TR
n Present Qualification E!

IEEE 323-1974 c;

5

,~

s

Facility: Fort Calhoun 1 Docket No.:

50-285 R4-3 SYSTEM COMPONENT EVALUATON WORK SHEET ENv1RnNMvvT nnmmrmTne nrr QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi~

Qualifi-METHOD ITEMS Parameter catinn entinn entinn entinn System: Component Cooling Operating Time 1000 hrs enntinunne Nnte 9 1

Typa Tae Vnvr Item No.: HCV-400A,B,C,D HCV-401A,B,C,D - HCV-402A,B,C,D Tempera-HCV-403A,B,C,D ture *F N/A N/A N/A N/A M/A V0VF Component: Limit Switch Pressure PSIR N/A N/A N/A N/A N/A MOVF Manufacturer: NAMCO Relative Model No.: EA-180 Humidity 4 N/A N/A N/A N/A N/A NONF l

Function: Valve Actuators for Chemical Component Cooling water to cont.

Spray N/A N/A N/A N/A N/A MnMF 7

air cooling units Accuracy - Spec: N/A Demon: N/A Radiation 2.5x105 R 2.04x10sR 2

1 Type Tes t

Novv Service: See Function Location: Room 69 Aging N/A Note 1 N/A Note 1 N/A WOMF Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NOKF Documentation

References:

Notes:

1) NAMCO Test Report Model EA 180
1) Switches qualified for 40 years using NAMCO September 5,1978 recommended maintenance. NAMCO letter dated
2) " Implementation Methous and Schedules for NUREG-0578" 7/16/30.

Section 2.1.6B, Page 19 Figure 4.2-4 (December 1979)

2) See Enclosure #14.

E Present Qualification E$

IEEE 323-1974 e

N 03 N

4574/a-8/g

Facility: Fort Calhoun 1 Docket No.:

50-285 C-26E SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Component Cooling System Time Continuous Continuou:

1 2

Type Test NONE Item No.: HCV-438A, HCV-438C, HCV-467A, HCV-467C Tempera-ture F

.305 F 340 F 1

2 Type Test NONE Component: Limit Switch Pressure PSIg 60 psig 70 psig 1

2 Type Test NONE Manufacturer: NAMCO Relative Model No.- EA-180-11302 Humidity %

100%

100%

1 2

Type Test NONE E

Function: Position Indication Chemical 1700 ppm PH 10-11 for Valves Spray Boron Boron 1

2 Type Test NONE c3

.L.

@j Accuracy - Spec: N/A 8

Demon: N/A Radiation Note 3 2.04x10 R 1

2 Type Test NONE Service: See Function 10 yrs ocation: Containment Aging N/A Note 2 Note 2 Note 2 Type Test NONE Flood Level Elev:

1000.9' Submer-Type Test Above Flood Level: Yes gence Note 1 Note 1 N/A N/A Note 1 NONE Documentation

References:

Notes:

1) Enclosure #1
1) The switches were sealed & tested to 70 PSIg. The District
2) NAMCO Test Report Model EA 180 considers them capable of withstanding submergence.

September 5,1978

2) Switches qualified for 40 years using NAMCO recommended maintenance.

NAMCO letter dated 7/16/80.

6 7

5 Present Qualification:

3) 9/72x10 R for HCV-467C, Sector A + A'; 1.722x10 R for 6

IEEE 323-1974 HCV-467A, Sector A + A' + B; 5.34x10 R for HCV-438A,

!3 Sector A; 4.38x10 R for HCV-438C, Sector A'.

6 C

E$

4) HCV-438C, HCV-467A, & HCV-467C may be subject to submergence.

ao N

4574/a-48/g

Facility: Fort Calhoun 1 Docket No.:

50-285 6-53 SYSTEM COMPONENT EVALUATON k'ORK SHEET ENVIRONFfENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Component Cooling System Time 1000 hrs Note 2 Note 2 2

Type Test NONE Item No.: HCV-438A, HCV-438C, Tempera-ture *F

.305 F 340 F 1

2 Type Test NONE Component: Solenoid Pressure PSIg 60 psig 110 psig 1

2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP-8320A185E Humidity %

100%

100%

1 2

Type Test NONE Function: Remote Operation of Chenical 1700 ppm 3000 ppm Valves Spray Boron Boron PHIC 1

2 Type Test NONE G$

Accuracy - Spec: N/A 3x10 R/hr 6

8 Demon: N/A Radiation Submerged 2x10 R 1

2 Type Test NONE Service: See Function Location: Containment Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev:

1000.9' Submer-Above Flood Level: No gence Note 1 Note 1 Note 1 Note 1 Type Test NONE Documentation

References:

Notes:

1) Enclosure #1
1) The solenoids may be subject to submergence. An evalua-
2) ASCO Test Report No. AQS 21678/TR tion has been conducted to determine radiation exposure and suitability for the subsequent environment. The District feels there is some question to the submergence R$

Present Qualification:

qualification so an EEAR (FC-81-123) was issued to have IEEE 323-1974 the solenoids moved above flood level.

R$

2) Radiation is limiting qualification shon adjusting 7

E$

1.92x10 R for 1000 HR using DOR Guidelines, Nomagrans jy qualification is adequate.

4574/a-49/g

Facility: Fort Calhoun 1 Docket No.:

50-285 C-33 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRON >fENT norWFMT\\ Tov RFP QUALIFI-OUTSTAhT-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi Qualifi-METHOD ITEMS Pa rameter cation cation ention entinn System: Containment HVAC Time Continuou Continuo'is Note 1

?

Tune Toc t MnMr Item No.: PCV-742A, 742C Tempera-ture F 305*F 340*F 1

2 Type Ten t NnNr Component: Limit Switch Pressure PSIg 60 psig 110 psie 1

2 Type Tes t NONF Manufacturer: NAMCO Relative Model No.: EA-180 Humidity 1 100%

100%

1 2

Tvpe Tes t-NOMF i

Function: Position Indication Chemical 1700 ppm PH 10-11

! as Spray Boron Boron 1

2 Type Test NOME

, s

, C$

Accuracy - Spec: N/A Demon: N/A Radiation Note 1 2.04x1083 1

2 Tvpe Tes t-NOVF Service: See Function Location: Containment Aging N/A Note 2 N/A 2

Type Ten t ungF Flood Level Elev:

1000.9' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

7 for PCV-742 A Sector G & H

1) Enclosure #1 1) 1.09 x 10 7 for PCV-742C Sector F & G
2) NAMCO Test Report Moedl EA 180 1.12 x 10 September 5, 1978
2) Switches qualified for 40 years using NAMCO recommended maintenance. Namco letter dated
y 7/16/80.
w

. m

N %

M C)

- s N

4574/a-46/g

Facility: Fort Calhoun 1 Docket No.:

50-285 R2-3 SYSTEM COMPONENT EVALUATON WORK SHEET EvvinnetrNT nnenMvvT!Tnu nrv QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation carinn ration System: Component HVAC Operating Time 1000 hrs 1000 hrs Note 1 2

Tvpe Test NONE Item No.: A/HCV-742 - C/HCV-742 B/HCV-742 - D/HCV-742 Tempera-ture F N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical j'

Component HVAC Isolation Spray N/A N/A N/A N/A N/A NONE Accuracy - Spec: N/A Demon: N/A Radiation 8x105 8

R 2x10 R 1

2 Type Test NONE Service: See Function i

Location: Room 59 Aging N/A 10 yrs N/A 2

Type Test NONE 1

Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 18, Figure 4.2-3 (December 1979)
2) ASCO Test Report Model AQS 21678/TR d

Present Qualification n,

IEEE 323-1974 E2

, R3 O

Facility: Fort Calhoun 1 Docket No.:

50-385 R4-5 SYSTEM COMPONENT EVALUATON WORK SHEET ENvinnNkWNT DAMnWMT?TAV DFF QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation entinn entinn System: Component HVAC Operating Time 1000 hrs 1000 hrs Note 1 2

Tvpe Test NONE Item No.: PCV-742B PCV-742D Tempera-ture F N/A N/A N/A N/A N/A NONE 1

Component: Solenoid Valve Pressure I

PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 831655E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical Component HVAC Isolation Spray N/A N/A N/A N/A N/A NONE as us Accuracy - Spec: N/A Demon: N/A Radiation 2.5x10sR 2x10 R 1

2 Type Test NONE 8

Service: See Function Location: Room 69 Aging N/A 10 yrs N/A 2

Type Test.

NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

l

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 l

Section 2.1.6B Page 19, Figure 4.2-4 (December 1979) l

2) ASCO Test Report Model AQS 21678/TR

,ml"'

Present Qualification l Cf IEEE 323-1974 l2$

! 03 l na e

Facility: Fort Calhoun 1 Docket No..

50-285 R4-6 SYSTEM COMPONENT EVALUATON k'ORK SifEET ENVIRONMENT DOCU'fFNTATON REF.

QUALIFI-OUTSTAND CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Containment HVAC Operating i

l Time 1000 hrs Continuous Note 2 2

Type Test NONE Item No.: PCV-742B, 742 Tempera-ture F N/A N/A N/A N/A N/A NONE 1

Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 Humidity % N/A N/A N/A N/A N/A NONE Function: Position Indicaton for Chemical Containment Purge Isolation Valve-Spray N/A N/A N/A N/A N/A NONE Accuracy - Spec: N/A

t 1

2 Type Tesi.

NONE 5 F 2.04x108 Demon: N/A Radiatior 2.5x10 Service: See Function Location: Room 69 Aging N/A Note 1 N/A Note 1 N/A NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) Switches qualified for 40 years using NAMCO Section 2.1.6B Page 19, Figure 4.2-4 (December 1979) recommended maintenance. NAMCO letter dated
2) NAMCO Test Report Model EA 180 7/16/80.

September 5, 1978.

2) See Enclosure //14.

w Present Qualification m

S IEEE 323-1974 S

~

Facility: Fort Calhoun 1 Docket No.:

50-285 C-31 SYSTEM COMPONENT EVALUATON WORK SHEET ENVTRnVMENT M NNFMTATnv WFr QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi Qualifi-METHOD ITEMS Pa ramet er cation catinn carinn carian System: Containment HVAC Time Continuous continunus Nnte 1

?

Type Tec vner Item No.: PCV-742A, 742B

{

HCV725A, 725B Tempera-ture *F 305*F 340*F 1

?

Type Tec t Nnvr l

l l

Component: Limit Switch Pressure PSIR 60 psie 110 osig 1

2 Tyne Tee r

NnMF Manufacturer: NAMCO Relative Model No.: EA-180 Humidity 4 100%

1001 1

?

Tyne Tec t

NnMF Function: Position Indication Chemical 1700 ppm PH 10-11 Spray Boron Boron 1

?

Tyne Tee r vnvr es i

w F

Accuracy - Spec: N/A 1.92 x 10 R e

Demon: N/A Radiation Sector 0 2.04x1061 1

?

Type Tee r Knvv Service: See Function l

Location: Containment Aging N/A Note 1 N/A 9

Type Tec t

NnVF Flood Level Elev:

1000.9' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A MAMF Documentation

References:

Notes:

1) Enclosure #1
1) Switches qualified for 40 years using NAMCO
2) NAMCO Test Report Moedl EA 180 recommended maintenance. NAMCO letter dated September 5,1978 7/16/80.

1x W

,N 1%s me 1 O

! w%

l 03 i N 4574/a-47/g

Facility:

Fort Calhoun 1 Docket No.:

50-285 R3-1 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRON 1fENT DOCINFNTATON REF.

QUALIFI-OtrfSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METH00 ITEMS Parameter cation cation cation cation System: Containment HVAC Operating Time 1000 hrs 1000 hrs Note 2 2

Type Test NONE Item No.: PCV-742F, 742H, PCV-746B Tempera-ture F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: Note 1 Humidity 1 N/A N/A N/A I

N/A N/A NONE Function: Valve Actuators for Chemical p

Component HVAC Isolation Spray N/A N/A N/A N/A N/A NONE w*

Accuracy - Spec: N/A 5

8 Demon: N/A Radiatiori 6x10 R 2x10 R 1

2 Type Test.

NONE Service: See Function Location: Room 60 Aging N/A 10 yrs N/A 2

Type Tes1.

NONE Flood Level Elev: Nf Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for KUREG-0578"
1) HCV-746B is a NP 8314C29E Section 2.1.6B Page 18, Figure 4.2-3 (December 1979)

PCV-742F & 742H are NP 8320A185E

2) ASCO Test Report Model AQS 21678/TR
2) See Enclosure #14 o

Present Qualification 2

IEEE 323-1974 K

si u

Facility: Fort Calhoun 1 Docket No.:

50-285 1-8 SYSTEM COMPONENT EVALUATON k'ORK SHEET vvvinnvurvT nnenwrvT!Tnv nrr QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation carinn ratinn carinn System: Containment Spray Operating 1000 hrs Time Note 1 Continuous Note 3 3

Type Test NONE Item No.: HCV-2957 & 2958 Tempera-ture *F 109*F 340*F 2

3 Type Test NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA 180 Humidity 1 100%

100%

2 3

Type Test NONE Function: Position Indication Chemical p

for HCV-2957 & 2958 Spray N/A N/A N/A N/A N/A NONE t.a Accuracy - Spec: N/A Demon: N/A Radiation 7x10 R 2.04x108 G

1 1

3 Type Tesi NONE Service: Cont. Spray PP SI-3A Isolation valve Pos. Ind.

Location: Room 22 (SI Pumps)

Aging N/A Note 2 N/A Note 2 N/A NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #18 Section 2.1.6B Page 19, Figure 4.2-4 (December 1979)
2) Switches qualified for 40 years using NAMCO recommended

]

2) Combustion Eng. Study " Evaluation of Fort Calhoun maintenance. NAMCO letter dated 7/16/80.
x Safety Injestion Pump Room Temperature following a
3) See Enclosure #14.

Loss of Coolant Accident," see OPPD letter to the I D$

NRC dated 9/6/79.

22
3) NAMCO Test Report Model EA-180 l $3 September 5,1978 Present Qualification IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.:

50-285 I-9 SYSTEM COMPONENT EVALUATON k'ORK SHEET FNVTRAVMFMT nnrifMFVTMTnV DFF QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-MET 110D ITEMS Parameter cation ention cation cation System: Containment Spray Operating 1000 hrs Time Note 1 Continuoi s Note 3 3

Tyne Test NONE Item No.: HCV-2967, 2968, 2977 and 2978 Tempera-ture *F 109*F 340 F 2

3 Type Test NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE l

Manufacturer: NAMCO Relative i

Model No.: EA 180 Humidity 1 100%

100%

2 3

Type Test NONE Function: Position Indication Chemical es Spray N/A N/A N/A N/A N/A NONE n

C' Accuracy - Spec: N/A i

8 8

Demon: N/A Radiation 7x10 R 2.04x10 R 1

3 Type Test NONE Service: Cont. Spray PP SI-3B, 3C, Isolation valve Pos. Ind.

Location: Room 22 (SI Pumps)

Aging N/A Note 2 N/A Note 2 N/A NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #18 Section 2.1.6B Page 18, Figure 4.2-3 (December 1979)
2) Switches qualified for 40 years using NAMCO recommended
2) Combustion Eng. Study " Evaluation of Fort Calhoun maintenance. NAMCO letter dated 7/16/80.

m Safety Injestion Pump Room Temperature following a

3) See Enclosure #14.

Loss c f Coolant Accident," see OPPD letter to the

R NRC dated 9/6/79.

! A3

3) NAMCO Test Report Model EA-180 03 September 5, 1978 Present Qualification IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.: 50-285 R2-5 SYSTEM COMPONENT EVALUATON k'ORK SHEET rwinnwrrr nommverf Tov nvr QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Speci fi-Qualifi-METHOD ITEMS Parameter cation ention cation cation System: Containment Spray Operating Time 1000 hrs 1000 hrs Note 1 2

Tyne Test NONE Item No.: HCV-344, 345 Tempera-ture *F N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSig N/A N/A A

N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity 1 N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical Containment Spray Header Spray N/A N/A N/A N/A N/A NONE os

  • =

Isolation Values Accuracy - Spec: N/A 5

8 Demon: N/A Radiation 8x10 R 2x10 R 1

2 Type Test NONE Se rvice: See Function Location: Room 59 Aging N/A 10 yrs N/A 2

Type Tes1.

NONE 4

Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 18, Figure 4.2-3 (December 1979)
2) ASCO Test Report Model AQS 21678/TR
o Present Qualification

[$

IEEE 323-1974 e

. R

Facility: Fort Calhoun 1 Docket No.:

50-285 R4-7 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rameter cation cation cation cation System: Demineralized Water Operating Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-1559A, 1559B HCV-1560A, 1560B Tempera-ture *F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity % N/A N/A N/A N/A.

N/A NONE Function: Valve Actuators for Chemical

. cs Demineralized Water Spray N/A N/A N/A N/A N/A NONE

6."

Accuracy - Spec: N/A 8

Demon: N/A Radiation 2.5x10sR 2x10 R 1

2 Type Test NONE Service: See Function Location: Room 69 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 19, Figure 4.2-4 (December 1979)
2) ASCO Test Report Model AQS 21678/TR

.m Present Qualification

' Cf IEEE 323-1974

' cs

. 53 m

Facility: Fort Calhoun 1 Docket No.:

50-265 C-51 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-l Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation-cation cation System: Hydrogen Purge System Time 1000 hrs Note 1 Note 1 2

Type Test NONE Item No.: HCV-883A, 884A Tempera-ture *F

.305*F 340*F 1

2 Type Test NONE Component: Solenoid Pressure i

PSIg 60 psig 110 psig 1

2 Type Test NONE Manufacturer: ASCO Relative Model No.:

Humidity %

100%

100%

1 2

Type Test NONE Function: Remote Operation of Chemical 1700 ppm 3000 ppm Valves Spray Boron Boron PHIC 1

2 Type Test NONE 03 Accuracy - Spec: N/A 6

8 Demon: N/A Radiation 3x10 R 2.04x10 R 1

2 Type Test NONE Service: See Function Location: Containment Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev:

1000.9' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A Type Test NONE Documentation

References:

Notes:

1) Enclosure #1
1) Radiation is limiting, qualification shown adjusting 7
2) ASCO Test Report No. AQS 21678/TR 1.92x10 R for 1000 HR using DOR Guideline NoMagrams
3) ASCO Letter Dated July 10, 1980 qualification is adequate.

Present Qualification:

IEEE 323-1974 g

4574/a-52/g

Facility:

Fort Calhoun 1 Docket No.:

50-285 I-30 SYSTEM COMPONENT EVALUATON WORK SHEET puvinnemyr noemmer! Tnv DFF QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: High Pressure Safety Operating Injection Time 1000 hrs 1000 hrs Note 1 3

Tyne Test NONE Item No.: HCV-304 and 305 Tempera-ture F 109 F 346*F 2

3 Type Test NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative

.Model No.: NP 8314C29E Humidity

'1 100%

100%

2 3

Type Test NONE Function: Valve Actuators for Chemical High Pressure Safety Injection Spray N/A N/A N/A N/A N/A NONE o3 f3 Header Isolation Valves Accuracy - Spec: N/A d'

6 8

Demon: N/A Radiatior 7x10 R 2x10 R 1

3 Type Test NONE Service: See Function Location: Room 21 (SI Pumps)

Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) Values are locked open and do not operate during Section 2.1.6B Page 16, Figure 4.2-1 (December 1979) an event. The value is expected to function
2) Combustion Engineering study " Evaluation of Fort adequately for long term core cooling.

See Calhoun Safety Injection Pump Room Temperature Enclosure #14.

x, following a Loss of Coolant Accident", see OPPD Co letter to the NRC dated 9/6/79.

g

3) ASCO Test Report Model AQS 21678/TR S

N Present Qualification IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.:

50-285 I-13 SYSTiti COMPONENT EVALUATON k'ORK SHEET rwT unwvn nnemtr e Tn" err QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parnmeter entinn entinn entinn entinn System: High Pressure Safety Operating Note 1 Injection Time 1000 hrs Continunne Nnt e *1

'l Tme Test NONF Item No.: HCV-304 and 305 Tempera-ture F 109 F 140 F 2

3 Tyne Test NONE Component: Limit Switch Pressure PSIR N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA 180 Humidity % 100%

100%

2 3

Type Test.

NONE Function: Position Ino1 cation fc r Chemical HCV-304 & 305 Spray N/A N/A N/A N/A N/A NONE

/:n, Accuracy - Spec: N/A u

Demon: N/A Radiatior 7x10 R 2.04x108 1 1

3 Type Test NONE 6

Service: HPSI pump Disch.

Header Isol valve Pos. Ind.

Location: Room 21 (SI Pumps)

Aging N/A Note 2 N/A Note 2 N/A NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation Rt.crences:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #18 Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)
2) Switches qualified for 40 years using NAMCO
2) Combustion Engineering study " Evaluation of Fort recommended maintenance. NAMCO Letter dated Calhoun Safety Injection Pump Room Temperature 7/16/80.

g; following a Loss of Coolant Accident", see OPPD

3) See Enclosure #14.

letter to the NRC dated 9/6/79.

3) NAMCO Test Report Model EA 180 September 5, 1978 m

Present Qualification IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.:

50-285 j

I-2 SYSTEM COMPONENT EVALUATON WORK SHEET I

ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING F.QUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rameter cation cation cation cation System: High Pressure Safety Operating Injection System Time 1000 hrs 1000 hrs Note 1 3

Type Test NONE Item No.: HCV-383-1 and 383-2 Tempera-ture 'F 109 F 346 F 1

3 Type Test NONE Component: Solenoid Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity %

100%

100%

1 3

Type Test NONE Function: Valve Actuators for Chemical High Pressure Safety Injection Spray N/A N/A N/A N/A N/A NONE os f3 Header Isolation Valves 4

os Accuracy - Spec: N/A 6

8 Demon: N/A Radiation 7x10 R 2x10 R 2

3 Type Test NONE Service: See Function Location: Room 21 (SI Pumps)

Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) Combustion Engineering study " Evaluation of Fort
1) LCV-383-1 & 2 are required to close on receipt of a Calhoun Safety Injection Pump Room Temperature RAS signal. This occurs 20 minutes into the event.

following a Loss of Coolant Accident", see OPPD Valves close in 10 seconds.

In addition check valves letter to the NRC dated 9/6/79.

are provided to ensure proper operation. These gj

2) " Implementation Metho'ds and Schedules for NUREG-0578" solenoids are expected to remain functional during Section 2.1.6B Page 16, Figure 4.2-1 (Dece nber 1979) the long term core cooling.

See Enclosure #14.

n3::

3) ASCO Test Report Model AQ 521678/TR R

C3 Present Qualification IEEE 323-1974 0

Facility: Fort Calhoun 1 Docket No.:

50-285 I-14 SYSTEM COMPONENT EVALUATON VORK SHEET vwInnimvv7 nnemmvT!Tnsrnvr QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter entinn entinn entinn catinn System: High Pressure Safety Operating Note 1 Injection System Time 1000 hrs Continuous Note 3 1

Type Test NONE Item No.: HCV-383-1 and 383-2 Tempera-ture *F 109 F 340*F 2

3 Type Test NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 llumidity % 100%

100%

2 3

Type Test NONE Function: Pos Ind. for SIRWT Chemical Discharge valves Spray N/A N/A N/A N/A N/A NONE as Ss N

Accuracy - Spec: N/A Demon: N/A Radiatior 7x10 R 2.04x108 1 1

3 3

NONE 6

Se rvice : LCV-383-1 & 2 Pos Ind.

Location: Room 21 (HPSI)

Aging N/A Note 2 N/A Note 2 N/A NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation References.

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #18.

Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)

2) Switches qualified for 40 years using NAMCO recommended
2) Combustion Engineering study " Evaluation of Fort maintenance.

Letterdated 7/16/80.

Calhoun Safety Injection Pump Room Temperature

3) See Enclosure #14.

,o, following a Loss of Coolant Accident", see OPPD u

[3 letter to the NRC dated 9/6/79.

. og

3) NAMCO Test Report Model EA-180 gg September 5, 1978 Present Qualification IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.: 50-285 I-11 SYSTEM COMPONEh"r EVALUATON tVRK SHEET Eh'VT pnNNrh"r noclNFMTATOV RPF QUALIFI-OUTSTANT)-

CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi<

Qualifi-METHOD ITEMS Pa ramet er cation cation cation cation System: High Pressure Safety Operating Note 1 Injection System Time 1000 hrs Continuo us Note 3 3

Type Tes:

NONE Item No.: HCV-2918 & 2928 Tempera-ture *F 109'F 340*F 2

3 Type Test NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 Humidity % 100%

100%

2 3

Type Test NONE Function: Pos Ind. for HCV-2918 Chemical and 2928 Spray N/A N/A N/A N/A N/A NONE Accuracy - Spec: N/A 8

Demon: N/A Radiatior 7x10 R 2.04x106 R 1

3 Type Test NONE Service: ST-2A & 2C Disch Line Location: Room 21 (SI Pumps)

Aging N/A Note 2 N/A Note 2 N/A NCNE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #18.

Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)

2) Switches qualified for 40 years using NAMCO recommended
2) Combustion Engineering study " Evaluation of Fort maintenance.

Letterdated 7/16/80.

Calhoun Safety Injection Pump Room Temperature

3) See Enclosure #14.

.E following a Loss of Coolant Accident", see OPPD letter to the NRC dated 9/6/79.

m 33

3) NAMCO Test Report Model EA-180

, kj September 5, 1978 i

Present Qualification IEEE 323-1974

v Facility: Fort Calhoun 1 Docket No.:

50-285 I-6 SYSTEM COMPONENT EVALUATON kT)RK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OITISTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METH0D ITEMS Parameter cation cation cation cation System: High Pressure Safety Operating Note 1 Injection System Time 1000 hrs Continuou ;

Note 3 3

Type Test NONE Item No.: HCV-2907 & 2908 Tempera-ture *F 109*F 340*F 2

3 Type Test NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 Humidity %

100%

100%

2 3

Type Test NONE Function: Pos Ind. for HCV-2907 Chemical and 2908 Spray N/A N/A N/A W/A N/A NONE S$

Accuracy - Spec: N/A 8

8 Demon: N/A Radiation 7x10 R 2.04x10 R 1

3 Type Test NONE Service: Pos. Ind. for S1 PP 2B Isolation valves Location: Room 21 (SI Pumps)

Aging N/A Note 2 N/A Note 2 N/A NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #18.

Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)

2) Switches qualified for 40 years using NAMCO recommended
2) Combustion Engineering study " Evaluation of Fort maintenance.

Letterdated 7/16/80.

Calhoun Safety Injection Pump Room _ Temperature

3) See Enclosure #14. Valves are locked open and do not I E$

fol, lowing a Loss of Coolant Accident", see OPPD operate during an event.

N>

letter to the NRC dated 9/6/79.

co

3) NAMCO Test Report Model EA-180 jj September 5,1978 Present Qualification IEEE 323-1974

Facility:

Fort Calhoun 1 Docket No.:

50-285 I-5 SYSTEM COMPONENT EVALUATON WORK SliEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METii0D ITEMS Pa rame ter cation cation cation cation System: fligh Pressure Safety Operating Note 1 Injection System Time 1000 hrs Continuou ;

Note 3 3

Type Test NONE Item No.: IfCV-2917 & 2927 Tempera-ture *F 109 F 340 F 2

3 Type Test NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 Ilumidity %

100%

100%

2 3

Type Test NONE Function: Pos Ind. for HCV-2917 Chemical and 2927 Spray N/A N/A N/A N/A N/A NONE as D

Accuracy - Spec: N/A

  • o 6

8 Demon: N/A Radiation 7x10 R 2.04x10 R 1

3 Type Test.

NONE Service: Pos. Ind. for SI PP 2A

& 2C Isolation valv_s Location: Room 21 (SI Pumps)

Aging N/A Note 2 N/A Note 2 N/A NONE Flood Level Elev: N/A Submer-Above Flood Ievel:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #18.

Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)

2) Switches qualified for 40 years using NAMCO recommended
2) Combustion Engineering study " Evaluation of Fort maintenance. Letterdated 7/16/80.

Calhoun Safety Injection Pump Room Temperatare

3) See Enclosure #14. Valves are locked open and do not j,,$

following a Loss of Coolant Accident", see OPPD operate during an event.

o Rd letter to the NRC dated 9/6/79.

So

3) NAMCO Test Report Model EA-180 September 5, 1978 co Present Qualification IEEE 323-1974 O

... =.

Facility: Fort Calhoun 1 Docket No.:

50-285 RI-14 SYSTEM COMPONENT EVALUATON WORK SHEET F wTROUfENT DONnfFMTJ TOM RFF QUALIFI-OUTSTAND-i CATION ING

-t EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rameter cation cation cation cation System: High Pressure Safety Operating Injection Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-306 and HCV-307 Tempera-ture 'F N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical i

Safety Injection Isolation Spray N/A N/A N/A N/A N/A NONE l

- %J

,2 Accuracy - Spec: N/A 8

8 Demon: N/A Radiatiori 4x10 R 2x10 R 1

2 Type Tesi.

NONE j

Service: See Function i

Location: Room 13 Aging N/A 10 yrs N/A 2

Type Tesi.

NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 17, Figure 4.2-2 (December 1979)
3) ASCO Test Report Model AQ 521678/TR in Present Qualification N

i lt3 IEEE 323-1974

' E;4~

Facility:

Fort Calhoun 1 Docket No.:

50-285 RI-15 SYSTEM COMPONENT EVALUATON WORK SIIEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: liigh Pressure Safety Operating Injection Time 1000 hrs Continuou 4

Note 1 2

Type Test NONE Item No.: IICV-306 and HCV-307 Tempera-ture F

.N/A N/A N/A N/A N/A NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 liumidity %

N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical Safety Injection Isolation Spray N/A N/A N/A N/A N/A NONE Accuracy - Spec: N/A 6

8 Demon: N/A Radiation 4x10 R 2.04x10 R 1

2 Type Test NONE Service: See Function Lo ca tio..: Room 13 Aging N/A Note 2 N/A Note 2 Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 17, Figure 4.2-2 (December 1979)
2) Switches qualified for 40 years using NAMCO
2) NAMCO Test Report Model EA 180 recommended maintenance letter dated 7/16/80.

g September 5, 1978 w

Present Qualification IEEE 323-1974 R$

~

t Facility: Fort Calhoun 1 Docket No.:

50-285 R7-1 SYSTEM COMPONENT EVALUATON WORK SHEET rWTunwvT nortNrvT.!Tnv nrv QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation catinn cation

[

System: Hydrogen Sampling Operating Time 1000 hrs 1000 hrs Note 1 2

Tyne Test NONE Item No.: HCV-883B HCV-884B

' Tempera-ture 'F

- N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8320A185E Humidity 1 N/A N/A N/A N/A N/A NONE i

i Function: H Containment Chemical 2

Sampling Spray N/A N/A N/A N/A N/A NONE

. O 03 Accuracy - Spec: N/A Demon: N/A Radiation 8x10 R 2x10sR 1

2 Type Tesi.

NONE 5

Service: See Function Location: Room 59 Aging N/A 10 yrs N/A 2

Type Tes1.

NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B
2) ASCO Test Report Model AQS 21678/TR 3

Present Qualification IEEE 323-1974 n,

~ 23

EE

!n i

i 1

Facility: Fort Calhoun 1 Docket No.:

50-285 R7-0 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIF1-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD

TFMS Pa rameter cation cation cation cation System: Hydrogen Sampling Operating Time 1000 hrs Continuou s

Note 1 3

Type Test NONE Item No.: HCV-883A HCV-884A Tempera-l ture *F

.N/A N/A N/A N/A N/A NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 Humidity %

N/A N/A N/A N/A N/A NONE 1

Function: If Containment Chemical 2

Sampling Spray N/A N/A N/A N/A N/A NONE o,

D Accuracy - Spec: N/A Demon: N/A Radiation 8x10 R 2.04x10 R 1&2 3

Type Test NONE 5

8 Service: See Function Location: Room 59 Aging N/A Note 2 N/A Note 2 N/A NONE Flood Level Elev: N/A Submer-t Above Flood Level:

ge'nce N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B
2) Switches qualified for 40 years using NAMCO l
2) NAMCO Controls Letter Dated March 11, 1980 recommended maintenance letter dated 7/16/80.
3) NAMCO Test Report.Model EA-180, September 5, 1978 l

Present Qualification l [o IEEE 323-1974 1

N

EG i

' E3 h)

O

Facility: Fort Calhoun 1 Docket No.:

50-285 R4-9 SYSTEM COMPONENT EVALUATON k'ORK SifEET ENVIRON >fENT DOCIMENTATOV REF-QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa ramete r cation cation cation cation System: Instrument Air Operating Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: PCV-1849 Tempera-ture 'F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical Instrument Air Isolation Spray N/A N/A N/A N/A N/A NONE OS Accuracy - Spec: N/A Demon: N/A Radiatior 2.5x10sR 2x10sR 1

2 Type Test NONE Service: See Function Location: Room 69 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 19, Figure 4.2-4 (December 1979)
2) ASCO Test Report Model AQS 21678/TR Present Qualification

!)$

IEEE 323-1974

~

t3

.o

v

Facility: Fort Calhoun 1 Docket No.:

50-285 I-12 SYSTEM COMPONENT EVALUATON WRK SHEET ENVIRONMENT DOCUMEN1ATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Low Pressure Safety Operating Note 1 Injection Time 1000 hrs Continuou s

Note 2 3

Type Test NONE Item No.: HCV-2947 and 2948 Tempera-ture F 109 F 340*F 1

3 Type Test NONE i

Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 Humidity %

100%

100%

1 3

Type Test NOME Function: Position Indication for Chemical HCV-2947

  • 2948 Spray N/A N/A N/A N/A N/A NONE 3

Accuracy - Spec: N/A Demon: N/A Radiation 7x10 R 2.04x10sR 2

3 Type Test NONE 6

Service: SI-IA Isol valves Pos. Ind.

Location: Room 21 (SI Pumps)

Aging N/A Note 3 N/A Note 3 Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gehce N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) Combustion Engineering Study " Evaluation of Fort
1) See Enclosure #18.

Calhoun Safety Injection Pump Room Temperature

2) Valves are locked open and do not following a Loss of Coolant Accident. See OPPD operate during an event. See Enclosure #14.

letter to the NRCdated 9/6/79.

3) Switches qualified for 40 years using NAMCO lg;
2) " Implementation Methods and Schedules for NUREG-0578" recommended maintenance letter date 7/16/80.

g Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)

3) NAMCO Test Report Model EA-180.

i 53 September 5,1978 00 Present Qualification i

IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.:

50-285 I-10 SYSTEM COMPONENT EVALUATON VORK SHEET n,nunvun r pocifervT; T0" PEF-QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter catinn entinn carinn entinn System: Low Pressure Safety Operating Note 1 Injection Time 1000 hrs Continuous Note 2 3

Type Test NONE Item No.: HCV-2937 and 2938 Tempera-ture *F 109'F 340*F 1

3 Type Test NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 Humidity % 100%

100%

1 3

Type Test NONE Function: Position Indication fc r Chemical HCV-2937 & 2938 Spray N/A N/A N/A N/A N/A NONE S

Accuracy - Spec: N/A Demon: N/A Radiatiori 7x10 R 2.04x108 6

3 2

3 Type Test NONE Service: LPSI PP IB Isol valves Pos. Ind.

Location: Room 22 (SI Pumps)

Aging N/A Note 3 N/A Note 3 N/A NONE Flcod Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) Combustion Engineering Study " Evaluation of Fort
1) See Enclosure #18.

Calhoun Safety Injection Pump hoom Temperature

2) Valves are locked open and do not following a Loss of Coolant Accident. See OPPD operate during an event. See Enclosure #14.

letter to the NRCdated 9/6/79.

3) Switches qualified for 40 years using NAMCO
2) " Implementation Methods and Schedules for NUREG-0578" recommended maintenance letter date 7/16/80.

x

[

Section 2.1.6B Page 16, Figure 4.2-1 (December 1979)

3) NAMCO Test Report Model EA-180.

c3 September 5, 1978 Present Qualification IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.:

50-285 RI-5 SYSTEM LOMPONENT EVALUATON WORK SHEET Fwinn9fFVT DnN Nh'T h9.W WF QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation ention entinn i

System: Low Pressure Safety Operating Injection Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: FCV-326 and HCV-341 Tempera-i ture *F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical Low Pressure Safety Injection Sp ray N/A N/A N/A N/A N/A NONE E$

Accuracy - Spec: N/A 8

8 Demon: N/A Radiatior 4x10 R 2x10 R 1

2 Type Test NONE Service: See Function Location: Room 13 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14.

Section 2.1.6B, Page 17, Figure 4.2-2 (December 1979)

2) ASCO Test Report Model AQS 21678/TR
o Present Qualification

' Ef IEEE 323-1974 8

Es m

1

.~. -

. - _. ~_

~

Facility: Fort Calhoun 1 Docket No.:

50-285 C-12 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Main Steam Note 1 Time Intermittent 1000 hrs 1

2 Type Test NONE Item No.: MS 291, 292 Tempera-ture *F

.216 F 346*F 1

2 Type Test NONE Component: Solenoid Pressure PSIg 1.2 psig 110 psig 1

2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP-8320A185E Humidity %

100%

100%

1 2

Type Test NONE Function: Main Steam Safety Chemical Relief Valve Operator Spray N/A N/A N/A N/A Type Test NONE T'

t

^ j!

Accuracy - Spec: N/A Demon: N/A Radiation N/A N/A N/A N/A Type Test NONE Service: See Function Location: Room 81 Aging N/A N/A N/A N/A Type Test NONE Flood Level Elev:

1037'-4" Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes

1) Enclosure #2
1) The Main Steam Safeties can be used as an alternate
2) ASCO Test Report No. AQS 21678/TR path of decay heat removal using the Aux Feedwater System and the Steam Generators. See Enclosure #18.

Present Qualification-j' IEEE 323-1974 Et 2;

ca i

no 4574/a-50/g

Facility:

Fort Calhoun 1 Docket No.:

50-285 S-11 SYSTEM COMPONENT EVALUATON WORK SHEET l

FNVT RO9fFNT 00r1HENT! TOV MFF.

QUALIFI-OU?S1,ND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa ramet er cation cation cation cation System: Main Steam Operating Time Note 1 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-1041A and 1042A Tempera-ture F 216*F 346 F 1

2 Type Test NONE Component: Solenoid Valves 1&2 Pressure PSIg 1.2 psig 110 psig 1

2 Type Test NONE Manufacturer: ASCO i

Relative Model No.: NP 8316E37E Humidity % 100%

100%

1 2

Type Test NONE NP 8316A77E Function: Pilot & Test Solenoids Chemical for main steam isolation valves Spray N/A N/A N/A N/A N/A NONE y,

Accuracy - Spec: N/A Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Se rvice : Main Steam Isolation valves Location: Room 81 Aging N/A 10 yrs N/A 2

Type Test NONE i

Flood Level Elev:

1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) See Enclosure #2
1) Valve solenoid de-energizes to close the valve. There
2) ASCO Test Report Model AQS 21678/TR is no requirement to operate after initial closure.

In the District's engineering judgment, the isolation valve Present Qualification will maintain the closed position.

In order for the

_g

j na IEEE 323-1974 isolation valve to re-open, steam pressure must be balanced on both sides of the valve seat. Under the lig;

[3 postulated accident condition this situation is highly j;g unlikely.

In addition, the pilot valve material is capable of withstanding the postulated temp. without

- n) failure of internal components.

Facility: Fort Calhoun 1 Docket No.:

50-285 R2-7 SYSTEM COMPONENT EVALUATON WORK SliEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-MET 110D ITEMS Pa ramete r cation cation cation cation System: Nitrogen System Operating Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE.

Item No.: IICV-2603A and 2604A Tempera-ture F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Ilumidity %

N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical Nitrogen System Isolation Spray N/A N/A N/A N/A N/A NONE asE Accuracy - Spec: N/A N

6 5

Demon: N/A Radiation 4x10 R 8x10 R 1

2 Type Test NONE Service: See Function Location: Room 59 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev:

N/A Submer-ge'ce N/A N/A N/A N/A N/A NONE Above Flood Level:

n Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14.

Section 2.1.6B Page 18, Figure 4.2-3 (December 1979)

2) ASCO Test Report Model AQS 21678/TR
o Present Qualification w

Rt IEEE 323-1974 2

4

Facility: Fort Calhoun 1 Docket No.:

50-285 R4-11 SYSTEM COMPONENT EVALUATON WORK SHEET l

FNVIROPfENT nor19fFMTATOM DFF QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Plant Air Operating Time 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: IICV-1749 i

Tempera-ture *F N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity 'I N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical Plant Air Isolation Spray N/A N/A N/A N/A N/A NONE

d$

Accuracy - Spec: N/A Demon: N/A Radiatior 2.5x10 R 2x10sR 1

2 Type Test NONE 5

Service: See Function Location: Room 69 Aging N/A 10 yrs N/A 2

Type Tesi NONE Flood Level Elev: N/A Submer-Above Flood Levei:

gence N/A N/A N/A N/A N/A NONE Docmnentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14.

Section 2.1.6B Page 19, Figure 4.2-4 (December 1979) i

2) ASCO Test Report Model AQS 21678/TR i ES Present Qualification i no IEEE 323-1974
2

lR IB

Facility: Fort Calhoun 1 Docket No.:

50-285 S-14 SYSTEM COMPONENT EVALUATON WORK SHEET FwinowvgT nommvnTtTnw nvr QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rameter cation cat; ion cation cation System: Raw Water Operating Time Note 1 1000 hrs Note 1 1

Type Test NONE Item No.: HCV-2898C, 2898D HCV-2899C, 2899D Tempera-ture F 216*F 346 F 2

1 Type Test NONE Component: Solenoid Pressure PSIg 1.2 psig 110 psig 2

1 Type Test NONE Manufacturer: ASCO Relative Model No.: NP 8320A185E Humidity % 100%

100%

2 1

Type Test NONE Function: Valve Actuators for Chemical Inlet & Cutlet valves for Spray N/A N/A N/A N/A N/A NONE S'

control room air cond. units E$

Accuracy - Spec: N/A Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: See Function Location: Room 81 Aging N/A 10 yrs N/A 1

Type Test NONE Flood Level Elev:

1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) ASCO Test Report Model AQS 21678/TR
1) Valves are required to operate only if there is a failure
2) See Enclosure #2.

of the Component Cooling System.

Present-Qualification IEEE 323-1974 D

si

n t

Facility: Fort Calhoun 1 Docket No.:

50-285 I-29 SYSTEM COMPONENT EVALUATON k'ORK SHEET vvvinnetruT nnmnervra Tne nrr QUALIFI-OLTFSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter entinn entinn entinn entinn System: Raw Water Operating Note 2 Time 1000 hrs 1000 hrs Note 1 1

Type Test WANE Item No.: HCV-2809C, 2809D, 2811C, 2811D, 2814C, 2814D, 2815C, 2815I Tempera-i ture *F ICs*F 346 F 1

3 Type Test NONE i

Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8320A185E Humidity % 100%

100%

1 3

Type Test.

NONE Function: Valve Actuators for Chemical inlet & outlet valves for SI &

Spray N/A N/A N/A N/A N/A NONE t o, Spray pumps bearing coolers.

' C3 Accuracy - Spec: N/A Demon: N/A Radiatior 7x10 R 2x10sR 2

3 Type Test NONE 8

Se rvice: See Function Location: Room 22 (SI pumps)

Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) Combustion Engineering study " Evaluation of Fort
1) Valves are locked open and do not operate during Calhoun Safety Iajection Pump Room Temperature following an event. See Enclosure #14.

a Loss of Coolant Accident.

(See OPPD letter to the

2) See Enclosure #18.

NRC dated 9/6/79)

2) " Implementation Methods and Schedules for NUREG-0578" y

Section 2.1.6B Page 16, Figure 4.2-1 (Deces.ber 1979)

' o' Rd

3) ASCO Test Report Model AQS 21678/TR gg Present Qualification N

IEEE 323-1974

Facility: Fort Calhoun 1 Docket No.:

50-285 I-28 SYSTEM COMPONENT EVALUATON WORK SHEET FNVT ROPfFMT dor 1NFMTATOM DFF QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rameter cation cation c * 'on cation System: Raw Water Operating Note 1 Time 1000 hrs 1000 hrs Note 2 3

Type Test NONE Item No.: HCV-2808C, 2808D, 281CC, 2810D, 2812C, 2812D, 2813C, 2813T Tempera-ture *F 109*F 346 F 1

3 Type Test.

NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8320A185E Humidity % 100%

100%

1 3

Type Test NONE Function: Valve Actuators for Chemical inlet & outlet valves for SI &

Spray N/A N/A N/A N/A N/A NONE y,

j, Spray pumps bearing coolers.

g4 Accuracy - Spec: N/A 8

8 Demon: N/A Radiatior 7x10 R 2x10 R 2

3 Type Test NONE Service: See Function Location: Room 22 (SI pumps)

Aging N/A 10 yrs N/A 3

Type Test NONE Flood Level Elev: N/A Submer-f Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) Combustion Engineering study " Evaluation of Fort
1) See Enclosure #18.

Calhoun Safety Injection Pump Room Temperature following 2) Valves are locked open and do not operate during an a Loss of Coolant Accident.

(See OPPD letter to the event.

See Enclosure #14.

NRC ated 9/6/79)

.g

2) " Implementation Methods and Schedules for NUREG-0578 Section 2.1.6B Page 16, Figure 4.2-1 (December 1979) n,
3) ASCO Test Report Model AQS 21678/TR R

co Present Qualification IEEE 323-1974 e

Facility: Fort Calhoun 1 Docket No.:

50-285 R4-13 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Raw Water Operating Tit 1000 hrs 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-400E, 400F, 401E 401F, 402E, 402F, 403E, 403F Tempera-ture F N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity %

N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical inlet & outlet valves for SI &

Spray N/A N/A N/A N/A N/A NONE j,

Spray pumps bearing coolers.

c3 Accuracy - Spec: N/A 5

8 Demon: N/A Radiation 2.5x10 R 2x10 R 1

2 Type Test NONE Service: See Fuaction Location: Room 69 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14.

Section 2.1.6B Page 19, Figure 4.2-4 (December 1979)

2) ASCO Test Report Model AQS 21678/TR Present Qualification 7,

to IEEE 323-1974

' E2 5;

3

~

Facility: Fort Calhoun 1 Docket No.:

50-285 R4-14 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRON 4ENT DOCIMENTATON RFF-QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi--

Qualifi-METil0D ITEMS Pa rameter cation cation cation cation System: Raw Water Operating Time 1000 hrs Continuo is Note 2 1

Type Test NONE Item No.: HCV-400E, 400F, 401E 401F, 402E, 402F, 403E, 403F Tempera-ture *F N/A N/A N/A N/A N/A NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative Model No.: EA-180 IIumidity % N/A N/A N/A N/A N/A NONE Function: Position Indication for Chemical Raw Water inlet valves to Con-Sp ray N/A N/A N/A N/A N/A NONE A

ay Spec hk 5

R 2

1 Type Test NONE Demon: N/A Radiatior.

2.5x10 R 2.04x108 Service: See Function Location: Room 69 Aging N/A Note 1 N/A Note 1 N/A NOKE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE I

Documentation

References:

Notes:

September 5, 1978

1) Switches qualified for 40 years using NAMCO recommended
1) NAMCO Test Report Model EA-180
1) " Implementation Methods and Schedules for NUREG-0578" maintenance..NAMCO letter dated 7/16/80.

Section 2.1.6B Page 19, Figu're 4.2-4 (December 1979)

2) See Enclosure #14.

Present Qualification

- on IEEE 323-1974

%8's l~

l

Facility: Fort Calhoun 1 Docket No.:

50-285 R3-3 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DONMFMT/iTON RFF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METIIOD ITEMS Pa ramet er cation cation cation cation System: Sampling System Operating Time 1000 hrs 1000 hrs Note 1 1

Tvve Test NONE Item No.: IICV-2504B, 2506B, 2507 B Tempera-ture F N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8320A189E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Sampling System Isolation Spray N/A N/A N/A N/A N/A NONE y,

.L 3;

Accuracy - Spec: N/A 5

8 Demon: N/A Radiatior 6x10 R 2.04x10 R

2 1

Type Test NONE Service: See Function Location: Room 60 Aging N/A 10 yrs N/A 1

Type Test NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) ASCO Test Report Model AQS 21678/TR
1) See Enclosure #14.
2) " Implementation Methods and Schedules for NUREG-0578" Section 2.1.6B Page 18, Figure 4.2-3 (December 1979)

Present Qualification IEEE 323-1974 R33 m

r o

Facility: Fort Calhoua 1 i

Docket No.: 50-285 R3-4 SYSTEM COMPONENT EVALUATON WORK SHEET ENVTROPfENT TWinfFMTATOM RFF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Sampling System Operating Time 1000 hrs Continuo 1s Note 2 1

Type Test NONE Item No.: HCV-2304B, 2506B, 2501 8 Tempera-ture 'F N/A N/A N/A N/A N/A NONE Component: Limit Switch Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: NAMCO Relative

~

Model No.: EA-180 Humidity % N/A N/A N/A N/A N/A NONE Function: Position Indication for Sampling System Isolation Spray N/A N/A N/A N/A N/A NONE i

valves Accuracy - Spec: N/A Demon: N/A Radiatior 6x10 R 2.04x108 5

R 2

1 Type Test NONE Service: See Function Location: Room 60 Aging N/A Note 1 N/A Note 1 N/A NONE Flood Level Elev: N/A Submer-N/A N/A NONE Above Flood Level:

gence N/A N/A N/A Documentation

References:

Notes:

1) NAMCO Test Report Model EA-180 (Ser' mber.5, 1978)
1) Switches qualified for 40 years using NAMCO recommended
2) " Implementation Methods and Schedulea for NUREG-0578" maintenance letter dated 7/16/80.

Section 2.1.6B Page 19, Figure 4.2-4 (December 1979)

2) See Enclosure #14.

Present Qualification IEEE 323-1974 5

c' 5

  • oi

~

f

Facility:

Fort Calhoun 1 Docket No.:

50-285 S-6 SYSTEM COMPONENT EVALUATON WORK SilEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-MET 110D ITEMS Parameter cation cation cation cation System: Steam Generator Feedwater Operating and Blowdown Time Note 1 1000 hrs Note 1 2

Type Test NONE Item No.: IICV-1107B & 1108B Tempera-ture F 216 F 346 F 1

2 Type Test NONE Component: Solenoid Valve #1 Pressure PSIg 1.2 psig 110 psig 1

2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP 8320A175E Humidity %

100%

1000%

1 2

Type Test NONE Function: Valve Actuators for Chemical St/ Gen RC-2A & RC-2B Aux FW Spray N/A N/A N/A N/A N/A NONE j,

inlet valves Accuracy - Spec:

N/A d

Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation of Aux. FW Lines Location: Room 81 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev:

1037.4 Submer-Above Flood Level: Yes ge'nce N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) See Enclosure #2.
1) Valves are locked open and do not operate during an
2) ASCO Test Report Model AQS 21678/TR.

event.

Present Qualification IEEE 323-1974

,m

s N

~0

Facility: Fort Calhoun 1 Docket No.:

50-285 S-7 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUttENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator Feedwater Operating and Blowdown Time Note 1 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-1107B & 1108B Tempera-ture F 216 F 346*F 1

2 Type Test NONE Component: Solenoid Valve #2 Pressure PSIg 1.2 psig 110 psig 1

2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity %

100%

100%

1 2

Type Test NONE Function: Valve Actuators for Chemical St/ Gen RC-2A & RC-2B Aux FW Spray N/A N/A N/A N/A N/A NONE os inlet valves y

Accuracy - Spec: N/A Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation of Aux FW Line :

Location: Room 81 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev:

1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) See Enclosure #2.
1) Valves are locked open and do not operate during an
2) ASCO Test Report Model AQS 21678/TR.

event.

Prescot Qualification

,j,,

IEEE 323-1974 N

3 N

Facility: Fort Calhoun 1 Docket No.:

50-285 RI-7 SYSTEM COMPONENT EVALUATON VORK SHEET ENVTRAWFNT TW1MFNT! TnM DFF' QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation ention System: Steam Generator Feedwate r and Blowdown Time 1000 hrs 1000 hrs Note 1 1

Type Test NONE Item No.: HCV-1387B & 1388B Tempera-ture F N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity % N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical St/ Gen FW and blowdown Spray N/A N/A N/A N/A N/A NONE Ly Accuracy - Spec: N/A 8

8 Demon: N/A Radiatior 4x10 R 2x10 R 2

1 Type Test NONE Service: See Function Location: Room 13 Aging N/A 10 yrs N/A 1

Type Test.

NONE Flood Level Elev: N/A Submer-Above Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) ASCO Test Report Model AQS 21678/TR.
1) See Enclosure #14.
2) " Implementation Methods and Schedules for NUREG-0578" Section 2.1.6B Page 17, Figure 4.2-1 (December 1979) 55 Present Qualification Q3 IEEE 323-1974 G

M v

Facility: Fort Calhoun 1 Docket No.: 50-285 R1-9 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.

QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Waste Disposal Time 1000 brs 1000 hrs Note 1 2

Type Test NONE Item No.: HCV-500A,B - 506A,B -

HCV-507A,B - 508A,B - 509A,B Tempera-ture *F

.N/A N/A N/A N/A N/A NONE Component: Solenoid Valve Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity %

N/A N/A N/A N/A N/A NONE Function: Valve Actuators for Chemical Wsste Disposal Spray N/A N/A N/A N/A N/A NONE i

R$

Accuracy - Spec: N/A Demon: N/A Radiation 4x10 R 2x10sR 1

2 Type Test NONE 8

Service: See Function Location: Room 13 Aging N/A 10 yrs N/A 2

Type Test NONE Flood Level Elev: N/A Submer-Above

  • Flood Level:

gence N/A N/A N/A N/A N/A NONE Documentation

References:

Notes:

1) " Implementation Methods and Schedules for NUREG-0578"
1) See Enclosure #14 Section 2.1.6B Page 17 Figure 4.2-2 (Dec. 1979)

(

l

2) ASCO Test Report Model AQS 21678/TR d$

Present Qualification j

IEEE 323-1974 m

23 R

RS 4

_