AIR MAIL August 3, 1961

/,\\yW \\ I?1/'%,

%g.Q t

/

Mr. Donald A. Nussbaumer k

3$3

(

0[ 0 Division of Licensing and Regulation 8

U. S. Atomic Energy Commission Washington 25, D. C.

~ A jy j

e s

Subject:

SNM-15h (Docket 70-lh6) 6 3

0/

\\

Dear Mr. Nussbaumer:

  1. $3I Approval is requested for a method of shipping ceramic UO2 at enrichments up t_o and including 6% U-235 The procedures here

~

are in addition to all other ap~ proved shipping methods on SEM-15h.

Experience has shown that 20 pounds per gallon of Spencer ceramic UO2 can be packaged in a shipping container.

O'n this basis, the inner containers shown in Table I for various enrichments will be used. For enrichments up to 3 9% U-235, inner containers have,been selected so that they will contain a safe mass when filled. with material at the maximum permissible enrichment. Values for safe masses were obtained from Appendix I, Figure 3, K-1019, Revision

5. For enrichments up to 6% U-235, one five-gallon pail will be used as the inner container. A five-gallon pail has.a volume of L g 92 E,155 cubic inches which is less than the safe volume for 6% enrich-l ment of 1,260 cubic' inches shown in Table XIII, K-1019, Revision 5 The three-and five-gallon pails to be used as inner containers are ICC-37A with a gasketed crimp-on lid.

The pails will be secured in the center of an ICC-17R 55-gallen drum using the steel dunnage shown in Drawing IR-1-2600-907. The drum lid has a steel pyramid attached as shown in Drawing Ut 2600-909 to prevent stacking. In the case of shipments of larger quantities of material, a steel clamp-on ring will be attached to the outside of the 55-ga11on drum hmediately above the lower chine of the drum. This ring, which is shown on Drawing IM-1-2600-908, itiereases the center-to-center spacing of the drums to 28 inches.

The haximum number of drums per shipment using'the 28 inch 0.D.

ring are shown in Case I of Table II. For smaller shipments where

& Wf l?/ /

N 8

J 4

8301200114 821214 PDR FOIA 0' -O.-

BARNES82-562 PDR

3

  • 2.

e s

USAEC August 3, 1961 Mr. Donald A. Nussbauner tha limits imposed by interaction are no' problem, the standard $$-

gallon drum (2h" O.D.) will be used. The maximum number of drums per shipment using the unmodified drum are shown under Case II in Table II.

In all cases where a safe mass is packaged in the inner containers, the maximum nunber of drums per shipment was limited to give less than 2.5 steradians. For the one case where safe volume is used as a basis for packaging, the interaction was limit-ed to 1.0 steradians. Interaction, in all cases, was calculated by the solid angle method for a close-packed hexagonal array.

To prevent. mingling of our shipment of special nuclear materials with those'of other shippers during transit, we will obtain certi-fication from the, carrier that he will not mix our shipments with any other radioactive materials.

If there are any further items that need clarification,'we request that you en11 or wire collect.

Very truly yours, Nuclear Fuels Department N. A. Greenlee NAG:cf Attachments 9

f f

~

~

d.;..l-en

e a

7o gc/d 4

TABLE I Maximum Enrichment Inner Container Nurter Inner Maximm wt/

MM mm wt/ Safe Mass

(% U-235)

(Gallone.)

Containere/ Drum Drum-(lb.UO2) Drum-(1b. U)

(1b. U) 2.2 5

2 200 176 176 2.8 3

2 120 106 106 3.0 5

1 100 88'-

88 39 3

1-60

' 53 53 5

1 100 88 Safe Volume

\\tvil N'4 ig/

.o

//.' a j.--.

',&S in "g w

~

'f de$.:s E 3 if ed.

5 ' -4

~

b N ~%

.5 5

0o sa 2

V, 3Q

\\

3

.s\\

/'4 /

/sqt\\

NFD NAG 8/3/61-9*

P

. I-

. TA[.

..; 7.n

. k *;h h y,.h'. il

7... uu.w.. -

{

' ?: -

i

~

O o

-c

~.. _.A~_ (c/g

~.

-Ml.

m TABLE II Case I Ga11on Drum with ' Attached Ring - 28" 0,D.

Maximum Number Interaction

~ Inner Containers Hurber Inner (Gallon)

Containers Basis Drums /Shipant (Steradians) 5 2,

Safe Mass 6,

2.3,7 3

2 Safe Ibss lh e.k9

-5 1

Safe Mass,

No Limit -

2.lf 5

1.

Safe Volume h

0.78 Case II - Unmodified $5-Gallon Drum - 2h" 0.D.

~

Inner Containers Number Inner

} brim = Number Interaction (Gallon)

Containers _

Basis' Drums / Shipment (Steradians) 5 2

Safe Mass k

_ 2.02 3

2 Safe Mass 6

2 39 5

1 Safe Mass 8

2.h7 3

1 Safe Mass No TAmit, 2.2h 5