05000285/LER-1981-006-03, /03L-0:on 810624,reactor Protection Sys Nuclear Power Recorder Channel B Trip Setpoints Determined to Be Nonconservative.Caused by Faulty Temp Change Power Calculation Due to Grounded Hot Leg Temp Loop
| ML20010C227 | |
| Person / Time | |
|---|---|
| Site: | Fort Calhoun |
| Issue date: | 07/07/1981 |
| From: | Mueller R OMAHA PUBLIC POWER DISTRICT |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| Shared Package | |
| ML20010C224 | List: |
| References | |
| LER-81-006-03L, LER-81-6-3L, NUDOCS 8108190264 | |
| Download: ML20010C227 (4) | |
| Event date: | |
|---|---|
| Report date: | |
| 2851981006R03 - NRC Website | |
text
t.hcrOH?h$1 U. S. e'1UCLE AR HEGUL A TORY COMMISSION u,.n.
LICENSEE EVEilT REPORT con rMOL 6LCCM. l l
l l
l l
l (PLE ASE PRINT Ca TYPE ALL HEQUIRED INFOHMATIOfD lo i tj lN I E ! F l C ' S l lj@l 010 l 0 l 0 l 0 l 0 l 0 ! 0 l 0 l 0 l 0 l@l4 l1 l1 l1 l1 l@{
l I@
l u
.}
(
- 4
's Lt L t '.
f 4Wbt ~
.5 en U C L N.a c. ivPE ad
$/ L A T 3d CD'4'T [alil
"[."l l L ]l O ! SJ 0 l 0 ! 0 l 2 l 8 l 5 }@l 016 l 2 14 l 8 l lj@l 017 ! 017 18 II I@
i e;
t. t r,L4EINr%Ea os 04 t. Y t N T D A T E 74 O
PEPOR T DATE B0 te:Nr cr ;cnia no. c.No enOB ABLE CoNCCCUENCCC h [o I l l The "B" Channel Nuclear Power Recorder decrRagsd_applarximately 30% in_ power._levol I
gg ;(as opposed to the remaining 3 channels).
"B" channels Thot decreased to approx. 507 l
[.g [f rom the normal operating temperature of 588 F.
The $T power level dropped approx. 15%]
l
!3, from its normal reading (and the readings of the remaining three channels).
In additiot},
l iT] @" Subcooled MarQn Monitor went into alarm. The reactor was operating at approx. 94%1 [FTTl ! power at the time _. The RPS was subsequently placed in a two-out-of-three logic to tripi g,-~] modes (i.e., "B" channel was placed in bypass).
]
o
"', T E '1 C, ' :T
' A '/,E CO*'P VALVE
.ll ME TL't OLM CO*"
- tNTCOGE SU3CCDE EUSCOCh E5 1 1 I A,j h [Ejh l A lh l Il Nl Sl Tl Rl Ulh l E lh [Zj h j) 11 11 13 14 13
.)
- N E '4 i ' A t O'O;n4fhCE 9EFORT REvlstON s t.,7 q a n HE POH T N o.
CCOE TYPE NO.
,J,.
18 11 )
[d [01016I L.d.
I0131 ILI l, l lol i
i n
n n
w 2
u r
- - f f f f' T
.u ; f ; b..N ATT ACH9f N T NPFC 4 PRIME GCVP.
COMPONENT W
f'"2 P L A N T
?.* F T H 'M HOUH$
dt.,ti til TT ( O F QH M, Uti SUPPUf H P.i ANL F AC TUR F R IE {jlZ]@
lZ{@
l Z l@
[ 01 0l 0] 0l lYl@
l N l@
l N j@
l Cl 4 l 9 l 0l@
F I/
40 41 42 4j 44 47 A4),C ff C hil' Tl ON AN D L O!3 f'E '_' TIV E ACTIONS [M l After troubleshooting the "B" channel RPS, it was discovered that nrounds at two 1
[Ti--] LPo i n t s in the current loop _B/122-Il has caused alternate current paths to the Subqngled1 j,l,l l Margin Monitor and RPS indication and the resultant erroneous "B" channel readings.
i gg l The grounds were isolated / removed and the af fected 1 oops recalibrated. Applicable LiI$1 l portions of Surveillance Test ST-RPS-4 were also performed and "B" channel was returned to operability.
sa i
s i
'U' oTor n u ues (,?)
E'$SM oisem e nv oEsCntPTion h
.o [t l l [E,,J@ l 0_ l 9 l 4 l(}l NA l
l A l@l Operator Investigation l
dm.. T.
o'.M y,
vnia vimTv b l t c:uioN or set EASE h oirAe tw or u ^..
[@j[Z_j(J {l@l NA l
NA l
,'1 44 4 ';
8d l
4 P$-
' 4 [.
t i R' ;. '
., ( m)
- - n.
.w n
! ' ! I l_0 [0 l0 j(l')y31
~
NA l
"J j'm'.,,
w. n m. (,u)
!' l j l0 j0 10 !@l NA~
l e
o sa 8
i'A t
')eA< i,!!
(J
..o
.s [t l 'l [Z jhl l
NA c
$n.PinNh N RC USE ON L V r.o
[.loj LjQt[___ NA _
l lIllIlll1l l!lI 8100190264 810724
" 5 PDR ADOCK 05000285 Randy J. Mueller (402) 426-4011 E
s PDR g
,g gy g.
o
LER No.81-006 Omaha Public ?ower District Fort Calhoun Station Unit No. 1 Docket No. 05000285 Attachment No. 1
Safety Analysis
The trip setpoints of "B" channel RPS units corresponding to High Power Level, Thermal Margin / Low Pressure, and a::ial power distribution were determined to be non-cor.cervative due to a faulty "B" channel 4T power calculation. This AT power calculation was in error due to a grounded "B" channel llot leg temperature loop. Thus, the "B" channel of the RPS was bypassed. During the time "B" channel was bypassed, the remaining channels "A", "C" and "D" - were operable and fully capable of performing their intended purpose, that is, to safely shutdown the reactor, should the need have arisen.
During the time the "B" subccoled Margin Monitor was in alarm (corresponding to the temperature side only) the "B" Subcooled Margin Monitor pressure loop remained operable as did the "A" Subcooled Margin Monitor temperature and pressure loop, a
f' Y
S
/bY:
LER No.81-006 Omaha Public Power District Fort Calhoun Station Unit No. 1 Docket NO. 05000285 Attachment No. 2
Corrective Action
Upon inspection of "B" Chant.ul (RPS) abnormalities it was deter-mined that the "B" hot leg temperature channel had been grounded at the transmitter TT/B-122H.
In addition, the "B" channel Nuclear Power Recorder (which is fed via a signal from the "B" hot leg temperature loop and the "B" channci Linear Power Drawer) also had a ground at or near the Nuclear Power recorder. As a result of the dual ground, an alternate current path between the "B" hot leg temperature loop, the linear power drawer and the Nuclear Power Recorder was created. As a result of this alternate current path, the normal signal which feeds into the RPS (and more specifically, the dT power calculator) was interrupted, thus causing the liigh Power Level Thermal Margin / Low Pressure and Axial Power Distribution trip units to fail non-conser-vatively.
The grounds were isolated and repaired / alleviated via work per-formed on Maintenance Order #10647. The affected "B" channels were recalibrated and applicable sections of Surveillance Test ST-RPS-4 were performed. The loop B-122/H was thus returned to oberability and the "B" channel RPS taken out of bypass.
p]
I L _ _ _ _ _ _ _ _ _ _ _. _ _ _
+ *.
LER No.81-006 Omaha Public Power Di.attict Fort Calhoun Static.: Unit No. 1 Docket No. 05000285 Attechment Nn, 3 Failure Data This is the first occurrence of this type at the Fort Calhoun Station Unit No. 1.
/
i e