LER-1981-006, Forwards LER 81-006/03L-0 |
| Event date: |
|
|---|
| Report date: |
|
|---|
| 2851981006R00 - NRC Website |
|
text
. _ _ _ _ _ _ _ _ _ _ _ _ _ _
Omaha Public Power District 1623 HARNEY e OMAHA, NEBRAGMA 68102 m TELEPHONE S36 4000 AREA CODE 402 July 24, 1981 FC-430-81 Mr. K. V. Seyfrit U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011
Dear Mr. Seyfrit:
Reference:
Fort Calhoun Station Unit No. 1 Docket No. 05000285 In accordance with the Fort Calhoun Station's Technical Specifica-tions, the Omaha Public Power District, as holder of facility operating license DPR-40, submits three copies of licensee event report 81-006, (regarding Technical Specification 5.9.2.b.(1)) to satisfy requirements of Regulatory Guide 1.16.
Sincerely, ll l:b l,1.jlp t%'l]
William C. Jones Divisio'n Manager Production Operations "l)19 WCJ/RLA/SCS:Jbk
/ /, C)
S Enclosures
\\
y cc: Director, Office of Management 1 Gv. ph ' h E
(
g"
- - t Information and Program Control 1
U. S. Nuclear Regulatory Commission E
'[- '
I s
Washington, DC 20555 (3)
O o *'
D
/s)
Director, Office of Inspection and
' _'f g j i Enforcement U. S. Nuclear Regulatory Commission f
Washington, DC 20553 (30)
[C 5
Nuclear Safety Analysis Center
/ /
Mr. R. L. Andrews SARC Chairman PRC Chairman Fort Calhoun File (2)
Mr. Dennis Kelley NRC Senior Resident Inspector
~f 8108190261 810724 PDR ADOCK 05000285 IL21
,,,to,o m r.,r u ou.c o, o,,ru 1,
mi. s eon
-.a
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000285/LER-1981-001, Forwards LER 81-001/01T-0 | Forwards LER 81-001/01T-0 | | | 05000285/LER-1981-001-01, /01T-0:on 810114,discovered That FT-236 Changing Header Flow Lacks Complete Info to Qualify for Harsh Radiation Svc Required by IE Bulletin 79-01B.Caused by Incomplete Matls List.Transmitter Will Be Replaced | /01T-0:on 810114,discovered That FT-236 Changing Header Flow Lacks Complete Info to Qualify for Harsh Radiation Svc Required by IE Bulletin 79-01B.Caused by Incomplete Matls List.Transmitter Will Be Replaced | | | 05000285/LER-1981-002, Forwards LER 81-002/01T-0 | Forwards LER 81-002/01T-0 | | | 05000285/LER-1981-002-01, /01T-0:on 810413,during Normal Operation at 65% Power,Notification Received of Defect in Certain Foxboro Transmitters.Transmitters Have Capacitor Amplifier Which May Fail Due to Heat During Operation or After LOCA | /01T-0:on 810413,during Normal Operation at 65% Power,Notification Received of Defect in Certain Foxboro Transmitters.Transmitters Have Capacitor Amplifier Which May Fail Due to Heat During Operation or After LOCA | | | 05000285/LER-1981-003, Forwards LER 81-003/01T-0 | Forwards LER 81-003/01T-0 | | | 05000285/LER-1981-003-01, /01T-0:on 810428,MSIVs HCV-1041A/HCV-10242A Failed Closed Upon Loss of All 125 Volt Dc Power Feeding Bus A1-41B.Caused by Damaged Cable on 100 Amp Switch.Switch & Cable Replaced.All Breaker Panel Lugs Checked for Tightness | /01T-0:on 810428,MSIVs HCV-1041A/HCV-10242A Failed Closed Upon Loss of All 125 Volt Dc Power Feeding Bus A1-41B.Caused by Damaged Cable on 100 Amp Switch.Switch & Cable Replaced.All Breaker Panel Lugs Checked for Tightness | | | 05000285/LER-1981-004-01, /01T-0:on 810430,personnel Air Lock Door Seals Leak Rate Exceeded Allowable Rate.Caused by Mechanical Door Seals Not Sealing Properly.Seals Repaired | /01T-0:on 810430,personnel Air Lock Door Seals Leak Rate Exceeded Allowable Rate.Caused by Mechanical Door Seals Not Sealing Properly.Seals Repaired | | | 05000285/LER-1981-004, Forwards Revised Attachment 3 to LER 81-04 Re Tech Spec 2.01.Since startup,34 Maint Orders Written on Single Pal Door Seal Failures | Forwards Revised Attachment 3 to LER 81-04 Re Tech Spec 2.01.Since startup,34 Maint Orders Written on Single Pal Door Seal Failures | | | 05000285/LER-1981-005-03, /03L-0:on 810423,dc Sequencer Timers AC-3A (Component Cooling Water Pump) & AC-102A (Raw Water Pump) Failed to Time Out within Prescribed Limit.Cause Unknown Mechanisms Satisfactorily Inspected | /03L-0:on 810423,dc Sequencer Timers AC-3A (Component Cooling Water Pump) & AC-102A (Raw Water Pump) Failed to Time Out within Prescribed Limit.Cause Unknown Mechanisms Satisfactorily Inspected | | | 05000285/LER-1981-005, Forwards LER 81-005/03L-0 | Forwards LER 81-005/03L-0 | | | 05000285/LER-1981-006-03, /03L-0:on 810624,reactor Protection Sys Nuclear Power Recorder Channel B Trip Setpoints Determined to Be Nonconservative.Caused by Faulty Temp Change Power Calculation Due to Grounded Hot Leg Temp Loop | /03L-0:on 810624,reactor Protection Sys Nuclear Power Recorder Channel B Trip Setpoints Determined to Be Nonconservative.Caused by Faulty Temp Change Power Calculation Due to Grounded Hot Leg Temp Loop | | | 05000285/LER-1981-006, Forwards LER 81-006/03L-0 | Forwards LER 81-006/03L-0 | | | 05000285/LER-1981-007, Forwards LER 81-007/03L-0 | Forwards LER 81-007/03L-0 | | | 05000285/LER-1981-007-03, /03L-0:on 810706,discovered That Diesel Generator DG-1 Had Not Started Despite Indications of Attempted Starts.Caused by Faulty Speed Sensing Control Unit.Speed Sensing Unit Replaced | /03L-0:on 810706,discovered That Diesel Generator DG-1 Had Not Started Despite Indications of Attempted Starts.Caused by Faulty Speed Sensing Control Unit.Speed Sensing Unit Replaced | | | 05000285/LER-1981-008-03, /03L-0:on 810813,86B/CRHS (Containment Radiation High Signal) Lockout Relay Failed to Actuate When RM-062 Was Placed in Alarm,Resulting in Failure of 86B1/CRHS Relay to Actuate.Caused by Dirt in Relay Latching Mechanism | /03L-0:on 810813,86B/CRHS (Containment Radiation High Signal) Lockout Relay Failed to Actuate When RM-062 Was Placed in Alarm,Resulting in Failure of 86B1/CRHS Relay to Actuate.Caused by Dirt in Relay Latching Mechanism | | | 05000285/LER-1981-008, Forwards LER 81-008/03L-0 | Forwards LER 81-008/03L-0 | | | 05000285/LER-1981-009-03, /03L-0:on 810924,during Shutdown,Cooling Fan/Coil Placed in Svc for Containment Air Cooling.Pressurized Leak Developed When Coil End Plug Blew Out.Caused by Stripped Threads on Loosely Installed Thread End Plug | /03L-0:on 810924,during Shutdown,Cooling Fan/Coil Placed in Svc for Containment Air Cooling.Pressurized Leak Developed When Coil End Plug Blew Out.Caused by Stripped Threads on Loosely Installed Thread End Plug | | | 05000285/LER-1981-009, Forwards LER 81-009/03L-0 | Forwards LER 81-009/03L-0 | | | 05000285/LER-1981-010-03, /03L-0:on 811027,D/LC-383-1 Left & Right Switches & D/LC-383-2 Left & Right Switches Found Out of Setpoint Tolerances.Caused by D Channel Level Switches Drifting Out of Calibr for Unknown Reasons.Switches Recalibr | /03L-0:on 811027,D/LC-383-1 Left & Right Switches & D/LC-383-2 Left & Right Switches Found Out of Setpoint Tolerances.Caused by D Channel Level Switches Drifting Out of Calibr for Unknown Reasons.Switches Recalibr | | | 05000285/LER-1981-010, Forwards LER 81-010/03L-0 | Forwards LER 81-010/03L-0 | | | 05000285/LER-1981-011, Forwards LER 81-011/03L-0 | Forwards LER 81-011/03L-0 | | | 05000285/LER-1981-011-03, /03L-0:on 811113,containment Isolation Valves Opened & Ventilation Process Initiated W/Containment Air Monitor RM-050/051 Inoperable.Caused by Personnel Error. Valves Closed | /03L-0:on 811113,containment Isolation Valves Opened & Ventilation Process Initiated W/Containment Air Monitor RM-050/051 Inoperable.Caused by Personnel Error. Valves Closed | |
|