05000321/LER-1981-053-03, /03L-0:on 810610,drywell & Torus Temp Recorder 1T47-R612 Found Marking Erratically.Caused by Component Failure Due to Balancing Motor Failure.Component Replaced

From kanterella
(Redirected from ML20009F548)
Jump to navigation Jump to search
/03L-0:on 810610,drywell & Torus Temp Recorder 1T47-R612 Found Marking Erratically.Caused by Component Failure Due to Balancing Motor Failure.Component Replaced
ML20009F548
Person / Time
Site: Hatch 
Issue date: 07/02/1981
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20009F546 List:
References
LER-81-053-03L-01, LER-81-53-3L-1, NUDOCS 8107310292
Download: ML20009F548 (2)


LER-1981-053, /03L-0:on 810610,drywell & Torus Temp Recorder 1T47-R612 Found Marking Erratically.Caused by Component Failure Due to Balancing Motor Failure.Component Replaced
Event date:
Report date:
3211981053R03 - NRC Website

text

U. S. NUCLEAR REGULATORY COMMISSION NRC FOnM 366 (747)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFCRMATION) 1 6

lo l1l l Gl Al El Il Hl Il@l 0 I 0l -l 0 l 0 l 0 l O l 0 l - l 0 l O l@l 4 l 1 l 1 l 1 l 1 l@l l

l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUMSER 25 26 LICENSE TYPE JO 5 7 CA T $8 CON'T LoJW S UR% dl 015101 o ! 013121 i l@l 01611101 A l 1 l@l01710l2I8Ill@

1 -

8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 76 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h l o 121 l While the plant was in start-up and hot standbv.1T47-R612. Drvwell and l

FTT G I Torus Temperature Recorder was found to be marki..g erratically.

Tech I

lot 4l l Specs Table 3.2-11 requires two operable channels.

Re'Jundant recorder, l

[Tm l 1T47-R611, was operable.

Plant operation was placed in a 30 day LC0 as l

l0 !s) I a result of this event.

The health and safety of the public was not i

Io l7I I affected.

This is a repetitive event as last reported on Reportable l

l o is i i Occurrence Report No. 50-321/1981-005.

I DE COCE SUBCO E COMPONENT CODE SUSC DE SU E

iTITl l Il Dl@ l El@ l B l@ lI I N l S l T l R l U l@ W@ J @

7 8

9 10 11 12 13 18 19 20 SEQUENTI AL OCCURRENCE REPORT REVISION LER RO EVENT YEAR REPORT NO.

CODE TYPE NO.

@ yghaT - 18111 l-l l0l5l31 y

10 l 3 l l Ll

[_-j l0 l a

Lu n

n 24 2.

27 2.

2, s.

v u

^S*KTN T

AC 0 ON PL NT YE HOURS S B ITT FO B.

SUP Li M A ** FACTURER l_A,j@(_Z,,j@

l_lj@

l_Lj@

l0l0l0l0l l Y l@

lNl@

l_N,4_j @ lTl0l3l9l@

33 34 35 36 3/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS liloIl The cause of this event has been attributed to component failure.

The I

li ti i I failure was due to balancino motor failure.

The component was replaced I

li12i I and returned to service.

The unit is now in full compliance.

I I

liial l l

l i 14 I l 80 7

8 3 STA

% POWER OTHER STATUS DIS O ' RY DISCOVERY DESCRIPTION I1 l5 l l El@ l 0 l 0 l 1 l@l NA l

lBl@l Operator Observation l

ACTIvlTY CO TENT RELEASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE W l Zl @ [,_Z_j @ l NA l

l NA l

PERSONNEL EXPOS ES NUVBER TYPE

DESCRIPTION

ITTil l 01 0l Ol@l Z l@l NA l

PERsONNE t iN;uYiES NUMBER

DESCRIPTION

W l 0l 0l 0l@l NA l

80 7

8 9 11 12 LOSS OF OR DAMAGE TO FACILITY TYPE

DESCRIPTION

y l Zl @ l NA i

metisTY 8107310292 810702 NRc USE ONLY PDR ADOCK 05000321 M hsSuE.@loESCRipS PDR IA l

lllllllllllllj 68 69 80 ;

7 8 3 10 J-M7-7781 R

4 LER No.: 50-321/1981-053 Licensee: Georgia Power Company Facility:

Edwin I. Hatch Docket No. :

50-321

Narrative

Report for LER 50-321/1981-053.

While the plant was in start-up and hot standby,1T47-R612, Drywell and Torus Teinperature Recorder, was found to be marking erratically.

Tech Specs Table 3.2-11, Item 5, requires two operable channels.

Redundant recorder, IT47-R611, was operable.

Plant operation was placed in a 30 day LC0 as a result of this event.

The health and safety of the public was not affected.

This event was repetitive as last reported on Reportable Occurrence Report No. 50-321/1981-005.

The cause of this event has been attributed to component failure.

The i l Te$ilure was due to balancing motor failure.

The component was replaced and retu,rned to service.

The unit is now in full compi Lance.

A generic review rcvealed no inherent prcblems. This particular failure mode has not been. evident before.

This type of Taylor recorder is not used on Hatch, Unit II.

\\

i