| | | Reporting criterion |
|---|
| 05000321/LER-1986-001, :on 860101,w/unit Shut Down for Scheduled Refueling Outage,Reactor Water Conductivity Sample Not Taken.Caused by Personnel Error.Other Specified Conductivity Samples Taken & Satisfactorily Analyzed |
- on 860101,w/unit Shut Down for Scheduled Refueling Outage,Reactor Water Conductivity Sample Not Taken.Caused by Personnel Error.Other Specified Conductivity Samples Taken & Satisfactorily Analyzed
| 10 CFR 50.73(a)(2)(1) |
| 05000366/LER-1986-001-01, :on 860110,RWCU Sys Outboard Primary Containment Isolation Valve 2GB1-F00t Isolated Due to Blown Fuse.Caused by Normal Wear of Sliding Disconnect Bolt Threads on Electrical Link ccc-2 |
- on 860110,RWCU Sys Outboard Primary Containment Isolation Valve 2GB1-F00t Isolated Due to Blown Fuse.Caused by Normal Wear of Sliding Disconnect Bolt Threads on Electrical Link ccc-2
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-002, :on 860115,RWCU Primary Containment Inboard & Outboard Suction Isolation Valves 2G31-F001 & 2G31-F004 Isolated on High Sys Differential Flow.Caused by Personnel Error.Personnel Counseled.Valve Repaired |
- on 860115,RWCU Primary Containment Inboard & Outboard Suction Isolation Valves 2G31-F001 & 2G31-F004 Isolated on High Sys Differential Flow.Caused by Personnel Error.Personnel Counseled.Valve Repaired
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-002-01, :on 860106,circuitry for 4,160 Volt Auto Bus Transfer Discovered Not Tested According to Tech Spec Requirements.Caused by Misunderstanding of Tech Specs.New Surveillance Guide Written |
- on 860106,circuitry for 4,160 Volt Auto Bus Transfer Discovered Not Tested According to Tech Spec Requirements.Caused by Misunderstanding of Tech Specs.New Surveillance Guide Written
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2) |
| 05000321/LER-1986-002, :on 860106,determined That 4,160-volt Auto Bus Transfer Circuitry Not Tested Per Tech Spec Requirements. Caused by Inadequate Procedure 42SV-R43-00-1-1 Re Alternate Supply Breaker Testing.Procedure Revised |
- on 860106,determined That 4,160-volt Auto Bus Transfer Circuitry Not Tested Per Tech Spec Requirements. Caused by Inadequate Procedure 42SV-R43-00-1-1 Re Alternate Supply Breaker Testing.Procedure Revised
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(1) |
| 05000366/LER-1986-002-01, :on 860115,RWCU Isolation Valves Discovered Isolated on High Sys Differential Flow.Caused by Personnel Error When Drain Valve Not Properly Closed Prior to Placing Loop a of RWCU in Svc |
- on 860115,RWCU Isolation Valves Discovered Isolated on High Sys Differential Flow.Caused by Personnel Error When Drain Valve Not Properly Closed Prior to Placing Loop a of RWCU in Svc
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-003, :on 860119,Group 1 Actuation Occurred Causing MSIV Closure & Reactor Scram.Caused by High Turbine Bldg Temp Condition & Failure of Three Mode Switch Contracts. RCIC Sys Recalibr.Amplifier Replaced |
- on 860119,Group 1 Actuation Occurred Causing MSIV Closure & Reactor Scram.Caused by High Turbine Bldg Temp Condition & Failure of Three Mode Switch Contracts. RCIC Sys Recalibr.Amplifier Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-003-01, :on 860128,high Drywell Pressure Signal Caused Several ESF Actuations to Occur During Hydrostatic/Pneumatic Test H-64.Caused by Personnel Error.Personnel Counseled & Incident Reviewed |
- on 860128,high Drywell Pressure Signal Caused Several ESF Actuations to Occur During Hydrostatic/Pneumatic Test H-64.Caused by Personnel Error.Personnel Counseled & Incident Reviewed
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-004, :on 860131,62-day Surveillance Requirement for Fire Detector Alarms Not Met.Caused by Personnel Oversight Resulting in Procedural Deficiency.Procedure 425V-SUV-015-25 Revised |
- on 860131,62-day Surveillance Requirement for Fire Detector Alarms Not Met.Caused by Personnel Oversight Resulting in Procedural Deficiency.Procedure 425V-SUV-015-25 Revised
| 10 CFR 50.73(a)(2)(1) |
| 05000366/LER-1986-005, :on 860327,RWCU Sys Isolation Occurred Due to Stuck Filter/Demineralizer Valve 2G31-F056B When Isolation Control Switch in Deisolate Position.Cause Not Found.Damaged Rcwu Sys Valves Repaired |
- on 860327,RWCU Sys Isolation Occurred Due to Stuck Filter/Demineralizer Valve 2G31-F056B When Isolation Control Switch in Deisolate Position.Cause Not Found.Damaged Rcwu Sys Valves Repaired
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-005, :on 860130,during Refueling Outage,Esf Actuation Occurred.Caused by Reactor Protection Sys a Alternate Power Supply Bus Trip Due to Voltage Fluctuations. Voltage Regulator Will Be Installed |
- on 860130,during Refueling Outage,Esf Actuation Occurred.Caused by Reactor Protection Sys a Alternate Power Supply Bus Trip Due to Voltage Fluctuations. Voltage Regulator Will Be Installed
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-005-01, :on 860327,while Placing Filter/Demineralizer in Svc,High Differential Flow Occurred,Causing RWCU Isolation.Cause Unknown.Investigation Will Be Performed to Determine Root Cause |
- on 860327,while Placing Filter/Demineralizer in Svc,High Differential Flow Occurred,Causing RWCU Isolation.Cause Unknown.Investigation Will Be Performed to Determine Root Cause
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-006, :on 860115,full Reactor Protection Sys Logic Actuation Occurred from Spurious Reactor Low Water Level Instrumentation Signal.Caused by Contract Work in Area. Control Rods in Place Prevented Reactor Scram |
- on 860115,full Reactor Protection Sys Logic Actuation Occurred from Spurious Reactor Low Water Level Instrumentation Signal.Caused by Contract Work in Area. Control Rods in Place Prevented Reactor Scram
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-006-01, :on 860320,hydraulic Shock & Sway Arrestor Insp & Test Procedure Determined Inadequate,Per Tech Spec Section 4.7.4.b.Caused by Failure to Revise Procedure After License Amend |
- on 860320,hydraulic Shock & Sway Arrestor Insp & Test Procedure Determined Inadequate,Per Tech Spec Section 4.7.4.b.Caused by Failure to Revise Procedure After License Amend
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(1) |
| 05000321/LER-1986-007-01, :on 860331,standby Gas Treatment Filter Train 1A Found Degraded by Wet Downstream Charcoal Absorber Bed. Caused by Personnel Failure to Recognize Potential Leaking Deluge Valve.Charcoal Bed Replaced |
- on 860331,standby Gas Treatment Filter Train 1A Found Degraded by Wet Downstream Charcoal Absorber Bed. Caused by Personnel Failure to Recognize Potential Leaking Deluge Valve.Charcoal Bed Replaced
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(1) |
| 05000366/LER-1986-007, :on 860213,HPCI Steam Supply Outboard Isolation Valve 2E41-F002 Isolated Due to Unplanned Isolation Signal from Differential Pressure Transmitter.Caused by Defective Procedure.New Procedure Written |
- on 860213,HPCI Steam Supply Outboard Isolation Valve 2E41-F002 Isolated Due to Unplanned Isolation Signal from Differential Pressure Transmitter.Caused by Defective Procedure.New Procedure Written
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-008-01, :on 860218,ESF Actuation Occurred.Caused by High RWCU Sys Differential Flow Due to Filter/Demineralizer Isolation Valves Opening Too Quickly When Manually Assisted During Maint.Engineering Review Underway |
- on 860218,ESF Actuation Occurred.Caused by High RWCU Sys Differential Flow Due to Filter/Demineralizer Isolation Valves Opening Too Quickly When Manually Assisted During Maint.Engineering Review Underway
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-009, :on 860207,standby Gas Treatment (SBGT) Sys Fans for Train a of Units 1 & 2 auto-started.Caused by Blown Fuse in Supply Circuit to LOCA Signal to SBGT Relay C61-K72. Fuse Replaced |
- on 860207,standby Gas Treatment (SBGT) Sys Fans for Train a of Units 1 & 2 auto-started.Caused by Blown Fuse in Supply Circuit to LOCA Signal to SBGT Relay C61-K72. Fuse Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-009-01, :on 860420,moisture Separator Reheater a High Level Trip Actuated,Tripping Main Turbine & Resulting in Reactor Scram.Caused by Failure of Level Switch Due to Moisture from Leaking Valve |
- on 860420,moisture Separator Reheater a High Level Trip Actuated,Tripping Main Turbine & Resulting in Reactor Scram.Caused by Failure of Level Switch Due to Moisture from Leaking Valve
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-010-01, :on 860424,relay Actuated,Tripping Main Turbine Which Resulted in Reactor Scram.Caused by Steam Leak.All Moisture in Exciter Equipment Removed,Failed Pipe Sections Replaced & Expanded Investigations Initiated |
- on 860424,relay Actuated,Tripping Main Turbine Which Resulted in Reactor Scram.Caused by Steam Leak.All Moisture in Exciter Equipment Removed,Failed Pipe Sections Replaced & Expanded Investigations Initiated
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-011, :on 860213,ESF Actuated W/Unit Shut Down for Refueling.Caused by Nonutility Personnel Error During Temporary Mod.Mod Work Instructions Rewritten to Isolate Transmitters from Trip Units |
- on 860213,ESF Actuated W/Unit Shut Down for Refueling.Caused by Nonutility Personnel Error During Temporary Mod.Mod Work Instructions Rewritten to Isolate Transmitters from Trip Units
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-011-01, :on 860425,component Failures Prevented 4 H Grab Sampling.Iodine/Noble Gas Sample Sys Inoperable Due to Blown Power Fuse.Particulate Sample Sys Inoperable Due to Sys Vacuum Pump Failure |
- on 860425,component Failures Prevented 4 H Grab Sampling.Iodine/Noble Gas Sample Sys Inoperable Due to Blown Power Fuse.Particulate Sample Sys Inoperable Due to Sys Vacuum Pump Failure
| 10 CFR 50.73(a)(2)(1) |
| 05000321/LER-1986-012, :on 860226,discovered That Thermal Sensor 1C11-N060A Valved Out & Inoperable.Caused by Personnel Error.Isolation Valve for Sensor Opened & Channel Returned to Svc |
- on 860226,discovered That Thermal Sensor 1C11-N060A Valved Out & Inoperable.Caused by Personnel Error.Isolation Valve for Sensor Opened & Channel Returned to Svc
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(1) |
| 05000366/LER-1986-012-01, :on 860628,feedwater Flow Loss Resulted in Reactor Scram & Isolation of Primary Containment Valves on Low Water Level.Caused by Failure of Flow Control Valve (2N21-F007).Pneumatic Relay Assembly Replaced |
- on 860628,feedwater Flow Loss Resulted in Reactor Scram & Isolation of Primary Containment Valves on Low Water Level.Caused by Failure of Flow Control Valve (2N21-F007).Pneumatic Relay Assembly Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-013-01, :on 860701,suppression chamber-to-drywell Vacuum Breaker Not Demonstrated Operable within 2 H of Discharge of Steam from Safety/Relief Valves to Suppression Chamber.Caused by Personnel Error.Memo Issued |
- on 860701,suppression chamber-to-drywell Vacuum Breaker Not Demonstrated Operable within 2 H of Discharge of Steam from Safety/Relief Valves to Suppression Chamber.Caused by Personnel Error.Memo Issued
| 10 CFR 50.73(a)(2)(1) |
| 05000321/LER-1986-013, :on 860305,w/unit in Refueling Mode & During Hydrostatic Test on RWCU Filter/Demineralizer B,Rwcu Sys Isolation Occurred.Cause Undetermined.No Corrective Actions Planned |
- on 860305,w/unit in Refueling Mode & During Hydrostatic Test on RWCU Filter/Demineralizer B,Rwcu Sys Isolation Occurred.Cause Undetermined.No Corrective Actions Planned
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-014-01, :on 860717 HPCI Sys Inoperable Due to HPCI Turbine Failure to Achieve Rated Speed.Caused by Hydraulic Turbine Control Valve Not Opened Fully Because Rag Blocked Pump.Pump Replaced |
- on 860717 HPCI Sys Inoperable Due to HPCI Turbine Failure to Achieve Rated Speed.Caused by Hydraulic Turbine Control Valve Not Opened Fully Because Rag Blocked Pump.Pump Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-015, :on 860331,isolation of RHR Reactor Shutdown Cooling Suction Inboard Primary Containment Isolation Valve 1E11-F009 Occurred.Caused by Inadequate Procedure.Procedure 57SV-SUV-007-1S Will Be Revised |
- on 860331,isolation of RHR Reactor Shutdown Cooling Suction Inboard Primary Containment Isolation Valve 1E11-F009 Occurred.Caused by Inadequate Procedure.Procedure 57SV-SUV-007-1S Will Be Revised
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-016, :on 860404,reactor Protection Sys Logic Actuation Occurred.Caused by Main Steam Line Radiation Monitor Failing Downscale.Monitor Repaired by Adjusting High Voltage Inoperable Trip Setpoint |
- on 860404,reactor Protection Sys Logic Actuation Occurred.Caused by Main Steam Line Radiation Monitor Failing Downscale.Monitor Repaired by Adjusting High Voltage Inoperable Trip Setpoint
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-016-01, :on 860807,nine Primary Containment Manual Valves Found Not Receiving Procedurally Controlled Position Checks.Caused by Inadequate Procedure.Surveillance Performed.Procedure Modified to Include Valves |
- on 860807,nine Primary Containment Manual Valves Found Not Receiving Procedurally Controlled Position Checks.Caused by Inadequate Procedure.Surveillance Performed.Procedure Modified to Include Valves
| 10 CFR 50.73(a)(2)(i) |
| 05000321/LER-1986-017, :on 860415,LPCI Outboard Primary Containment Isolation Valve Isolated Causing Shutdown Cooling Capability Loss.Caused by Blown Fuses from Inadvertent Short of Relay Contacts Due to Personnel Error.Valve Reopened |
- on 860415,LPCI Outboard Primary Containment Isolation Valve Isolated Causing Shutdown Cooling Capability Loss.Caused by Blown Fuses from Inadvertent Short of Relay Contacts Due to Personnel Error.Valve Reopened
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(1) |
| 05000366/LER-1986-017-01, :on 860915,RCIC Inboard Primary Containment Isolation Sys Valve Closed for No Apparent Reason.Caused by Spurious Electrical Noise.Valve Reopened |
- on 860915,RCIC Inboard Primary Containment Isolation Sys Valve Closed for No Apparent Reason.Caused by Spurious Electrical Noise.Valve Reopened
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-018-01, :on 860810,RWCU Sys Isolated on High Differential Flow Signal.Caused by RWCU Resin Trap Not Being Filled & Vented Prior to Placing Sys in Svc or Resin Trap Isolation Valves Being Open.Procedure Modified |
- on 860810,RWCU Sys Isolated on High Differential Flow Signal.Caused by RWCU Resin Trap Not Being Filled & Vented Prior to Placing Sys in Svc or Resin Trap Isolation Valves Being Open.Procedure Modified
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-018, :on 860521,reactor Scrammed on MSIV Not Fall Open Signal Due to Group I Valve Isolation.Caused by Steam Leak Around Packing of Main Steam Line Drain Valve 1N11-F019.Valve Repaired |
- on 860521,reactor Scrammed on MSIV Not Fall Open Signal Due to Group I Valve Isolation.Caused by Steam Leak Around Packing of Main Steam Line Drain Valve 1N11-F019.Valve Repaired
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-018, :on 860810,RWCU Isolated on High Differential Flow Signal.Caused by Failure to Fill & Vent RWCU Resin Trap &/Or Resin Trap Isolation Valves Being Partially Open. Demineralization Procedure & Valves Modified |
- on 860810,RWCU Isolated on High Differential Flow Signal.Caused by Failure to Fill & Vent RWCU Resin Trap &/Or Resin Trap Isolation Valves Being Partially Open. Demineralization Procedure & Valves Modified
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-019, :on 860413,revised Core Spray Logic Sys Functional Test Procedure Found Inadequate.Caused by Procedure Possibly Rendering Diesel Generators 1A & C Inoperable.Procedure Revised |
- on 860413,revised Core Spray Logic Sys Functional Test Procedure Found Inadequate.Caused by Procedure Possibly Rendering Diesel Generators 1A & C Inoperable.Procedure Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000321/LER-1986-020, :on 860425,RWCU Sys Inboard & Outboard Primary Containment Isolation Valves 2G31-F001 & 2G31-F004 Isolated on High Leakage Flow Signal.Caused by Disconnected Jumper During Functional Test.Isolation Reset |
- on 860425,RWCU Sys Inboard & Outboard Primary Containment Isolation Valves 2G31-F001 & 2G31-F004 Isolated on High Leakage Flow Signal.Caused by Disconnected Jumper During Functional Test.Isolation Reset
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-020-01, :on 860924,primary Containment Penetrations Failed Local Leak Rate Tests.Full Description of Causes & Corrective Actions Will Be Provided |
- on 860924,primary Containment Penetrations Failed Local Leak Rate Tests.Full Description of Causes & Corrective Actions Will Be Provided
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000366/LER-1986-020, :on 860924,primary Containment Penetrations Failed Local Leak Tests.Caused by Normal Equipment Wear. Affected Valves of 34 Failed Penetration Tests Cycled, Repaired,Rebuilt or Replaced |
- on 860924,primary Containment Penetrations Failed Local Leak Tests.Caused by Normal Equipment Wear. Affected Valves of 34 Failed Penetration Tests Cycled, Repaired,Rebuilt or Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000321/LER-1986-021, :on 860501,full Reactor Protection Sys Logic Actuation Occurred,Causing Scram Discharge Vol Header to Fill.Caused by Broken Molded Bakelite Actuating Lever of Channel Scram Relay.Relay Replaced |
- on 860501,full Reactor Protection Sys Logic Actuation Occurred,Causing Scram Discharge Vol Header to Fill.Caused by Broken Molded Bakelite Actuating Lever of Channel Scram Relay.Relay Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-021-01, :on 860828,reactor Protection Sys Motor Generator Set C Cabinet Output Breaker Tripped,Causing Loss of Power to Bus A.Caused by Failed Limit Switch Assembly. Limit Switch Assembly & Torque Switch Replaced |
- on 860828,reactor Protection Sys Motor Generator Set C Cabinet Output Breaker Tripped,Causing Loss of Power to Bus A.Caused by Failed Limit Switch Assembly. Limit Switch Assembly & Torque Switch Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-022, :on 860514,RWCU Sys Isolated Due to High Temp Conditions within RWCU HX Pump Room Area.Caused by Personnel Using Original Design Data Instead of Field Operating Conditions to Establish Tech Specs Setpoint |
- on 860514,RWCU Sys Isolated Due to High Temp Conditions within RWCU HX Pump Room Area.Caused by Personnel Using Original Design Data Instead of Field Operating Conditions to Establish Tech Specs Setpoint
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-022-01, :on 860829,reactor Protection Sys Scram Occurred When Technician Performing Surveillance Testing Attempted to Open Stuck Valve on Yarway Instruments.Caused by Personnel Error.Procedure Revised |
- on 860829,reactor Protection Sys Scram Occurred When Technician Performing Surveillance Testing Attempted to Open Stuck Valve on Yarway Instruments.Caused by Personnel Error.Procedure Revised
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-023, :on 860515,reactor Scram Occurred While Personnel Returning Main Steam Line Transmitter to Svc. Caused by Procedural Inadequacy.Transmitter Properly Filled, Vented & Placed Into Svc |
- on 860515,reactor Scram Occurred While Personnel Returning Main Steam Line Transmitter to Svc. Caused by Procedural Inadequacy.Transmitter Properly Filled, Vented & Placed Into Svc
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-023-01, :on 860903,reactor Protection Sys Scram Occurred.Caused by Leaking Oil Filter Gasket Initiating Main Turbine trip.Electro-hydraulic Control Leak Repaired, Procedures Revised & Personnel Counseled |
- on 860903,reactor Protection Sys Scram Occurred.Caused by Leaking Oil Filter Gasket Initiating Main Turbine trip.Electro-hydraulic Control Leak Repaired, Procedures Revised & Personnel Counseled
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000366/LER-1986-024-01, :on 860904,reactor Scrammed.Caused by Dirty Relay Contacts,Preventing Offgas Condenser Drain Valve from Opening & Creating Vacuum Loss.Contacts Cleaned.Valve Function Verified |
- on 860904,reactor Scrammed.Caused by Dirty Relay Contacts,Preventing Offgas Condenser Drain Valve from Opening & Creating Vacuum Loss.Contacts Cleaned.Valve Function Verified
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-024, :on 860512,4 H Sample of Reactor Water Coolant for Conductivity Measurement Not Obtained Due to Presence of Steam Instead of Water in Sample Line.Caused by Failure of Liquid Sample Panel cooler.W/860611 1tr |
- on 860512,4 H Sample of Reactor Water Coolant for Conductivity Measurement Not Obtained Due to Presence of Steam Instead of Water in Sample Line.Caused by Failure of Liquid Sample Panel cooler.W/860611 1tr
| 10 CFR 50.73(a)(2)(1) |
| 05000366/LER-1986-025-01, :on 861023,personnel Determined That Certain Instruments Listed in Tech Specs Not Tested Periodically to Assure Appropriate Sys Actuation.Caused by Personnel Error. Personnel Counseled |
- on 861023,personnel Determined That Certain Instruments Listed in Tech Specs Not Tested Periodically to Assure Appropriate Sys Actuation.Caused by Personnel Error. Personnel Counseled
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(1) |
| 05000321/LER-1986-025, :on 860522,trip & Isolation of Reactor Bldg & Refueling Floor Ventilation & Closure of Inboard Isolation Valves on Hydrogen/Oxygen Analyzer Occurred.Caused by Blown Fuse Due to Personnel Error.Fuse Replaced |
- on 860522,trip & Isolation of Reactor Bldg & Refueling Floor Ventilation & Closure of Inboard Isolation Valves on Hydrogen/Oxygen Analyzer Occurred.Caused by Blown Fuse Due to Personnel Error.Fuse Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000321/LER-1986-026, :on 860605,during Performance of Special Functional Test on Reactor Protection Instruments,Determined That Procedures Did Not Include Step to Perturb Water Level. Caused by Personnel Error.Procedures Under Rev |
- on 860605,during Performance of Special Functional Test on Reactor Protection Instruments,Determined That Procedures Did Not Include Step to Perturb Water Level. Caused by Personnel Error.Procedures Under Rev
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(1) |