LER-81-022-01T, LER-81-22-1T, NUDOCS 8106090731
Download: ML20004D755 (3)


LER-1981-022, /01T-0:on 810520,secondary Containment Integrity Not Maintained Due to Personnel Access Airlock Doors Ajar. Caused by Personnel Error & Loosened Striker Plate on Inside Door.Outside Door Closed & Striker Plate Repaired
Event date:
Report date:
2191981022R01 - NRC Website

text

r

~

~

~'

U. S. NUCLE A"3 f.ET.ULATORY COMMIS$3ON Nec sonM 3s4

,wrn LICENSEE EVENT REPORT CcNTRot sLOCx: l l

l l

l l

iPLEAst PmNT OR TYPE ALL REQUIRED INFORMATIONI i

i

' lo Iil lN } J lO lC lP l1 g 0l 0l -l 0 [ 0 l 0.l 0 l0 l-l0 l0 g 4l 1l lj lj 1lgl l

[g i

8 9 UCEreSEE C00g 1.

18 WCEN34NLMeEA 25 26 UCENSE TV,4 40 93 sai la CON'T IoIiI "S"Ce l L l@l0 l 5 l0 l0 l0 l2 l1 p @l 0 l 512 l0 l811 l@lo 16 lo la ls 11 l@

s 7

8 80 St COCKET NUMSgm G5 09 EVENT GAfg F.

73 PEPSMT;4TE 83 EVEN r CESCRIPTICN AND PRCSABLE CCNSECUENCES

..___ i o 1 : L[ At approxinately 2300 hours0.0266 days <br />0.639 hours <br />0.0038 weeks <br />8.7515e-4 months <br />, the off Drywell Security Guard found l

l both doors o'f the NW corner 23' elev. personnel airlock ajar. Apparent-t

_ i o ; 3,

,io;4; lly the inside door failed to close due to a loosened striker plate, and l

i o e s ; ; the second door was deliberately cpened. All of the functional require-l lC ee i i ments were met for conditions not requiring secondary contain: Tent intoc-l l c { : ; i rity, except for the reactor node switch, which was in " REFUEL" instead

[

i o 6 a i I of " SHUTDOWN".

l j

30 T

g 4 systtV

CAuSE

CAvst CCMP VA Lv t 00*3

.0004 1U50001 00?.t,0 N E *:T0008

$Ut:005

$US 001 toisi i s iD (@ IA l@ l x l@ l Pl El Nl El Tl Rl@ l A l@ l Zl@

l 7

4 3

to 1

12 12 18

'9 23 SEQUENTIAL CCCURRENCE mt#0RT R EV'S'ON EVENTYE44 m Eacm T NO.

CODE Tv75 N O.

O.;ggs ao i 81 11 1-1 1012l2l l-l 10l1l lT I L--J 10 l.

5l,g

_:i u

u 2

u 27 a

s a

si u

7 N A.' C N O P T

t T pe0U83 58 4

,08 a 5.

SU,*L E MANU8A sta I a l@LM@

l zi@

MJ@

l 01010 Io I I Yl@

l.y_.J@

lAl@

l a i s 1710 i@

u 2A u

u a

.a 2

CAUSE CESCRIPTiCN AND CORRECDVE ACTIONS i,,oi;The cause was attributed to personnel error. Once the inside door did i,,,,;not close, the second door was deliberately opened. The Group Shift l

, Supervisor closed the outside door and Mechanical Maintenance personnel

repaired the striker plate on the inside door.

li i. i 1 I

a 9 so QiSCOVERY 0gscniptics h STAT

% POWER QTHERSTATUS 085 RY is is i i cl@ 101010 l@l NA I

l A l@l Security Guard Cbservation l

a

' A!nvin est ~T AucusTo, ACmiTv @ I toCATie~e..Eusi@

l i I s l LaJ @o e, meas.Iz l@l suAss NA I

NA I

... senna nx, esses Oiscai, Tie ~ @

~uM..

Tv,e l i l 71 1 01 01 Ol@lzl@l NA l

[

0

,,,,Cs

.t'a E, Oiscai,Tio~@

t NuMEi.

li ta l I 010101@l NA l

7 8 9 11 12 go LOSS 08 04 OAM AGE TO FACILITY p

Tv't OE5Cassitoq IIIII [,Zj@l NA l

)

. 9 10 30

,ssu,7' 0.10609073 10 I o i I Y l@it7Ca*Tio~@ weeklyNewsRelease/

NRc Usz cNtv lf j l

l [lll lll ll l l l i

8 9 to 68 66 go.; i Michael J. Fitzgerald (609) 693-6038 o-NAME OF PRE 8ARER PHCNE:

g.i 5

OYSTER CREEK NIX 1 EAR GENERATING STATICN Forked River, New Jersey 08731 Licensee Event Report Reportable Occurrence No. 50-219/81-22/01T Report Date June 3, 1981 Occurrence Date i

May 20, 1981 l

Identification of Occurrence A violation of Technical Specifications, paragraph 3.5.B.1 occurral when secondary contaht integrity was not maintainal at all times. Both personnel access airlock doors en the Northwest side of the Peactor 9141 ding were found ajar.

'Ihis event is considered to be a reportable occurrence as defined in the Technical Specifications, paragraph 6.9.2.a.6.

conditions Prior to Occurrence The plant was shutdown in the REEUEL Itode with reactor tatperature less than 2120F.

~

yescription of Occurrence At approximately 2300 hours0.0266 days <br />0.639 hours <br />0.0038 weeks <br />8.7515e-4 months <br /> on May 20, the offgoing drywell Security Guard discovered both the inside and outside (NW corner, 23' elevation) Reactor Building personnel access airlock doors ajar. In this configuration the door interlock systen prevents either door frcm closing. The Group Shift Supervisor was imadintely notified and the problem was corrected by bypassing the inter-lock systen and closing the doors. The doors had been checked earlier on the 4-12 shift and were found closed. It is postulated that when the inside door failed to close due to a loosened striker plate, the outside door was opened using the installed interlock bypass systen by persons unknown. Once both doors were open the interlock prevented them frcxn closing.

Apparent cause of Occurrence The cause of the occurrence was attributed to personnel error. Although the 3

inside door failed to close due to a' loosened striker plate, the interlock protecting the 'seccnd door frcm opening had to be deliberately bypassed.

Analysis of Occurrence Secondary containment is designed to minurize any ground release of radioactive materials which might result frcxn a serious accident. 'Ihe Beactor Building provides secondary containment during reactor operation when the drywell is sealed and in service and provides prirrary containment when the reactor is shutdown and the drywell is open.

I i

P e

t y-

Reportable Occurrence Page 2 Report No. 50-219/81-22/0lT Mien this event occurred, all of the requiremnts of the Technical Specifications

. paragrapt 3.5.B.1, except for the reactor mode switch position, were met for conditions which do not require secondary containment integrity. 'Ihe reactor mode switch was in "REEUEL", whereas the Technical Specifications required "SifrIDCm" if secondary containment integrity is not maintained. In strmary, the major functional requirenents were met for conditions not requiring secondary containment integrity.

Corrective Action

The offgoing Security Guard inmiiately notified the Group Shift Supervisor, who closed the outside door by manually overriding the interlock mechanism. Within several minutes Mechanical Maintenance personnel repaired the loosened striker plate on tra inner door and the doors were returned to service. Currently, as

~ part of the General Enployee Training, the proper operation of personnel airlock doors is addressed. The secondary containment airlock doors and interlock mechanism will be added to the P.M. schedule to reduce the possibility of door malfunctions which may result in individuals bypassing the interlock.

Failure Data Not Applicable.

t 90 t