ML19345F464

From kanterella
Jump to navigation Jump to search
LER 80-052/03L-0:on 801230,RHR Svc Water Sys Throttle Valve SW-MO-89A Failed to Respond to Remote Controller After Opening to Min Flow Position.Cause Unknown.Investigation Underway
ML19345F464
Person / Time
Site: Cooper Entergy icon.png
Issue date: 01/29/1981
From: Doan P
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19345F459 List:
References
LER-80-052-03L, LER-80-52-3L, NUDOCS 8102170523
Download: ML19345F464 (1)


Text

-- . . _ _ . _ - . ---

PIRC PoSM 366 U. S. NUCLE AR REGULAroRY CoMMISSloN wi -

LICENSEE EVENT REPORT CONractStoCoI, I l I 1 1 l@ iPtEASE PRiNr oR rvPE 4tt REcuiREo iNPoRuarioNi l 0 l 413 l l NLacENSEE 7

l E l Cl CODE Pl Rl 1l@l 0l 0l - l 0LICENSE 14 1S l 0 lN-0aV6ER l 0l -l 0l 0l 0l@l 25 215

/. l 1LICENSE l 1 l TvPE1l 1[@l JO l

$7sATSd l@

CON'r 10l1I ."$"CE I Lhl0 l 510 l 0 l 0 l 2 l 96dI 869l@lEVENT 11 DATg 21 31 01 dl 01PsPO*T 14 75 il ?!OATE 9l 81 80il@

/ 8 60 el OOCK ET NuveER EVENT oESCRiPrlON ANo PROB ABLE CONSEQUENCES h I o I 2 I During normal surveillance testing of the RHR Service Water Systegi SE-Mo-89A. the 1 1

loI31l Loop "A" system throttle valve on the discharge of the "A" RHR heat exchanger, afteri 19141 ppening to the minimum flow position would not respond to the remote controller. Thel j.

Io !s] l redundant loop was operable as well as both diesel generators. There were no adversel l f a ls t laf fects to the public health and safety. (RTS 3.5.B) 1 10171 l i l

I 0181 I 83 r es

' C$NE [O$E susci$E CovPONENT CODE S SC OE SU OE 3 L,o L2J,,

l c I r l@ L,,x_J@ L,,3_J @ l v I A l t I vio le l@ L,2A_j@ [Z_j

,o ,2 ,. m @

,,,, SEQUE NTI AL OCCURRENCE REPORT REVISION LER RO EVENTYEAR REPORT No. CODE TYPE NO

@ agg u I81 01 l-l 10Isl21 1/l I ol 31 LJJ I-1 LJ 9

_ 21 22 23 24 .6 27 28 M 30 31 32 TA N AC O ON PL NT VET HOURS SS IT FOR 9. S PP MANUFACTURER LzJ@LxJ@ 1.z.J@ LI_J@ l01010101 lsJ@

41 l

l@ LLJ@ lt 12101047l@

l 3J J4 Jb 36 3 40 42 4J 44 CAUSE oESCRIPrioN ANo CORRECTIVE ACTIONS l > t o l lSW-M0-89A is a 18", 300# Globe valve with a timitorque SMB-3 motor operator. The l

}

I i I i i leauee of the problem is unknown. The failure could not be repeated. Recorders are I 4

m l monitoring output of the controller, feedback from the valve positioner, and the I i ' I 3 I lopen and close contacts on the operator motor for 5 subsecuent valve oeerations to l i

LL,14 ] Ivori #v nnornhiliev 80

? 8 9 STA . POWER OTHER STATUS ISCO RY OiSCOVERY DESCRIPTION 1 i i o 1 [E_j@ l Ol 91 9l@l Operator Observation l NA l l" Bl@l** 8

'JT,v,Tv CDATENT REM ASEO N REM ASE LOCATION OF REMASE @

IT (z_j @ lz.j@l AMOUNT NA OF ACTIVITY l 45

@l NA 80 l

7 a 7 to tt 44 PE RSONNE L (EPOSURES l NUMBER TYPE DESCRIPTION 39 l

li' l il*l010 l o l@[ '

zJ@l

NA

'o PERsONNE'L,mu'!,ES Nue ER DESCR,PT,0N@

I LLL ] I 01010 l@l

/ M 1 11 12 NA 80 t h of OH O TAG TO F ACittTV NA l Lua.J r 4 9 l z l@lto 80 Putu H.fv NRC USE ONL Y l 45 c.e t i l I n l l N l'@ancniptioy l NA  ; g,,;;y,,,,,9lj

' a 9 'o e. ., .0. ;

NAVE OF PREPARER PHONE:

6102 7 05c .-

--_1 -- - _ _ - - - - _ - - - _ __ _ _ _ _ _ _