w

(

,- s),

UNITED STATES

,g y 'g s.

'i NUCLEAR REGULATORY COMMISSION

.g h{.,. y WASHINGTON, D. C,20555

%, -Q, f

August 18, 1980 Docket No. 50-346 Mr. Richard P. Crouse Vice President, Nuclear Toledo Edison Company Edison Plaza 300 Madison Avenue Toledo, Oh,io 43652

Dear Mr. Crouse:

We have reviewed the information you provided us in your letter dated August 4,1980, which was in response to our request for additional information on reactor coolant system flow sensing lines at Davis-Besse.

As a result of this review, we are concerned about the close I.7ximity With of the redundant flow sensing lines and the flow transmitters.

respect to meeting the single failure criterion, you are requested to provide a discussion of the high energy line break effects on: a) the flow sensing lines inside the secondary shielding, and b) the flow transmitters.

It is requested that this information be provided by August 25, 1980.

Sincerely, 0

k k k'l, 'hsv Robert W. Reid, Chief Operating Reactors Branch #4 Division of Licensing cc:

See next page 800gggo 3qg

~

L 0

  • e.

,t Toledo Edison Company ec w/ enclosure (s):

Mr. Donald H. Hauser. Esq.

U.S. Nuclear Regulatory Comission The Cleveland Electric Resident Inspector's Office Illuminating Company 5503 N. State Route 2 P. O. Box 5000 Oak Harbor, Ohio 43449 Cleveland, Ohio 44101 Director, Technical Assessment 4

Gerald Charnoff, Esq.

Division Shaw, Pittman, Potts Office of Radiation Programs and Trowbridge (AW-459) 1800 M Street, N.W.

U. S. Environmental Protection Agency Washington, D. C.

20036 Crystal Mall #2 Arlington, Virgi.11a 20460 Leslie Henery, Esq.

Fuller, Seney, Henry and Hodge U. S. Environmental Protection Agency 300 Madison Avenue Federal Activities Branch Toledo, Ohio 43604 Region V Office ATTN: EIS COORDINATOR Mr. Robert B. Borsum 230 South Dearborn Street Babcock & Wilcox Chicago. Illinois 60604 Nuclear Power Generation Division Suite 420, 7735 Old Georgetown Road Bethesda, Maryland 20014 Ida Rupp Public Library Ohio Department of Health 310 Madison Street ATTN: Director of Health Port Clinton, Ohio 43452 450 East Town Street Columbus, Ohio 43216 President, Board of County Commissioners of Ottawa County Port Clinton, Ohio 43452 Attorney General Department of Attorney General 30 East Broad Street Colunbus, Ohio 43215 Harold Kahn, Staff Scientist Power Siting Comission 361 East Broad Street Columbus, Ohio 43216 i

Mr. Rick Jagger Industrial Commission State of Ohio 2323 West 5th Avenue Columbus, Ohio 43216 Mr. Ted Myers Licensing Engineer Toledo Edison Company Edison Plaza 300 Madison Avenue Toledo, Ohio 43652 m

-