MONTHYEARML23165A2492023-06-14014 June 2023 4Q 2022 Performance Summary U4 ML22334A0832022-12-0101 December 2022 Attachment 1 - Targeted ITAAC Listing VEGP Unit 4 ML22334A0842022-12-0101 December 2022 Attachment 2 - ITAAC Family Listing VEGP Unit 4 ML21278A3552021-10-0505 October 2021 Enclosure 2: Safety Determination Input for IEEE 384 Separation Issues and Safety Determination Input for IEEE 384 Separation Issues within IDS Enclosures ML21278A3562021-10-0505 October 2021 Enclosure 3: AP1000 Plant At-Power Internal Events PRA Risk Assessment for Spatial Separation Criteria Nonconformances ML21277A0212021-10-0404 October 2021 2021 Q2 Cross Cutting Page ML20358A1802020-12-23023 December 2020 (VEGP) Units 3 and 4 - Proposed Alternative in Accordance with 10 CFR 50.55a(z)(2) - Alternative Requirements for A8ME Section XI Examination Coverage of Weldolet Branch Connection Welds (VEGP 3&4-PSI/ISI-ALT-15) ML20343A0432020-12-0808 December 2020 Construction Reactor Oversight Process Resources December 2020 ML20022A0602020-01-20020 January 2020 Assessment of Communications in Response Request for Information for Vogtle Electric Generating Plant Units 3 and 4 ML19325C6722019-11-21021 November 2019 Staff Bullets for October 21, 2019 Public Meeting, Vogtle Electric Generating Plant Units 3 and 4, LAR-19-017, Request for License Amendment: Removal of the PRHR-HX Natural Circulation Test ML19233A0072019-08-22022 August 2019 NRC Contacts for New Power Reactors ML19113A0922019-04-23023 April 2019 Functional Arrangement ITAAC Acceptance Criteria R1 ML17235B1482017-08-23023 August 2017 U.S. Nuclear Regulatory Commission - Tornado Missile Risk Evaluator (TMRE) Methodology Topics and Methodology Feedback ML14141A6272014-05-20020 May 2014 LTR-14-0288-Ticket - Senator Edward J. Markey Ltr. Information About NRC-Sanctioned Job Shadow Program with China ML14094A3582014-04-0808 April 2014 Enclosure - PWROG Peer Review Form 4-03-14, Table 1 ML14078A6212014-04-0101 April 2014 Enclosure 3 - RASCAL 4.3 Inputs for Site Boundary Dose Projections ML14072A4542014-03-0606 March 2014 Response to NRC Request for Additional Information Site Plan, 2-1, Sheet 1 of 1 ML14072A4632014-03-0606 March 2014 Response to NRC Request for Additional Information 2-1, Sheet 3 of 10 ML12056A0522012-03-12012 March 2012 Enclosure 6 - List of Power Reactor Licensees and Holders of Construction Permits in Active or Deferred Status ML1135406252012-02-10010 February 2012 Amendment to Indemnity Agreement No. B-107 - Amendment No. 6 ML12010A0342011-12-28028 December 2011 Onsite Ground/Surface Water Questionnaire, Onsite Radiological Effluent/Remp Monitoring Program ML1122005052011-08-0404 August 2011 Crop Tabletop Example Findings ML1132604282011-01-0303 January 2011 NRC 2011 Vogtle ML1019301932010-06-0909 June 2010 Undated Onsite Ground/Surface Water Monitoring Questionnaire 4 for Vogtle ML1019304602010-03-25025 March 2010 List of Historical Leaks and Spills at Us Commercial Nuclear Power Plants NL-08-0869, Enclosure 11, List of Regulatory Commitments2008-06-27027 June 2008 Enclosure 11, List of Regulatory Commitments ML0811902022008-04-24024 April 2008 End of Cycle Public Meeting Attendee List ML0808000362008-03-13013 March 2008 List of Attendees, 03/13/2008 Summary of Meeting with Eight Operating Nuclear Power Plant Licensees to Discuss Emerging Metallurgical Issues Certain Welds in Reactor Coolant System for Pressurized-Water Reactors ML0806704192008-03-0707 March 2008 CDBI Findings ML0732407642007-11-0505 November 2007 Vogtle - FSAR-2, Calculation Package ML0732407472007-11-0505 November 2007 Electrical Design Parameters of Typical 230kv and 500kv Transmission Lines Terminating Into Plant Vogtle ML0732407112007-11-0505 November 2007 Project Wings (Wildlife Incentives for Nongame and Game Species) ML0732400242007-10-25025 October 2007 Examples of Max Thermal Power License Conditions ML0726301142007-09-14014 September 2007 / P. Paquin Ltr Amendment to Certificate of Compliance No. 9208 for the Model No. 10-142B Package (TAC L24117)/S121170 ML0732407042007-06-27027 June 2007 Cooperative Safe Harbor Management Agreement (2005 Updated Version) No. 28 for Red-Cockaded Woodpeckers (Picoides Borealis) and Their Habitat on Private Land in Georgia ML0714103852007-05-17017 May 2007 Enclosure 1 - Attendee List for 05/17/2007 Vogtle Public Meeting ML0713402122007-05-10010 May 2007 Log of Congressional Correspondence for January 16, 2007 - February 28, 2007 ML0634705992006-12-14014 December 2006 Plant Service List ML0619203352006-04-14014 April 2006 Attachment 3 - List of Attendees for April 14, 2006 Public Meeting to Discuss Vogtle Early Site Permit Seismic Activities ML0609006412005-10-11011 October 2005 Spent Fuel Pool Action Plan, from Entergy ML0732407432005-08-22022 August 2005 Submittal of Photocopies of the Highway Capacity Manual 2000 ML0732407362005-02-21021 February 2005 Safe Drinking Water Information System ML0404104922004-02-20020 February 2004 Order EA-03-009 Service List ML0732407172003-07-24024 July 2003 Movement and Population Size of American Shad Near a Low-Head Lock and Dam ML0732407292000-01-31031 January 2000 Habitat Utilization and Biological Characteristics of Adult Atlantic Sturgeon in Two South Carolina Rivers ML0732407661999-07-31031 July 1999 Savannah River Basin Comprehensive Reconnaissance Study ML0732407411999-06-0606 June 1999 State of Georgia, Permit No. GA0026786, Authorization to Discharge Under the National Pollutant Discharge Elimination System ML0732406901998-04-0101 April 1998 State of Georgia, Permit to Operate a Public Water System Issued on 04/01/1998 to Vogtle Plant ML0732407461997-05-0808 May 1997 Georgia Power Transmission Bulletin, Maintenance of Plant Vogtle Transmission Line Corridors ML0630002251997-05-0808 May 1997 Georgia Power Transmission Bulletin No. 6-10: Maintenance of Plant Vogtle Transmission Line Corridors. Revised 2023-06-14
[Table view] |
Text
11/21/2019 Technical Discussion of LAR 19-017, Removal of the Preoperational Passive Residual Heat Removal Heat Exchanger Natural Circulation Test.
Below lists supplemental information needed to support the staffs review.
- 1. Additional information to be included in the LAR submittal:
- Integrated system frictional and minor head loss acceptance criteria.
- Discussion regarding how the forced flow test can demonstrate the as-built friction loses with margin to design values and is appropriate given flow regime differences between prior to establishment of natural circulation and fully developed flow.
- Information related to any analytical reconciliation that will be performed of the as-built forced flow test data of parameters related to initiation of natural circulation against the validated LOFTRAN model.
- 2. Available for Audit:
- China test information for parameters related to the initiation of natural circulation.
- Validation or confirmation of LOFTRAN performance and capability to predict the initiation of natural circulation based on the as-built tests performed at China plants including a comparison of as-built frictional losses to the design values.
- Sensitivity studies relative to frictional margin.