ML073240717

From kanterella
Jump to navigation Jump to search
Movement and Population Size of American Shad Near a Low-Head Lock and Dam
ML073240717
Person / Time
Site: Vogtle  
Issue date: 07/24/2003
From: Marissa Bailey, Bridges W, Isely J
Clemson Univ
To:
Office of Nuclear Reactor Regulation
References
NL-07-2097
Download: ML073240717 (9)


Text

Transactions qf the American Fisheries Society 133:300-308, 2004

© Copyright by the American FisheJies Society 2004 Movement and Population Size of American Shad near a Low-Head Lock and Dam MICHAEL M. BAILEY Department of Aquaculture, Fisheries, and Wildlife, Clemson University, Clemson, South Carolina 29634-0362, USA J. JEFFERY ISELY*

U.S. Geological Survey, South Carolina Cooperative Fish and Wildlife Research Unit, Clemson University, Clemson, South Carolina 29634-0372, USA WILLIAM C. BRIDGES, JR.

Department of Experimental Statistics, Clemson University, Clemson, South Carolina 29634, USA Abstract.-We investigated the population size and the proportion of the population of American shad Alosa sapidissima that passed through the New Savannah Bluff Lock and Dam, a low-head lock and dam on the Savannah River in South Carolina and Georgia. We fitted 110 American shad with radio transmitters in 2001 and 2002. All but two fish moved downstream after transmitter implantation. In 2001, a smaller proportion of American shad implanted with radio transmitters earlier in the season returned to the dam than fish released later. Of the fish that returned to the dam, over 50% in 2001 and 9% in 2002 passed through the lock and continued migrating upstream.

In both years, the modal daily movement distance was less than 1 km. Movements greater than 5 km/d were generally associated with fish rapidly returning upstream after their initial downstream movement. Continuous diel monitoring indicated that movements greater than 0.1 krnlh were more frequent at night than during the day. In both years, American shad were not uniformly distributed over the study area but were predominantly grouped just below the dam and in a relatively large pool approximately 6 km below the dam. We estimated the population size of American shad that reached the New Savannah Bluff Lock and Dam at 157,685 in 2001 and 217,077 in 2002.

The American shad Alosa sapidissima is an anadromous clupeid native to the East Coast of North America from the St. Johns River, Florida, to the St. Lawrence River, Canada (Liem 1924; Bigelow and Schroeder 1953). The timing of the spring spawning migration varies with latitude (Leggett and Whitney 1972) and is closely linked to temperature. American shad may enter their na-tal streams once the water temperature rises above 4°C; however, spawning activity is greatest be-tween 14°C and 21°C (Walburg and Nichols 1967; Leggett and Whitney 1972).

Since the late 1800s, a suite of factors has caused a decline in anadromous stocks in the genus Alosa along the East Coast. Most markedly, the construction of dams has greatly reduced the num-ber of spawning and nursery grounds (Rulifson 1994). Although some fishways were constructed when dams were built, most were not effective (Stevenson 1899). Navigation locks have been

  • Corresponding author: jisely@clemson.edu Received February 6, 2003; accepted July 24, 2003 considered alternatives to fishways, although their effectiveness has generally not been assessed (Nichols and Louder 1970). Passage efficiency for American shad through a low-head lock varied from 15% to 50% over a 3-year period (Moser et al. 2000). Other migratory species show similar low and variable passage rates through lock sys-tems (Chappelear and Cooke 1994; Pegg et al.

1997).

Passage may be related to retention time in the vicinity of the passage facility (Barry and Kynard 1986). Retention time of American shad has not been closely studied, but other migrating fish spe-cies have exhibited large variation in the time spent in a tailrace prior to passage or out-migration (Chappelear and Cooke 1994; Pegg et al. 1997).

Nocturnal fallback-the temporary out-migration of fish encountering a barrier after sunset-has been documented (Barry and Kynard 1986). High diel variation in movement, passage, and velocity preference has also been observed (Theiss 1997; Moser et al. 2000).

The objective of this study was to examine the 300

POPULATION SIZE AND MOVEMENT OF AMERICAN SHAD 301 Augusta City Lock and Dam (River km 333)

New Savannah Bluff Lock and Dam (River km 301 )

Limit of routine monitoring (River km 275)

FIGURE I.-Location of primary area of monitoring centered by the New Savannah Bluff Lock and Dam.

diel and seasonal behavior of migrating American shad when encountering the New Savannah BluffLock and Darn (NSBLD). Specifically, we investigated the proportion of the population that passed through the lock, retention time in the tail-race, and the diel and within-season movement patterns of American shad during their spring spawning run. In addition, we estimated the pop-ulation size of American shad that reached NSBLD.

Study Area The study area consisted of the Savannah River, South Carolina and Georgia, from the Augusta City Lock and Darn, located at river kilometer (RKM, measuring from the river's mouth) 333.5 to the influence of brackish water at about RKM 35, with emphasis on the river reach from RKM 275 to RKM 333.5 centered on NSBLD (Figure 1). NSBLD, located at RKM 301 just south of the city of Augusta, Georgia, is the most downstream obstruction to migration on the Savannah River.

Completed in 1937 to enhance water control and navigation, the darn spans a 130-m section of the river. The low-head darn consists of five indepen-dent, 18-m-wide gates with a connected navigation lock on the Georgia abutment. The lock measures 17.1 m wide X 109 m long and has a lift capacity of 4.6 m.

The lock is operated in the spring of each year specifically to pass a variety of migrating fish, in-cluding striped bass Marone saxatilis, blueback herring A. aestivalis, and American shad. During this study, an average of five locking events for the purpose of fish passage were conducted each Monday from March through May between 0730 and 1600 hours0.0185 days <br />0.444 hours <br />0.00265 weeks <br />6.088e-4 months <br />. Each locking event consisted of the following sequence: (1) one lower door was fixed in the open position; (2) a fill valve was partially opened for at least 20 min to create a current in the lock thought to attract fish; (3) the lower door was closed; (4) the lock was filled; and finally (5) the upper doors were opened for at least 15 min. In order to operate the lock safely, a max-imum head differential of 4 m was permitted. Con-sequently, on days prior to and during locking, discharge at NSBLD was increased to lower the water level above the darn and raise the water level in the tailrace.

Methods Fifty-one fish in 2001 and 59 fish in 2002 were fitted with radio transmitters (Lotek Wireless, Newmarket, Ontario, Canada). To facilitate gastric implantation, transmitters were affixed to a flexible tube and inserted into the stomach though the mouth. The tube was then removed, leaving the antenna trailing from the mouth. Transmitters were coated in a water-soluble, nontoxic lubricant to reduce trauma during insertion. The sex of the fish was determined by applying gentle pressure to the abdomen to express eggs or milt. Transmitters were only inserted into robust, healthy fish. This process required less than 2 min per fish.

Three different radio transmitters were used in this study. In 2001, the transmitters were bottle shaped, measuring 9.2 mm in diameter and 20 mm in length and weighing 1.5 g in water, or measuring 10 rnm in diameter and 32 mm in length, and weighing 2.1 g in water. The transmitters pos-sessed a minimum battery life of 39 or 61 d, re-spectively. In 2002, the radio transmitters were cylindrical, measuring 11 mm in diameter and 36 mm in length, weighing 3.4 g in water, and pos-sessing a minimum battery life of 110 d. All trans-mitters weighed less than I % of the body weight of the smallest study fish.

American shad were located with a portable ra-dio receiver and a directional Yagi antenna. Po-sitions were determined at least four times per week from the release date until the last week of May between NSBLD (RKM 30 I) downstream to at least RKM 275, and were recorded to the nearest 0.1 km. Fish that passed above NSBLD were 10-

302 BAILEY ET AL.

cated at least once per month up to the next barrier to migration at RKM 333.5. The passage efficiency of migrating American shad at NSBLD was based only on fish returning to the tailrace. A subsample of instrumented fish was located every 2 h from NSBLD to RKM 275 over continuous 48-h (2001) and 60-h (2002) periods beginning on May 7, 2001, and May 13,2002. The hours between 0600 and 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> were considered day, and those between 1800 and 0600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> were considered night.

In addition to roving telemetry, fixed-station continuous monitoring of fish near the dam was conducted. In 2001, five antennas were mounted on the face of the dam and one was mounted on the wing wall of the upstream end of the navigation lock. In 2002, four antennas were mounted on the face of the dam, and three were mounted in the lock to monitor the entrance, middle, and exit.

When an implanted fish was detected, a data log-ging receiver recorded the identification number, date, time, signal strength, and the receiving an-tenna number. In addition, average daily and hour-ly discharge and river stage information was ob-tained from the U.S. Geological Survey gauging station (02197000; provisional data) at NSBLD for 2001 and 2002.

Change in American shad location in relation to time after transmitter implantation and flow was analyzed by analysis of variance (ANOVA). Fish-er's least-significant-difference test was used for comparison of least-squares means. Proportion data were analyzed using a chi-square test. Be-cause multiple seasonal and hourly measurements were taken from individual American shad, a mixed model of repeated measures was used in seasonal and diel movement analysis. Year, sex, and flow were fixed effects, and fish was a random effect in the mixed model. American shad passage related to the number of times a fish returned to the area below the dam was analyzed by logistic regression. When assumptions of normality were not met, data were appropriately transformed. In all cases, transformations failed to change statis-tical outcomes and are therefore not presented.

We estimated the population size of adult Amer-ican shad reaching NSBLD with the Peterson method for a randomly mixed population (Ricker 1975) using the equation N = MCIR, where N is the population size, M is the number of fish marked and released (adjusted for tag re-tention, differential migration, and survival), Cis the number of fish in the recapture sample, and R is the number of fish recaptured (adjusted for re-porting rate). We chose not to correct the equation using the Chapman modification, as the number marked and examined for marks was large. During the peak in American shad spawning migration in 2001 (between March 13 and April 9) and in 2002 (between March 11 and April 3), 739 and 812 adult migrating American

shad, respectively, were marked (M) with either one or two internal anchor tags and released in the tailrace below NSBLD.

All tagging was conducted between 0900 and 1500 hours0.0174 days <br />0.417 hours <br />0.00248 weeks <br />5.7075e-4 months <br />. Fish were collected by boat electrofishing techniques. After capture, healthy fish were im-mediately tagged without anesthesia and released within 2 min of capture. Internal anchor tags im-printed with a unique identification number and a phone number to facilitate return were insertedjust below the dorsal fin perpendicular to the ptery-giophores.

A recreational fishery targeting American shad was used to collect fish for the recapture sample (R) during a 6-week period following marking.

Recreational harvest (C) was estimated in 2001 and 2002 using standard creel survey techniques (Malvestuto 1983) in which over 23% and 38% of angling time, respectively, was sampled. Posters displayed at fishing access points instructed an-glers to return tags to a local cooperating bait shop, or to call the phone number appearing on the tag and poster. The reward for a returned tag was an embroidered hat, coveted by the local anglers. In order to estimate reporting rate, tags were distrib-uted to 25 anglers without added instructions as they exited the fishing area. We assumed anglers would treat these tags as they would tags recovered from captured fish. Twenty-two tags were returned, resulting in an estimated return rate of 88%. The number of recaptures was adjusted using this re-porting rate.

The number of marked fish was adjusted for tag retention, differential migration, and mortality.

Tag retention was based on returns of double-tagged fish (n 16), and was estimated at 94%.

Differential migration and mortality was estimated from the proportion of fish implanted with radio transmitters that died or migrated downstream and did not return to the dam, and was estimated to be 26% in 2001 and 47% in 2002, resulting in 74%

and 53% retention of tagged fish to the study area, respectively.

The combination of these adjustments for tag reporting, tag retention, and emigration resulted in

POPULATION SIZE AND MOVEMENT OF AMERICAN SHAD 303 TABLE I.-Study year, number of American shad im-planted with radio transmitters (N), number that expelled transmitters at point of tagging (Failure), number that died as a result of tagging or handling stress (Mortality), num-ber that did not make a downstream movement after radio implantation (Remained), number that returned to the tail-race after making initial downstream movement, and num-ber that did not return to the tailrace during the remainder of the season at the New Savannah Bluff Lock and Dam, Savannah River. Different letters indicate significant dif-ferences between years.

Moved downstream Did not Year N

Failure Mortality Remained Returned return 200t 51 3

7 29 z 10 2002 59 2

8 lly 37 bias adjustment coefficients of 61 % in 200 I and 44% in 2002. As the numbers of fish examined for tags was small with respect to population size, confidence intervals (95%) were estimated ac-cording to Ricker (1975) for large samples, based on a Poisson distribution of recaptures.

Results In 200 I, three study fish rejected the implanted radio transmitters immediately after tagging, and seven died within 5 d of implantation as a result of handling or tagging (Table 1). The remaining 40 fish were located an average of 20.2 (range =

5-51) times. One fish remained near the point of release, while 39 moved downstream from 1.3 km to greater than 30 km within 5 d of transmitter implantation. Although 29 fish returned to the tail-race during the study period, 10 did not. One fish continued moving downstream and moved below the area of daily tracking after 5 d. In 2002, two study fish rejected the implanted radio transmitters immediately after tagging, and eight died within 5 d of implantation as a result of handling or tag-ging. The remaining 49 fish were located an av-erage of 16.8 (range = 4-60) times. One fish re-mained near the point of release, while 48 moved downstream from 2.1 km to greater than 30 km within 7 d of transmitter implantation. Although 11 fish returned to the tailrace during the study period, 37 did not. Sixteen of those continued mov-ing downstream and moved below the area of daily tracking within 12 d. An angler in the tailrace cap-tured one fish that returned 31 d after release.

In 2001, fish moved downstream an average of from 7.4 to 26.0 km, depending on the implanta-tion date (Table 2). Fish tagged earlier in the sea-son moved downstream a greater distance and at TABLE 2.-Distance and rate of downstream movements associated with handling by tagging date in 200I and 2002 of American shad implanted with radio transmitters at the New Savannah Bluff Lock and Dam, Savannah River.

Similar letters indicate no significant differences within year and column. Ranges are given in parentheses.

Release date N

Distance (km)

Rate (km/d) 2001 Mar 22 14 19.3 (5.0-30) z 4.0 (0.4-7.5) z Mar 27 6

26.0 (6.1-30) z 6.8 (1.5-15.0) Y Apr 19 19 704 (1.2-24.9) y 1.8 (0.3-5.0) x 2002 Mar i8 10 24 (704-30) z 5 (1.6-7.5) z Apr 1 18 21.7 (2.1-30) z 5.5 (0.5-10.0) z Apr 15 20 19.0 (4.3-30) z 4.3 (0.8-10.0) z a greater rate than fish tagged late in the season (Table 2). In 2002, fish implanted on different dates moved an average of 19.0 to 24.0 km down-stream; however, we were unable to detect an ef-fect of release date on distance or rate of down-stream movement. We were unable to detect an effect of sex on the proportion of fish that made an initial downstream movement or that later re-turned to the dam in either year. More fish moved upstream to the area of the dam after transmitter implantation in 2001 than in 2002.

We were unable to detect a between-year dif-ference in the distance moved on a daily basis o

2 3

4 5

6 7

8 9

10 Distance (km/d)

FIGURE 2.-Frequency distribution of distance moved (interval midpoint) in 2001 (solid bars) and 2002 (open bars) of American shad implanted with radio transmitters near the New Savannah Bluff Lock and Dam, Savannah River.

304 BAILEY ET AL.

1111111111111111111111111111111111111111111111111111111111111111111111111111111 DAM 300 298 296 294 ~~~~==::J 292

E 290 s:::

0:::

288 286 284 282 280 278 276 -f==----.,..------,----,-----,

70 60 50

!e L

40

~c Q)

s

~ 30 lL.

20 10 a

0.1 0.2 0.3 0.4 0.5

>.5 FIGURE 3.-Frequency distribution of relocations over the interval from river kilometer (RKM) 275 to RKM 301 in 2001 (solid bars) and 2002 (open bars) by in-dividual American shad implanted with radio transmit-ters near the New Savannah Bluff Lock and Dam (hatched bar), Savannah River.

when the effect of individual variation was con-trolled. The distribution of daily movement was highly skewed (Figure 2). In both years, the modal daily movement distance was less than 1 km.

Movements greater than 5 km/d were generally associated with fish rapidly returning upstream af-ter their initial downstream movement. In 2001, the proportion of fish moving over 0.2 km/d in-creased with flow. In 2002, we were unable to detect an effect of flow on the proportion of fish that moved over 0.2 km/d. Males and females did not move different distances on a daily basis in either year when the effect of individual variation was controlled.

In 2001 and 2002, American shad were not uni-formly distributed over the study area but were predominantly grouped in two areas (Figure 3).

Approximately 25% of the locations were above RKM 300 and within 1.5 km of the dam. An ad-ditional 30% of the locations were between RKM 294 and RKM 295. This stretch consists of a series of tight bends with low-grade sand banks protected by two current-deflecting wing dikes. The section also contained two intermittent streams that were dry during most of the study period.

In 2001, 17 American shad were located an av-o 10 20 Frequency (%)

30 40 Distance (km/h)

FIGURE 4.-Frequency of hourly movement (interval midpoint) in 2001 (solid bars) and 2002 (open bars) during a 48-60-h period of intense study of American shad implanted with radio transmitters near the New Savannah Bluff Lock and Dam, Savannah River.

erage of 20.5 (range = 5-25) times during 25 con-secutive 2-h tracking periods. One fish was passed upstream by the navigation lock during this 2-d intensive study period. In 2002, seven American shad were located an average of 27.1 (range = 25-

30) times during 30 consecutive 2-h tracking pe-riods. Mean movement during the study period was greater in 2002 (0.19 +/- 0.018 km/h [mean +/- SED than in 2001 (0.10 +/- 0.013 km/h; Figure 4). In both years the proportion of fish that moved more than 0.2 km per 2-h interval was greater at night (mean = 45%) than during the day (mean 23%).

We were unable to detect an effect of flow on diel movement in either year when the effect of indi-vidual variation was controlled.

In 2001, flow fell within the lower 5th percentile of the 96-year historical daily flow level during 45% of the study period, and was less than the 96-year mean daily flow level during 98% of the study period (Figure 5). In 2002, flow fell within the lower 5th percentile of the 96-year historical daily flow level during 64% of the study period and was less than the 96-year mean daily flow level during 100% of the study period. Flow was greater in 2001 than in 2002, but most of the variation be-tween years was due to an early season rain event in 2001. No substantial rain events were recorded during the 2002 study period.

POPULATION SIZE AND MOVEMENT OF AMERICAN SHAD 305 400 350 300 250

~

.§. 200

~o u::

150 100 50 O+-----,r-----,----r-----,r----.-

3/15 3/30 4/14 4/29 5/14 5/29 Date FIGURE 5.-Flow from a U.S. Geological Survey gauge at the New Savannah Bluff Lock and Dam, Sa-vannah River. Light lines represent the 5th and 50th percentiles of historic flow,the heavy solid line repre-sents flow in 2001, and the heavy broken line represents flow in 2002.

In 200 I, 43 locking events for fish passage were completed between April 2 and May 21, while in 2002,47 locking events for fish passage were com-pleted between March 18 and May 29. Based on fish that remained in the tailrace or returned to the darn after transmitter implantation, a total of 30 (200 I) and 12 (2002) study fish could potentially pass through NSBLD. Of those, a higher percent-age offish were passed in 2001 than in 2002 (Table 3). Fish that did not pass upstream made several return trips to the area below the dam. However, we were unable to detect a relationship between the number of times fish returned to the area below the darn and passage. In 200 I, fish were passed during all times of lock operation. In 2002, the one fish passed moved through the lock at 1300 hours0.015 days <br />0.361 hours <br />0.00215 weeks <br />4.9465e-4 months <br />.

Although we tagged and examined a relatively large number of fish each year, relatively few fish were recaptured (Table 4). After adjusting for tag loss, mortality, differential migration, and report-ing rate, the population size of American shad near NSBLD was estimated at 157,685 (95% confi-dence interval [CI] = 82,654-259,365) in 2001 and as 217,077 (95% CI = 107,776-393,335) in 2002.

Discussion All but two fish moved downstream after trans-mitter implantation. This stress response to han-dling and transmitter implantation is referred to as fallback (Moser and Ross 1993). Past studies with American shad have attributed fallback to low wa-ter temperature (Moser and Ross 1993), poor con-dition of fish (Sparks and Hightower 1998), or a flight response due to handling (Barry and Kynard 1986). We observed a slightly higher frequency of mortality and transmitter rejection than has been observed in other telemetry studies of American shad using similar methods (Moser and Ross 1993; Beasley and Hightower 2000). High mortality in late-stage migrating American shad implanted with transmitters may be attributed to reduced en-ergy stores following migration (Glebe and Leg-gett 1981; Leonard and McCormick 1999). In 200 I, American shad implanted with radio trans-mitters and released earlier in the season exhibited a stronger fallback response and moved down-stream faster and further than fish released later.

These results are similar to those observed by Moser and Ross (1993) and are likely because of lower water temperature. However, this trend was TABLE 3.-Percentage (by year) of fish passed or not passed (95% confidence interval [ell) upstream through the navigation lock, mean number (range) of times fish returned to the area below the New Savannah Bluff Lock and Dam, mean number (range) of days fish spent in the area below the New Savannah Bluff Lock and Dam, and mean number (range) or days after implantation that fish passed successfully at the New Savannah Bluff Lock and Dam. Similar letters indicate no significant differences within columns.

Times Time since returned Residence implantation Year Passage N

Passage (%)

(d) time (d)

(d) 2001 Passed 16 z 53 (35-71) 1.3 (1-3) z 9.5 (1-28) z 17.9 (4-48)

Not passed 14 47 (29-65) 1.9 (1-9) z 9.6 (1-63) z 2002 Passed I y 9 (0-25)

I (1) 9 (9) 18 (36)

Not passed II 91 (75-100) 2.1 (1-8) 14.7 (2-36)

306 BAILEY ET AL.

TABLE 4.-Study year, marking period, recapture period, unadjusted number of fish marked (M), number of fish marked adjusted for mortality fallback and tag loss (Ma), number of fish examined for marks (C), unadjusted number of fish recaptured (R), number of fish recaptured adjusted for return rate (Ra), population estimate, and 95% confidence intervals (CIs) of population estimation for American shad at the New Savannah Bluff Lock and Dam.

Marking Recapture Year period (d) period (d)

M 2001 27 42 739 2002 23 42 812 451 357 c

3,337 5,152 R

9 8

Ra Estimated N 95% CI of N 9.54 157,685 82,654-259,365 8.48 217,077 107,776-393,335 not consistent between years. In 2002, fish moved downstream faster and further than in 2001, often moving beyond the routinely tracked area. Fish were also less likely to return to the dam in 2002.

While transmitter size was increased in 2002, it is unlikely this caused a major effect on differential migration. Transmitters represented less than 2%

of the body weight of the fish and are similar to transmitters used in other American shad telemetry studies (Sparks and Hightower 1998; Beasley and Hightower 2000). It is more likely that drought conditions resulted in flows that were insufficient to attract or retain fish at the dam.

Fish in this study were impeded from moving upstream to more suitable spawning habitat; there-fore, the limited movement observed was not un-expected. The observed movement was similar to the movement of American shad that have already reached their spawning grounds (Sparks and High-tower 1998; Beasley and Hightower 2000; Moser et al. 2000). In 200], the proportion of fish moving greater than 0.1 km/h was related to flow, but no effect was found in 2002. In 2002, flow never ap-proached the long-term mean seasonal flow, and thus could not be effectively evaluated. Move-ments over 5 km were often associated with re-location to a higher-use area or a return upstream after fallback. No late-season out-migration was observed, except when associated with fallback.

American shad in the Savannah River are assumed to be completely semelparous (Leggett and Car-scadden 1978); therefore, out-migration was not expected.

We observed American shad concentration in two areas. The first area was located just below the dam. American shad have been reported to use sand and gravel areas below an obstruction for spawning (Walburg and Nichols 1967; Beasley and Hightower 2000). As the area below the dam ap-peared to have suitable spawning substrate, fish were likely using this area for spawning as well as for staging prior to upstream migration at-tempts. The habitat in the area of the second con-centration of fish appears to be similar to that used by spawning shad in other rivers (Liem 1924; Wal-burg and Nichols 1967). The area had a slightly deeper main channel, and more expansive, shallow flats than did the adjacent reaches of the Savannah River. Fish were primarily located along current breaks in this stretch. American shad are known to prefer areas of reduced or nonturbulent flow for resting (Barry and Kynard ]986).

Continuous diel monitoring indicated that movements greater than 0.1 km/h were more fre-quent at night than during the day. The movements during the diel tracking periods were likely related to spawning and moving to areas of more suitable water velocity. American shad will use higher wa-ter velocity during the day than at night (Theiss

]997), but spawning is thought to occur mainly after sunset or on overcast afternoons (Liem 1924; Walburg and Nichols ]967). Some fish made re-peated long distance (>] km/h) movements that did not seem to be related to time of day. These fish may have been meandering in an attempt to find passage upstream.

Passage efficiency and numbers of implanted American shad returning to NSBLD was highest in the first year of study. Over 50% of the fish that returned to the dam were passed even though the lower gates were open for less than 15 h. This percentage represents remarkable passage effi-ciency when related to another lock structure that had lower gates open for well over 1,000 h (Moser et al. 2000). Although the locking season was ex-panded in 2002, low returns to the dam made pas-sage difficult to assess. Even the low percentage of fish that passed in 2002 (9%) represents a very high passage rate, as lower gates were open for less than 20 h. Passage and percentage of fish re-turning to the dam in either year compare favor-ably with the general range of passage in a similar study conducted on a low-elevation lock and dam system on the Cape Fear River, North Carolina (Moser et al. 2000).

The efficient passage at NSBLD may be due to the bottom topography of the area directly below the dam. A midchannel gravel bar splits the main

POPULATION SIZE AND MOVEMENT OF AMERICAN SHAD 307 channel into two smaller channels. The larger, deeper channel leads directly to the lock entrance.

American shad follow the main river channel dur-ing migration, often using the lower one-third of the water column (Witherell and Kynard 1990).

Barry and Kynard (1986) found that turbulent flows could confuse and deter fish from an area.

The turbulent flow within 30 m of the dam may have caused fish to repeatedly move downstream and upstream, increasing the time spent in the main channel. This orientation could lead to a higher probability of encountering the lock entrance and passing upstream.

In both years, the population size of American shad reaching NSBLD was similar. The population estimates for either year are similar to the Alta-maha River system (D. Harrison, Georgia De-partment of Natural Resources, personal commu-nication). Numbers of American shad reaching NSBLD were similar to the observed numbers at a fish lift in South Carolina (Cooke and Leach 2002); however, those values are highly variable and were assessed by numbers of fish that suc-cessfully pass through the lock. Mark-recapture studies on migrating fish are inherently difficult because of high interannual variation, difficulties in capture, and potential biases. Most mark-re-capture studies are conducted in cooperation with commercial gill-net fisheries, and often assess all fish that enter rivers, not only those that reach spawning grounds.

Mark-recapture studies, in conjunction with telemetry, are valuable to the as-sessment of differential movement and may pro-vide more realistic estimates of populations.

Acknowledgments This study was funded through grants from the U.S. Fish and Wildlife Service, South Carolina Department of Natural Resources, and the South Carolina Cooperative Fish and Wildlife Research Unit. We thank the U.S. Army Corps of Engineers for providing access to the facility. Cooperating agencies for the South Carolina Cooperative Fish and Wildlife Research Unit are the U.S. Geological Survey, Clemson University, the South Carolina Department of Natural Resources, and the Wildlife Management Institute.

References Barry, T., and B. Kynard. 1986. Attraction of adult American shad to fish lifts at Holyoke Dam, Con-necticut River. North American Journal of Fisheries Management 6:233-241.

Beasley, C. A., and J. E. Hightower. 2000. Effects of a low-head dam on the distribution and characteristics of spawning habitat used by striped bass and Amer-ican shad. Transactions of the American Fisheries Society 129: 1316-1330.

Bigelow, H. B., and W. C. Schroeder. 1953. Fishes of the Gulf of Maine. Fishery Bulletin 53:1-577.

Chappelear, S. J., and D. W. Cooke. 1994. Blueback herring behavior in the tailrace of the St. Steven dam and fish lock. Pages 108-112 in J. E. Cooper, R. T. Eades, R. J. Klauda, and J. G. Loesch, editors.

Anadromous Alosa Symposium. American Fisheries Society, Tidewater Chapter, Bethesda, Maryland.

Cooke, D. W., and S. D. Leach. 2002. Santee-Cooper anadromous fish studies. South Carolina Depart-ment of Natural Resources, Annual Progress Report SCR 1-22, Columbia.

Glebe, B. D., and W. C. Leggett. 1981. Latitudinal dif-ferences in energy allocation and use during the freshwater migrations of American shad (Alosa sap-idissima) and their life history consequences. Ca-nadian Journal of Fisheries and Aquatic Sciences 38:806-820.

Leggett, W. c., and J. E. Carscadden. 1978. Latitudinal variation in reproductive characteristics of Ameri-can shad (Alosa sapidissima): evidence for popu-lation-specific life history strategies in fish. Journal of the Fisheries Research Board Canada 35: 1469-1478.

Leggett, W. C., and R. R. Whitney. 1972. Water tem-perature and the migrations of American shad. Fish-ery Bulletin 70:659-670.

Leonard, J. B. K., and S. D. McCormick. 1999. Effects of migration distance on whole-body and tissue-specific energy use in American shad (Alosa sapi-dissima). Canadian Journal of Fisheries and Aquatic Sciences 56:1159-1171.

Liem, A. H. 1924. The life history of the shad (Alosa sapidissima) with special reference to the factors limiting its abundance. Contributions of Canadian Biology New Series 2:163-284.

Malvestuto, S. P. 1983. Sampling the recreational fish-ery. Pages 397-419 in L. A. Nielsen and D. L. John-son, editors. Fisheries techniques. American Fish-eries Society, Bethesda, Maryland.

Moser, M. L., A. M. Darazsdi, and J. R. Hall. 2000.

Improving passage efficiency of adult American shad at low-elevation dams with navigation locks.

North American Journal of Fisheries Management 20:376-385.

Moser, M. L., and S. W. Ross. 1993. Distribution and movements of anadromous fishes of the lower Cape Fear River, North Carolina. Final Report to U.S.

Army Corps of Engineers, Wilmington, North Car-olina.

Nichols, P. R., and D. E. Louder. 1970. Upstream pas-sage of anadromous fish through navigation locks and use of the stream for nursery and spawning habitat, Cape Fear River, North Carolina, 1962-1966. U.S. Fish and Wildlife Service Circular 352.

Pegg, M. A., P. W. Bettoli, and J. B. Layzer. 1997. Move-ment of saugers in the lower Tennessee River de-termined by radio telemetry: implications for man-

308 BAILEY ET AL.

agement. North American Journal of Fisheries Man-agement 17:763-768.

Ricker, W. E. 1975. Computation and interpretation of biological statistics of fish populations. Fisheries Research Board of Canada Bulletin 191.

Rulifson, R. A. 1994. Status of anadromous Alosa along the East Coast of North America. Pages 134-158 in J. E. Cooper, R. T. Eades, R. J. Klauda, and J.

G. Loesch, editors. Anadromous Alosa Symposium.

American Fisheries Society, Tidewater Chapter, Be-thesda, Maryland.

Sparks, K. L., and J. E. Hightower. 1998. Identification of major spawning habitats used by American shad (Alosa sapidissima) in the Roanoke River, North Carolina. Final Report to the U.S. Fish and Wildlife Service and Virginia Power, Raleigh, North Caro-lina.

Stevenson, C. H. 1899. The shad fisheries of the Atlantic Coast of the United States. Pages 101-269 in G. M.

Gowers, editor. Report of the U.S. Commission of Fish and Fisheries, part 24. U.S. Commission of Fish and Fisheries, Washington, D.C.

Theiss, E. J. 1997. Effect of illumination intensity on the water velocity preference of three Alosa species.

Master's thesis. University of Massachusetts, Am-herst.

Walburg, C. H., and R. P. Nichols. 1967. Biology and management of the American shad and status of the fisheries: Atlantic Coast of the United States, 1960.

U.S. Fish and Wildlife Service Special Scientific Report: Fisheries 550, Washington, D.C.

Witherell, D. B., and B. Kynard. 1990. Vertical distri-bution of adult American shad in the Connecticut River. Transactions of the American Fisheries So-ciety 119:151-155.