DESCRIPTION OF TELEP110NE SERVICE FOR THE

~

INCIDENT RESPONSE CENTER

~

OF THE NUCLEAR REGULATORY AGENCY 9

1 l

I s

i 19 July 1978 t

i f

t 1

O sootsi' O 2

- ~

i

~

o

e INTRODUCTION The Nuclear Regulatory Commission is equipping an Incident Response Center (IRC) in the East-West Tower Building in Bethesda, Maryland. Telephone communications will be required as an integral part of operations.

CENTREX FEATURES i

The following Centrex II features, which are available on the NRC Centrex, will be utilized.

Consultation hold - all calls Add-on conference - all calls Call transfer - all calls (r*<\\

Speed calling - mnpersand plus two digits

\\s_s!

Automatic privacy exclusion (one line only)

OTHER ' FEATURES Additional features to be provided by the telephone company are listed below.

Multichannel Voice Recording Interface f

.The 18 lines listed in Table 2 for station YY are to interface with multichannel recorders. The recorders I

will be provided by the Government.

Single Channel Voice Recording Jacks A modular jack will be provided on each subscriber set for plugging in a single channel recorder.

In addition, jacks will be provided on two key strips (stations N and P, 1

ss

_-v 4

3

l 4

Table 2) for reccrding any lines selectable at these stations.

i Headsets and Headset Jacks

)

Starsets and appropriate jacks will be provided on selected subscriber sets (.=ce Table 2). When the Starset is plugged in, the handset will be disabled.

Conference Bridges i

No conference bridges other than those currently available to the NRC will be required.

Microphone / Speaker System Interface A 4-wire line will be provided to interface with a government-supplied microphone / speaker system (see Stations Z and WW, Table 2). The Centrex " Automatic Privacy Exclusion" will be provided for this line.

Speake rphone One speakerphone will be provided (station B, see Table 2).

Manual Intercom System

~

A manual intercom system to be controlled by the Operations Room Assistant (ORA) will be provided. A common talk path will be terminated at each subscriber set. The ORA will be able to signal any subscriber position by pushing a button which causes a green light located near the subscriber set to flash. The ORA will also be able to operate two audible signals (one in the Operations Room and one in the Executive Room).

2

(

Slow-scan TV Interface An interface for a Government-supplied slow-scan TV system will be provided (see Station ZZ, Table 2).

Restricted Lines Certain designated lines will be restricted to internal NRC calls only.

(See Table 3)

LAY 0tTT OF TELCO EQUIPMENT l

i The telephone stations and their locations are indicated in Figure 1.

Table 1 associates stations with IRC operational positions. The location of telephone equipment in the IRC may change; therefore, the telephone installation should afford some flexibility for future change,s and expansion.

STATION DESCRIPTIONS All subscriber sets shall be beige Slimline telephones with Touchtone dialing. Station equipment and corresponding key assignments are listed in Table 2.

LINE ASSIGNMENTS Table 3 shows the assignment of each line to subscriber sets.

Lines 1 to IS are outside lines assigned to the main rotary off the NRC emergency number.

._nes 20 and 21 are outside lines assigned to s.n emergency number for access to the IRC by selected individuals through a separate rotary. Lines 22 to 28 are outside lines not assigned to citScr rotary.

~ ~,,

1 l

e j

i i @

\\

t t

F 4

i i

Lines 30 to 40 are to be restricted such that calls outside t

l l

NRC cannot be placed on these lines. The pick-up keys for i

l l

these restricted lines shall be a color different from the color of the other pick-up keys.

I 1

The assignment of speed calling numbers to telephone lines l

is provided in Table 4.

,1 i

i i

1 e

l ~

6 I i i

I S.

}

,t t

i

,l t

i 1

i.

l t

l I

t l

r I

t 1

I e

l

.. - - - - -. - -. -.-.- - -,- n -,-

-,,,,-,n...-,--,,--_

n_-,


,w,---.

... ~ - - -, -

/

b

/

C l/,

/

ZZ 0 R S 1

.v 4(

M z

M OOR T

1 U

E O

V U V wx E

Y I

R A

T U

L U

G C

I C

E F

R X

I E

S A

/,

/

/

/

ER L

A G.

K R

OW C

j

{

J K

W i

E D

^

F i

e i

n i

X M

X OO G

R

/

S E/

t

-I N

E O

R A I

U E C '<

H TA p(,,

P EP O

s i4 b

,u l;

l

i

\\

TABLE 1 l

TELEP110NE SUBSCRIBER.TGITIONS IN IRC i

l (Refer to Figure 1) i Operations Room Subscriber Subscriber Number Name i

A Liaison Officer B

Field Liaison a

C XOOS/ Administrative Officer D 'l E

l' F\\

Staff Advisors i

G H{

l l

Ij l

Jl Emergency Phones-Work Area i.

KJ L'{

Non-Er..crgency Phones Mf f

N Single Channel Recorder Channel Selector P

0 Operations Room Assistant P*

Q R

S l

T Executive Team Members U

V i

W I

X Y.

Z Executive Team Director 6

b

.,--,.,,,,,..,--,.--.n

_ _.,._._. _ _ _ _.. _, - - - - - - ~ - - - _..

}.,,

. - = -.

l i

1 l

4 I

t i e l

TABLE 1 1,

(continued) t t

Operations Room Subscriber Subscriber Number Name i

ZZ Slow Scan TV YY Multichannel Recorder i

Location reserved for facsimile if XX I

procured at a later date.

i 4-wire termination for microphone /

l W

speaker system i

9 9

~

l b

l I

4

--.---,--~..--~~--n,.-..n,,

.,,,-v_ne,-----------,-

-n. -.- - - - - - -.

,+

\\

TABLE 2 STATI0'4/ KEY ASSIGN!'ENTS Station A: Dil D 5, 6, 15, 16, 17, 30, PL, MI (12-button) w/ headset jack and Starset; extra long cord Station B: TML D 5, 6,15,16,17, 33, 34, 35, 36, PL, MI(12-button) w/ speaker phone; headset jack and Starset; extra long cord Station C: TML D 5, 6, 22, 32, MI

( 6-button) w/ extra long. cord Station D: TML D 5, 6, 7, 33, MI

( 6-button) w/ extra long cord Station E: DIL M 5, 6, 7, 33, 34, 35, 36, MI (12-button) w/ extra long cord Station F: TML W 5, 6, 7, 33, 34, 35, 36, MI (12-button) w/ extra long cord Station G: TML W 5, 6, 8, 33, 34, 35, 36, MI (12-button) w/ extra long cord Station H: TML W 5, 6, 8, 33, 34, 35, 36, MI (12-button) w/ extra long cord Station I: Blb D 5, 6, 8, 34, MI

( 6-button) w/ extra long cord Station J: TML D 5, 6, 7, 33, 34, 35, 36, MI (12-button) w/ extra long cord Station K: TML D 5, 6, 8, 33, 34, 35, 36, MI (12-button) w/ extra long cord Station L: Standard NRC telephone - regular centrex number (single line) w/ extra long cord Station M: Standard NRC telephone - regular centrex number (single line) w/ extra long cord Station N: Single-channel recorder 5, 6, 15, 16, 17, 30, 33, 34, 35, 36 (12-button selector strip w/ modular jack) 8 w/

N

b TAB LE 2 (continued)

Station 0: 2 call directors in parallel; 30 button each: 1-15 inclusive; 20-24 inclusive; 30, 31, MI P LUS : MI indicator light control panel (21 lights)

Station P: Single-channel recorder 5, 6, 15, 16, 17, 30, 33, 34, 35, 36 (12-button selector strip w/ modular jack)

Station Q: TML D 9, 10, 37, 38, MI

( 6-button) w/ extra long cord Station R: TML D 9, 10, 37, 38, MI

( 6-button) w/ extra long cord Station S: TML D 9, 10, 37, 38, MI

( 6-button) w/ extra long cord Station T: TML D 9, 10, 37, 38, MI

( 6-button) w/ extra long cord "N

Station U: TML D 9, 10, 39, 40, MI

( 6-button) w/ extra long cord l

l Station V: TML D 9, 10, 39, 40, MI

( 6-button) w/ extra long cord Station W: TML D 9, 10, 39, 40, MI

( 6-button) w/ extra long cord Station X: TML D 9, 10, 39, 40, MI

( 6-button) w/ extra long cord Station Y: TML D 9, 10,'37, 38, MI

( 6-button) w/ extra long cord Station Z: TML D 9, 10, 11, 12, 39, 40, 24, PL, MI (12-button) m w/ extra long cord Note:

Line 24 is 4-wire with automatic privacy exclusion feature and is to interface with customer owned and maintained microphone and speaker.

Station ZZ: Termination for slow-scan TV 1

Station YY: Multi-channel recorder 5 to 15; 20-24; and 2 from ORA station I

j (s_,,

Station WW:

4-wire connectors for microphone / speaker system

"'n

TAB 12 2 (continued)

NOTE: PL = Private Line MI = Manual Intercom Main Rotary Numbers = 1-15 inclusive Outside, Non-Rotary = 22-28 inclusive Restricted, NRC Only = 30-40 inclusive VIP Rotary - lines 20 and 21 i

I e

d 4

e I

l l

I 10 a.

..._..---_,_m. _ _,

.--m--

1 i

TABLE 3 LINE ASSIGNMENTS l

Main Rotary j

Outside Line Number Subscriber Set g.

2, 0

l 31 I

4 j

S A,B,C,D,E,F,G,H,I,J,K (Common-Ops Room) 6 7

D,E, F,J 8

G,H,I,K, 9$

Q,R,S,T,U,V,W,X,Y,Z, (Common-Exec Room) 10) l i

11{

Z 12) i l

'13 )

A,B 14(

i 15) l Non-Main Rotary Outside Line Number Subscriber Set t

1 20 VIP Incoming Lines (Separate rotary) 21 1

22{

ORA /Comm Officer Outgoing Lines l

23) j 24 Microphone / Speaker System, Exec Room 25{

Slow Scan TV 26J l

27{

Non-Emergency NRC Cdntrex 28) l l

11

'N

i l

l 0

TABLE 3 (continued) j Restricted Inside Lino Numbers

' Subscriber Set I

[

30 A,0 31 0

32 C

33 B,D,E,F,G,H,J,K 34 B,E,F,G,H,I,J,K 35{

B,E,F,G,H,J,K 36f

}

37{

Q,R,S,T,Y O

38f i

,39{

U,V,W,X,Z l

40J 4

1 i

I l

9 Y

O 12 b,

q. -,=-,- e -w rw

-*--'w

-vw w w -t - w w i- "e * ---

+we -

- = = ' - - ~ ~ - - * - - * + -

i r

o e

e i

i t

TABLE 4 l

I l

SPEED CALLING NIAISER ASSIGNMENTS l

l i

Line Speed Calling l

t Number Number 5

20 i

I 6

21 l

7 22 j.

8 23 f

9 41 10 42 11 43 12 44 13 24 14 25 9

15 26 24 40 31 30 31 30 32 34 33 35 34 36 35 32 36 33 37 43 38 44 39 41 40 42

+

13 N