Agrees w/800122 Suggestion That Issue of Automatic Manual Operator Action Be Included in TMI-2 Action Plan to Develop Criteria for Determining Which Safety Action Should Be Performed
ML19275D944
Person / Time
Issue date: 02/12/1980
From: Mattson R
NRC - TMI-2 OPERATIONS/SUPPORT TASK FORCE
To: Moore V
Office of Nuclear Reactor Regulation
Shared Package
ML19239A281 List:
References
FOIA-81-405 NUDOCS 8005140681
Download: ML19275D944 (1)


Text

Distribution:

800514065%

Central File -

NRR R/F DSS R/F JMilhoan RMattson FE3 I2 ggg FEMORAtt0VH FOR: Voss A. Hoore, Acting Assistant Director for Plant Systems FROM:

Roger J. Mattson, Director

-y - -

--THI Action flan Steering Group

SUBJECT:

TMI TASK ACTION PLAhS - CRITERIA FOR AUTOMATIC AND PM UAL ACTIONS Your note of January 22, 1900 to me briefly discussed the subject of automatic versus manual (operator) action.

You stated that a task shoulo be included in the THI-2. Action to develop criteria for determining which safety actions should be performed automatically and which should be manual actions.

l_

I agree with you that the subject of manual versus automatic actions is an important topic that deserves coverage in the Action Plan. The TMI-2 Action Plan Steering Group has addressed the subject in Section I.A.4.2 subitem (b)

" Safety-Related Operator Action." One of the tasks is to develop reconmendations relative to the degree of auto-mation that should accompany the activation and operation of engineered safety features as well as the resulting information display.

By a copy of this memo, I am forwarding your note of January 22, 1979 to J. P. O'Reilly, Chapter tiead for Chapter 1, and D. Skovholt, Task Manager for Section I.A, requesting that they revise subitem (b) of Section I.A.4.2 to core clearly address the subject o,f criteria for automatic and manual actions.

Original signed by Roger J. Mattson Roger J. Mattson, Director THI Action Plan Steering Group R. Satterfield

~..