05000298/LER-1979-026-03, /03L-0:on 790912,investigation Found Unidentified Drywell Leak on Reactor Recirculation Pump B.Caused by Failure of Pump Seal at Natural End of Life.Seal Replaced.No Further Action Planned

From kanterella
(Redirected from ML19250C034)
Jump to navigation Jump to search
/03L-0:on 790912,investigation Found Unidentified Drywell Leak on Reactor Recirculation Pump B.Caused by Failure of Pump Seal at Natural End of Life.Seal Replaced.No Further Action Planned
ML19250C034
Person / Time
Site: Cooper Entergy icon.png
Issue date: 10/09/1979
From: Flannigan R
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19250C026 List:
References
LER-79-026-03L, LER-79-26-3L, NUDOCS 7911060419
Download: ML19250C034 (1)


LER-1979-026, /03L-0:on 790912,investigation Found Unidentified Drywell Leak on Reactor Recirculation Pump B.Caused by Failure of Pump Seal at Natural End of Life.Seal Replaced.No Further Action Planned
Event date:
Report date:
2981979026R03 - NRC Website