05000317/LER-1979-048-03, /03L-0:on 790914,during Surveillance Test, Containment Spray Pump 12 Tripped on Ground Overcurrent. Caused by Motor Stator Coils Chafing Against Incoming Phase Lead,Thus Developing Short Circuits at Coil End

From kanterella
(Redirected from ML19249F324)
Jump to navigation Jump to search
/03L-0:on 790914,during Surveillance Test, Containment Spray Pump 12 Tripped on Ground Overcurrent. Caused by Motor Stator Coils Chafing Against Incoming Phase Lead,Thus Developing Short Circuits at Coil End
ML19249F324
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 10/04/1979
From: Bauer E, Davis S
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19249F322 List:
References
LER-79-048-03L, LER-79-48-3L, NUDOCS 7910110313
Download: ML19249F324 (1)


LER-1979-048, /03L-0:on 790914,during Surveillance Test, Containment Spray Pump 12 Tripped on Ground Overcurrent. Caused by Motor Stator Coils Chafing Against Incoming Phase Lead,Thus Developing Short Circuits at Coil End
Event date:
Report date:
3171979048R03 - NRC Website

text