05000333/LER-1979-065-03, /03L-0:on 790907,rod Sequence Control Sys Failed, Not Allowing Normal Control Rod Insertion or Withdrawal. Caused by Failed Relay on One Printed Circuit Board. Replacement of Relay Restored Normal Operation of Sys

From kanterella
(Redirected from ML19209B783)
Jump to navigation Jump to search
/03L-0:on 790907,rod Sequence Control Sys Failed, Not Allowing Normal Control Rod Insertion or Withdrawal. Caused by Failed Relay on One Printed Circuit Board. Replacement of Relay Restored Normal Operation of Sys
ML19209B783
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 10/04/1979
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19209B781 List:
References
LER-79-065-03L, NUDOCS 7910100453
Download: ML19209B783 (2)


LER-1979-065, /03L-0:on 790907,rod Sequence Control Sys Failed, Not Allowing Normal Control Rod Insertion or Withdrawal. Caused by Failed Relay on One Printed Circuit Board. Replacement of Relay Restored Normal Operation of Sys
Event date:
Report date:
3331979065R03 - NRC Website

text

U. s. NUGLhAH HkGULAT OR Y COMMISSION 17 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l ljh PLEASE PRINT OR TYPE ALL REQlllRED INFORMATION) i e

i l ! ?1 l Y l J l A l F l 1 l@l 01 Ol -

0 l 0l 0l 0 l - l 0 l O l O l@l 4 l l i 11 1 l 1 @l l

l@

o 7

8 9 LICENSEE CODE le 15 LICENSE NuvdEH 2b 26 UCENSE TYPE Jo

$ 7 C A T bd CON'T E'R$ ll l@l0151010101313 l3 l@l 019101717191@l 110101417 l 9 l@

o i

l 8

60 61 DOCKET NUYaER 68 63 EVENT DATE 74 75 REPORT D ATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h o

2 l SEE ATTACHMEf1T I

O 3 l l

10141 l i

O S l l

l0 l6 l l l

0 7

l 0

8 l

l 7

8 9 80 SYSTEM

CAUSE

CAUSE COVP.

VALVE CODE CODE SU8 CODE COYPONENT CODE SUBCODE SU8 CODE 1 R I B l@ W@ l E l@ l I l N l S l T l R l U l@ l XI@ L_(J @

o 9

?

d 9

10 11 12 13 18 19 20 SEOUEN TI AL OCCURRENCE REPOPT REVISION L

EVENT YE AR REPORT NO.

CODE TYPE N O.

@ yu'E R ROI7l9l l'

l0 615l l/l 013 l lLl

[_]

I Ol a Qa;

_ 21 22 23 24 26 27 28 29 30 31 32 TAKEf A TO ON PLANT T

HOURS SB IT D FOR b B.

SUPPLIE MANUFACTURER I A l@l]_]@

l 21@

L3JO 101010101 LYJ@

IV @

IN l@

l G l0 18 10 l(

33 34 35 36 31 40 4i 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i

o l SEE ATTACHMENT 1

li lil I I

l i

ai i i

l i 141 1 1

7 8 9 80 ST US

  • POW E R OTHER STA TUS DISCOV H DISCOVERY DESCRIPTION l Cl @ l0 0l2l@

NA l

l A l@l Operator Observation l

i s

A!TiviTv CO3 TENT 8

RFLE ASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE Q @ l 2 l@l tJA I

I NA i

c 7

is 9 10 11 44 45 PERSONNEL EXPOSURES 80 NUV8ER TYPE D E SC RIP TION 10l010]@l_Zj@lNA i

i l

' PERSONNE t iNau' RIES 2

DESCniPTiON@

NuveER 7

r 10 01 0l@l NA J9 4 a2 i

a i

7 8 9 11 12 LOSS OF OR DAVAGE TO FACILITY 80 TYPE D E SCRIP TION v

L' L_J Z l@l NA 7 _

d 9 10 ISSUE

DESCRIPTION

12101 LrL[@l NA I

i llIIllll1Ii15 7

8 9 10 68 69 80 3 W. V. Childs NAME OF PREPARER (315)342-3840 o

PHONE:

7 910100 MB

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT DOCKET N0. 50-333 ATTACHMENT TO LER 79-065/03L-0 Page 1 of 1 During normal startup operations, the Rod Sequence Control System failed in such a manner as to not allow normal control rod insertion or with-drawal. The scram function for control rods remained unaffected. The lied Sequence Control System maintained control of the rod withdrawal st:quence by not allowing any motion, thus the system performed its ir. tended function as required by Technical Specifications Appendix A, Paragraph 3.3.B.3.a.

Since the Rod Sequence Control System maintained control of the withdrawal sequence as noted above, the event did not represent a significant hazard to public health and safety.

Investigation revealed a failed relay on one of the printed circuit boards associated with Control Rod Group 3.

Replacement of the relay restored normal operation of the system.

1139 153