05000321/LER-1979-066-01, /0T-0:on 790827,following Refueling Outage, Routine Surveillance Revealed Jet Pump Integrity Not Performed Satisfactorily on 790826.Caused by Personnel Not Recognizing Limiting Conditions for Operation

From kanterella
(Redirected from ML19207C001)
Jump to navigation Jump to search
/0T-0:on 790827,following Refueling Outage, Routine Surveillance Revealed Jet Pump Integrity Not Performed Satisfactorily on 790826.Caused by Personnel Not Recognizing Limiting Conditions for Operation
ML19207C001
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 09/04/1979
From: Baxley S
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19207B994 List:
References
LER-79-066-01T, LER-79-66-1T, NUDOCS 7909060292
Download: ML19207C001 (2)


LER-1979-066, /0T-0:on 790827,following Refueling Outage, Routine Surveillance Revealed Jet Pump Integrity Not Performed Satisfactorily on 790826.Caused by Personnel Not Recognizing Limiting Conditions for Operation
Event date:
Report date:
3211979066R01 - NRC Website

text

u. s t.uctun atcut,oony ccw,ss:a.4 rm e i onr.is.;G (1 77)

LICENSEE EVENT 1 EFORT ccNTnot etccx:

_U

[

l (PLE ASE PRINT OR 1YPE ALL REQUlot D INF ORfAATION)

R (G_IA lE jI lH ))_j@[0_] O I - 10 l 0 l 0 l 0 l 0 l - l 0 l 0 l@ 411 l 1 [lj_LJOL_LJ @

LIC L ?.'.L T Y P E JJ

' 7 L,g I M J.

51 9

L l',, t t. "A t C Q ;, L 14 Pe l lC L t st f.UUGt H n

.t2 CL, I ITTil

,ll?,"C [L_j@ 0] 5 l 0101013 l 211 Gl 0 I 8 IM717 l 9 !@l 019 I O l 4 I 7 4j@

841 t,3 LVENT D ATL 18 i 's HLPurtT CAT E 60 I

d v) ts i L C,; =, t 1 N L WI L H EvcNT occcRieTio a ANo encunt r ccmtcurNcts @

l [O

- 1 lDuring steady state operation at low power for Startup testing following a Refue ing l0utage, rs. tine surveillance review revealed that HNP-1-9400 (Jet Pump Integrity) had i

o [n W [not beu performed satisfactorily on 8-26-79.

Procedure had been performed, but was

]

O,s l unacceptable. Test Shop began calibration of instruments so that Procedure could be j

o icj [ performed again to insure accurate readings.

Tech. Specs. 3.6.I requires Plant to be [TJT] [in the Cold Shutoown Mode within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Failure to comply with Shu tdown requirementp,

g gas not recognized until morning of 8-27-79.

Operations immediately performed 7

8 9 COYP velvr Sy:T r st CAUtr C Al f;E CSDC CCLt C'kCi at CO'PONEN1 CCLE SUSCODE SUCCOLE [Q

Rl Al@ l Al@ l A l@ [Z lZ lZ lZ IZ IZ l@ [Zj@ [Z j @

7 8

9 10 11 12 12 14 19 W_

" O' ?E N f1 A L OCCUR R f NCE r< r 6 OH T RCVIStON f Vf NT Yf / A f IFOH T !.a CCOE TYiE No.

L E it 40

@ 0,jl.y [v7 19 ]

l-l 10 l6 l 6 l kJ l 0l 1J lTl ll l0 l u

n 2s a

2r a

n au a,

n AC Y i n N FUTUvi 5FFECT SH u T O NJ AlrAcuv'N1

  • . HD4 E nlM CCW COS IPCNTN T UaMITIED FGHM LU3.

' UF'lif H MANUT AC D'F,f it TANtN ACTICN GN FLA *J T 1.1E l H UD HOUHL Lilj@LZ j@

lZl@

[ Z_J@

1010 l 0 ! 0 l [Lj@

IN l@

]Z lQ [Z ] 91919l@

,/

43 41

.s j 43 44 47 J3 4

24 a

s c AucE cECRIPUoN Af D CohPECUVE ACUCNS @

li;o Plant personnel f ailed to recognize that IC0 existed.

Instrument calibration was sus-i W joccted and Procedure was expected to be acceptable when instrument calibration was ccm-;

laI?] plete.

Immediately upon discovery Procedure HNP-1-9400 was performed and was acceptably.

l Balancing of RECIRC loop flow had placed Procedure in acceptable status.

Jet Pump In-l 3

[i i. j lteority had existed since Plant Startup and Procedure was made unacceptable only be-l Ea 7

8 9

% PCM H Q1HC ft ST ATUS

' 15 f '

or,00VE RY DEECittPTION SIA '>

LCj@ l 0 l 0 l 6 l@l NA l

l A l@lPLANT PERSONNEL OBSERVATION l

i s

'6

,C\\viry Cc'T!r r NT toCAno ior nutet @

mount Os 4CuviTy @ l mtmto cr muce NA l

NA l

li I6] [2_j @ l Z j g j 7

b 9 10 11 44 4'a w

P( H',0?. 'J E l E A PO".Uf t C S [il 7l l 0l 0 Oj@jZ1YPt@ltte,Chietion NUWE R NA l

m 11 t

1J n~so. m.mma',s m,..,,o.,

7 8 9 cm,mpuoN@

g.77 M*' 9n=M? '^""" @

70090602M "

e,

,2 NA l

I' l~Il @ @[

U i

e 9 m

rme int vaty omonn.@

PtJI;L LCI T Y LI I I 1 LLL1 ! I ' I!

...o r n_k I

O a$

cs o S. X. Baxley eno,ac(412) 367-7781 n,

twae cF Par eAm

EVEllT DE_SCRIPTION A@ PROMflLE C0!!SEQUEf'CES (C0t!'T.1 S

HilP-1-9400 and it was acceptable.

There was no effect on public health or safety.

CAUSE

DES _QRIPTIOf' AND_ CORRECTIVE ACTIONS (C0ti'T.)

cause of unbalanced loop flow conditions.

Plant personnel have been instructed to insure that Tech Spec. requirements are performed within prescribed limits.

9.:ses.3