ML19098A151

From kanterella
Jump to navigation Jump to search
Appendix H, Daily Report - UNC_Daily_Report_109_20170817
ML19098A151
Person / Time
Site: 07000371
Issue date: 03/01/2018
From:
Cabrera Services
To:
NRC Region 1
Shared Package
ml051740240 List: ... further results
References
Download: ML19098A151 (7)


Text

OP 359, Field Activity Documentation CABRERA DAILY REPORT

1. PROJECT INFORMATION PROJECT NAME/LOCATION: SUPPLEMENTAL RADIOLOGICAL SURVEY Former UNC Manufacturing Facility, New Haven, CT DATE: 08/17/17 REPORT NO. 109 CONTRACT #:

CABRERA PROJECT #: 10-1007.00 TASK #: 016 FIELD SITE MANAGER: Mike Plonski PROJECT MANAGER: Rob Flowers

2. WEATHER TEMPERATURE RANGE: 63-85 degrees F WIND SPEED/DIRECTION: 5-15 mph E PRECIPITATION LAST 24 HOURS:

YES NO TYPE: N/A AMOUNT: 0.00 BAROMETRIC PRESSURE: 29.71 HUMIDITY: 70-100%

HEAT INDEX RANGE: N/A WEATHER DELAYS:

YES NO DELAY TIME (HOURS): N/A

3.

SUMMARY

OF WORK Conducted safety meeting prior to beginning field activities.

Completed daily quality control checks on radiological counting instrumentation.

Elevated work platform and fall protection training with S. Liddy.

Continued wall surveys in the central portion of 3H.

4. MATERIALS & EQUIPMENT BROUGHT ON-SITE Receipt inspection required & completed?

Yes No

5. INSPECTIONS TYPE DESCRIPTION ACTION PREPARATORY INITIAL FOLLOW-UP ARE ANY DEFICIENCIES NOTED IN FOLLOW-UP INSPECTIONS?

YES NO

6. DEFICIENCIES CORRECTED DEFICIENCY #

REPORT REFERENCE DESCRIPTION ACTION

7. TESTS PERFORMED SPECIFICATION REFERENCE TYPE TEST & RESULT ARE TEST RESULTS ATTACHED?

YES NO NA - IF NO, EXPLAIN:

8. CABRERA PERSONNEL ON-SITE EMPLOYEE NAME TITLE TASK(S) PERFORMED Mike Plonski SRSL/OSLM See Section 3 Summary of Work (8 Hrs)

Bethany Galivon HPT See Section 3 Summary of Work (8 Hrs)

Ginger Sparks HPT See Section 3 Summary of Work (8 Hrs)

Rob Gionfriddo HPT See Section 3 Summary of Work (8 Hrs)

Sean Liddy OHS/QAM See Section 3 Summary of Work (6 Hrs)

9. SUBCONTRACTOR PERSONNEL ON-SITE SUBCONTRACTOR NAME JOB DUTY TASK(S) PERFORMED
  1. OF PERSONNEL MAN-HOURS TOTALS
10. EQUIPMENT & MATERIALS ON-SITE VENDOR EQUIPMENT SERIAL #.

ACTIVE OR IDLE DATE RECEIVED DATE RETURNED ERG 1 Ludlum 2360 scaler/rate meter with 43-93 Zinc sulphide scintillation probe 184909/

PR298426 Active 02/21/2017 ERG 1 Ludlum 2360 scaler/rate meter with 43-93 zinc sulphide scintillation probe 193638/

PR199836 Active 02/21/2017 ERG 1 Ludlum 2360 scaler/rate meter 220242 Active 02/21/2017 ERG 1 Ludlum 2221 scaler/ digital rate meter with FIDLER sodium iodide scintillation probe 190205/

PR01807D Active 02/21/2017 ERG 1 Ludlum 2929 scaler sample counter with 43-10-1 zinc sulphide scintillation probe 200051/

PR215948 Active 02/21/2017 ERG 1 Ludlum model 12 meter with 44-9 Geiger-Mueller probe 276863/

PR147787 Active 02/21/2017 ERG Escort ELF Lapel Air sampler A3-48588 02/21/2017 ERG 1 MircoRem meter 2079 02/21/2017 ERG 1 Low volume air sampler 02/21/2017 ERG 1 Low volume air sampler 02/21/2017 Cabrera 1 Th-230 check source 5648-06 Active 02/21/2017 Cabrera 1 Tc-99 check source 5634-05 Active 02/21/2017 Cabrera 1 Co-60 check source 267D21 Active 02/21/2017 Cabrera 1 Ludlum model 2224-1 scaler/rate meter with 43-93 Zinc sulphide scintillation probe 227246/

PR244549 Active 02/21/2017 Cabrera 1 Ludlum Model 3 rate meter with 44-9 Geiger-Mueller probe 219266/

PR Active 02/21/2017 Canberra Gamma Spectroscopy Instrument (Canberra REGe)

SN 8381 Active 03/06/2017 United Rentals 1 Bobcat T5 90 Skid Steer Active 02/21/2017 United Rentals 1 set of forks, and 1 grapple bucket for Skid Steer Active 02/21/2017 United Rentals 1 Magnum 130 tow behind generator 02/21/2017 6/6/2017 NEMF Wheel Scale 02/21/2017 6/20/2017 Williams Scotsman 1 8 by 20 connex box Active 06/22/2016 United Rentals Scaffold 03/23/2017 5/23/2017 Cabrera 1 heater 03/23/2017 United Rentals 2 Scissor Lifts N80011/N8 9812 Active 8/14/207

11. MATERIAL GENERATED/STORED ON-SITE MATERIAL ID SOLID, LIQUID, OR MIXED DESCRIPTION OF MATERIAL CONTAINER TYPE DISPOSITION OR LOCATION OF MATERIAL AMOUNT*

(CY OR TONS)

ERRU000312 Solid Soil/ Garbage/ Debris/

ACM Intermodal Building 3H

~12.34 Tons MHFU-002362 Solid Soil/ Garbage/ Debris/

ACM Intermodal Building 3H

~11.38 Tons GFLU002079 Solid Soil/ Garbage/ Debris/

ACM Intermodal Building 6H

~12.74 Tons GFLU-001032 Solid Soil/ Garbage/ Debris/

ACM Intermodal Building 3H

~11.26 Tons EERU-000310 Solid Soil/ Garbage/ Debris/

ACM Intermodal Building 3H

~12.09 Tons GFLU-001742 Solid Soil/ Garbage/ Debris/

ACM Intermodal Building 3H

~9.79 Tons GFLU-002123 Solid Soil/ Garbage/ Debris/

ACM Intermodal Building 3H

~10.93 Tons Totals

~80.53 Tons ATTACH SEPARATE PAGES AS NEEDED. SEPARATE PAGES INCLUDED?

YES NO

12. SAMPLE COLLECTION & ANALYSIS Sample ID/Spectrum ID Media (Soil Water, Other)

Sampler Initials On-Site or Off-Site Lab Analyses / Type Count time (min)

Does not include setup Photo File #

ATTACH SEPARATE PAGES AS NEEDED. SEPARATE PAGES INCLUDED?

YES NO

13. CHANGES/DELAYS/CONFLICTS ANY CHANGES IN SITE CONDITIONS OCCUR TODAY?

Yes No IF YES, EXPLAIN:

DID A DELAY OR WORK STOPPAGE OCCUR TODAY?

Yes No IF YES, EXPLAIN:

HAS ANYTHING DEVELOPED IN THE WORK WHICH MAY LEAD TO A CHANGE?

Yes No IF YES, EXPLAIN:

14. VERBAL INSTRUCTIONS RECEIVED:
15. HEALTH & SAFETY

SUMMARY

SAFETY BRIEFINGS WAS A SAFETY MEETING HELD?

YES NO TOPIC DISCUSSED: Slips-trips-falls, slippery conditions SAFETY INSPECTIONS WAS A SAFETY INSPECTION CONDUCTED?

YES NO DEFICIENCIES NOTED:

YES NO DESCRIBE:

CORRECTIVE ACTIONS TAKEN:

YES NO DESCRIBE:

SUMMARY

OF WORK PERFORMED TYPE OF WORK:

Refer to description provided in Section 3 CHEMICALS USED:

None PPE LEVEL:

Safety shoes, hard hats, and eye protection, safety vest INCIDENT & NEAR MISS/OBSERVATION REPORTING ANY INCIDENTS ON-SITE TODAY?

YES NO DESCRIPTION:

CABRERA INCIDENT REPORTING FORM ATTACHED:

YES NO CLIENT SPECIFIC INCIDENT REPORTING FORM ATTACHED:

YES NO ANY NEAR MISSES/OBSERVATIONS ON-SITE TODAY?

YES NO DESCRIPTION:

H&S RECOMMENDATIONS

16. REMARKS
17. VERIFICATION STATEMENT This report is complete and correct and all materials and equipment used and work performed during this reporting period are in compliance with the contract plans and specifications except as noted above.

NAME/TITLE: Mike Plonski SIGNATURE:

DATE: 08/18/17 Mike Plonski Digitally signed by Mike Plonski DN: cn=Mike Plonski, o=Cabrera Services, ou, email=mplonski@cabreraservices.co m, c=US Date: 2017.08.17 18:20:39 -04'00'

18. PROJECT MANAGER REVIEW & ACCEPTANCE REMARKS AND/OR EXCEPTIONS TO REPORT:

ACCEPTANCE NAME/TITLE: Greg Bright, Deputy Project Manager SIGNATURE:

DATE: 08/18/17 for Greg Bright Digitally signed by Robert E. Flowers DN: cn=Robert E. Flowers, o=Cabrera Services Inc., ou=Corporate, email=rflowers@cabreraservices.com, c=US Date: 2017.08.17 18:52:27 -04'00'

OP 555 - Safety ft1 ceeRERA seRvrces

!./].:---......

' ReotoroclcaL ENGTEEERING

' FFMFDlarloN SIX QUESTIONS FOR SUCCESS - Take two minutes to think through and answer these questions:

1.

What are we about to do?

2.

What equipment are we going to use?

3.

Have l/we been trained to use this equipment?

4.

Have llwe been trained to do this job?

5.

How can llwe be hurt?

6.

How can l/we prevent this incident?

lf you and your tecm aten't prcpared to do tfe asslgned wo*, STOP WORK, and fa,ke time lo prcperly preparc.

This sign-in log documents the topics of the safety meeting and individual attendance. Personnel who perform work operations onsite are required to attend and acknowledge their ability to ask questions and receipt of such briefings daily. Please provide a brief narrative of the selected topics as applicable to the Project in the comment box (ex. Name of AHA reviewed).

PROJECT NAME & LOCATION i.j 'z\\ C - tz1 <.-,t t\\ qw. rrr PROJECT NO.

I C, _ [o1,.1 s :-,

DATE/TIME 2)l,tf rs WEATHER CONDITIONS

  • d > Su.,y.,r l-l *,-,{

Topic Discussion-cher;kone Today's Scope of Work (All tasks)

@les E nta Schedule / New Work / Scope Changes EI yes E n/a Reviewed Procedures, AHA, etc.

E yes E nia Emergency Action Plan & Procedures f] yes E n/a Communications Protocol E yes E nla Required PPE E yes E n/a Required Moniioring / lnstruments E yes E nla Site Control / Work Zones / Security E] yes E n/a Access / Egress / Slips, Trips, & Falls E yes E n/a Smoking, Eating, & Drinking E yes E n/a Washroom / Facilities Location E yes fl n/a HeaUcold Stress E yes I n/a Exclusion Areas Barricades / Cones E yes I n/a Required Permits, Passes, Keys, etc.

E yes I n/a Decon Procedures / IDW Mgmt.

E yes E Va Eqpmt. lnspections/Safety Checklists E yes E n/a OTHER/COMMENTS: -['-r,.5 L,Pt )..tqr( Hrtv,ls Safety MeetinE Attendees Print Name NS C-ir<)

4,

..2 Safety Meeting Leader y1A.[ p( cr.^sr*.

ffi Name of Meeting Leader SEpew,MeEilNG FoRtu Proiect lnformation L1---'

/