OP 359, Field Activity Documentation CABRERA DAILY REPORT
- 1. PROJECT INFORMATION PROJECT NAME/LOCATION: SUPPLEMENTAL RADIOLOGICAL SURVEY Former UNC Manufacturing Facility, New Haven, CT DATE: 03/02/17 REPORT NO. 008 CONTRACT #:
CABRERA PROJECT #: 10-1007.00 TASK #: 016 FIELD SITE MANAGER: Al Craig PROJECT MANAGER: Rob Flowers
- 2. WEATHER TEMPERATURE RANGE: 39-59 degrees F WIND SPEED/DIRECTION: 6-20 mph, gusting to 35 mph, W-NW PRECIPITATION LAST 24 HOURS:
YES NO TYPE: Rain AMOUNT: 0.24 BAROMETRIC PRESSURE: 29.35-30.06 HUMIDITY: 28-83%
HEAT INDEX RANGE: N/A WEATHER DELAYS:
YES NO DELAY TIME (HOURS): N/A
- 3.
SUMMARY
OF WORK Conducted safety meeting prior to beginning field activities.
AIG continued loading ACM waste into intermodal (GFLU001451). Completed loading bulk ACM waste into IMC; final decontamination efforts will generate additional waste to be loaded into the IMC.
Began final ACM decontamination efforts in containment area.
Collected (8) composite waste characterization samples from ACM waste/debris that was loaded into IMC GFLU001451. Samples will be analyzed by on-site gamma spectroscopy.
Cabrera continued to provide radiological support during ACM abatement activities, including air monitoring and general contamination control monitoring.
- 4. MATERIALS & EQUIPMENT BROUGHT ON-SITE Receipt inspection required & completed?
Yes No
- 5. INSPECTIONS TYPE DESCRIPTION ACTION PREPARATORY INITIAL FOLLOW-UP ARE ANY DEFICIENCIES NOTED IN FOLLOW-UP INSPECTIONS?
YES NO - IF YES, EXPLAIN:
- 6. DEFICIENCIES CORRECTED DEFICIENCY #
REPORT REFERENCE DESCRIPTION ACTION
- 7. TESTS PERFORMED SPECIFICATION REFERENCE TYPE TEST & RESULT ARE TEST RESULTS ATTACHED?
YES NO NA - IF NO, EXPLAIN:
- 8. CABRERA PERSONNEL ON-SITE EMPLOYEE NAME TITLE TASK(S) PERFORMED Nicholas Berliner Site Radiation Safety Lead (SRSL)
See Section 3 Summary of Work (8 Hrs)
Alfred Craig Site Safety and Health Officer (SSHO)
See Section 3 Summary of Work (8 Hrs)
Stephan Owe Environmental Scientist See Section 3 Summary of Work (7 Hrs)
- 9. SUBCONTRACTOR PERSONNEL ON-SITE SUBCONTRACTOR NAME JOB DUTY TASK(S) PERFORMED
- OF PERSONNEL MAN-HOURS AIG Asbestos abatement Site Prep 7
56 TOTALS 7
56
- 10. EQUIPMENT & MATERIALS ON-SITE VENDOR EQUIPMENT SERIAL #.
ACTIVE OR IDLE DATE RECEIVED DATE RETURNED ERG 1 Ludlum 2360 scaler/rate meter with 43-93 Zinc sulphide scintillation probe 184909/
PR298426 Active 02/21/2017 ERG 1 Ludlum 2360 scaler/rate meter with 43-93 zinc sulphide scintillation probe 193638/
PR199836 Active 02/21/2017 ERG 1 Ludlum 2360 scaler/rate meter 220242 Active 02/21/2017 ERG 1 Ludlum 2221 scaler/ digital rate meter with FIDLER sodium iodide scintillation probe 190205/
PR01807D Active 02/21/2017 ERG 1 Ludlum 2929 scaler sample counter with 43-10-1 zinc sulphide scintillation probe 200051/
PR215948 Active 02/21/2017 ERG 1 Ludlum model 12 meter with 44-9 Geiger-Mueller probe 276863/
PR147787 Active 02/21/2017 ERG Escort ELF Lapel Air sampler A3-48588 Active 02/21/2017 ERG 1 MircoRem meter 2079 Active 02/21/2017 ERG 1 Low volume air sampler 02/21/2017 ERG 1 Low volume air sampler 02/21/2017 Cabrera 1 Th-230 check source 5648-06 Active 02/21/2017 Cabrera 1 Tc-99 check source 5634-05 Active 02/21/2017 Cabrera 1 Co-60 check source 267D21 Active 02/21/2017 Cabrera 1 Ludlum model 2224-1 scaler/rate meter with 43-93 Zinc sulphide scintillation probe 227246/
PR244549 Active 02/21/2017 Cabrera 1 Ludlum Model 3 rate meter with 44-9 Geiger-Mueller probe 219266/
PR Active 02/21/2017 United Rentals 1 Bobcat T5 90 Skid Steer Active 02/21/2017 United Rentals 1 set of forks, and 1 grapple bucket for Skid Steer Active 02/21/2017 United Rentals 1 Magnum 130 tow behind generator Active 02/21/2017 NEMF Wheel Scale 02/21/2017 Williams Scotsman 1 8 by 20 connex box Active 06/22/2016
- 11. MATERIAL GENERATED/STORED ON-SITE MATERIAL ID SOLID, LIQUID, OR MIXED DESCRIPTION OF MATERIAL CONTAINER TYPE DISPOSITION OR LOCATION OF MATERIAL AMOUNT*
(CY OR TONS)
BFLU000011 Solid Soil/ Garbage/ Debris/
ACM Intermodal Building 6H
~8 Tons GFLU001451 Solid Soil/ Garbage/ Debris/
ACM Intermodal Building 6H
~8 Tons Totals
~16 Tons ATTACH SEPARATE PAGES AS NEEDED. SEPARATE PAGES INCLUDED?
YES NO
- 12. SAMPLE COLLECTION & ANALYSIS Sample ID/Spectrum ID Media (Soil Water, Other)
Sampler Initials On-Site or Off-Site Lab Analyses / Type Count time (sec)
Does not include setup Photo File #
W6H-IMC-1451-S-P-1 Other/Debris NB On-site Gamma Spec TBD NA W6H-IMC-1451-S-P-2 Other/Debris NB On-site Gamma Spec TBD NA W6H-IMC-1451-S-P-3 Other/Debris NB On-site Gamma Spec TBD NA W6H-IMC-1451-S-P-4 Other/Debris NB On-site Gamma Spec TBD NA W6H-IMC-1451-S-P-5 Other/Debris NB On-site Gamma Spec TBD NA W6H-IMC-1451-S-P-6 Other/Debris NB On-site Gamma Spec TBD NA W6H-IMC-1451-S-P-7 Other/Debris NB On-site Gamma Spec TBD NA W6H-IMC-1451-S-P-8 Other/Debris NB On-site Gamma Spec TBD NA ATTACH SEPARATE PAGES AS NEEDED. SEPARATE PAGES INCLUDED?
YES NO
- 13. CHANGES/DELAYS/CONFLICTS ANY CHANGES IN SITE CONDITIONS OCCUR TODAY?
Yes No IF YES, EXPLAIN:
DID A DELAY OR WORK STOPPAGE OCCUR TODAY?
Yes No IF YES, EXPLAIN:
HAS ANYTHING DEVELOPED IN THE WORK WHICH MAY LEAD TO A CHANGE?
Yes No IF YES, EXPLAIN:
- 14. VERBAL INSTRUCTIONS RECEIVED:
- 15. HEALTH & SAFETY
SUMMARY
SAFETY BRIEFINGS WAS A SAFETY MEETING HELD?
YES NO TOPIC DISCUSSED: PPE, machine safety (skid steer, scissor lift), slips-trips-falls, rain/ slippery conditions SAFETY INSPECTIONS WAS A SAFETY INSPECTION CONDUCTED?
YES NO DEFICIENCIES NOTED:
YES NO DESCRIBE:
CORRECTIVE ACTIONS TAKEN:
YES NO DESCRIBE:
SUMMARY
OF WORK PERFORMED TYPE OF WORK:
Refer to description provided in Section 3 CHEMICALS USED:
None PPE LEVEL:
Safety shoes, hard hats, and eye protection, safety vest INCIDENT & NEAR MISS/OBSERVATION REPORTING ANY INCIDENTS ON-SITE TODAY?
YES NO DESCRIPTION:
CABRERA INCIDENT REPORTING FORM ATTACHED:
YES NO CLIENT SPECIFIC INCIDENT REPORTING FORM ATTACHED:
YES NO ANY NEAR MISSES/OBSERVATIONS ON-SITE TODAY?
YES NO DESCRIPTION:
H&S RECOMMENDATIONS
- 16. REMARKS
- 17. VERIFICATION STATEMENT This report is complete and correct and all materials and equipment used and work performed during this reporting period are in compliance with the contract plans and specifications except as noted above.
NAME/TITLE: Nicholas Berliner SIGNATURE:
DATE: 03/3/17
- 18. PROJECT MANAGER REVIEW & ACCEPTANCE REMARKS AND/OR EXCEPTIONS TO REPORT:
ACCEPTANCE NAME/TITLE: Greg Bright, Deputy Project Manager SIGNATURE:
DATE: 03/3/17
OP 555-Safety Meetings
~
CABRERA SERVICES
- =:::: R AOIOLOGtCAL *ENGINEERING
- REMEDIATION SAFETY MEETING FORM SIX QUESTIONS FOR SUCCESS-Take two minutes to think through and answer these questions:
- 1.
What are we about to do?
- 2.
What equipment are we going to use?
- 3.
Have 1/we been trained to use this equipment?
- 4.
Have 1/we been trained to do this job?
- 5.
How can 1/we be hurt?
- 6.
How can 1/we prevent this incident?
If you and your team aren't prepared to do the assigned work, STOP WORK, and take time to properly prepare.
- Project Information This sign-in log documents the topics of the safety meeting and individual attendance. Personnel who perform work operations onsite are required to attend and acknowledge their ability to ask questions and receipt of such briefings daily. Please provide a brief narrative of the selected topics as applicable to the Project in the comment box (ex. Name of AHA reviewed).
PROJECT NAME & LOCATION UNC New Haven 10.1007.00 DATE/TIME WEATHER CONDITIONS 3-2-2017 Topic Discussion-check one Today's Scope of Work (All tasks)
J!1yes 0 n/a Access I Egress I Slips, Trips, & Falls
~yes 0 n/a Schedule I New Work I Scope Changes 0 yes 0 n/a Smoking, Eating, & Drinking 0 yes 0 n/a Reviewed Procedures, AHA, etc.
Dyes 0 n/a Washroom I Facilities Location Dyes 0 n/a Emergency Action Plan & Procedures Dyes D n/a Heat/Cold Stress Dyes 0 n/a Communications Protocol Dyes 0 n/a Exclusion Areas Barricades I Cones Dyes 0 n/a Required PPE Dyes 0 n/a Required Permits, Passes, Keys, etc.
Dyes 0 n/a Required Monitoring /Instruments
~yes 0 n/a Decon Procedures /lOW Mgmt.
Dyes 0 n/a Site Control/ Work Zones I Security 0 yes 0 n/a Eqpmt. Inspections/Safety Checklists Dyes On/a OTHER/COMMENTS Sign RWP for daily access remaining areas at the entrance. Inspect any ladders before use. Inspections of Ariallift and fall protection must be performed daily.
(Q;;g; ;lt :;;i~*
zo~~ agjui_(ct Y
~~~!1~
(f._ I c i/141!. P.
- /~
v(:
AI Craig I SSHO