OP 359, Field Activity Documentation CABRERA DAILY REPORT

1. PROJECT INFORMATION PROJECT NAME/LOCATION: SUPPLEMENTAL RADIOLOGICAL SURVEY Former UNC Manufacturing Facility, New Haven, CT DATE: 06/16/16 REPORT NO. 004 CONTRACT #:

CABRERA PROJECT #: 10-1007.00 TASK #: 015 FIELD SITE MANAGER: Al Craig PROJECT MANAGER: Rob Flowers

2. WEATHER TEMPERATURE RANGE: 63-76 WIND SPEED/DIRECTION: South, calm to 8 mph PRECIPITATION LAST 24 HOURS:

YES NO TYPE: NONE AMOUNT: N/A BAROMETRIC PRESSURE: 29.74-29.85 HUMIDITY: 58-90%

HEAT INDEX RANGE: N/A WEATHER DELAYS:

YES NO DELAY TIME (HOURS): N/A

3.

SUMMARY

OF WORK

1) Begin indoor gamma walkover surveys within western half of Building 3H
4. MATERIALS & EQUIPMENT BROUGHT ON-SITE Receipt inspection required & completed?

Yes No

5. INSPECTIONS TYPE DESCRIPTION ACTION PREPARATORY INITIAL FOLLOW-UP ARE ANY DEFICIENCIES NOTED IN FOLLOW-UP INSPECTIONS?

YES NO - IF YES, EXPLAIN:

6. DEFICIENCIES CORRECTED DEFICIENCY #

REPORT REFERENCE DESCRIPTION ACTION

7. TESTS PERFORMED SPECIFICATION REFERENCE TYPE TEST & RESULT ARE TEST RESULTS ATTACHED?

YES NO NA - IF NO, EXPLAIN:

8. CABRERA PERSONNEL ON-SITE EMPLOYEE NAME TITLE TASK(S) PERFORMED Nicholas Berliner Site Radiation Safety Lead (SRSL)

Sections 3 for tasks (8 Hrs)

Alfred Craig Site Safety and Health Officer (SSHO)

Sections 3 for tasks (8 Hrs)

Michael Plonski Alternate SRSL Sections 3 for tasks (8 Hrs)

9. SUBCONTRACTOR PERSONNEL ON-SITE SUBCONTRACTOR NAME JOB DUTY TASK(S) PERFORMED
  1. OF PERSONNEL MAN-HOURS TOTALS 0

0

10. EQUIPMENT & MATERIALS ON-SITE VENDOR EQUIPMENT SERIAL #.

ACTIVE OR IDLE DATE RECEIVED DATE RETURNED ERG 1 Ludlum 2360 scaler/rate meter with 43-37 gas proportional probe and 239-1F floor monitor cart 145481 PR178371 Active 6/13/16 ERG 1 Ludlum 2360 scaler/rate meter with 43-93 zinc sulphide scintillation probe 184913 PR199839 Active 6/13/16 ERG 1 Ludlum 2929 scaler sample counter with 43-10-1 zinc sulphide scintillation probe 157320 PR157821 Active 6/13/16 ERG 1 Ludlum 2221 scaler/ digital rate meter with Bicron G-5 sodium iodide scintillation probe 108859 010807B Active 6/13/16 Cabrera 1 Th-230 check source 5205-04 Active 6/13/16 Cabrera 1 Tc-99 check source 5649-06 Active 6/13/16 Cabrera 1 Co-60 check source 277D161 Active 6/13/16 Cabrera 1 Cl-36 large-area calibration source AC-2449 Active 6/13/16 Cabrera 1 Sr-90 large-area calibration source AC-2450 Active 6/13/16 Cabrera 1 Tc-99 large-area calibration source AC-2448 Active 6/13/16 Cabrera 1 Th-230 large-area calibration source AC-2446 Active 6/13/16 ERG 1 Escort ELF lapel air sampler A2-32568 Idle 6/13/16 United Rentals 1 Honda EB 6500 generator EBLC-1020473 Idle 6/13/16 United Rentals 1 set of six foot by 30 inch rolling scaffold Idle 6/13/16 United Rentals 1 Skyjack SJIII 4626 electric scissor lift 10149481 Idle 6/14/16 Cabrera 1 Ludlum 2360 scaler/rate meter with 43-93 zinc sulphide scintillation probe 227246 PR244549 Active 6/15/16 Cabrera 1 Ludlum Model 3 rate meter with 44-9 Geiger-Mueller probe 218266 PR299268 Active 6/15/16 Cabrera 1 Bicron MicroRem meter 1844 Active 6/15/16

11. MATERIAL GENERATED/STORED ON-SITE MATERIAL ID SOLID, LIQUID, OR MIXED DESCRIPTION OF MATERIAL CONTAINER TYPE DISPOSITION OR LOCATION OF MATERIAL AMOUNT*

(CY OR TONS)

Totals ATTACH SEPARATE PAGES AS NEEDED. SEPARATE PAGES INCLUDED?

YES NO

12. SAMPLE COLLECTION & ANALYSIS Sample ID/Spectrum ID Media (Soil Water, Other)

Sampler Initials On-Site or Off-Site Lab Analyses / Type Count time (sec)

Does not include setup Photo File #

ATTACH SEPARATE PAGES AS NEEDED. SEPARATE PAGES INCLUDED?

YES NO

13. CHANGES/DELAYS/CONFLICTS ANY CHANGES IN SITE CONDITIONS OCCUR TODAY?

Yes No IF YES, EXPLAIN:

Refer to explanation below in HAS ANYTHING DEVELOPED IN THE WORK WHICH MAY LEAD TO A CHANGE? section.

DID A DELAY OR WORK STOPPAGE OCCUR TODAY?

Yes No IF YES, EXPLAIN:

HAS ANYTHING DEVELOPED IN THE WORK WHICH MAY LEAD TO A CHANGE?

Yes No IF YES, EXPLAIN:

A couple of radioactive metallic items of interest were located in the western half of Building 3H (refer to attached figure).

The discovery of these items indicate that debris from within the building cannot simply be removed from Building 3H/6H and disposed as trash. Cabrera will bring gamma spec equipment to the site tomorrow to characterize these items and determine if there a connection to historic operations at UNC.

14. VERBAL INSTRUCTIONS RECEIVED:
15. HEALTH & SAFETY

SUMMARY

SAFETY BRIEFINGS WAS A SAFETY MEETING HELD?

YES NO TOPIC DISCUSSED: Safe completion of tasks described in Section 3 SAFETY INSPECTIONS WAS A SAFETY INSPECTION CONDUCTED?

YES NO DEFICIENCIES NOTED:

YES NO DESCRIBE:

CORRECTIVE ACTIONS TAKEN:

YES NO DESCRIBE:

SUMMARY

OF WORK PERFORMED TYPE OF WORK:

Refer to description provided in Section 3 CHEMICALS USED:

None PPE LEVEL:

Safety shoes, hard hats, and eye protection INCIDENT & NEAR MISS/OBSERVATION REPORTING ANY INCIDENTS ON-SITE TODAY?

YES NO DESCRIPTION:

CABRERA INCIDENT REPORTING FORM ATTACHED:

YES NO CLIENT SPECIFIC INCIDENT REPORTING FORM ATTACHED:

YES NO ANY NEAR MISSES/OBSERVATIONS ON-SITE TODAY?

YES NO DESCRIPTION:

H&S RECOMMENDATIONS

16. REMARKS John Uruskyj of UNC was on-site; discussions were held between Cabrera, UNC, DOE, and NRC personal regarding these radioactive metallic items of interest and their potential impact on how debris within Building 3H/6H is managed going forward.
17. VERIFICATION STATEMENT This report is complete and correct and all materials and equipment used and work performed during this reporting period are in compliance with the contract plans and specifications except as noted above.

NAME/TITLE: Nicholas Berliner, SRSL SIGNATURE:

DATE: 06/16/16

18. PROJECT MANAGER REVIEW & ACCEPTANCE REMARKS AND/OR EXCEPTIONS TO REPORT:

ACCEPTANCE NAME/TITLE: Rob Flowers, Project Manager SIGNATURE:

DATE: 06/14/16 Digitally signed by Gregory Bright DN: cn=Gregory Bright, o=Cabrera Services Inc., ou, email=gbright@cabreraservices.com, c=US Date: 2016.06.17 16:47:20 -04'00'

OP 555 - Safety Meetings

~

CABRERA SERVICES

=::: RAD IOLOGICAL* ENGINEERING* REMEDIATION SAFETY MEETING FORM SIX QUESTIONS FOR SUCCESS - Take two minutes to think through and answer these questions:
1.

What are we about to do?

2.

What equipment are we going to use?

3.

Have I/we been trained to use this equipment?

4.

Have I/we been trained to do this job?

5.

How can I/we be hurt?

6.

How can I/we prevent this incident?

If you and your team aren't prepared to do the assigned work, STOP WORK, and take time to properly prepare.

Project Information This sign-in log documents the topics of the safety meeting and individual attendance. Personnel who perform work operations onsite are required to attend and acknowledge their ability to ask questions and receipt of such briefings daily. Please provide a brief narrative of the selected topics as applicable to the Project in the comment box (ex. Name of AHA reviewed).

PROJECT NAME & LOCATION UNC New Haven CT 10-1007.00 DATE/TIME WEATHER CONDITIONS 6-16 -2016 Topic Discussion - check one Today's Scope of Work (All tasks)

Dyes D n/a Access I Egress I Slips, Trips, & Falls Dyes D n/a Schedule I New Work I Scope Changes Dyes D n/a Smoking, Eating, & Drinking Dyes D n/a Reviewed Procedures, AHA, etc.

Dyes D n/a Washroom I Facilities Location Dyes D n/a Emergency Action Plan & Procedures Dyes D n/a HeaUCold Stress Dyes D n/a Communications Protocol Dyes D n/a Exclusion Areas Barricades I Cones Dyes D n/a Required PPE Dyes D n/a Required Permits, Passes, Keys, etc.

Dyes D n/a Required Monitoring / Instruments Dyes D n/a Decon Procedures / IDW Mgmt.

Dyes D n/a Site Control /Work Zones I Security Dyes D n1a Eqpmt. Inspections/Safety Checklists Dyes 0 n/a OTHER/COMMENTS Building access Surveys Safety Meeting Attendees Print Name

~

VV\\1~ o\\,e \\.?'CM~~

1*

~1clt- @w~~V\\w

~

/_

I

)

Safety Meeting Leade /}

/

Al Craig I SSHO

~ /

~ '--

\\

Print Name I

Sianature

FORMER UNC FACILITY NEW HAVEN, CONNECTICUT 2/2016 Note: Rooms labeled 'Unknown' were not accessible to assess during a site visit performed on March 1, 2016.

SHELTON AVENUE ARGYLE STREET Decontamination Pit Intact Ductwork Intact Ductwork 50H 41H 19H 11H 10H 9H 8H 7H 14H 44H 6H 6H (Fabrication Shop) 3H FIGURE 2 p

Cabrera Services Baltimore, MD Intact Ductwork Buildings Existing Building Demolished Accessible Area Percent 0 to 25%

>25 to 50%

>50 to 75%

>75 to 100%

Unknown 0

80 160 40 Feet SMO PROJECT NO.

10-1007.00 SITE BUILDINGS BUILDING 3H/6H ACCESSIBLE AREA LOCATION WHERE RADIOACTIVE METALLIC ITEMS OF INTEREST WERE DISCOVERED