ML19095B202
| ML19095B202 | |
| Person / Time | |
|---|---|
| Site: | 07000371 |
| Issue date: | 03/01/2018 |
| From: | Cabrera Services |
| To: | NRC Region 1 |
| Shared Package | |
| ml051740240 | List:
|
| References | |
| Download: ML19095B202 (10) | |
Text
- G A M M A S P E C T R U M A N A L Y S I S *****
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2165\\W3H-IMC-216 Report Generated On : 7/6/2017 9:36:08 AM Sample Title : W3H-IMC-2165-S-P-2 Sample Description :
Sample Identification : IMC-2165-S-P-2 Sample Type :
Sample Geometry : cylinder Peak Locate Threshold : 3.00 Peak Locate Range (in channels) : 40 - 8192 Peak Area Range (in channels) : 40 - 8192 Identification Energy Tolerance : 1.000 keV Sample Size : 2.737E+002 grams Sample Taken On : 5/1/2017 12:00:00 AM Acquisition Started : 5/12/2017 9:25:02 AM Live Time : 1800.0 seconds Real Time : 1800.5 seconds Dead Time : 0.03 %
Energy Calibration Used Done On : 4/13/2017 Efficiency Calibration Used Done On : 7/6/2017 Efficiency ID : H-IMC-2002-S-P-5
Peak Analysis Report 7/6/2017 9:36:08 AM Page 1
- P E A K A N A L Y S I S R E P O R T *****
Detector Name: 8566 Sample
Title:
W3H-IMC-2165-S-P-2 Peak Analysis Performed on: 7/6/2017 9:36:04 AM Peak Analysis From Channel: 40 Peak Analysis To Channel: 8192 Peak ROI ROI Peak Energy FWHM Net Peak Net Area Continuum No. start end centroid (keV) (keV) Area Uncert. Counts F 1 98-108 103.02 25.89 0.76 7.32E+001 72.09 6.33E+001 F 2 207-218 213.10 53.44 0.63 7.17E+001 19.85 1.00E+002 M 3 284-312 290.88 72.90 0.77 1.07E+002 45.74 1.50E+002 m 4 284-312 299.78 75.13 0.78 2.44E+002 89.39 1.85E+002 m 5 284-312 308.06 77.20 0.78 8.74E+001 35.84 1.83E+002 F 6 331-344 337.13 84.47 0.78 2.54E+002 32.09 1.96E+002 F 7 356-365 359.73 90.13 0.74 9.64E+001 22.20 1.17E+002 F 8 365-378 372.83 93.41 0.79 1.29E+002 82.68 1.91E+002 F 9 568-583 574.38 143.85 0.85 3.00E+002 33.86 1.46E+002 F 10 646-659 652.09 163.29 0.84 1.22E+002 22.98 8.05E+001 F 11 736-749 741.84 185.75 0.89 1.45E+003 71.72 8.40E+001 F 12 812-827 820.13 205.34 0.89 1.14E+002 27.19 6.40E+001 M 13 946-970 952.77 238.54 0.90 1.01E+002 21.66 5.00E+001 m 14 946-970 966.70 242.02 0.90 2.02E+001 12.34 3.41E+001 F 15 1401-1412 1405.43 351.81 0.87 4.71E+001 16.18 2.88E+001 F 16 5823-5849 5835.95 1460.53 2.64 1.68E+002 26.12 4.50E+000 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 9:36:08 AM Page 2
- N U C L I D E I D E N T I F I C A T I O N R E P O R T *****
Sample
Title:
W3H-IMC-2165-S-P-2 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201
.................... IDENTIFIED NUCLIDES....................
Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty K-40 0.986 1460.82* 10.66 1.01209E+001 1.74051E+000 Pb-212 0.909 74.82* 10.28 1.94543E+000 7.60413E-001 77.11* 17.10 4.11083E-001 1.77284E-001 86.83 2.07 87.35 3.97 89.78* 1.46 4.89859E+000 1.27918E+000 115.18 0.60 238.63* 43.60 2.59213E-001 6.15902E-002 300.09 3.30 PB-214 0.604 74.82* 5.80 3.44811E+000 1.38263E+000 77.11* 9.70 7.24694E-001 3.19270E-001 86.83 1.70 87.35 2.24 89.78* 0.82 8.72188E+000 2.39986E+000 241.99* 7.25 3.16916E-001 1.96040E-001 258.76 0.53 295.22 18.42 351.93* 35.60 2.19584E-001 7.76692E-002 785.96 1.06 839.07 0.58 Ra-226 0.885 81.07 0.20 83.79* 0.32 5.99003E+001 1.07647E+001 186.21* 3.64 3.60777E+001 4.22066E+000 U-234 0.993 53.20* 0.12 7.31663E+001 2.32759E+001 120.90 0.04 U-235 0.999 89.96* 3.43 2.08509E+000 5.48554E-001 93.35* 5.54 1.71195E+000 1.11519E+000 104.82 0.69 105.60 1.31 108.58 0.50 109.19 1.66 143.76* 10.96 2.11831E+000 3.27067E-001 163.36* 5.08 1.98883E+000 4.30737E-001 194.94 0.63 202.12 1.08 205.32* 5.02 2.22386E+000 5.81474E-001
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance : 1.000 keV Nuclide confidence index threshold = 0.10 Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 9:36:08 AM Page 3
- I N T E R F E R E N C E C O R R E C T E D R E P O R T *****
Nuclide Wt mean Wt mean Nuclide Id Activity Activity Name Confidence (pCi/gram) Uncertainty K-40 0.986 1.012088E+001 1.740511E+000 Pb-212 0.909 2.692442E-001 5.787192E-002 PB-214 0.604 2.406419E-001 7.042612E-002 Ra-226 0.885 3.925194E+001 3.929423E+000 U-234 0.993 7.316632E+001 2.327590E+001 U-235 0.999 2.054203E+000 2.118166E-001
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 9:36:08 AM Page 4
- U N I D E N T I F I E D P E A K S **********
Peak Locate Performed on: 7/6/2017 9:36:04 AM Peak Locate From Channel: 40 Peak Locate To Channel: 8192 Peak Energy Peak Size in Peak CPS Peak Tol.
No. (keV) Counts per Second % Uncertainty Type Nuclide F 1 25.89 4.0647E-002 98.53 M 3 72.90 5.9559E-002 42.67 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma
Nuclide MDA Report 7/6/2017 9:36:08 AM Page 5
- N U C L I D E M D A R E P O R T *****
Detector Name: 8566 Sample Geometry: cylinder Sample
Title:
W3H-IMC-2165-S-P-2 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ K-40 1460.82* 10.66 8.292E-001 8.29E-001 1.012E+001 3.330E-00 Pb-210 46.54 4.25 2.470E+000 2.47E+000 3.732E+000 1.183E+00 BI-212 727.33 6.67 2.129E+000 2.13E+000 3.914E-001 9.937E-00 785.37 1.10 1.355E+001 -1.769E+000 6.316E+00 1078.62 0.56 2.588E+001 -1.171E+001 1.175E+00 1620.50 1.47 9.030E+000 -7.867E+000 3.866E+00
+ Pb-212 74.82* 10.28 5.274E-001 9.17E-002 1.945E+000 2.529E-00 77.11* 17.10 3.086E-001 4.111E-001 1.479E-00 86.83 2.07 3.552E+000 -1.515E-001 1.727E+00 87.35 3.97 1.557E+000 -7.878E-002 7.529E-00 89.78* 1.46 3.085E+000 4.899E+000 1.474E+00 115.18 0.60 8.197E+000 7.487E-001 3.934E+00 238.63* 43.60 9.167E-002 2.592E-001 4.235E-00 300.09 3.30 2.119E+000 -3.858E+000 1.002E+00 BI-214 76.86 0.55 1.646E+001 2.92E-001 -7.404E-002 8.027E+00 79.29 0.91 7.621E+000 -1.699E+000 3.692E+00 609.32 45.49 2.924E-001 3.385E-002 1.375E-00 665.45 1.53 8.809E+000 6.622E+000 4.122E+00 768.36 4.89 3.033E+000 1.123E+000 1.415E+00 806.18 1.26 1.128E+001 -9.958E-001 5.229E+00 934.06 3.11 5.150E+000 -7.655E-001 2.384E+00 1120.29 14.92 1.299E+000 2.554E-001 6.031E-00 1155.21 1.63 1.136E+001 3.503E+000 5.245E+00 1238.11 5.83 3.343E+000 1.202E+000 1.542E+00 1280.98 1.43 1.130E+001 7.813E+000 5.105E+00 1377.67 3.99 4.451E+000 -2.300E-001 2.018E+00 1385.31 0.79 2.048E+001 5.726E+000 9.192E+00 1401.52 1.33 1.121E+001 6.326E+000 4.975E+00 1407.99 2.39 6.385E+000 2.820E+000 2.840E+00 1509.21 2.13 7.468E+000 -1.813E+000 3.313E+00 1583.20 0.70 2.252E+001 -4.572E+000 9.934E+00 1661.27 1.05 1.620E+001 -1.309E+000 7.167E+00 1729.59 2.88 4.895E+000 -6.761E-001 2.096E+00 1764.49 15.30 1.340E+000 9.817E-001 6.024E-00 1847.43 2.03 8.150E+000 2.871E+000 3.543E+00
> 2118.51 1.16 0.000E+000 0.000E+000 0.000E+00
> 2204.06 4.92 0.000E+000 0.000E+000 0.000E+00
> 2447.70 1.55 0.000E+000 0.000E+000 0.000E+00
+ PB-214 74.82* 5.80 9.348E-001 1.35E-001 3.448E+000 4.483E-00 77.11* 9.70 5.440E-001 7.247E-001 2.608E-00 86.83 1.70 4.325E+000 -1.844E-001 2.103E+00 87.35 2.24 2.759E+000 -1.396E-001 1.334E+00
Nuclide MDA Report 7/6/2017 9:36:08 AM Page 6 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ PB-214 89.78* 0.82 5.493E+000 1.35E-001 8.722E+000 2.624E+00 241.99* 7.25 4.685E-001 3.169E-001 2.130E-00 258.76 0.53 1.156E+001 -3.404E+000 5.472E+00 295.22 18.42 4.048E-001 -1.818E-001 1.922E-00 351.93* 35.60 1.347E-001 2.196E-001 6.105E-00 785.96 1.06 1.450E+001 4.716E+000 6.773E+00 839.07 0.58 2.449E+001 2.483E+000 1.132E+00
+ Ra-226 81.07 0.20 3.301E+001 1.31E+000 3.731E+001 1.597E+00 83.79* 0.32 2.048E+001 5.990E+001 9.921E+00 186.21* 3.64 1.314E+000 3.608E+001 6.232E-00 AC-228 89.96 1.90 8.845E+013 1.81E+013 9.352E+013 4.291E+01 93.35 3.10 5.660E+013 -5.058E+013 2.750E+01 99.51 1.26 9.923E+013 -7.569E+013 4.768E+01 105.60 0.74 1.813E+014 -2.423E+014 8.738E+01 129.07 2.42 5.272E+013 8.671E+012 2.533E+01 153.98 0.72 1.808E+014 -1.273E+014 8.664E+01 209.25 3.89 3.962E+013 1.659E+013 1.895E+01 214.85 0.76 1.489E+014 -6.848E+013 6.994E+01 270.24 3.46 4.030E+013 -3.365E+012 1.892E+01 328.00 2.95 6.398E+013 2.599E+012 3.023E+01 338.32 11.27 1.833E+013 1.511E+013 8.689E+01 409.46 1.92 1.200E+014 8.321E+012 5.657E+01 463.00 4.40 4.888E+013 -3.912E+013 2.275E+01 562.50 0.87 3.448E+014 1.334E+014 1.619E+01 674.75 2.10 1.314E+014 -8.108E+013 6.051E+01 726.86 0.62 5.648E+014 1.883E+014 2.635E+01 755.32 1.00 3.335E+014 -6.210E+013 1.546E+01 772.29 1.49 2.434E+014 5.133E+013 1.134E+01 794.95 4.25 8.830E+013 2.069E+013 4.116E+01 830.49 0.54 6.742E+014 -5.953E+013 3.126E+01 835.71 1.61 2.331E+014 4.278E+013 1.083E+01 840.38 0.91 3.975E+014 1.009E+014 1.841E+01 904.20 0.77 5.437E+014 -4.830E+014 2.533E+01 911.20 25.80 1.805E+013 2.082E+013 8.469E+01 964.77 4.99 8.686E+013 -4.119E+013 4.040E+01 968.97 15.80 2.919E+013 2.301E+013 1.363E+01 1247.08 0.50 9.172E+014 4.030E+014 4.208E+01 1459.14 0.83 1.280E+015 3.189E+015 6.140E+01 1495.91 0.86 4.464E+014 9.703E+013 1.975E+01 1588.20 3.22 1.338E+014 1.019E+014 5.964E+01 1630.63 1.51 2.033E+014 -7.587E+012 8.587E+01 TH-230 67.67 0.38 1.693E+001 1.69E+001 -1.165E+001 8.145E+00 PA-234 742.81 0.11 1.208E+002 2.00E+001 1.546E+001 5.587E+00 766.42 0.32 4.605E+001 1.499E+001 2.146E+00 1001.03 0.84 2.002E+001 3.140E+000 9.261E+00 TH-234 63.29 3.70 1.814E+000 1.81E+000 3.163E-001 8.714E-00 92.38 2.13 3.644E+000 8.636E+000 1.775E+00 92.80 2.10 3.564E+000 3.027E+000 1.734E+00 112.81 0.21 2.427E+001 -1.902E+001 1.167E+00
+ U-234 53.20* 0.12 6.091E+001 6.09E+001 7.317E+001 2.908E+00 120.90 0.04 1.482E+002 -3.518E+001 7.127E+00
Nuclide MDA Report 7/6/2017 9:36:08 AM Page 7 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ U-235 89.96* 3.43 1.313E+000 5.06E-001 2.085E+000 6.274E-00 93.35* 5.54 1.136E+000 1.712E+000 5.500E-00 104.82 0.69 7.960E+000 6.118E+000 3.838E+00 105.60 1.31 4.120E+000 -5.508E+000 1.986E+00 108.58 0.50 1.178E+001 -3.097E+000 5.697E+00 109.19 1.66 3.478E+000 -1.230E-001 1.680E+00 143.76* 10.96 5.057E-001 2.118E+000 2.433E-00 163.36* 5.08 8.442E-001 1.989E+000 4.000E-00 194.94 0.63 8.427E+000 5.251E+000 4.011E+00 202.12 1.08 6.538E+000 1.527E+000 3.148E+00 205.32* 5.02 9.454E-001 2.224E+000 4.462E-00
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
7/6/2017 9:36:08 LACE Lace v3.2.1 Page 1
- L I N E A C T I V I T Y C O N S I S T E N C Y E V A L U A T O R ***
===================================================
Analysis using Key Line Activities
===================================================
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2165\\W3H-IMC-216 Equation used to calculate plot: ln(Ratio) = A + B*ln(Energy) where: Ratio = Activity/KL Activity Notes:
'^' Denotes Key Line energy
- All uncertainties quoted at 1.96 sigma Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]
K-40 1460.8 ^ 1.01E+001 17.197 Pb-212 74.8 1.95E+000 39.087 7.505[45.742] 9.73 -1.753 77.1 4.11E-001 43.126 1.586[49.238] [ 0.385]
89.8 4.90E+000 26.113 18.898[35.305]
238.6 ^ 2.59E-001 23.760 1.000[33.602]
PB-214 74.8 3.45E+000 40.098 15.703[53.469] 10.61 -1.806 77.1 7.25E-001 44.056 3.300[56.498] [ 0.369]
89.8 8.72E+000 27.515 39.720[44.813]
242.0 3.17E-001 61.859 1.443[71.257]
351.9 ^ 2.20E-001 35.371 1.000[50.022]
Ra-226 83.8 5.99E+001 17.971 1.660[21.443] 3.32 -0.635 186.2 ^ 3.61E+001 11.699 1.000[16.545] [ 0.339]
U-234 53.2 ^ 7.32E+001 31.812 U-235 90.0 2.09E+000 26.308 0.984[30.505] -0.42 0.081 93.3 1.71E+000 65.141 0.808[66.946] [ 0.478]
143.8 ^ 2.12E+000 15.440 1.000[21.835]
163.4 1.99E+000 21.658 0.939[26.598]
205.3 2.22E+000 26.147 1.050[30.365]