- G A M M A S P E C T R U M A N A L Y S I S *****
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-0310\\W3H-ERRU-03 Report Generated On : 7/6/2017 10:01:01 AM Sample Title : W3H-ERRU-0310-S-P-4 Sample Description :
Sample Identification : 0310-S-P-4 Sample Type :
Sample Geometry : cylinder Peak Locate Threshold : 3.00 Peak Locate Range (in channels) : 40 - 8192 Peak Area Range (in channels) : 40 - 8192 Identification Energy Tolerance : 1.000 keV Sample Size : 3.545E+002 grams Sample Taken On : 6/1/2017 2:00:00 PM Acquisition Started : 6/7/2017 8:44:48 AM Live Time : 1800.0 seconds Real Time : 1800.4 seconds Dead Time : 0.02 %
Energy Calibration Used Done On : 4/13/2017 Efficiency Calibration Used Done On : 7/6/2017 Efficiency ID : H-IMC-2002-S-P-5
Peak Analysis Report 7/6/2017 10:01:01 AM Page 1
- P E A K A N A L Y S I S R E P O R T *****
Detector Name: 8566 Sample
Title:
W3H-ERRU-0310-S-P-4 Peak Analysis Performed on: 7/6/2017 10:00:57 AM Peak Analysis From Channel: 40 Peak Analysis To Channel: 8192 Peak ROI ROI Peak Energy FWHM Net Peak Net Area Continuum No. start end centroid (keV) (keV) Area Uncert. Counts M 1 295-318 299.49 75.06 0.66 1.41E+002 26.52 1.41E+002 m 2 295-318 308.33 77.27 0.67 1.05E+002 22.53 1.46E+002 F 3 366-377 372.16 93.24 0.89 1.11E+002 80.11 6.80E+001 F 4 571-579 574.52 143.88 0.80 6.71E+001 19.19 6.41E+001 F 5 736-748 741.65 185.70 0.86 3.70E+002 37.90 6.01E+001 F 6 947-959 952.87 238.56 0.89 1.76E+002 27.47 6.01E+001 F 7 1174-1185 1179.04 295.16 1.21 5.54E+001 17.12 3.48E+001 F 8 1396-1413 1405.10 351.73 0.81 7.07E+001 46.96 4.50E+001 F 9 2424-2440 2432.30 608.78 1.23 5.25E+001 16.67 2.55E+001 F 10 5822-5846 5834.65 1460.20 2.58 2.04E+002 29.05 1.11E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 10:01:01 AM Page 2
- N U C L I D E I D E N T I F I C A T I O N R E P O R T *****
Sample
Title:
W3H-ERRU-0310-S-P-4 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201
.................... IDENTIFIED NUCLIDES....................
Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty K-40 0.940 1460.82* 10.66 9.49960E+000 1.52062E+000 Pb-212 0.998 74.82* 10.28 8.69239E-001 2.01199E-001 77.11* 17.10 3.81714E-001 9.62808E-002 86.83 2.07 87.35 3.97 89.78 1.46 115.18 0.60 238.63* 43.60 3.50564E-001 6.50684E-002 300.09 3.30 BI-214 0.205 76.86* 0.55 1.19767E+001 3.04004E+000 79.29 0.91 609.32* 45.49 2.61230E-001 8.52173E-002 665.45 1.53 768.36 4.89 806.18 1.26 934.06 3.11 1120.29 14.92 1155.21 1.63 1238.11 5.83 1280.98 1.43 1377.67 3.99 1385.31 0.79 1401.52 1.33 1407.99 2.39 1509.21 2.13 1583.20 0.70 1661.27 1.05 1729.59 2.88 1764.49 15.30 1847.43 2.03 2118.51 1.16 2204.06 4.92 2447.70 1.55 PB-214 0.849 74.82* 5.80 1.54065E+000 3.82324E-001 77.11* 9.70 6.72919E-001 1.80220E-001 86.83 1.70 87.35 2.24 89.78 0.82 241.99 7.25 258.76 0.53 295.22* 18.42 3.21096E-001 1.03387E-001 351.93* 35.60 2.54588E-001 1.70352E-001
Interference Corrected Activity Report 7/6/2017 10:01:01 AM Page 3 Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty PB-214 0.849 785.96 1.06 839.07 0.58 Ra-226 0.965 81.07 0.20 83.79 0.32 186.21* 3.64 7.11180E+000 1.04871E+000 U-235 0.575 89.96 3.43 93.35* 5.54 1.13387E+000 8.31381E-001 104.82 0.69 105.60 1.31 108.58 0.50 109.19 1.66 143.76* 10.96 3.66262E-001 1.11607E-001 163.36 5.08 194.94 0.63 202.12 1.08 205.32 5.02
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance : 1.000 keV Nuclide confidence index threshold = 0.10 Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 10:01:01 AM Page 4
- I N T E R F E R E N C E C O R R E C T E D R E P O R T *****
Nuclide Wt mean Wt mean Nuclide Id Activity Activity Name Confidence (pCi/gram) Uncertainty K-40 0.940 9.499601E+000 1.520616E+000 Pb-212 0.998 3.339356E-001 5.408842E-002 BI-214 0.205 2.580736E-001 8.517683E-002 PB-214 0.849 2.853062E-001 8.004820E-002 Ra-226 0.965 7.111801E+000 1.048713E+000 U-235 0.575 3.798504E-001 1.106150E-001
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.960 sigma
- U N I D E N T I F I E D P E A K S **********
Peak Locate Performed on: 7/6/2017 10:00:56 AM Peak Locate From Channel: 40 Peak Locate To Channel: 8192 Peak Energy Peak Size in Peak CPS Peak Tol.
No. (keV) Counts per Second % Uncertainty Type Nuclide All peaks were identified.
Nuclide MDA Report 7/6/2017 10:01:01 AM Page 5
- N U C L I D E M D A R E P O R T *****
Detector Name: 8566 Sample Geometry: cylinder Sample
Title:
W3H-ERRU-0310-S-P-4 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ K-40 1460.82* 10.66 9.156E-001 9.16E-001 9.500E+000 3.948E-00 Pb-210 46.54 4.25 1.518E+000 1.52E+000 3.300E-001 7.185E-00 BI-212 727.33 6.67 1.887E+000 1.89E+000 1.088E+000 8.892E-00 785.37 1.10 1.061E+001 2.976E+000 4.952E+00 1078.62 0.56 2.025E+001 -1.320E+001 9.209E+00 1620.50 1.47 6.718E+000 -6.445E+000 2.858E+00
+ Pb-212 74.82* 10.28 3.576E-001 8.75E-002 8.692E-001 1.704E-00 77.11* 17.10 2.139E-001 3.817E-001 1.020E-00 86.83 2.07 2.182E+000 -8.794E-001 1.053E+00 87.35 3.97 1.045E+000 -2.905E+000 5.025E-00 89.78 1.46 2.742E+000 -9.818E-002 1.318E+00 115.18 0.60 5.542E+000 4.843E-001 2.644E+00 238.63* 43.60 8.754E-002 3.506E-001 4.108E-00 300.09 3.30 1.822E+000 -1.053E+000 8.664E-00
+ BI-214 76.86* 0.55 6.711E+000 1.42E-001 1.198E+001 3.202E+00 79.29 0.91 5.418E+000 -1.121E-001 2.618E+00 609.32* 45.49 1.419E-001 2.612E-001 6.422E-00 665.45 1.53 7.270E+000 5.263E+000 3.417E+00 768.36 4.89 2.486E+000 1.239E-001 1.165E+00 806.18 1.26 8.097E+000 -6.903E+000 3.732E+00 934.06 3.11 3.976E+000 -1.338E+000 1.841E+00 1120.29 14.92 9.698E-001 1.922E-001 4.490E-00 1155.21 1.63 9.097E+000 2.751E+000 4.212E+00 1238.11 5.83 2.862E+000 6.509E-001 1.331E+00 1280.98 1.43 1.038E+001 8.198E+000 4.774E+00 1377.67 3.99 3.848E+000 2.651E+000 1.764E+00 1385.31 0.79 1.922E+001 3.889E+000 8.803E+00 1401.52 1.33 9.846E+000 3.383E+000 4.436E+00 1407.99 2.39 5.403E+000 -5.583E-001 2.429E+00 1509.21 2.13 4.973E+000 -7.999E-002 2.162E+00 1583.20 0.70 1.999E+001 1.765E+000 8.972E+00 1661.27 1.05 1.070E+001 3.563E+000 4.629E+00 1729.59 2.88 3.641E+000 -7.227E-001 1.549E+00 1764.49 15.30 1.163E+000 9.253E-001 5.295E-00 1847.43 2.03 5.507E+000 -1.336E+000 2.343E+00
> 2118.51 1.16 0.000E+000 0.000E+000 0.000E+00
> 2204.06 4.92 0.000E+000 0.000E+000 0.000E+00
> 2447.70 1.55 0.000E+000 0.000E+000 0.000E+00
+ PB-214 74.82* 5.80 6.338E-001 1.43E-001 1.541E+000 3.021E-00 77.11* 9.70 3.771E-001 6.729E-001 1.799E-00 86.83 1.70 2.656E+000 -1.071E+000 1.282E+00 87.35 2.24 1.851E+000 -5.148E+000 8.907E-00
Nuclide MDA Report 7/6/2017 10:01:01 AM Page 6 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ PB-214 89.78 0.82 4.881E+000 1.43E-001 -1.748E-001 2.346E+00 241.99 7.25 1.038E+000 9.994E-002 5.025E-00 258.76 0.53 8.806E+000 -2.064E+000 4.164E+00 295.22* 18.42 1.826E-001 3.211E-001 8.346E-00 351.93* 35.60 1.427E-001 2.546E-001 6.646E-00 785.96 1.06 1.080E+001 -4.673E+000 5.033E+00 839.07 0.58 1.991E+001 1.082E+001 9.242E+00
+ Ra-226 81.07 0.20 1.873E+001 8.47E-001 -1.361E+001 8.949E+00 83.79 0.32 1.406E+001 9.970E+000 6.782E+00 186.21* 3.64 8.474E-001 7.112E+000 3.977E-00 AC-228 89.96 1.90 1.409E+007 3.76E+006 -4.796E+005 6.783E+00 93.35 3.10 8.779E+006 -4.068E+005 4.232E+00 99.51 1.26 1.453E+007 4.233E+005 6.885E+00 105.60 0.74 3.064E+007 8.048E+006 1.467E+00 129.07 2.42 8.460E+006 3.954E+005 4.026E+00 153.98 0.72 3.129E+007 2.244E+007 1.491E+00 209.25 3.89 7.596E+006 -3.624E+005 3.628E+00 214.85 0.76 3.571E+007 1.592E+007 1.696E+00 270.24 3.46 9.255E+006 2.695E+005 4.384E+00 328.00 2.95 1.323E+007 3.980E+006 6.266E+00 338.32 11.27 3.756E+006 1.180E+006 1.784E+00 409.46 1.92 2.322E+007 5.481E+006 1.094E+00 463.00 4.40 1.077E+007 -8.844E+006 5.050E+00 562.50 0.87 7.008E+007 1.108E+007 3.297E+00 674.75 2.10 2.959E+007 -2.501E+007 1.377E+00 726.86 0.62 1.298E+008 8.680E+007 6.115E+00 755.32 1.00 7.472E+007 1.139E+007 3.496E+00 772.29 1.49 5.219E+007 -1.508E+007 2.445E+00 794.95 4.25 1.512E+007 -3.340E+006 6.970E+00 830.49 0.54 1.214E+008 -3.452E+007 5.587E+00 835.71 1.61 4.494E+007 1.363E+007 2.084E+00 840.38 0.91 7.717E+007 -7.823E+006 3.568E+00 904.20 0.77 1.144E+008 -6.041E+007 5.351E+00 911.20 25.80 3.934E+006 3.340E+006 1.857E+00 964.77 4.99 1.881E+007 1.656E+007 8.805E+00 968.97 15.80 6.076E+006 7.671E+006 2.848E+00 1247.08 0.50 1.731E+008 -2.465E+008 7.910E+00 1459.14 0.83 2.862E+008 8.818E+008 1.379E+00 1495.91 0.86 9.386E+007 3.043E+007 4.186E+00 1588.20 3.22 2.978E+007 1.086E+007 1.346E+00 1630.63 1.51 4.917E+007 1.234E+007 2.146E+00 TH-230 67.67 0.38 1.217E+001 1.22E+001 7.004E+000 5.838E+00 PA-234 742.81 0.11 1.056E+002 1.61E+001 7.182E+001 4.933E+00 766.42 0.32 3.732E+001 -1.463E+001 1.745E+00 1001.03 0.84 1.613E+001 3.037E+000 7.486E+00 TH-234 63.29 3.70 1.332E+000 1.33E+000 -2.917E-001 6.386E-00 92.38 2.13 2.196E+000 4.454E+000 1.062E+00 92.80 2.10 2.138E+000 1.243E+000 1.033E+00 112.81 0.21 1.485E+001 -1.305E+001 7.067E+00 U-234 53.20 0.12 4.649E+001 4.65E+001 1.535E+001 2.217E+00 120.90 0.04 9.136E+001 -2.012E-001 4.350E+00
Nuclide MDA Report 7/6/2017 10:01:01 AM Page 7 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ U-235 89.96 3.43 1.227E+000 2.24E-001 -4.176E-002 5.907E-00 93.35* 5.54 5.082E-001 1.134E+000 2.403E-00 104.82 0.69 5.044E+000 1.719E+000 2.412E+00 105.60 1.31 2.720E+000 7.146E-001 1.303E+00 108.58 0.50 7.088E+000 7.971E-001 3.393E+00 109.19 1.66 2.069E+000 -1.028E+000 9.891E-00 143.76* 10.96 2.243E-001 3.663E-001 1.048E-00 163.36 5.08 7.838E-001 5.979E-001 3.748E-00 194.94 0.63 6.757E+000 -3.881E+000 3.222E+00 202.12 1.08 4.344E+000 1.456E+000 2.078E+00 205.32 5.02 9.219E-001 -2.021E-001 4.405E-00
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
7/6/2017 10:01:01 LACE Lace v3.2.1 Page 1
- L I N E A C T I V I T Y C O N S I S T E N C Y E V A L U A T O R ***
===================================================
Analysis using Key Line Activities
===================================================
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-0310\\W3H-ERRU-03 Equation used to calculate plot: ln(Ratio) = A + B*ln(Energy) where: Ratio = Activity/KL Activity Notes:
'^' Denotes Key Line energy
- All uncertainties quoted at 1.96 sigma Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]
K-40 1460.8 ^ 9.50E+000 16.007 Pb-212 74.8 8.69E-001 23.147 2.480[29.669] 2.53 -0.464 77.1 3.82E-001 25.223 1.089[31.317] [ 0.296]
238.6 ^ 3.51E-001 18.561 1.000[26.249]
BI-214 76.9 1.20E+001 25.383 45.847[41.334] 11.85 -1.848 609.3 ^ 2.61E-001 32.622 1.000[46.134] [ 0.299]
PB-214 74.8 1.54E+000 24.816 6.052[71.366] 5.23 -0.885 77.1 6.73E-001 26.782 2.643[72.073] [ 0.541]
295.2 3.21E-001 32.198 1.261[74.256]
351.9 ^ 2.55E-001 66.913 1.000[94.629]
Ra-226 186.2 ^ 7.11E+000 14.746 U-235 93.3 1.13E+000 73.322 3.096[79.402] 13.00 -2.617 143.8 ^ 3.66E-001 30.472 1.000[43.094] [ 2.092]