- G A M M A S P E C T R U M A N A L Y S I S *****
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2123\\UNC-GFLU-21 Report Generated On : 7/6/2017 10:13:48 AM Sample Title : UNC-GFLU-2123-S-P-7 Sample Description :
Sample Identification : 2123-S-P-7 Sample Type :
Sample Geometry : cylinder Peak Locate Threshold : 3.00 Peak Locate Range (in channels) : 40 - 8192 Peak Area Range (in channels) : 40 - 8192 Identification Energy Tolerance : 1.000 keV Sample Size : 3.410E+002 grams Sample Taken On : 6/1/2017 2:00:00 PM Acquisition Started : 6/5/2017 1:38:43 PM Live Time : 1800.0 seconds Real Time : 1800.4 seconds Dead Time : 0.02 %
Energy Calibration Used Done On : 4/13/2017 Efficiency Calibration Used Done On : 7/6/2017 Efficiency ID : H-IMC-2002-S-P-5
Peak Analysis Report 7/6/2017 10:13:48 AM Page 1
- P E A K A N A L Y S I S R E P O R T *****
Detector Name: 8566 Sample
Title:
UNC-GFLU-2123-S-P-7 Peak Analysis Performed on: 7/6/2017 10:13:44 AM Peak Analysis From Channel: 40 Peak Analysis To Channel: 8192 Peak ROI ROI Peak Energy FWHM Net Peak Net Area Continuum No. start end centroid (keV) (keV) Area Uncert. Counts M 1 295-316 299.60 75.08 0.71 1.10E+002 22.98 1.01E+002 m 2 295-316 308.56 77.33 0.72 4.81E+001 17.25 1.20E+002 F 3 356-364 359.85 90.16 0.70 4.57E+001 15.86 5.40E+001 F 4 570- 580 574.10 143.77 0.76 5.09E+001 88.47 5.78E+001 F 5 734-749 741.73 185.73 1.01 3.15E+002 81.38 6.60E+001 F 6 948-957 952.83 238.55 0.86 7.95E+001 19.81 3.50E+001 F 7 1174-1183 1179.02 295.15 0.45 1.75E+001 36.61 2.80E+001 F 8 1400- 1413 1404.74 351.64 0.52 3.73E+001 14.42 3.92E+001 F 9 2427-2440 2433.36 609.05 1.24 2.84E+001 13.91 2.33E+001 F 10 5824-5849 5835.52 1460.42 2.98 1.59E+002 25.12 2.89E+000 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 10:13:48 AM Page 2
- N U C L I D E I D E N T I F I C A T I O N R E P O R T *****
Sample
Title:
UNC-GFLU-2123-S-P-7 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201
.................... IDENTIFIED NUCLIDES....................
Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty K-40 0.974 1460.82* 10.66 7.68659E+000 1.33980E+000 Pb-212 0.996 74.82* 10.28 7.05703E-001 1.75349E-001 77.11* 17.10 1.81251E-001 6.93898E-002 86.83 2.07 87.35 3.97 89.78* 1.46 1.86307E+000 6.86193E-001 115.18 0.60 238.63* 43.60 1.64366E-001 4.41613E-002 300.09 3.30 BI-214 0.365 76.86* 0.55 5.68695E+000 2.18318E+000 79.29 0.91 609.32* 45.49 1.47075E-001 7.27826E-002 665.45 1.53 768.36 4.89 806.18 1.26 934.06 3.11 1120.29 14.92 1155.21 1.63 1238.11 5.83 1280.98 1.43 1377.67 3.99 1385.31 0.79 1401.52 1.33 1407.99 2.39 1509.21 2.13 1583.20 0.70 1661.27 1.05 1729.59 2.88 1764.49 15.30 1847.43 2.03 2118.51 1.16 2204.06 4.92 2447.70 1.55 PB-214 0.845 74.82* 5.80 1.25080E+000 3.30328E-001 77.11* 9.70 3.19524E-001 1.25663E-001 86.83 1.70 87.35 2.24 89.78* 0.82 3.31718E+000 1.25516E+000 241.99 7.25 258.76 0.53 295.22* 18.42 1.05703E-001 2.20847E-001 351.93* 35.60 1.39523E-001 5.51896E-002
Interference Corrected Activity Report 7/6/2017 10:13:48 AM Page 3 Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty PB-214 0.845 785.96 1.06 839.07 0.58 Ra-226 0.968 81.07 0.20 83.79 0.32 186.21* 3.64 6.29288E+000 1.75938E+000 U-235 0.520 89.96* 3.43 7.93025E-001 2.93180E-001 93.35 5.54 104.82 0.69 105.60 1.31 108.58 0.50 109.19 1.66 143.76* 10.96 2.88768E-001 5.02592E-001 163.36 5.08 194.94 0.63 202.12 1.08 205.32 5.02
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance : 1.000 keV Nuclide confidence index threshold = 0.10 Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 10:13:48 AM Page 4
- I N T E R F E R E N C E C O R R E C T E D R E P O R T *****
Nuclide Wt mean Wt mean Nuclide Id Activity Activity Name Confidence (pCi/gram) Uncertainty K-40 0.974 7.686592E+000 1.339799E+000 Pb-212 0.996 1.670236E-001 3.736861E-002 BI-214 0.365 1.446002E-001 7.274897E-002 PB-214 0.845 1.396234E-001 4.986322E-002 Ra-226 0.968 6.292881E+000 1.759381E+000 U-235 0.520 5.885086E-001 2.517302E-001
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.960 sigma
- U N I D E N T I F I E D P E A K S **********
Peak Locate Performed on: 7/6/2017 10:13:44 AM Peak Locate From Channel: 40 Peak Locate To Channel: 8192 Peak Energy Peak Size in Peak CPS Peak Tol.
No. (keV) Counts per Second % Uncertainty Type Nuclide All peaks were identified.
Nuclide MDA Report 7/6/2017 10:13:48 AM Page 5
- N U C L I D E M D A R E P O R T *****
Detector Name: 8566 Sample Geometry: cylinder Sample
Title:
UNC-GFLU-2123-S-P-7 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ K-40 1460.82* 10.66 5.545E-001 5.54E-001 7.687E+000 2.117E-00 Pb-210 46.54 4.25 1.726E+000 1.73E+000 1.263E+000 8.207E-00 BI-212 727.33 6.67 1.790E+000 1.79E+000 -1.257E-001 8.382E-00 785.37 1.10 9.608E+000 5.408E+000 4.435E+00 1078.62 0.56 2.319E+001 -1.813E+001 1.064E+00 1620.50 1.47 7.980E+000 -5.160E+000 3.469E+00
+ Pb-212 74.82* 10.28 3.169E-001 6.59E-002 7.057E-001 1.498E-00 77.11* 17.10 2.025E-001 1.813E-001 9.616E-00 86.83 2.07 2.097E+000 2.577E-001 1.009E+00 87.35 3.97 9.988E-001 -1.260E+000 4.789E-00 89.78* 1.46 1.669E+000 1.863E+000 7.792E-00 115.18 0.60 5.210E+000 1.137E+000 2.473E+00 238.63* 43.60 6.592E-002 1.644E-001 3.017E-00 300.09 3.30 1.724E+000 -6.570E-001 8.157E-00
+ BI-214 76.86* 0.55 6.354E+000 1.35E-001 5.687E+000 3.017E+00 79.29 0.91 4.602E+000 8.390E-001 2.206E+00 609.32* 45.49 1.350E-001 1.471E-001 6.050E-00 665.45 1.53 6.594E+000 2.634E-001 3.070E+00 768.36 4.89 2.434E+000 2.653E+000 1.136E+00 806.18 1.26 8.251E+000 -1.460E+000 3.796E+00 934.06 3.11 4.479E+000 2.458E+000 2.086E+00 1120.29 14.92 9.904E-001 3.549E-001 4.579E-00 1155.21 1.63 9.620E+000 1.406E+000 4.460E+00 1238.11 5.83 2.881E+000 1.579E+000 1.337E+00 1280.98 1.43 1.080E+001 -7.236E+000 4.963E+00 1377.67 3.99 3.623E+000 1.313E+000 1.645E+00 1385.31 0.79 1.615E+001 -9.917E+000 7.235E+00 1401.52 1.33 1.007E+001 -3.829E+000 4.528E+00 1407.99 2.39 6.234E+000 3.993E+000 2.834E+00 1509.21 2.13 5.461E+000 1.372E+000 2.393E+00 1583.20 0.70 1.765E+001 -1.354E+000 7.761E+00 1661.27 1.05 9.631E+000 -5.252E-001 4.067E+00 1729.59 2.88 4.449E+000 3.339E+000 1.942E+00 1764.49 15.30 1.075E+000 4.959E-001 4.835E-00 1847.43 2.03 8.048E+000 1.499E+000 3.597E+00
> 2118.51 1.16 0.000E+000 0.000E+000 0.000E+00
> 2204.06 4.92 0.000E+000 0.000E+000 0.000E+00
> 2447.70 1.55 0.000E+000 0.000E+000 0.000E+00
+ PB-214 74.82* 5.80 5.618E-001 1.29E-001 1.251E+000 2.655E-00 77.11* 9.70 3.570E-001 3.195E-001 1.695E-00 86.83 1.70 2.554E+000 3.138E-001 1.229E+00 87.35 2.24 1.770E+000 -2.232E+000 8.487E-00
Nuclide MDA Report 7/6/2017 10:13:48 AM Page 6 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ PB-214 89.78* 0.82 2.971E+000 1.29E-001 3.317E+000 1.387E+00 241.99 7.25 8.439E-001 -7.934E-001 4.049E-00 258.76 0.53 8.590E+000 5.867E-001 4.047E+00 295.22* 18.42 1.647E-001 1.057E-001 7.420E-00 351.93* 35.60 1.295E-001 1.395E-001 5.968E-00 785.96 1.06 9.901E+000 4.311E+000 4.567E+00 839.07 0.58 2.323E+001 2.000E+001 1.087E+00
+ Ra-226 81.07 0.20 1.733E+001 9.80E-001 -2.340E+000 8.234E+00 83.79 0.32 1.364E+001 1.835E+001 6.562E+00 186.21* 3.64 9.803E-001 6.293E+000 4.631E-00 AC-228 89.96 1.90 1.081E+005 2.68E+004 -1.278E+005 5.197E+00 93.35 3.10 6.476E+004 6.194E+004 3.111E+00 99.51 1.26 1.153E+005 7.406E+004 5.458E+00 105.60 0.74 2.064E+005 -1.416E+004 9.797E+00 129.07 2.42 6.346E+004 8.059E+003 3.008E+00 153.98 0.72 2.229E+005 -4.240E+004 1.055E+00 209.25 3.89 5.399E+004 -2.850E+004 2.562E+00 214.85 0.76 2.792E+005 3.178E+005 1.324E+00 270.24 3.46 6.393E+004 -2.481E+004 3.000E+00 328.00 2.95 1.049E+005 1.255E+005 4.967E+00 338.32 11.27 2.760E+004 1.289E+004 1.304E+00 409.46 1.92 1.752E+005 5.875E+004 8.214E+00 463.00 4.40 8.750E+004 1.931E+004 4.104E+00 562.50 0.87 4.819E+005 -2.191E+005 2.242E+00 674.75 2.10 2.296E+005 9.616E+004 1.065E+00 726.86 0.62 9.508E+005 -6.675E+004 4.453E+00 755.32 1.00 5.627E+005 1.022E+003 2.620E+00 772.29 1.49 3.677E+005 8.470E+004 1.706E+00 794.95 4.25 1.346E+005 5.041E+004 6.252E+00 830.49 0.54 1.146E+006 -3.903E+005 5.338E+00 835.71 1.61 4.033E+005 1.045E+005 1.884E+00 840.38 0.91 7.171E+005 5.016E+005 3.351E+00 904.20 0.77 8.990E+005 -2.314E+005 4.199E+00 911.20 25.80 2.683E+004 7.893E+003 1.253E+00 964.77 4.99 1.375E+005 9.636E+004 6.392E+00 968.97 15.80 4.461E+004 1.630E+003 2.077E+00 1247.08 0.50 1.495E+006 -1.197E+006 6.873E+00 1459.14 0.83 1.979E+006 4.491E+006 9.479E+00 1495.91 0.86 6.458E+005 3.366E+004 2.819E+00 1588.20 3.22 2.006E+005 1.033E+005 8.875E+00 1630.63 1.51 3.971E+005 9.965E+004 1.733E+00 TH-230 67.67 0.38 9.698E+000 9.70E+000 -6.168E+000 4.591E+00 PA-234 742.81 0.11 1.028E+002 1.70E+001 -7.829E+000 4.777E+00 766.42 0.32 3.669E+001 1.785E+001 1.709E+00 1001.03 0.84 1.703E+001 1.036E+001 7.918E+00 TH-234 63.29 3.70 1.230E+000 1.23E+000 5.923E-001 5.865E-00 92.38 2.13 2.115E+000 1.876E+000 1.020E+00 92.80 2.10 2.075E+000 2.247E+000 9.994E-00 112.81 0.21 1.487E+001 -6.806E+000 7.061E+00 U-234 53.20 0.12 4.065E+001 4.06E+001 7.705E+000 1.921E+00 120.90 0.04 9.363E+001 2.677E+001 4.455E+00
Nuclide MDA Report 7/6/2017 10:13:48 AM Page 7 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ U-235 89.96* 3.43 7.103E-001 2.34E-001 7.930E-001 3.317E-00 93.35 5.54 7.333E-001 7.015E-001 3.523E-00 104.82 0.69 4.404E+000 -8.161E-001 2.088E+00 105.60 1.31 2.359E+000 -1.618E-001 1.120E+00 108.58 0.50 6.352E+000 -3.160E+000 3.019E+00 109.19 1.66 1.928E+000 5.225E-002 9.168E-00 143.76* 10.96 2.338E-001 2.888E-001 1.092E-00 163.36 5.08 7.042E-001 -1.476E-001 3.343E-00 194.94 0.63 6.207E+000 -1.470E+000 2.941E+00 202.12 1.08 3.960E+000 -8.469E-001 1.882E+00 205.32 5.02 9.012E-001 5.165E-001 4.294E-00
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
7/6/2017 10:13:48 LACE Lace v3.2.1 Page 1
- L I N E A C T I V I T Y C O N S I S T E N C Y E V A L U A T O R ***
===================================================
Analysis using Key Line Activities
===================================================
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2123\\UNC-GFLU-21 Equation used to calculate plot: ln(Ratio) = A + B*ln(Energy) where: Ratio = Activity/KL Activity Notes:
'^' Denotes Key Line energy
- All uncertainties quoted at 1.96 sigma Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]
K-40 1460.8 ^ 7.69E+000 17.430 Pb-212 74.8 7.06E-001 24.847 4.293[36.596] 6.11 -1.095 77.1 1.81E-001 38.284 1.103[46.771] [ 0.407]
89.8 1.86E+000 36.831 11.335[45.590]
238.6 ^ 1.64E-001 26.868 1.000[37.997]
BI-214 76.9 5.69E+000 38.389 38.667[62.631] 11.32 -1.765 609.3 ^ 1.47E-001 49.487 1.000[69.985] [ 0.454]
PB-214 74.8 1.25E+000 26.409 8.965[47.562] 7.82 -1.318 77.1 3.20E-001 39.328 2.290[55.780] [ 0.418]
89.8 3.32E+000 37.838 23.775[54.739]
295.2 1.06E-001 208.93 0.758[212.64]
351.9 ^ 1.40E-001 39.556 1.000[55.940]
Ra-226 186.2 ^ 6.29E+000 27.958 U-235 90.0 7.93E-001 36.970 2.746[177.93] 10.71 -2.155 143.8 ^ 2.89E-001 174.04 1.000[246.14] [ 6.478]