ML19095A944
| ML19095A944 | |
| Person / Time | |
|---|---|
| Site: | 07000371 |
| Issue date: | 03/01/2018 |
| From: | Cabrera Services |
| To: | NRC Region 1 |
| Shared Package | |
| ml051740240 | List:
|
| References | |
| Download: ML19095A944 (10) | |
Text
- G A M M A S P E C T R U M A N A L Y S I S *****
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2123\\UNC-GFLU-21 Report Generated On : 7/6/2017 10:10:40 AM Sample Title : UNC-GFLU-2123-S-P-1 Sample Description :
Sample Identification : UNC-GFLU-2123-S-Sample Type :
Sample Geometry : cylinder Peak Locate Threshold : 3.00 Peak Locate Range (in channels) : 40 - 8192 Peak Area Range (in channels) : 40 - 8192 Identification Energy Tolerance : 1.000 keV Sample Size : 3.602E+002 grams Sample Taken On : 6/1/2017 2:00:00 PM Acquisition Started : 6/5/2017 8:59:25 AM Live Time : 1800.0 seconds Real Time : 1800.6 seconds Dead Time : 0.03 %
Energy Calibration Used Done On : 4/13/2017 Efficiency Calibration Used Done On : 7/6/2017 Efficiency ID : H-IMC-2002-S-P-5
Peak Analysis Report 7/6/2017 10:10:40 AM Page 1
- P E A K A N A L Y S I S R E P O R T *****
Detector Name: 8566 Sample
Title:
UNC-GFLU-2123-S-P-1 Peak Analysis Performed on: 7/6/2017 10:10:36 AM Peak Analysis From Channel: 40 Peak Analysis To Channel: 8192 Peak ROI ROI Peak Energy FWHM Net Peak Net Area Continuum No. start end centroid (keV) (keV) Area Uncert. Counts M 1 294-313 299.81 75.14 0.65 9.45E+001 23.48 1.46E+002 m 2 294-313 308.82 77.39 0.66 6.03E+001 18.92 1.19E+002 F 3 571-580 574.70 143.93 0.73 8.12E+001 19.11 4.88E+001 F 4 733-750 741.90 185.77 0.99 3.77E+002 88.89 5.63E+001 M 5 947-971 952.84 238.55 1.01 8.11E+001 19.25 3.60E+001 m 6 947-971 966.20 241.90 1.02 2.60E+001 13.31 4.20E+001 F 7 1398-1413 1405.56 351.84 1.20 7.38E+001 42.48 3.68E+001 F 8 2426-2441 2433.35 609.04 1.16 4.24E+001 15.10 2.27E+001 F 9 5824-5849 5836.17 1460.58 2.58 1.58E+002 25.33 4.33E+000 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 10:10:40 AM Page 2
- N U C L I D E I D E N T I F I C A T I O N R E P O R T *****
Sample
Title:
UNC-GFLU-2123-S-P-1 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201
.................... IDENTIFIED NUCLIDES....................
Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty K-40 0.991 1460.82* 10.66 7.22987E+000 1.27562E+000 Pb-212 0.995 74.82* 10.28 5.73500E-001 1.62038E-001 77.11* 17.10 2.15301E-001 7.33447E-002 86.83 2.07 87.35 3.97 89.78 1.46 115.18 0.60 238.63* 43.60 1.58629E-001 4.09247E-002 300.09 3.30 BI-214 0.296 76.86* 0.55 6.75532E+000 2.30927E+000 79.29 0.91 609.32* 45.49 2.07516E-001 7.55924E-002 665.45 1.53 768.36 4.89 806.18 1.26 934.06 3.11 1120.29 14.92 1155.21 1.63 1238.11 5.83 1280.98 1.43 1377.67 3.99 1385.31 0.79 1401.52 1.33 1407.99 2.39 1509.21 2.13 1583.20 0.70 1661.27 1.05 1729.59 2.88 1764.49 15.30 1847.43 2.03 2118.51 1.16 2204.06 4.92 2447.70 1.55 PB-214 0.659 74.82* 5.80 1.01648E+000 3.01256E-001 77.11* 9.70 3.79552E-001 1.33737E-001 86.83 1.70 87.35 2.24 89.78 0.82 241.99* 7.25 3.09278E-001 1.61515E-001 258.76 0.53 295.22 18.42 351.93* 35.60 2.61647E-001 1.52129E-001
Interference Corrected Activity Report 7/6/2017 10:10:40 AM Page 3 Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty PB-214 0.659 785.96 1.06 839.07 0.58 Ra-226 0.973 81.07 0.20 83.79 0.32 186.21* 3.64 7.14489E+000 1.84613E+000 U-235 0.999 89.96 3.43 93.35 5.54 104.82 0.69 105.60 1.31 108.58 0.50 109.19 1.66 143.76* 10.96 4.35944E-001 1.12425E-001 163.36 5.08 194.94 0.63 202.12 1.08 205.32 5.02
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance : 1.000 keV Nuclide confidence index threshold = 0.10 Errors quoted at 1.960 sigma
Interference Corrected Activity Report 7/6/2017 10:10:40 AM Page 4
- I N T E R F E R E N C E C O R R E C T E D R E P O R T *****
Nuclide Wt mean Wt mean Nuclide Id Activity Activity Name Confidence (pCi/gram) Uncertainty K-40 0.991 7.229873E+000 1.275615E+000 Pb-212 0.995 1.506312E-001 3.721987E-002 BI-214 0.296 2.046294E-001 7.555669E-002 PB-214 0.659 2.501542E-001 8.616045E-002 Ra-226 0.973 7.144895E+000 1.846127E+000 U-235 0.999 4.359442E-001 1.124249E-001
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.960 sigma
- U N I D E N T I F I E D P E A K S **********
Peak Locate Performed on: 7/6/2017 10:10:36 AM Peak Locate From Channel: 40 Peak Locate To Channel: 8192 Peak Energy Peak Size in Peak CPS Peak Tol.
No. (keV) Counts per Second % Uncertainty Type Nuclide All peaks were identified.
Nuclide MDA Report 7/6/2017 10:10:40 AM Page 5
- N U C L I D E M D A R E P O R T *****
Detector Name: 8566 Sample Geometry: cylinder Sample
Title:
UNC-GFLU-2123-S-P-1 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ K-40 1460.82* 10.66 6.151E-001 6.15E-001 7.230E+000 2.455E-00 Pb-210 46.54 4.25 1.419E+000 1.42E+000 6.642E-001 6.693E-00 BI-212 727.33 6.67 1.488E+000 1.49E+000 1.388E-001 6.903E-00 785.37 1.10 9.265E+000 -9.393E-001 4.284E+00 1078.62 0.56 2.528E+001 -9.521E+000 1.173E+00 1620.50 1.47 7.332E+000 1.221E+000 3.173E+00
+ Pb-212 74.82* 10.28 3.570E-001 5.99E-002 5.735E-001 1.703E-00 77.11* 17.10 1.904E-001 2.153E-001 9.039E-00 86.83 2.07 2.070E+000 -1.390E+000 9.976E-00 87.35 3.97 9.959E-001 -2.651E+000 4.785E-00 89.78 1.46 2.490E+000 -4.213E+000 1.193E+00 115.18 0.60 5.181E+000 8.610E-001 2.466E+00 238.63* 43.60 5.991E-002 1.586E-001 2.731E-00 300.09 3.30 1.580E+000 -3.402E+000 7.461E-00
+ BI-214 76.86* 0.55 5.975E+000 1.30E-001 6.755E+000 2.836E+00 79.29 0.91 4.850E+000 1.125E+000 2.335E+00 609.32* 45.49 1.304E-001 2.075E-001 5.858E-00 665.45 1.53 6.381E+000 -1.938E+000 2.976E+00 768.36 4.89 2.288E+000 1.747E-001 1.067E+00 806.18 1.26 8.569E+000 2.599E+000 3.973E+00 934.06 3.11 4.145E+000 2.006E+000 1.928E+00 1120.29 14.92 1.108E+000 4.126E-001 5.186E-00 1155.21 1.63 7.774E+000 -3.518E+000 3.556E+00 1238.11 5.83 2.588E+000 1.631E+000 1.196E+00 1280.98 1.43 9.783E+000 4.567E-001 4.480E+00 1377.67 3.99 2.858E+000 -4.726E-001 1.271E+00 1385.31 0.79 1.501E+001 5.365E+000 6.711E+00 1401.52 1.33 8.338E+000 1.812E+000 3.689E+00 1407.99 2.39 4.949E+000 -6.044E-001 2.207E+00 1509.21 2.13 6.556E+000 3.228E+000 2.959E+00 1583.20 0.70 1.898E+001 -5.624E+000 8.484E+00 1661.27 1.05 1.231E+001 2.826E+000 5.446E+00 1729.59 2.88 3.849E+000 2.569E+000 1.657E+00 1764.49 15.30 1.018E+000 6.077E-001 4.577E-00 1847.43 2.03 5.624E+000 -2.166E+000 2.408E+00
> 2118.51 1.16 0.000E+000 0.000E+000 0.000E+00
> 2204.06 4.92 0.000E+000 0.000E+000 0.000E+00
> 2447.70 1.55 0.000E+000 0.000E+000 0.000E+00
+ PB-214 74.82* 5.80 6.328E-001 1.24E-001 1.016E+000 3.018E-00 77.11* 9.70 3.357E-001 3.796E-001 1.594E-00 86.83 1.70 2.520E+000 -1.693E+000 1.215E+00 87.35 2.24 1.765E+000 -4.698E+000 8.481E-00
Nuclide MDA Report 7/6/2017 10:10:40 AM Page 6 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ PB-214 89.78 0.82 4.434E+000 1.24E-001 -7.501E+000 2.124E+00 241.99* 7.25 3.916E-001 3.093E-001 1.797E-00 258.76 0.53 8.132E+000 -4.288E+000 3.831E+00 295.22 18.42 3.182E-001 1.769E-001 1.514E-00 351.93* 35.60 1.236E-001 2.616E-001 5.701E-00 785.96 1.06 9.639E+000 0.000E+000 4.457E+00 839.07 0.58 1.878E+001 -8.914E+000 8.687E+00
+ Ra-226 81.07 0.20 1.826E+001 8.94E-001 -1.949E+001 8.722E+00 83.79 0.32 1.373E+001 2.106E+001 6.622E+00 186.21* 3.64 8.939E-001 7.145E+000 4.213E-00 AC-228 89.96 1.90 6.030E+004 1.56E+004 -1.067E+005 2.898E+00 93.35 3.10 3.576E+004 -3.155E+003 1.717E+00 99.51 1.26 6.518E+004 2.170E+004 3.086E+00 105.60 0.74 1.266E+005 3.785E+004 6.038E+00 129.07 2.42 3.672E+004 6.048E+003 1.744E+00 153.98 0.72 1.425E+005 7.558E+004 6.793E+00 209.25 3.89 3.168E+004 -3.807E+004 1.507E+00 214.85 0.76 1.456E+005 -8.622E+004 6.877E+00 270.24 3.46 4.021E+004 3.983E+003 1.900E+00 328.00 2.95 5.610E+004 2.207E+004 2.648E+00 338.32 11.27 1.561E+004 1.115E+004 7.379E+00 409.46 1.92 1.115E+005 3.426E+004 5.270E+00 463.00 4.40 5.075E+004 3.283E+004 2.386E+00 562.50 0.87 2.879E+005 6.914E+004 1.346E+00 674.75 2.10 1.349E+005 -1.763E+004 6.279E+00 726.86 0.62 4.754E+005 6.856E+004 2.209E+00 755.32 1.00 3.424E+005 6.753E+004 1.603E+00 772.29 1.49 2.255E+005 1.133E+005 1.053E+00 794.95 4.25 7.357E+004 2.231E+004 3.411E+00 830.49 0.54 5.713E+005 -9.139E+004 2.637E+00 835.71 1.61 2.016E+005 3.629E+004 9.339E+00 840.38 0.91 3.553E+005 -5.135E+004 1.645E+00 904.20 0.77 4.751E+005 -2.759E+005 2.210E+00 911.20 25.80 1.565E+004 1.098E+004 7.324E+00 964.77 4.99 8.343E+004 6.174E+004 3.900E+00 968.97 15.80 2.680E+004 1.406E+004 1.254E+00 1247.08 0.50 7.445E+005 -6.254E+005 3.385E+00 1459.14 0.83 1.096E+006 2.895E+006 5.250E+00 1495.91 0.86 3.715E+005 9.899E+004 1.628E+00 1588.20 3.22 1.285E+005 1.593E+004 5.777E+00 1630.63 1.51 2.033E+005 2.452E+004 8.752E+00 TH-230 67.67 0.38 1.151E+001 1.15E+001 4.184E+000 5.510E+00 PA-234 742.81 0.11 9.881E+001 1.39E+001 2.531E+001 4.598E+00 766.42 0.32 3.473E+001 -1.502E+001 1.618E+00 1001.03 0.84 1.393E+001 1.206E+001 6.399E+00 TH-234 63.29 3.70 1.207E+000 1.21E+000 2.103E-001 5.763E-00 92.38 2.13 1.931E+000 2.231E+000 9.301E-00 92.80 2.10 1.882E+000 1.063E-001 9.048E-00 112.81 0.21 1.509E+001 -6.487E+000 7.190E+00 U-234 53.20 0.12 4.008E+001 4.01E+001 2.097E+001 1.898E+00 120.90 0.04 8.767E+001 2.515E+001 4.169E+00
Nuclide MDA Report 7/6/2017 10:10:40 AM Page 7 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ U-235 89.96 3.43 1.142E+000 2.00E-001 -2.022E+000 5.489E-00 93.35 5.54 6.843E-001 -6.037E-002 3.285E-00 104.82 0.69 4.521E+000 -1.545E+000 2.152E+00 105.60 1.31 2.446E+000 7.312E-001 1.166E+00 108.58 0.50 6.698E+000 -2.426E+000 3.201E+00 109.19 1.66 2.036E+000 6.321E-001 9.734E-00 143.76* 10.96 1.996E-001 4.359E-001 9.253E-00 163.36 5.08 7.782E-001 3.928E-001 3.723E-00 194.94 0.63 6.193E+000 2.144E+000 2.943E+00 202.12 1.08 3.832E+000 1.024E-001 1.824E+00 205.32 5.02 8.764E-001 1.227E-001 4.181E-00
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
7/6/2017 10:10:40 LACE Lace v3.2.1 Page 1
- L I N E A C T I V I T Y C O N S I S T E N C Y E V A L U A T O R ***
===================================================
Analysis using Key Line Activities
===================================================
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2123\\UNC-GFLU-21 Equation used to calculate plot: ln(Ratio) = A + B*ln(Energy) where: Ratio = Activity/KL Activity Notes:
'^' Denotes Key Line energy
- All uncertainties quoted at 1.96 sigma Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]
K-40 1460.8 ^ 7.23E+000 17.644 Pb-212 74.8 5.73E-001 28.254 3.615[38.261] 4.12 -0.755 77.1 2.15E-001 34.066 1.357[42.733] [ 0.404]
238.6 ^ 1.59E-001 25.799 1.000[36.485]
BI-214 76.9 6.76E+000 34.184 32.553[49.955] 10.79 -1.682 609.3 ^ 2.08E-001 36.427 1.000[51.516] [ 0.347]
PB-214 74.8 1.02E+000 29.637 3.885[65.261] 3.49 -0.601 77.1 3.80E-001 35.236 1.451[67.986] [ 0.542]
242.0 3.09E-001 52.223 1.182[78.153]
351.9 ^ 2.62E-001 58.143 1.000[82.226]
Ra-226 186.2 ^ 7.14E+000 25.838 U-235 143.8 ^ 4.36E-001 25.789