          • G A M M A S P E C T R U M A N A L Y S I S *****

Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-1742\\GFLU-1742-S Report Generated On : 7/6/2017 10:06:40 AM Sample Title : W3H-GFLU-1742-S-P-2 Sample Description :

Sample Identification : DGFLU-1742-S-P-2 Sample Type :

Sample Geometry : cylinder Peak Locate Threshold : 3.00 Peak Locate Range (in channels) : 40 - 8192 Peak Area Range (in channels) : 40 - 8192 Identification Energy Tolerance : 1.000 keV Sample Size : 3.489E+002 grams Sample Taken On : 6/7/2017 2:00:00 PM Acquisition Started : 6/16/2017 8:33:33 AM Live Time : 1800.0 seconds Real Time : 1800.4 seconds Dead Time : 0.02 %

Energy Calibration Used Done On : 4/13/2017 Efficiency Calibration Used Done On : 7/6/2017 Efficiency ID : H-IMC-2002-S-P-5

Peak Analysis Report 7/6/2017 10:06:40 AM Page 1

          • P E A K A N A L Y S I S R E P O R T *****

Detector Name: 8566 Sample

Title:

W3H-GFLU-1742-S-P-2 Peak Analysis Performed on: 7/6/2017 10:06:35 AM Peak Analysis From Channel: 40 Peak Analysis To Channel: 8192 Peak ROI ROI Peak Energy FWHM Net Peak Net Area Continuum No. start end centroid (keV) (keV) Area Uncert. Counts M 1 294-313 299.60 75.08 0.68 1.17E+002 60.51 1.32E+002 m 2 294-313 308.19 77.23 0.69 1.29E+002 64.57 9.17E+001 F 3 735-750 742.36 185.88 0.98 1.03E+002 67.21 7.60E+001 F 4 946-959 953.04 238.60 0.86 1.38E+002 25.73 8.23E+001 F 5 1174-1185 1179.33 295.23 0.98 4.02E+001 46.83 3.48E+001 F 6 1396-1411 1405.58 351.85 0.76 8.80E+001 48.79 4.00E+001 F 7 2425-2440 2432.49 608.83 1.19 5.64E+001 17.41 2.80E+001 F 8 5823-5849 5835.34 1460.37 2.61 1.83E+002 27.27 6.00E+000 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma

Interference Corrected Activity Report 7/6/2017 10:06:40 AM Page 2

          • N U C L I D E I D E N T I F I C A T I O N R E P O R T *****

Sample

Title:

W3H-GFLU-1742-S-P-2 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201

.................... IDENTIFIED NUCLIDES....................

Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty K-40 0.968 1460.82* 10.66 8.64957E+000 1.43675E+000 Pb-212 0.998 74.82* 10.28 7.34090E-001 3.91946E-001 77.11* 17.10 4.76268E-001 2.46527E-001 86.83 2.07 87.35 3.97 89.78 1.46 115.18 0.60 238.63* 43.60 2.79606E-001 5.91392E-002 300.09 3.30 BI-214 0.208 76.86* 0.55 1.49434E+001 7.74672E+000 79.29 0.91 609.32* 45.49 2.85040E-001 9.05761E-002 665.45 1.53 768.36 4.89 806.18 1.26 934.06 3.11 1120.29 14.92 1155.21 1.63 1238.11 5.83 1280.98 1.43 1377.67 3.99 1385.31 0.79 1401.52 1.33 1407.99 2.39 1509.21 2.13 1583.20 0.70 1661.27 1.05 1729.59 2.88 1764.49 15.30 1847.43 2.03 2118.51 1.16 2204.06 4.92 2447.70 1.55 PB-214 0.852 74.82* 5.80 1.30111E+000 7.04378E-001 77.11* 9.70 8.39606E-001 4.41124E-001 86.83 1.70 87.35 2.24 89.78 0.82 241.99 7.25 258.76 0.53 295.22* 18.42 2.36609E-001 2.76784E-001 351.93* 35.60 3.21960E-001 1.80497E-001

Interference Corrected Activity Report 7/6/2017 10:06:40 AM Page 3 Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty PB-214 0.852 785.96 1.06 839.07 0.58 Ra-226 0.985 81.07 0.20 83.79 0.32 186.21* 3.64 2.01385E+000 1.33218E+000

  • = Energy line found in the spectrum.

@ = Energy line not used for Weighted Mean Activity Energy Tolerance : 1.000 keV Nuclide confidence index threshold = 0.10 Errors quoted at 1.960 sigma

Interference Corrected Activity Report 7/6/2017 10:06:40 AM Page 4

          • I N T E R F E R E N C E C O R R E C T E D R E P O R T *****

Nuclide Wt mean Wt mean Nuclide Id Activity Activity Name Confidence (pCi/gram) Uncertainty K-40 0.968 8.649571E+000 1.436745E+000 Pb-212 0.998 2.857132E-001 5.689036E-002 BI-214 0.208 2.850419E-001 9.054937E-002 PB-214 0.852 3.192715E-001 1.405476E-001 Ra-226 0.985 2.013853E+000 1.332180E+000

? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis

@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.960 sigma

                    • U N I D E N T I F I E D P E A K S **********

Peak Locate Performed on: 7/6/2017 10:06:35 AM Peak Locate From Channel: 40 Peak Locate To Channel: 8192 Peak Energy Peak Size in Peak CPS Peak Tol.

No. (keV) Counts per Second % Uncertainty Type Nuclide All peaks were identified.

Nuclide MDA Report 7/6/2017 10:06:40 AM Page 5

          • N U C L I D E M D A R E P O R T *****

Detector Name: 8566 Sample Geometry: cylinder Sample

Title:

W3H-GFLU-1742-S-P-2 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 NLB 0328201 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram

+ K-40 1460.82* 10.66 7.312E-001 7.31E-001 8.650E+000 3.016E-00 Pb-210 46.54 4.25 1.458E+000 1.46E+000 8.841E-001 6.877E-00 BI-212 727.33 6.67 1.658E+000 1.66E+000 9.825E-001 7.737E-00 785.37 1.10 1.023E+001 -2.719E+000 4.757E+00 1078.62 0.56 2.456E+001 8.622E-002 1.135E+00 1620.50 1.47 8.447E+000 5.438E+000 3.714E+00

+ Pb-212 74.82* 10.28 3.519E-001 1.05E-001 7.341E-001 1.675E-00 77.11* 17.10 1.743E-001 4.763E-001 8.218E-00 86.83 2.07 2.137E+000 2.267E+000 1.030E+00 87.35 3.97 1.026E+000 -1.671E+000 4.928E-00 89.78 1.46 2.633E+000 -2.348E+000 1.263E+00 115.18 0.60 5.557E+000 1.571E+000 2.650E+00 238.63* 43.60 1.054E-001 2.796E-001 4.998E-00 300.09 3.30 1.759E+000 -1.171E+000 8.344E-00

+ BI-214 76.86* 0.55 5.470E+000 1.48E-001 1.494E+001 2.578E+00 79.29 0.91 5.080E+000 3.417E-001 2.447E+00 609.32* 45.49 1.481E-001 2.850E-001 6.719E-00 665.45 1.53 6.248E+000 -2.048E+000 2.902E+00 768.36 4.89 2.362E+000 8.223E-001 1.102E+00 806.18 1.26 8.847E+000 7.014E+000 4.102E+00 934.06 3.11 4.377E+000 -2.554E-001 2.039E+00 1120.29 14.92 9.853E-001 -1.010E-002 4.562E-00 1155.21 1.63 1.002E+001 8.212E+000 4.666E+00 1238.11 5.83 2.697E+000 1.168E+000 1.247E+00 1280.98 1.43 1.160E+001 8.172E+000 5.373E+00 1377.67 3.99 3.776E+000 9.891E-001 1.725E+00 1385.31 0.79 1.688E+001 -1.857E+001 7.616E+00 1401.52 1.33 9.842E+000 -2.380E+000 4.425E+00 1407.99 2.39 5.489E+000 4.753E+000 2.468E+00 1509.21 2.13 5.604E+000 -4.064E-002 2.472E+00 1583.20 0.70 2.100E+001 6.361E+000 9.460E+00 1661.27 1.05 1.213E+001 7.754E+000 5.333E+00 1729.59 2.88 4.901E+000 2.795E+000 2.175E+00 1764.49 15.30 1.015E+000 -1.642E-001 4.547E-00 1847.43 2.03 6.205E+000 -5.182E+000 2.685E+00

> 2118.51 1.16 0.000E+000 0.000E+000 0.000E+00

> 2204.06 4.92 0.000E+000 0.000E+000 0.000E+00

> 2447.70 1.55 0.000E+000 0.000E+000 0.000E+00

+ PB-214 74.82* 5.80 6.237E-001 1.33E-001 1.301E+000 2.968E-00 77.11* 9.70 3.073E-001 8.396E-001 1.449E-00 86.83 1.70 2.602E+000 2.761E+000 1.254E+00 87.35 2.24 1.818E+000 -2.962E+000 8.734E-00

Nuclide MDA Report 7/6/2017 10:06:40 AM Page 6 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram

+ PB-214 89.78 0.82 4.688E+000 1.33E-001 -4.180E+000 2.248E+00 241.99 7.25 1.019E+000 2.185E-001 4.926E-00 258.76 0.53 9.070E+000 2.330E+000 4.292E+00 295.22* 18.42 1.856E-001 2.366E-001 8.482E-00 351.93* 35.60 1.326E-001 3.220E-001 6.137E-00 785.96 1.06 1.065E+001 -4.847E+000 4.949E+00 839.07 0.58 1.795E+001 -5.690E+000 8.250E+00

+ Ra-226 81.07 0.20 1.687E+001 1.02E+000 3.483E+000 8.015E+00 83.79 0.32 1.249E+001 9.789E+000 5.991E+00 186.21* 3.64 1.025E+000 2.014E+000 4.860E-00 AC-228 89.96 1.90 4.393E+010 1.17E+010 -7.881E+010 2.110E+01 93.35 3.10 2.531E+010 4.060E+009 1.213E+01 99.51 1.26 4.897E+010 3.708E+010 2.321E+01 105.60 0.74 9.060E+010 3.340E+010 4.315E+01 129.07 2.42 2.625E+010 -4.823E+009 1.245E+01 153.98 0.72 9.060E+010 -1.157E+010 4.285E+01 209.25 3.89 2.471E+010 8.020E+009 1.179E+01 214.85 0.76 1.150E+011 -1.317E+011 5.454E+01 270.24 3.46 3.065E+010 2.152E+009 1.452E+01 328.00 2.95 4.125E+010 -4.698E+009 1.947E+01 338.32 11.27 1.169E+010 2.656E+009 5.532E+00 409.46 1.92 7.216E+010 -2.105E+010 3.384E+01 463.00 4.40 3.403E+010 3.360E+009 1.590E+01 562.50 0.87 2.159E+011 8.897E+009 1.011E+01 674.75 2.10 9.301E+010 -4.159E+010 4.309E+01 726.86 0.62 3.660E+011 9.166E+009 1.706E+01 755.32 1.00 2.098E+011 -7.028E+010 9.692E+01 772.29 1.49 1.490E+011 -9.083E+010 6.902E+01 794.95 4.25 5.589E+010 1.163E+010 2.598E+01 830.49 0.54 4.240E+011 1.182E+011 1.959E+01 835.71 1.61 1.457E+011 9.182E+010 6.739E+01 840.38 0.91 2.520E+011 3.776E+010 1.163E+01 904.20 0.77 3.829E+011 -3.336E+011 1.792E+01 911.20 25.80 1.263E+010 1.241E+010 5.947E+00 964.77 4.99 5.753E+010 3.214E+010 2.677E+01 968.97 15.80 1.796E+010 5.927E+009 8.348E+00 1247.08 0.50 6.287E+011 -9.518E+010 2.895E+01 1459.14 0.83 8.853E+011 2.315E+012 4.255E+01 1495.91 0.86 2.510E+011 3.536E+010 1.086E+01 1588.20 3.22 9.906E+010 6.384E+010 4.478E+01 1630.63 1.51 1.337E+011 -3.223E+010 5.645E+01 TH-230 67.67 0.38 1.195E+001 1.19E+001 -3.108E-002 5.722E+00 PA-234 742.81 0.11 1.051E+002 1.60E+001 3.658E+001 4.900E+00 766.42 0.32 3.741E+001 1.958E+001 1.748E+00 1001.03 0.84 1.598E+001 4.872E+000 7.403E+00 TH-234 63.29 3.70 1.350E+000 1.35E+000 -1.861E-001 6.471E-00 92.38 2.13 1.943E+000 3.685E+000 9.350E-00 92.80 2.10 1.894E+000 1.537E+000 9.098E-00 112.81 0.21 1.487E+001 -5.034E+000 7.070E+00 U-234 53.20 0.12 4.102E+001 4.10E+001 -9.683E+000 1.942E+00 120.90 0.04 8.846E+001 1.615E+001 4.202E+00

Nuclide MDA Report 7/6/2017 10:06:40 AM Page 7 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram U-235 89.96 3.43 1.168E+000 3.12E-001 -2.096E+000 5.612E-00 93.35 5.54 6.801E-001 1.091E-001 3.260E-00 104.82 0.69 4.567E+000 -2.407E+000 2.172E+00 105.60 1.31 2.457E+000 9.058E-001 1.170E+00 108.58 0.50 6.347E+000 1.055E+000 3.021E+00 109.19 1.66 1.849E+000 -1.555E+000 8.784E-00 143.76 10.96 3.124E-001 4.434E-002 1.487E-00 163.36 5.08 6.991E-001 6.732E-002 3.322E-00 194.94 0.63 6.539E+000 -4.838E-001 3.111E+00 202.12 1.08 3.826E+000 -1.761E-002 1.818E+00 205.32 5.02 8.686E-001 -1.919E-003 4.135E-00

+ = Nuclide identified during the nuclide identification

  • = Energy line found in the spectrum

> = MDA value not calculated

@ = Half-life too short to be able to perform the decay correction

7/6/2017 10:06:40 LACE Lace v3.2.1 Page 1

        • L I N E A C T I V I T Y C O N S I S T E N C Y E V A L U A T O R ***
===================================================

Analysis using Key Line Activities

===================================================

Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-1742\\GFLU-1742-S Equation used to calculate plot: ln(Ratio) = A + B*ln(Energy) where: Ratio = Activity/KL Activity Notes:

'^' Denotes Key Line energy

  • All uncertainties quoted at 1.96 sigma Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]

K-40 1460.8 ^ 8.65E+000 16.611 Pb-212 74.8 7.34E-001 53.392 2.625[57.429] 3.57 -0.653 77.1 4.76E-001 51.762 1.703[55.917] [ 0.437]

238.6 ^ 2.80E-001 21.151 1.000[29.912]

BI-214 76.9 1.49E+001 51.840 52.426[60.804] 12.26 -1.912 609.3 ^ 2.85E-001 31.777 1.000[44.939] [ 0.365]

PB-214 74.8 1.30E+000 54.137 4.041[77.934] 4.80 -0.839 77.1 8.40E-001 52.539 2.608[76.833] [ 0.584]

295.2 2.37E-001 116.98 0.735[129.72]

351.9 ^ 3.22E-001 56.062 1.000[79.283]

Ra-226 186.2 ^ 2.01E+000 66.151