Category:Legal-Affidavit
MONTHYEARML20150E1772020-05-29029 May 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Extended Dhrs Operation and RCS Boron Redistribution (Closed Session), PM-0620-70243, Revision 0 ML20141L8082020-05-20020 May 2020 LLC Submittal of Containment Response Analysis Methodology Technical Report, TR-0516-49084, Revision 3 ML20133K0882020-05-12012 May 2020 LLC, Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution (Closed Session), PM-0420-69512, Revision 0 RAIO-0420-69855, LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification2020-04-30030 April 2020 LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification ML20066H1812020-02-28028 February 2020 LLC, Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale FSAR Chapter 19 - Probabilistic Risk Assessment Area of Focus, PM-0220-69046, Revision 0 ML20066H1842020-02-28028 February 2020 LLC Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale FSAR Topic-Resolution of Chapter 15 Phase 2 Open Items (Closed Session), PM-0220-69063, Revision 0 ML20054A4112020-02-17017 February 2020 LLC - Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topical Report - Loss-of-Coolant Accident Evaluation Model (Closed Session), PM-0220-68914, Revision 0 ML20054A9652020-02-17017 February 2020 LLC, Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topical Report - Rod Ejection Accident Methodology (Closed Session), PM-1019-67366, Revision 0 ML20054A9692020-02-17017 February 2020 LLC Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topical Report- Non-Loss-of-Coolant Accident (Closed Session), PM-0220-68851, Revision 0 ML19353A7192019-12-19019 December 2019 LLC, Submittal of NuFuel-HTP2 Fuel and Control Rod Assembly Designs, TR-0816-51127, Revision 3 ML19352G6972019-12-18018 December 2019 LLC Submittal of Long-Term Cooling Methodology, TR-0916-51299, Revision 2 ML19338E9482019-12-0404 December 2019 LLC Submittal of Human-System Interface Style Guide, ES-0304-1381, Revision 4 ML19337B4472019-12-0202 December 2019 LLC - Submittal of Changes to Long-Term Cooling Methodology, TR-0916-51299, Revision 1 ML19332A1202019-11-27027 November 2019 LLC Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19304B4712019-10-31031 October 2019 LLC Supplemental Response to NRC Request for Additional Information No. 466 (Erai No. 9482) on the NuScale Design Certification Application ML19238A3092019-08-26026 August 2019 LLC - Submittal Nuscale'S Proposed Closure Plan to Address Impacts of the Adjusted Iab Operations Range ML19238A3662019-08-23023 August 2019 LLC - Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19218A1472019-08-0505 August 2019 LLC - Submittal of Long-Term Cooling Methodology, TR-0916-51299, Revision 1 ML19215A0062019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 441 (Erai No. 9485) on the NuScale Design Certification Application ML19215A0032019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19212A3752019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 483 (Erai No. 9516) on the NuScale Design Certification Application ML19212A7992019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19211D4112019-07-30030 July 2019 LLC Submittal of NuScale Power Module Short-Term Transient Analysis, TR-1016-51669, Revision 1 ML19207B3812019-07-26026 July 2019 LLC - Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19199A1172019-07-18018 July 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19192A1602019-07-0909 July 2019 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report-Evaluation Methodology for Stability Analysis of the NuScale Power Module, PM-0719-66244, Revision 0 ML19184A6152019-07-0303 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 386 (Erai No. 9316) on the NuScale Design Certification Application ML19183A4852019-07-0202 July 2019 LLC - Submittal of Fluence Calculation Methodology and Results, TR-0116-20781, Revision 1 ML19182A0462019-06-27027 June 2019 LLC - Submittal of Presentation Materials Titled TF-3 Modal Demonstration Testing and Siet Tour, PM-0619-66058-P, Revision 0 ML19176A5802019-06-25025 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19172A1012019-06-17017 June 2019 LLC - Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation, NuScale FSAR Chapter 15, Transient and Accident Analyses, and Chapter 6.2.1, Containment Functional Design, PM-0619-65992-P, Revision 0 ML19164A1452019-06-13013 June 2019 LLC - Submittal of Containment Response Analysis Methodology Technical Report, TR-0516 -49 08 4, Revision 1 ML19158A3822019-06-0707 June 2019 LLC - Submittal of Containment Vessel Ultimate Pressure Integrity, TR-0917-56119, Revision 1 ML19157A3262019-06-0606 June 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19154A6222019-06-0303 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19154A6052019-06-0303 June 2019 LLC Response to NRC Request for Additional Information No. 514 (Erai No. 9645) on the NuScale Design Certification Application ML19151A8102019-05-31031 May 2019 LLC Submittal of Technical Report NuScale Generic Technical Guidelines, TR-1117-57216, Revision 1 ML19151A8372019-05-31031 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 377 (Erai No. 9380) on the NuScale Design Certification Application ML19151A8342019-05-31031 May 2019 LLC - Submittal of Turbine Missile Barrier Design Closure Plan Actions (Final Safety Analysis Report, Tier 2, Section 3.5.1.3) ML19149A2982019-05-28028 May 2019 LLC Submittal of NuScale Containment Leakage Integrity Assurance, TR-1116-51962, Revision 1 ML19137A3612019-05-17017 May 2019 LLC - Submittal of Nuclear Steam Supply System Advanced Sensor Technical Report, TR-0316-22048, Revision 2 ML19119A3982019-04-29029 April 2019 LLC - Submittal of Human-System Interface Design Results Summary Report, RP-0316-17619, Revision 2 ML19119A3422019-04-29029 April 2019 LLC Submittal of Human Factors Engineering Program Management Plan, RP-0914-8534, Revision 5 ML19119A3932019-04-29029 April 2019 LLC - Submittal of Human Factors Engineering Task Analysis Results Summary Report, RP-0316-17616 Revision 2. (Non-Proprietary Version) ML19105B0772019-04-15015 April 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 478 (Erai No. 9470) on the NuScale Design Certification Application ML19101A4412019-04-11011 April 2019 LLC Response to NRC Request for Additional Information No. 386 (Erai No. 9316) on the NuScale Design Certification Application ML19099A4732019-04-0909 April 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19098B6202019-04-0808 April 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 465 (Erai No. 9494) on the NuScale Design Certification Application ML19093B8502019-04-0303 April 2019 LLC - Submittal of Technical Report TR-0916-51502, NuScale Power Module Seismic Analysis, Revision 2 ML19087A2882019-03-28028 March 2019 LLC Updates to Final Safety Analysis Report, Section 1.6,Materials Referenced, Section 3.6, Protection Against Dynamic Effects Associated with Postulated Rupture of Piping, and the Pipe Rupture Hazards Analysis, TR-0818-61384 2020-05-29
[Table view] Category:Letter
MONTHYEARML23180A1512023-06-29029 June 2023 LLC, Request for Exemption to the Reporting Requirements of 10 CFR 50.46(a)(3) ML21102A3072021-04-15015 April 2021 OEDO-21-00155 - Lessons-Learned from the Design Certification Review of the NuScale Power, LLC, Small Modular Reactor ML21050A4312021-02-19019 February 2021 LLC - Lessons-Learned from the Design Certification Review of the NuScale Power, LLC Small Modular Reactor ML20247J5642020-09-11011 September 2020 Standard Design Approval for the NuScale Power Plant Based on the NuScale 600 Standard Plant Design Certification Application ML20231A8042020-08-28028 August 2020 Final Safety Evaluation Report for the NuScale Standard Plant Design ML20224A4602020-08-25025 August 2020 OEDO-20-00292-Response to the Advisory Committee on Reactor Safeguards Letter on NuScale Power, LLC, Report on the Safety Aspects of the NuScale Small Modular Reactor ML20231A5982020-08-25025 August 2020 OEDO-20-00285_NuScale Area of Focus - Boron Redistribution ML20210M8902020-07-29029 July 2020 Area of Focus - Boron Redistribution ML20195A5872020-07-13013 July 2020 LLC - Submittal of Draft Operator Licensing and Examination Standard for NuScale Small Modular Reactors ML20195C7662020-07-13013 July 2020 LLC Request for Standard Design Approval Based on the NuScale Standard Plant Design Certification Application ML20192A3262020-07-10010 July 2020 LLC, Submittal of Environmental Report: Revision Status ML20198M3932020-07-0202 July 2020 LLC Submittal of Revised Packing Slip for Submittal of the NuScale Standard Plant Design Certification Application, Revision 4.1, Dated June 19, 2020 ML20174A3472020-07-0101 July 2020 OEDO-20-00220 - Area of Focus - Probabilistic Risk Assessment and Emergency Core Cooling System Valve Performance ML20184A2872020-07-0101 July 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Boron Redistribution and General Design Criterion 33, PM-0720-70785, Revision 0 ML20181A4322020-06-22022 June 2020 Final SER for NuScale TR-0516-49416 NON-Loss-of-Coolant Analysis Model, Rev 3 (Letter) ML20181A2702020-06-22022 June 2020 Final SER for NuScale TR-0516-49422 Loss-of-Coolant Analysis Model, Rev 2 (Letter) ML20198M3922020-06-19019 June 2020 LLC - Submittal of the NuScale Standard Plant Design Certification Application, Revision 4.1 ML20171A7312020-06-19019 June 2020 LLC, Submittal of Riser Flow Hole Methodology and Associated Changes to Final Safety Analysis Report Incorporating Its Use ML20157A2232020-06-0303 June 2020 Letter to NuScale Requesting -A for TR-0716-50350 ML20150C5172020-05-29029 May 2020 LLC Submittal of Presentation Materials Entitled NRC Public Meeting Presentation: Boron Redistribution and Associated Design and DCA Changes, PM-0620-70336, Revision 0 ML20150E1772020-05-29029 May 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Extended Dhrs Operation and RCS Boron Redistribution (Closed Session), PM-0620-70243, Revision 0 ML20150C8812020-05-29029 May 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Boron Redistribution and Associated Design and DCA Changes, PM-0620-70244, Revision 0 ML20149M1192020-05-28028 May 2020 LLC Summary of Impacts to Erai 8930 Response and Discussion on the Exemption from General Design Criterion 33 ML20141L8082020-05-20020 May 2020 LLC Submittal of Containment Response Analysis Methodology Technical Report, TR-0516-49084, Revision 3 ML20141N0122020-05-20020 May 2020 LLC Submittal of Changes to Final Safety Analysis Report, Section 6.2, Containment Systems, Section 6.3, Emergency Core Cooling System, and Technical Report TR-0516-49084, Containment Response Analysis Methodology Technical Report ML20141M7642020-05-20020 May 2020 LLC Submittal of Nuclear Steam Supply System Advanced Sensor Technical Report, TR-0316-22048, Revision 3 ML20141L7872020-05-20020 May 2020 LLC, Submittal of Second Updates to Standard Plant Design Certification Application, Revision 4 ML20141L8162020-05-20020 May 2020 LLC, Submittal of Long-Term Cooling Methodology, TR-0916-51299, Revision 3 ML20141M1142020-05-20020 May 2020 LLC Submittal of NuScale Instrument Setpoint Methodology Technical Report, TR-0616-49121, Revision 3 ML20141L8042020-05-20020 May 2020 LLC Submittal of Technical Specifications Regulatory Conformance and Development, TR-1116-52011, Revision 4 ML20128J3162020-05-18018 May 2020 OEDO-20-00167 - Response to the ACRS Letter on Combustible Gas Monitoring ML20133K0882020-05-12012 May 2020 LLC, Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution (Closed Session), PM-0420-69512, Revision 0 ML20133J9142020-05-11011 May 2020 LLC Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution, PM-0420-69511, Revision 0 ML20112F4552020-05-0101 May 2020 LLC, Design Certification Application Phases 5 and 6 Review Status ML20107F8492020-05-0101 May 2020 OEDO-2000140 - NuScale Area of Focus - Helical Tube Steam Generator Design ML20104A0792020-04-27027 April 2020 OEDO-20-00115 - Safety Evaluation Report for Topical Report TR-0516-49416, Revision 2, Non-Loss-of-Coolant Accident Analysis Methodology ML20099H0802020-04-0808 April 2020 LLC - Submittal of Presentation Materials Entitled NRC Public Meeting: Revisions to Nuscale'S EPZ Sizing Methodology Topical Report, PM-0420-69598, Revision 0 ML20098G2372020-04-0707 April 2020 Nuscale Power, LLC Submittal of Remaining Closure Items for the Emergency Core Cooling System Valve Failure Mode Effects Analysis Audit Items ML20097F1922020-04-0606 April 2020 Nuscale Power, LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: Nuscale Topic - Hydrogen/Oxygen Monitoring, PM-0420-69518, Revision 0 ML20094H6742020-04-0303 April 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation NuScale Topic-Probabilistic Risk Assessment with a Focus on Emergency Core Cooling System Analysis PM-0420-69559, Revision 0 ML20092L8992020-04-0101 April 2020 LLC - Submittal of Updates to Standard Plant Design Certification Application, Revision 4 ML20072M6682020-03-30030 March 2020 Response to NuScale Letter Dated February 24, 2020, on Planned SDA Application Content ML20072H3332020-03-0909 March 2020 LLC - Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution, PM-0320-69218, Revision 0 ML20057D9002020-03-0606 March 2020 Submittal of Errata to Final SE for NuScale Power, LLC TR-1010-859-NP-A, Quality Assurance Program Description for the NuScale Power Plant ML20062F7262020-03-0505 March 2020 Request for Withholding Information from Public Disclosure for Nuscale Power, LLC Letter Public ML20069A1572020-03-0404 March 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report-Rod Ejection Accident Methodology, PM-0320-69146, Revision 0 ML20069A1772020-03-0404 March 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report-Non-Loss-of-Coolant Accident, PM-0320-69141, Revision 0 ML20069A9632020-03-0404 March 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report, Loss-of-Coolant Accident Evaluation Model, PM-0320-69138, Revision 0 ML20066G2802020-03-0303 March 2020 LLC, Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topic - Hydrogen Monitoring, PM-0220-69071, Revision 0 ML20066G2882020-02-28028 February 2020 LLC Submittal of Presentation Materials Titled ACRS Full Committee Presentation: NuScale - Steam Generator Design (Closed Session), PM-0220-69053, Revision 0 2023-06-29
[Table view] Category:Response to Request for Additional Information (RAI)
MONTHYEARRAIO-0420-69855, LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification2020-04-30030 April 2020 LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification ML19332A1202019-11-27027 November 2019 LLC Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19304B4712019-10-31031 October 2019 LLC Supplemental Response to NRC Request for Additional Information No. 466 (Erai No. 9482) on the NuScale Design Certification Application ML19296D8052019-10-23023 October 2019 LLC Response to NRC Request for Additional Information No. 526 (Erai No. 9719) on the NuScale Design Certification Application ML19283E5302019-10-10010 October 2019 LLC Supplemental Response to NRC Request for Additional Information No. 522 (Erai No. 9681) on the NuScale Design Certification Application ML19260G7352019-10-0707 October 2019 Summary of Public Meeting with NuScale to Discuss Response to RAI 9681 ML19266A5872019-09-23023 September 2019 LLC Supplemental Response to NRC Request for Additional Information No. 518 (Erai No. 9659) on the NuScale Design Certification Application ML19262G9742019-09-19019 September 2019 LLC - Submittal of Changes to Final Safety Analysis Report, Tier 1, Section 3.11, Reactor Building and Section 3.13, Control Building, and Tier 2, Section 3.8.4, Design of Category I Structure and Section 14.3, Certified ... ML19262G5762019-09-19019 September 2019 LLC - Submittal of Changes to Final Safety Analysis Report, Section 14.2, Initial Plant Test Program, Table 14.2-2, Pool Cleanup Systems Test #2, and Table 14.2-50, Module Assembly Equipment Test #50 ML19259B8102019-09-16016 September 2019 LLC Supplemental Response to NRC Request for Additional Information No. 205 (Erai No. 9044) on the NuScale Design Certification Application ML19259A0922019-09-16016 September 2019 LLC Response to NRC Request for Additional Information No. 525 (Erai No. 9705) on the NuScale Design Certification Application ML19238A3722019-08-26026 August 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19238A3662019-08-23023 August 2019 LLC - Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19215A0032019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19215A0062019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 441 (Erai No. 9485) on the NuScale Design Certification Application ML19212A7622019-07-31031 July 2019 LLC Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19212A3752019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 483 (Erai No. 9516) on the NuScale Design Certification Application ML19212A7992019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19212A6892019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 205 (Erai No. 9044) on the NuScale Design Certification Application ML19210D1592019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 401 (Erai No. 9447) on the NuScale Design Certification Application ML19210D7342019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 520 (Erai No. 9642) on the NuScale Design Certification Application ML19210E1462019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19207B3812019-07-26026 July 2019 LLC - Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19207A5342019-07-26026 July 2019 LLC - Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19207B8522019-07-25025 July 2019 LLC Response to NRC Request for Additional Information No. 194 (Erai No. 8884) on the NuScale Design Certification Application ML19203A3152019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 325 (Erai No. 9268) on the NuScale Design Certification Application ML19203A3212019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 333 (Erai No. 9282) on the NuScale Design Certification Application ML19203A3092019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 54 (Erai No. 8837) on the NuScale Design Certification Application ML19203A3422019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 154 (Erai No. 8938) on the NuScale Design Certification Application ML19200A2482019-07-19019 July 2019 LLC Response to NRC Request for Additional Information No. 522 (Erai No. 9681) on the NuScale Design Certification Application ML19200A2082019-07-19019 July 2019 LLC - Response to NRC Request for Additional Information No. 524 (Erai No. 9691) on the NuScale Design Certification Application ML19199A1172019-07-18018 July 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19198A3252019-07-17017 July 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 249 (Erai No. 9135) on the NuScale Design Certification Application ML19196A3682019-07-15015 July 2019 LLC Response to NRC Request for Additional Information No. 516 (Erai No. 9647) on the NuScale Design Certification Application ML19191A2202019-07-10010 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19184A6152019-07-0303 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 386 (Erai No. 9316) on the NuScale Design Certification Application ML19176A5802019-06-25025 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19170A3702019-06-19019 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19168A2442019-06-17017 June 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 325 (Erai No. 9268) on the NuScale Design Certification Application ML19164A1452019-06-13013 June 2019 LLC - Submittal of Containment Response Analysis Methodology Technical Report, TR-0516 -49 08 4, Revision 1 ML19157A3262019-06-0606 June 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19154A6222019-06-0303 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19154A6052019-06-0303 June 2019 LLC Response to NRC Request for Additional Information No. 514 (Erai No. 9645) on the NuScale Design Certification Application ML19151A8372019-05-31031 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 377 (Erai No. 9380) on the NuScale Design Certification Application ML19140A4592019-05-20020 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 401 (Erai No. 9447) on the NuScale Design Certification Application ML19137A2902019-05-17017 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 156 (Erai No. 9031) on the NuScale Design Certification Application ML19137A2872019-05-15015 May 2019 LLC Response to NRC Request for Additional Information No. 519 (Erai No. 9656) on the NuScale Design Certification Application ML19126A2942019-05-0606 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 26 (Erai No. 8840) on the NuScale Design Certification Application ML19122A5092019-05-0202 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 494 (Erai No. 9548)on the Design Certification Application ML19121A6002019-05-0101 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on Design Certification Application 2020-04-30
[Table view] |
Text
RAIO-0219-64685 February 26, 2019 Docket No.52-048 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
NuScale Power, LLC Supplemental Response to NRC Request for Additional Information No. 161 (eRAI No. 9043) on the NuScale Design Certification Application
REFERENCES:
- 1. U.S. Nuclear Regulatory Commission, "Request for Additional Information No. 161 (eRAI No. 9043)," dated August 11, 2017
- 2. NuScale Power, LLC Response to NRC "Request for Additional Information No. 161 (eRAI No.9043)," dated October 10, 2017 The purpose of this letter is to provide the NuScale Power, LLC (NuScale) supplemental response to the referenced NRC Request for Additional Information (RAI).
The Enclosures to this letter contain NuScale's supplemental response to the following RAI Question from NRC eRAI No. 9043:
19-26 is the proprietary version of the NuScale Supplemental Response to NRC RAI No.
161 (eRAI No. 9043). NuScale requests that the proprietary version be withheld from public disclosure in accordance with the requirements of 10 CFR § 2.390. The enclosed affidavit (Enclosure 3) supports this request. Enclosure 2 is the nonproprietary version of the NuScale response.
This letter and the enclosed responses make no new regulatory commitments and no revisions to any existing regulatory commitments.
If you have any questions on this response, please contact Paul Infanger at 541-452-7351 or at pinfanger@nuscalepower.com.
Sincerely, Zackary W. Rad Director, Regulatory Affairs NuScale Power, LLC Distribution: Gregory Cranston, NRC, OWFN-8H12 Samuel Lee, NRC, OWFN-8H12 Rani Franovich, NRC, OWFN-8H12 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
RAIO-0219-64685 : NuScale Supplemental Response to NRC Request for Additional Information eRAI No. 9043, proprietary : NuScale Supplemental Response to NRC Request for Additional Information eRAI No. 9043, nonproprietary : Affidavit of Zackary W. Rad, AF-0219-64686 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
RAIO-0219-64685 :
NuScale Supplemental Response to NRC Request for Additional Information eRAI No. 9043, proprietary NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
RAIO-0219-64685 :
NuScale Supplemental Response to NRC Request for Additional Information eRAI No. 9043, nonproprietary NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
Response to Request for Additional Information Docket No.52-048 eRAI No.: 9043 Date of RAI Issue: 08/11/2017 NRC Question No.: 19-26 Regulatory Basis 10 CFR 52.47(a)(27) states that a Design Certification (DC) application must contain a Final Safety Analysis Report (FSAR) that includes a description of the design-specific probabilistic risk assessment (PRA) and its results. 10 CFR 52.47(a)(23) states that a DC application for light-water reactor (LWR) designs must contain an FSAR that includes a description and analysis of design features for the prevention and mitigation of severe accidents (e.g.,
challenges to containment integrity caused by core- concrete interaction, steam explosion, high-pressure melt ejection, hydrogen combustion, and containment bypass). Standard Review Plan 19.0 acceptance criteria for the applicants severe accident analyses include a large release frequency of less than 10-6 per year and a conditional containment failure probability of less than 0.1. The staff must make a finding that the applicant has performed an adequate evaluation of the risk from severe accidents.
Request for additional information The applicants PRA and description and analysis of design features for prevention and mitigation of severe accidents included an analysis of in-vessel retention of corium in the reactor vessel lower plenum and the containment lower plenum. The staff reviewed the applicants analysis of in-vessel retention documented in FSAR Chapter 19 and in the supporting documents Analysis of In-Vessel Retention in the Reactor Pressure Vessel, ER-P020-3635-R0, and Analysis of In-Vessel Retention in the Containment Vessel, ER-P020-4450-R0. The applicant is requested to include the following additional information in FSAR Chapter 19. For the staff to make a finding that the applicant has performed an adequate evaluation of the risk from severe accidents in accordance with SRP 19.0, the applicant is requested to respond to the questions below.
NuScale Nonproprietary
In-vessel Retention in the reactor pressure vessel (RPV) a) The applicant used the critical heat fluxes measured in the Subscale Boundary Layer Boiling (SBLB) experiments to show that its predicted heat fluxes on the curved surfaces of the NuScale reactor vessel bottom head would not lead to failure. The geometry of the NuScale bottom head and surrounding containment is different from that of the SBSB experiments. For example, the bottom head has an integral seismic retention pin, and the SBLB experiments did not. The local critical heat flux depends on flow patterns (e.g., instabilities and recirculation can occur at junctions such as the where the seismic retention pin is joined to the hemispherical surface of the bottom head). In addition, the staff notes that different AP1000 reactor vessel bottom head and insulation configurations resulted in different experimentally measured critical heat fluxes in the AP1000 experimental program. The applicant is requested to provide justification for the use of the SBLB experimentally determined critical heat fluxes for the NuScale RPV bottom head.
b) The applicant performed ANSYS calculations assuming core debris relocated into the RPV lower plenum to estimate a heat flux of 330 kW/m2 at the junction of the hemispherical bottom head and the seismic retention pin. The applicant compared this to a critical heat flux of 400 kW/m2 from the SBLB experiments to demonstrate the robustness of its design to severe accident challenges and to assign an RPV lower head failure probability of zero in the Level 2 Containment Event Tree. This 20% difference between the estimated heat flux and the critical heat flux does not appear to be sufficiently large to conclude that RPV lower head failure probability is zero and in-vessel retention is certain even assuming that the SBLB experiments are representative of NuScale. Specifically, the applicant is requested to address the uncertainties in the analysis including the uncertainty in the assumed critical heat flux and uncertainties in the applicants ANSYS prediction of the heat flux. Uncertainties could include the time of relocation into the lower plenum, amount of material relocating, and the amount of heat generation within the postulated metallic layer over the corium. The relocation time and amount of material relocating can affect the analysis of in-vessel retention through the decay power and the height of the debris bed and can vary based on scenario and phenomenological assumptions.
In-vessel retention in the containment vessel (CNV) c) The applicant concluded that in-vessel retention in the CNV is certain because in-vessel retention in the RPV is certain and the CNV configuration is more favorable to cooling due to the presence of water in the CNV and because the same debris mass in the CNV has a greater surface area and a thinner body with a resulting lower heat flux. The applicant is requested to NuScale Nonproprietary
address the uncertainty in the critical heat flux for the CNV bottom head, considering that (1) the SBLB test geometry was hemispherical and the CNV bottom head is not; and (2) the CVN bottom head has a skirt and is 5 inches above the pool floor.
d) The applicants analysis did not include a case in which local heat fluxes could be increased by the focusing effect of a metallic layer overlying core debris. The applicant believes a molten metal layer on top of an oxidic melt is unrealistic in the containment lower plenum because of the presence of water there. However, conditions leading to a focusing effect could occur if failure of the reactor vessel lower head involves relocation of metals into the CNV lower plenum.
The applicant is requested to justify its belief that water prevents conditions leading to a focusing effect in the CNV lower plenum.
e) The applicant states that to allow flow between the skirted region and the region outside the skirt, there are ((2(a),(c) large (( ( }}2(a),(c) slots spaced evenly about the vessel just below the point where the skirt and the dome meet and (( }}2(a),(c) smaller ((
}}2(a),(c) slots evenly spaced about the vessel just above the bottom of the skirt. The applicant performed an analysis to show that the steam generated under the skirt by core debris in the containment lower plenum can effectively escape through the top holes preventing conditions from reaching local dry-out and failure of the containment dome. The applicant is requested to consider and evaluate the potential of the complex geometry of the skirted region (which is heated from above) to cause complex flow patterns (e.g., a countercurrent flow of steam and water developing in the top slots) that could prevent sufficient steam from escaping.
NuScale Response:
As a result of public discussions held with the NRC on November 13, 2018, January 8, 2019, and January 29, 2019, NuScale is supplementing its response to RAI 9043 (Question 19-26) which was originally provided in letter RAIO-1017-56516, dated October 10, 2017. In those discussions, NuScale agreed to modify the FSAR by replacing the term physically unrealistic and similar terminology to more directly reflect insights from NuScale phenomenological analyses and to clarify the presence of analysis uncertainty. Other information provided in the original RAI response remains valid.
NuScale Nonproprietary
Impact on DCA:
FSAR Section 19.2 has been revised as described in the response above and as shown in the markup provided with the supplemental response to RAI No. 9108 in NuScale letter RAIO-0219-64684.
NuScale Nonproprietary
RAIO-0219-64685 :
Affidavit of Zackary W. Rad, AF-0219-64686 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
NuScale Power, LLC AFFIDAVIT of Zackary W. Rad I, Zackary W. Rad, state as follows:
- 1. I am the Director, Regulatory Affairs of NuScale Power, LLC (NuScale), and as such, I have been specifically delegated the function of reviewing the information described in this Affidavit that NuScale seeks to have withheld from public disclosure, and am authorized to apply for its withholding on behalf of NuScale.
- 2. I am knowledgeable of the criteria and procedures used by NuScale in designating information as a trade secret, privileged, or as confidential commercial or financial information. This request to withhold information from public disclosure is driven by one or more of the following:
- a. The information requested to be withheld reveals distinguishing aspects of a process (or component, structure, tool, method, etc.) whose use by NuScale competitors, without a license from NuScale, would constitute a competitive economic disadvantage to NuScale.
- b. The information requested to be withheld consists of supporting data, including test data, relative to a process (or component, structure, tool, method, etc.), and the application of the data secures a competitive economic advantage, as described more fully in paragraph 3 of this Affidavit.
- c. Use by a competitor of the information requested to be withheld would reduce the competitor's expenditure of resources, or improve its competitive position, in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.
- d. The information requested to be withheld reveals cost or price information, production capabilities, budget levels, or commercial strategies of NuScale.
- e. The information requested to be withheld consists of patentable ideas.
- 3. Public disclosure of the information sought to be withheld is likely to cause substantial harm to NuScale's competitive position and foreclose or reduce the availability of profit-making opportunities. The accompanying Request for Additional Information response reveals distinguishing aspects about the method by which NuScale develops its specific NuScale design values.
NuScale has performed significant research and evaluation to develop a basis for this method and has invested significant resources, including the expenditure of a considerable sum of money.
The precise financial value of the information is difficult to quantify, but it is a key element of the design basis for a NuScale plant and, therefore, has substantial value to NuScale.
If the information were disclosed to the public, NuScale's competitors would have access to the information without purchasing the right to use it or having been required to undertake a similar expenditure of resources. Such disclosure would constitute a misappropriation of NuScale's intellectual property, and would deprive NuScale of the opportunity to exercise its competitive advantage to seek an adequate return on its investment.
AF-0219-64686
- 4. The information sought to be withheld is in the enclosed response to NRC Request for Additional Information No. 161, eRAI No. 9043. The enclosure contains the designation "Proprietary" at the top of each page containing proprietary information. The information considered by NuScale to be proprietary is identified within double braces, "(( }}" in the document.
- 5. The basis for proposing that the information be withheld is that NuScale treats the information as a trade secret, privileged, or as confidential commercial or financial information. NuScale relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC § 552(b)(4), as well as exemptions applicable to the NRC under 10 CFR §§ 2.390(a)(4) and 9.17(a)(4).
- 6. Pursuant to the provisions set forth in 10 CFR § 2.390(b)(4), the following is provided for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld:
- a. The information sought to be withheld is owned and has been held in confidence by NuScale.
- b. The information is of a sort customarily held in confidence by NuScale and, to the best of my knowledge and belief, consistently has been held in confidence by NuScale.
The procedure for approval of external release of such information typically requires review by the staff manager, project manager, chief technology officer or other equivalent authority, or the manager of the cognizant marketing function (or his delegate), for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside NuScale are limited to regulatory bodies, customers and potential customers and their agents, suppliers, licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or contractual agreements to maintain confidentiality.
- c. The information is being transmitted to and received by the NRC in confidence.
- d. No public disclosure of the information has been made, and it is not available in public sources. All disclosures to third parties, including any required transmittals to NRC, have been made, or must be made, pursuant to regulatory provisions or contractual agreements that provide for maintenance of the information in confidence.
- e. Public disclosure of the information is likely to cause substantial harm to the competitive position of NuScale, taking into account the value of the information to NuScale, the amount of effort and money expended by NuScale in developing the information, and the difficulty others would have in acquiring or duplicating the information. The information sought to be withheld is part of NuScale's technology that provides NuScale with a competitive advantage over other firms in the industry.
NuScale has invested significant human and financial capital in developing this technology and NuScale believes it would be difficult for others to duplicate the technology without access to the information sought to be withheld.
I declare under penalty of perjury that the foregoing is true and correct. Executed on February 26, 2019.
Zackary W. Rad AF-0219-64686}}