Category:Inspections
MONTHYEARML23214A2212023-07-30030 July 2023 Historical Vogtle Unit 3 Combined License Appendix C as of July 30 2023 ND-23-0205, Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests2023-07-28028 July 2023 Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests ND-22-0796, ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813) ND-23-0607, ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13) ND-23-0608, ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72) ND-23-0618, Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797)2023-07-20020 July 2023 Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797) ND-23-0162, ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165) ND-23-0459, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587) ND-23-0483, ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4) ND-23-0552, Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624)2023-07-18018 July 2023 Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624) ND-23-0575, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588) ND-23-0610, ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603)2023-07-17017 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603) ND-23-0586, ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159)2023-07-17017 July 2023 ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159) ML23199A1352023-07-17017 July 2023 ITAAC Closure Verification Evaluation Form (Vef) 2.7.05.02.i for ITAAC Number for Combined License ND-23-0406, ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498) ND-23-0573, ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497) ND-23-0476, ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355) ND-23-0499, ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700) ND-23-0606, ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557) ND-23-0601, ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719) ND-23-0594, ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629) ND-23-0446, ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250) ND-23-0603, ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831) ND-22-0816, ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19)2023-07-15015 July 2023 ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19) ND-23-0002, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270) ND-23-0597, ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530) ND-23-0122, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668) ND-23-0121, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667) ND-23-0588, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78) ML23195A0312023-07-14014 July 2023 ITAAC Closure Verification Evaluation Form (Vef) for ITAAC Number 2.1.03.06.i (Index No. 75) for Vogtle Unit 4 Combined License (VOG4) ND-23-0394, ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703) ND-23-0543, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622) ND-23-0461, ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652) ND-23-0587, ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595) ND-22-0980, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75) ND-23-0111, ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646) ND-23-0581, ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220) ND-23-0589, ITAAC Closure Notification on Completion of ITAAC 2.6.03.04a (Index Number 601)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.03.04a (Index Number 601) ND-23-0592, ITAAC Closure Notification on Completion of 2.7.06.03.i (Index Number 726)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of 2.7.06.03.i (Index Number 726) ML23194A0192023-07-12012 July 2023 Urgent: Vef (Icn 5033) ND-23-0486, ITAAC Closure Notification on Completion of ITAAC 2.2.01.11a.iv (Index Number 117)2023-07-11011 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.11a.iv (Index Number 117) ND-23-0183, ITAAC Closure Notification on Completion of ITAAC Item 2.3.11.03b (Index Number 454)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.3.11.03b (Index Number 454) ND-23-0582, ITAAC Closure Notification on Completion of ITAAC 2.3.29.04 (Index Number 491)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.29.04 (Index Number 491) ND-23-0164, ITAAC Closure Notification on Completion of Item 2.6.03.02.i (Index Number 597)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of Item 2.6.03.02.i (Index Number 597) ND-23-0443, ITAAC Closure Notification on Completion of ITAAC 2.3.10.07a.ii (Index Number 444)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.10.07a.ii (Index Number 444) ND-23-0490, ITAAC Closure Notification on Completion of ITAAC 3.3.00.05c (Index Number 786)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 3.3.00.05c (Index Number 786) ND-23-0578, ITAAC Closure Notification on Completion of ITAAC 2.5.01.02a (Index Number 506)2023-07-0707 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.01.02a (Index Number 506) ND-23-0163, ITAAC Closure Notification on Completion of ITAAC 2.2.01.05.i (Index Number 98)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.05.i (Index Number 98) ND-23-0577, ITAAC Closure Notification on Completion of ITAAC 2.2.03.11c.i (Index Number 212)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.03.11c.i (Index Number 212) ND-23-0576, ITAAC Closure Notification on Completion of ITAAC 2.2.01.10c (Index Number 113)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.10c (Index Number 113) 2023-07-08
[Table view] Category:Tests
MONTHYEARML23214A2212023-07-30030 July 2023 Historical Vogtle Unit 3 Combined License Appendix C as of July 30 2023 ND-23-0205, Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests2023-07-28028 July 2023 Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests ND-22-0796, ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813) ND-23-0607, ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13) ND-23-0608, ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72) ND-23-0618, Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797)2023-07-20020 July 2023 Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797) ND-23-0162, ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165) ND-23-0459, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587) ND-23-0483, ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4) ND-23-0552, Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624)2023-07-18018 July 2023 Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624) ND-23-0575, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588) ND-23-0610, ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603)2023-07-17017 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603) ND-23-0586, ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159)2023-07-17017 July 2023 ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159) ML23199A1352023-07-17017 July 2023 ITAAC Closure Verification Evaluation Form (Vef) 2.7.05.02.i for ITAAC Number for Combined License ND-23-0406, ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498) ND-23-0573, ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497) ND-23-0476, ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355) ND-23-0499, ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700) ND-23-0606, ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557) ND-23-0601, ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719) ND-23-0594, ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629) ND-23-0446, ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250) ND-23-0603, ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831) ND-22-0816, ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19)2023-07-15015 July 2023 ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19) ND-23-0002, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270) ND-23-0597, ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530) ND-23-0122, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668) ND-23-0121, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667) ND-23-0588, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78) ML23195A0312023-07-14014 July 2023 ITAAC Closure Verification Evaluation Form (Vef) for ITAAC Number 2.1.03.06.i (Index No. 75) for Vogtle Unit 4 Combined License (VOG4) ND-23-0394, ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703) ND-23-0543, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622) ND-23-0461, ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652) ND-23-0587, ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595) ND-22-0980, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75) ND-23-0111, ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646) ND-23-0581, ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220) ND-23-0589, ITAAC Closure Notification on Completion of ITAAC 2.6.03.04a (Index Number 601)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.03.04a (Index Number 601) ND-23-0592, ITAAC Closure Notification on Completion of 2.7.06.03.i (Index Number 726)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of 2.7.06.03.i (Index Number 726) ML23194A0192023-07-12012 July 2023 Urgent: Vef (Icn 5033) ND-23-0486, ITAAC Closure Notification on Completion of ITAAC 2.2.01.11a.iv (Index Number 117)2023-07-11011 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.11a.iv (Index Number 117) ND-23-0183, ITAAC Closure Notification on Completion of ITAAC Item 2.3.11.03b (Index Number 454)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.3.11.03b (Index Number 454) ND-23-0582, ITAAC Closure Notification on Completion of ITAAC 2.3.29.04 (Index Number 491)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.29.04 (Index Number 491) ND-23-0164, ITAAC Closure Notification on Completion of Item 2.6.03.02.i (Index Number 597)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of Item 2.6.03.02.i (Index Number 597) ND-23-0443, ITAAC Closure Notification on Completion of ITAAC 2.3.10.07a.ii (Index Number 444)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.10.07a.ii (Index Number 444) ND-23-0490, ITAAC Closure Notification on Completion of ITAAC 3.3.00.05c (Index Number 786)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 3.3.00.05c (Index Number 786) ND-23-0578, ITAAC Closure Notification on Completion of ITAAC 2.5.01.02a (Index Number 506)2023-07-0707 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.01.02a (Index Number 506) ND-23-0163, ITAAC Closure Notification on Completion of ITAAC 2.2.01.05.i (Index Number 98)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.05.i (Index Number 98) ND-23-0577, ITAAC Closure Notification on Completion of ITAAC 2.2.03.11c.i (Index Number 212)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.03.11c.i (Index Number 212) ND-23-0576, ITAAC Closure Notification on Completion of ITAAC 2.2.01.10c (Index Number 113)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.10c (Index Number 113) 2023-07-08
[Table view] Category:Analyses
MONTHYEARML23214A2212023-07-30030 July 2023 Historical Vogtle Unit 3 Combined License Appendix C as of July 30 2023 ND-23-0205, Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests2023-07-28028 July 2023 Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests ND-22-0796, ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813) ND-23-0607, ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13) ND-23-0608, ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72) ND-23-0618, Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797)2023-07-20020 July 2023 Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797) ND-23-0162, ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165) ND-23-0459, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587) ND-23-0483, ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4) ND-23-0552, Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624)2023-07-18018 July 2023 Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624) ND-23-0575, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588) ND-23-0610, ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603)2023-07-17017 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603) ND-23-0586, ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159)2023-07-17017 July 2023 ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159) ML23199A1352023-07-17017 July 2023 ITAAC Closure Verification Evaluation Form (Vef) 2.7.05.02.i for ITAAC Number for Combined License ND-23-0406, ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498) ND-23-0573, ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497) ND-23-0476, ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355) ND-23-0499, ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700) ND-23-0606, ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557) ND-23-0601, ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719) ND-23-0594, ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629) ND-23-0446, ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250) ND-23-0603, ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831) ND-22-0816, ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19)2023-07-15015 July 2023 ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19) ND-23-0002, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270) ND-23-0597, ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530) ND-23-0122, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668) ND-23-0121, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667) ND-23-0588, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78) ML23195A0312023-07-14014 July 2023 ITAAC Closure Verification Evaluation Form (Vef) for ITAAC Number 2.1.03.06.i (Index No. 75) for Vogtle Unit 4 Combined License (VOG4) ND-23-0394, ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703) ND-23-0543, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622) ND-23-0461, ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652) ND-23-0587, ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595) ND-22-0980, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75) ND-23-0111, ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646) ND-23-0581, ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220) ND-23-0589, ITAAC Closure Notification on Completion of ITAAC 2.6.03.04a (Index Number 601)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.03.04a (Index Number 601) ND-23-0592, ITAAC Closure Notification on Completion of 2.7.06.03.i (Index Number 726)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of 2.7.06.03.i (Index Number 726) ML23194A0192023-07-12012 July 2023 Urgent: Vef (Icn 5033) ND-23-0486, ITAAC Closure Notification on Completion of ITAAC 2.2.01.11a.iv (Index Number 117)2023-07-11011 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.11a.iv (Index Number 117) ND-23-0183, ITAAC Closure Notification on Completion of ITAAC Item 2.3.11.03b (Index Number 454)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.3.11.03b (Index Number 454) ND-23-0582, ITAAC Closure Notification on Completion of ITAAC 2.3.29.04 (Index Number 491)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.29.04 (Index Number 491) ND-23-0164, ITAAC Closure Notification on Completion of Item 2.6.03.02.i (Index Number 597)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of Item 2.6.03.02.i (Index Number 597) ND-23-0443, ITAAC Closure Notification on Completion of ITAAC 2.3.10.07a.ii (Index Number 444)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.10.07a.ii (Index Number 444) ND-23-0490, ITAAC Closure Notification on Completion of ITAAC 3.3.00.05c (Index Number 786)2023-07-0808 July 2023 ITAAC Closure Notification on Completion of ITAAC 3.3.00.05c (Index Number 786) ND-23-0578, ITAAC Closure Notification on Completion of ITAAC 2.5.01.02a (Index Number 506)2023-07-0707 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.01.02a (Index Number 506) ND-23-0163, ITAAC Closure Notification on Completion of ITAAC 2.2.01.05.i (Index Number 98)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.05.i (Index Number 98) ND-23-0577, ITAAC Closure Notification on Completion of ITAAC 2.2.03.11c.i (Index Number 212)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.03.11c.i (Index Number 212) ND-23-0576, ITAAC Closure Notification on Completion of ITAAC 2.2.01.10c (Index Number 113)2023-07-0606 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.01.10c (Index Number 113) 2023-07-08
[Table view] Category:and Acceptance Criteria (ITAAC)
MONTHYEARML23214A2212023-07-30030 July 2023 Historical Vogtle Unit 3 Combined License Appendix C as of July 30 2023 ML23195A0312023-07-14014 July 2023 ITAAC Closure Verification Evaluation Form (Vef) for ITAAC Number 2.1.03.06.i (Index No. 75) for Vogtle Unit 4 Combined License (VOG4) ML22178A0902022-06-27027 June 2022 ITAAC Review Status Report 6-27-2022 ML22167A0222022-06-16016 June 2022 ITAAC Review Status Report 6-16-2022 ML22165A0752022-06-14014 June 2022 ITAAC Review Status Report 6-14-2022 ML22165A0762022-06-14014 June 2022 ITAAC Review Status Report 6-14-2022 ML22116A0362022-04-26026 April 2022 ITAAC Review Status Report 4-26-2022 ML22026A0562022-01-26026 January 2022 ITAAC Review Status Report 1-26-2022 ND-22-0041, Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load2022-01-18018 January 2022 Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load ML21336A5752021-12-0909 December 2021 Update to Targeted Inspections, Tests, Analyses, and Acceptance Criteria for Vogtle Electric Generating Plant Units 3 and 4 ML21342A3042021-11-0202 November 2021 Attachment 1 - Vogtle Units 3 & 4 ITAAC - November 2021 ML21342A3052021-11-0202 November 2021 Attachment 2 - Vogtle Units 3 and 4 ITAAC - November 2021 ND-21-0916, Resubmittal of ITAAC Closure Notification on Completion of 2.5.05.03b (Index Number 570)2021-10-20020 October 2021 Resubmittal of ITAAC Closure Notification on Completion of 2.5.05.03b (Index Number 570) ND-21-0610, Resubmittal of Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 3.3.00.02a.ii.e (Index Number 768)2021-07-0101 July 2021 Resubmittal of Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 3.3.00.02a.ii.e (Index Number 768) ML21123A0352021-05-0303 May 2021 ITAAC Review Status Report 5-3-2021 ND-21-0241, Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.2.03.08c.iv.01 (Index Number 183)2021-03-15015 March 2021 Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.2.03.08c.iv.01 (Index Number 183) ND-21-0242, Notice of Uncompleted ITAAC 225-clavs Prior to Initial Fuel Load Item 2.2.03.08c.iv.03 (Index Number 185)2021-03-15015 March 2021 Notice of Uncompleted ITAAC 225-clavs Prior to Initial Fuel Load Item 2.2.03.08c.iv.03 (Index Number 185) ND-21-0155, Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.2.03.08c.iv.02 (Index Number 184)2021-03-11011 March 2021 Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.2.03.08c.iv.02 (Index Number 184) ND-21-0143, Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.2.03.08c.iii (Index Number 182)2021-03-0909 March 2021 Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.2.03.08c.iii (Index Number 182) ND-20-1108, Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.3.03.02 (Index Number 319)2021-03-0909 March 2021 Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.3.03.02 (Index Number 319) ML21061A2162021-03-0303 March 2021 Annual Assessment Letter for Vogtle Electric Generating Plant Units 3 & 4, NRC Report 05200025/2020006 and 05200026/2020006 ML21032A2602021-02-0101 February 2021 ITAAC Status Report 2-1-2021 ML21032A2652021-02-0101 February 2021 ITAAC Status Report 2-1-2021 ML21004A1102021-01-0404 January 2021 ITAAC Status Report 1-4-2021 ML21277A0512020-11-0404 November 2020 Archives, Closed in Report (NCV) ND-20-1246, Supplement for API 000 ITAAC 2.3.05.03a.ii (Index Number 344) Completion2020-10-27027 October 2020 Supplement for API 000 ITAAC 2.3.05.03a.ii (Index Number 344) Completion ML20281A3832020-10-0101 October 2020 ITAAC Status Report 10-1-2020 ML20281A3952020-10-0101 October 2020 ITAAC Status Report 10-1-2020 ML20006D8082020-03-10010 March 2020 Appendix C (Amendment No. 167) - Page C-428 Corrected ML20006D8222020-03-10010 March 2020 Appendix C (Amendment No. 165) - Page C-428 Corrected ND-20-0002, Construction Activities Schedule Six-Month Update for Completion of the Inspections, Tests, and Analyses (ITA)2020-01-28028 January 2020 Construction Activities Schedule Six-Month Update for Completion of the Inspections, Tests, and Analyses (ITA) ND-20-0023, Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 3.3.00.02f (Index Number 774)2020-01-21021 January 2020 Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 3.3.00.02f (Index Number 774) ND-19-1538, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.09d (Index Number 548)2020-01-0202 January 2020 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.09d (Index Number 548) ND-19-1571, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.04.02.1 (Index Number 557)2020-01-0202 January 2020 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.04.02.1 (Index Number 557) ND-19-1536, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.08b.ii (Index Number 543)2020-01-0202 January 2020 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.08b.ii (Index Number 543) ND-19-1537, Unit 4 - Resubmittal of Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.1.02.1la.ii (Index Number 47)2019-12-19019 December 2019 Unit 4 - Resubmittal of Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.1.02.1la.ii (Index Number 47) ND-19-1523, Unit 4 - Resubmittal of Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.06a.ii (Index Number 530)2019-12-19019 December 2019 Unit 4 - Resubmittal of Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.06a.ii (Index Number 530) ND-19-1460, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.1.02.09a (Index Number 41)2019-12-0202 December 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.1.02.09a (Index Number 41) ND-19-1263, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.6.01.04e (Index Number 588)2019-11-25025 November 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.6.01.04e (Index Number 588) ND-19-1348, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 3.3.00.02a.i.a (Index Number 760)2019-11-22022 November 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 3.3.00.02a.i.a (Index Number 760) ND-19-1349, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 3.3.00.02a.i.b (Index Number 761)2019-11-22022 November 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 3.3.00.02a.i.b (Index Number 761) ND-19-1351, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 3.3.00.02a.i.d (Index Number 763)2019-11-22022 November 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 3.3.00.02a.i.d (Index Number 763) ND-19-1353, Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.3.02.14 (Index Number 317)2019-11-0606 November 2019 Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.3.02.14 (Index Number 317) ND-19-1309, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.2.02.07a.iii (Index Number 137)2019-10-31031 October 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.2.02.07a.iii (Index Number 137) ND-19-1333, Unit 4 - Resubmittal of Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.1.03.06.i (Index Number 75)2019-10-31031 October 2019 Unit 4 - Resubmittal of Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.1.03.06.i (Index Number 75) ND-19-1323, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.06a.ii (Index Number 530)2019-10-31031 October 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.06a.ii (Index Number 530) ND-19-0920, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.7.04.03 (Index Number 716)2019-10-29029 October 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.7.04.03 (Index Number 716) ND-19-1324, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.7.06.03.1 (Index Number 726)2019-10-29029 October 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.7.06.03.1 (Index Number 726) ND-19-1330, Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.3.29.02 (Index Number 489)2019-10-29029 October 2019 Unit 4 - Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.3.29.02 (Index Number 489) ND-19-1311, Unit 4 - Resubmittal Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.10 (Index Number 549)2019-10-28028 October 2019 Unit 4 - Resubmittal Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.02.10 (Index Number 549) 2023-07-30
[Table view] Category:Letter type:ND
MONTHYEARND-24-0103, Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests2024-04-26026 April 2024 Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests ND-24-0114, Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2024-04-0101 April 2024 Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-24-0059, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2024-03-0404 March 2024 Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0693, Combined License (COL) License Condition 2.D.(4)(d) Completion of Initial Criticality and Low-Power Tests2024-02-15015 February 2024 Combined License (COL) License Condition 2.D.(4)(d) Completion of Initial Criticality and Low-Power Tests ND-23-0690, Combined License (COL) License Condition 2.D.(3)(e) Completion of Pre-Critical Tests2024-02-0808 February 2024 Combined License (COL) License Condition 2.D.(3)(e) Completion of Pre-Critical Tests ND-24-0019, Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2024-02-0101 February 2024 Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0912, Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2024-01-0202 January 2024 Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0881, Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-12-0404 December 2023 Submittal of Vogtle Electric Generating Plant (Vegp), Unit 4, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0817, Report of UFSAR Chapter 14 Changes to the Initial Test Program in Accordance with License Condition 2.D.(7)(a)2023-11-17017 November 2023 Report of UFSAR Chapter 14 Changes to the Initial Test Program in Accordance with License Condition 2.D.(7)(a) ND-23-0823, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-11-0303 November 2023 Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0723, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-10-0404 October 2023 Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0697, Submittal of Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-09-0505 September 2023 Submittal of Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0669, Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule2023-08-0707 August 2023 Combined License (COL) Operational Programs and Other License Conditions Implementation Schedule ND-23-0205, Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests2023-07-28028 July 2023 Combined License (COL) License Condition 2.D.(5)(d) Completion of Power Ascension Tests ND-23-0618, Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797)2023-07-20020 July 2023 Resubmittal of ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.07c.ii.a (Index Number 797) ND-23-0609, Notification of Completion of All ITAAC2023-07-20020 July 2023 Notification of Completion of All ITAAC ND-23-0608, ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.03.03 (Index Number 72) ND-23-0607, ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.02.02a (Index Number 13) ND-22-0796, ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813)2023-07-20020 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.3.00.08 (Index Number 813) ND-23-0459, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04d (Index Number 587) ND-23-0162, ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165)2023-07-19019 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.03.05a.i (Index Number 165) ND-23-0575, ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.01.04e (Index Number 588) ND-23-0439, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07a.i (Index Number 265)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.05.07a.i (Index Number 265) ND-23-0552, Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624)2023-07-18018 July 2023 Southern Nuclear Operating Company, Vogtle Electric Generating Plant, Unit 4, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02c (Index Number 624) ND-23-0483, ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4)2023-07-18018 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.1.01.04 (Index Number 4) ND-23-0586, ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159)2023-07-17017 July 2023 ITAAC Closure Notice on Completion of ITAAC 2.2.03.02a (Index Number 159) ND-23-0610, ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603)2023-07-17017 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.03.04c (Index Number 603) ND-23-0573, ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of 2.4.02.02a (Index Number 497) ND-23-0406, ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498)2023-07-16016 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.4.02.02b (Index Number 498) ND-23-0601, ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.7.05.02.i (Index Number 719) ND-22-0816, ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19)2023-07-15015 July 2023 ITAAC Closure Notification of Completion of ITAAC 2.1.02.05a (Index Number 19) ND-23-0603, ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 3.5.00.06 (Index Number 831) ND-23-0446, ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.12a.iii (Index Number 250) ND-23-0594, ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.05.02.ii (Index Number 629) ND-23-0606, ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.04.02.i (Index Number 557) ND-23-0499, ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.01.14 (Index Number 700) ND-23-0476, ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355)2023-07-15015 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.3.06.02a (Index Number 355) ND-23-0121, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.07 (Index Number 667) ND-23-0122, ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC C.2.6.09.08a (Index Number 668) ND-23-0588, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.07.i (Index Number 78) ND-23-0597, ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.5.02.06a.ii (Index Number 530) ND-23-0002, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270)2023-07-14014 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.05.07c (Index Number 270) ND-23-0543, ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.6.04.02a (Index Number 622) ND-23-0394, ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.7.02.03a (Index Number 703) ND-23-0461, ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.13a (Index Number 652) ND-22-0980, ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC Item 2.1.03.06.i (Index Number 75) ND-23-0587, ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.02.02c (Index Number 595) ND-23-0111, ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646)2023-07-13013 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.09.05c (Index Number 646) ND-23-0581, ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.2.04.02a (Index Number 220) ND-23-0589, ITAAC Closure Notification on Completion of ITAAC 2.6.03.04a (Index Number 601)2023-07-12012 July 2023 ITAAC Closure Notification on Completion of ITAAC 2.6.03.04a (Index Number 601) 2024-04-26
[Table view] |
Text
i. Southern Nuclear FEB t 1 2019 Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4 7825 River Road Waynesboro, GA 30830 706-848-6459 tel 410-474-8587 cell myox @
southernco.com Docket Nos.:
52-025 52-026 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 ND-19-0077 10CFR 52.99(c)(3)
Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 and Unit 4 Notice of Uncompleted ITAAC 225-davs Prior to Initial Fuel Load Item 2.3.02.08a.i [Index Number 3011 Ladies and Gentlemen:
Pursuant to 10 CFR 52.99(c)(3), Southern Nuclear Operating Company hereby notifies the NRC that as of February 1, 2019, Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Uncompleted Inspections Tests Analyses and Acceptance Criteria (ITAAC) Item 2.3.02.08a.i
[Index Number 301] has not been completed greater than 225-days prior to initial fuel load. The Enclosure describes the plan for completing ITAAC 2.3.02.08a.i [Index Number 301]. Southern Nuclear Operating Company will, at a later date, provide additional notifications for ITAAC that have not been completed 225-days prior to initial fuel load.
This notification is informed by the guidance described in NEI-08-01, Industry Guideline for the ITAAC Closure Process Under 10 CFR Part 52, which was endorsed by the NRC in Regulatory Guide 1.215. In accordance with NEI 08-01, this notification includes ITAAC for which required inspections, tests, or analyses have not been performed or have been only partially completed.
All ITAAC will be fully completed and all Section 52.99(c)(3) ITAAC Closure Notifications will be submitted to NRC to support the Commission finding that all acceptance criteria are met prior to plant operation, as required by 10 CFR 52.103(g).
This letter contains no new NRC regulatory commitments.
If there are any questions, please contact Tom Petrak at 706-848-1575.
U.S. Nuclear Regulatory Commission ND-19-0077 Page 2 of 4 Respectfully submitted, Michael J. Yox Regulatory Affairs Dfrector Vogtle 3 & 4
Enclosure:
Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.3.02.08a.i [Index Number 301]
MJY/DLW/sfr
U.S. Nuclear Regulatory Commission ND-19-0077 Page 3 of 4 To:
Southern Nuclear Operating Company/ Georgia Power Company Mr. D. A. Bost (w/o enclosures)
Mr. D. L. McKlnney (w/o enclosures)
Mr. M. D. Meier (w/o enclosures)
Mr. D. H. Jones (w/o enclosures)
Mr. J. B. Klecha Mr. G. Chick Mr. M. J. Yox Mr. A. 8. Ration Ms. K. A. Roberts Mr. T. G. Petrak Mr. W. A. Sparkman Mr. C. T. Defnall Mr. C. E. Morrow Mr. J. L. Hughes Ms. K. M. Stacy Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE; VND.LI.L06 File AR.01.02.06 cc:
Nuclear Reouiatorv Commission Mr. W. Jones (w/o enclosures)
Mr. F. D. Brown Ms. J. M. Heisserer Mr. C. P. Patel Mr. G. J. Khourl Ms. S. E. Temple Mr. N. D. Karlovich Mr. A. Lerch Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert Mr. C. Welch Mr. I. Cozens Mr. J. Gaslevic Mr. V. Hall Qqiethoroe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municlpai Eiectric Authoritv of Georgia Mr. J. E. Fuller Mr. S. M. Jackson
U.S. Nuclear Regulatory Commission ND-19-0077 Page 4 of 4 Dalton Utilities Mr. T. Bundros Westinqhouse Electric Company. LLC Dr. L. OrianI (w/o enclosures)
Mr. D. C. Durham (w/o enclosures)
Mr. M. M. Corletti Ms. L. G. Iller Ms. J. Monahan Mr. J. L. Coward Other Mr. J. E. Hosier, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.
Dr. W. R. Jacobs, Jr., Ph.D., CDS Associates, Inc.
Mr. 8. Roetger, Georgia Public Service Commission Ms. 8. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Balch Bingham
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 1 of 16 Southern Nuclear Operating Company ND-19-0077 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 and Unit 4 Completion Plan for Uncompleted ITAAC 2.3.02.08a.l [Index Number 301]
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 2 of 16 ITAAC Statement Design Commitment 8.a) The CVS provides makeup water to the RCS.
8.b) The CVS provides the pressurizer auxiliary spray.
- 9. Safety-related displays identified in Table 2.3.2-1 can be retrieved in the MCR.
10.a) Controls exist in the MCR to cause the remotely operated valves identified in Table 2.3.2-I to perform active functions.
lO.b) The valves identified in Table 2.3.2-1 as having RMS control perform an active safety function after receiving a signal from the RMS.
II.a) The motor-operated and check valves identified in Table 2.3.2-1 perform an active safety-related function to change position as indicated in the table.
11.b) After loss of motive power, the remotely operated valves identified in Table 2.3.2-1 assume the indicated loss of motive power position.
12.a) Controls exist in the MCR to cause the pumps identified in Table 2.3.2-3 to perform the listed function.
12.b) The pumps identified in Table 2.3.2-3 start after receiving a signal from the RLS.
- 13. Displays of the parameters identified in Table 2.3.2-3 can be retrieved in the MCR.
I nsoections/T ests/Analvses i) Testing will be performed by aligning a flow path from each CVS makeup pump, actuating makeup flow to the RCS at pressure greater than or equal to 2000 psia, and measuring the flow rate in the makeup pump discharge line with each pump suction aligned to the boric acid storage tank.
Testing will be performed by aligning a flow path from each CVS makeup pump to the pressurizer auxiliary spray and measuring the flow rate in the makeup pump discharge line with each pump suction aligned to the boric acid storage tank and with RCS pressure greater than or equal to 2000 psia.
Inspection will be performed for retrievability of the safety-related displays in the MCR.
Stroke testing will be performed on the remotely operated valves identified in Table 2.3.2-1 using the controls in the MCR.
i) Testing will be performed using real or simulated signals into the RMS.
ii) Testing will be performed to demonstrate that the remotely operated CVS isolation valves CVS-V090, V091, V136A/B close within the required response time.
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 3 of 16 iii) Tests of the motor-operated valves will be performed under pre-operational flow, differential pressure, and temperature conditions.
iv) Exercise testing of the check valves with active safety functions identified in Tabie 2.3.2-1 wiil be performed under pre-operationai test pressure, temperature and fluid flow conditions.
Testing of the remoteiy operated vaives will be performed under the conditions of ioss of motive power.
Testing will be performed to actuate the pumps identified in Table 2.3.2-3 using controis in the MGR.
Testing wiii be performed to confirm starting of the pumps identified in Table 2.3.2-3.
Inspection wili be performed for retrievability of the dispiays identified in Table 2.3.2-3 in the MGR.
Acceptance Criteria i) Each GVS makeup pump provides a fiow rate of greater than or equal to 100 gpm.
Each GVS makeup pump provides spray flow to the pressurizer.
Safety-related displays identified in Table 2.3.2-1 can be retrieved in the MGR.
Controls in the MGR operate to cause the remotely operated valves identified in Table 2.3.2-1 to perform active functions.
i) The vaives identified in Tabie 2.3.2-1 as having PMS control perform the active function identified in the tabie after receiving a signal from the PMS.
ii) These valves close within the following times after receipt of an actuation signal:
V090, V091 < 30 sec, V136A/B < 20 sec.
iii) Each motor-operated vaive changes position as indicated in Tabie 2.3.2-1 under pre-operational test conditions.
iv) Each check valve changes position as indicated in Tabie 2.3.2-1.
Upon loss of motive power, each remotely operated valve identified in Tabie 2.3.2-1 assumes the indicated loss of motive power position.
Controls in the MGR cause pumps identified in Table 2.3.2-3 to perform the listed function.
The pumps identified in Tabie 2.3.2-3 start after a signal is generated by the PLS.
Displays identified in Table 2.3.2-3 can be retrieved in the MGR.
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 4 of 16 ITAAC Completion Description Multiple ITAAC are performed to verify by inspections and tests that each of the Chemical and Volume Control System (CVS) makeup pumps provide a flow rate of greater than or equal to 100 gpm to the Reactor Coolant System (RCS) and provides spray flow to the pressurizer. This ITAAC also ensures safety-related displays identified in Combined License (COL) Table 2.3.2-1 can be retrieved in the Main Control Room (MCR), displays identified in COL Table 2.3.2-3 can be retrieved in the MCR, controls in the MCR operate to cause the remotely operated valves identified in COL Table 2.3.2-1 to perform active functions, controls in the MCR cause pumps identified in COL Table 2.3.2-3 to perform the listed function, and the pumps identified in COL Table 2.3.2-3 start after a signal is generated by the Plant Control System (PLS). Additionally, this ITAAC verifies the valves identified in COL Table 2.3.2-1 as having Protection and Safety Monitoring System (PMS) control perform the active function identified in the table after receiving a signal from the PMS, valves close within the following times after receipt of an actuation signal: V090, V091 < 30 sec; V136A, V136B < 20 sec, each motor-operated valve and check valve change positions as indicated in COL Table 2.3.2-1 under preoperational test conditions. Upon loss of motive power, each remotely operated valve identified in COL Table 2.3.2-1 assumes the loss of motive power position.
i) Each CVS makeup pumo provides a flow rate of Greater than or eoual to 100 com.
Testing is performed in accordance with Unit 3 and Unit 4 preoperational test procedures 3-CVS-ITPP-502 and 4-CVS-ITPP-502 (References 1 & 2) to confirm that with suction aligned to the boric acid storage tank, the Reactor Coolant System (RCS) at greater than or equal to 2000 psia and a flow path established to the RCS, that each CVS makeup pump provides greater than or equal to 100 gpm flow measured at the pump discharge.
With the RCS at 555°F - 559°F and 2220 psig -
2250 psig, the CVS system is aligned to perform a batch boron addition to the RCS. The A CVS makeup pump suction is aligned to the boric acid storage tank and a batch boron addition is initiated using the operating procedure.
The flow on the discharge of the CVS makeup pump is monitored and trended. This testing is repeated utilizing the B CVS makeup pump. The Unit 3 A CVS makeup pump flow is XXX gpm and the Unit 3 B CVS makeup pump flow is YYY gpm. The Unit 4 A CVS makeup pump flow is XXX gpm and the Unit 4 B CVS makeup pump flow is YYY gpm. This confirms that each CVS makeup pump provides a flow rate of greater than or equal to 100 gpm with the RCS at greater than or equal to 2000 psia.
Each CVS makeup pump provides sorav flow to the pressurizer.
Testing is performed in accordance with Unit 3 and Unit 4 preoperational test procedures 3-CVS-ITPP-502 and 4-CVS-ITPP-502 (References 1 & 2) to confirm that with suction aligned to the boric acid storage tank, the Reactor Coolant System (RCS) at greater than or equal to 2000 psia and a flow path established to the pressurizer auxiliary spray, that each CVS makeup pump provides spray flow to the pressurizer.
With the RCS at 555°F - 559°F degrees and 2220 psig -
2250 psig, the CVS system is aligned to perform an automatic blended makeup to the RCS. The makeup flow control valve is placed in manual and the A CVS makeup pump is started. The auxiliary spray valve is opened and the makeup flow control valve is throttled open until flow rate is equal to or greater than 100 gpm.
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 5 of 16 The discharge flow is monitored and trended. The B CVS makeup pump is started and the A GVS makeup pump is stopped. The makeup flow control valve is throttled to provide greater than or equal to 100 gpm at the pump discharge and the flow is monitored and trended. The Unit 3 A CVS makeup pump flow is XXX gpm and the Unit 3 B CVS makeup pump flow is YYY gpm. The Unit 4 A CVS makeup pump flow is XXX gpm and the Unit 4 B CVS makeup pump flow is YYY gpm. This demonstrates that each VCS makeup pump provides spray flow to the pressurizer with the PCS at greater than or equal to 2000 psia.
Safetv-related displavs identified in Table 2.3.2-1 can be retrieved in the MCR.
An inspection is performed in accordance with Unit 3 and Unit 4 component test procedures SV3-ITAAC-ST-2.3.02.08a.i, Item 09,10a, and lib and SV4-ITAAC-ST-2.3.02.08a.i, Item 09, 10a, and lib (References 3 & 4) to ensure the safety-related displays identified in Combined License (COL) Table 2.3.2-1 (Attachment A) can be retrieved in the MCR.
The valves listed in Attachment A as having safety-related displays for valve position are located on the MCR PMS Visual Display Units (VDUs) and verified to indicate on each of the VDUs. This confirms that safety-related displays identified in Attachment A can be retrieved in the Unit 3 and Unit 4 MCR.
Controls in the MCR operate to cause the remotelv operated valves identified in Table 2.3.2-1 to perform active functions.
Stroke testing is performed in accordance with Unit 3 and Unit 4 component test procedures SV3-ITAAC-ST-2.3.02.08a.i, Item 09,10a, and lib and SV4-ITAAC-ST-2.3.02.08a.i, Item 09, 10a, and lib (References 3 & 4) using controls in the MCR to confirm that the remotely operated valves identified in COL Table 2.3.2-1 (Attachment B) perform their active function.
The valves identified in Attachment B are stroke tested using an operator work station in the MCR. The valves are initially opened and are stroked closed using the Plant Control System (PLS) and verified locally to have gone closed. This demonstrates that controls in the Unit 3 and Unit 4 MCR operate to cause the remotely operated valves identified in Attachment B to perform active functions.
i) The valves identified in Table 2.3.2-1 as having PMS control perform the active function identified in the table after receiving a signal from the PMS.
Testing is performed in accordance with Unit 3 and Unit 4 preoperational test procedures 3-PMS-ITPP-504 and 4-PMS-ITPP-504 (References 5 &
6), 3-PMS-ITPP-523 and 4-PMS-ITPP-523 (References 7 & 8), and 3-PMS-ITPP-524 and 4-PMS-ITPP-524 (References 9 & 10) to demonstrate that the valves identified in COL Table 2.3.2-1 (Attachment C) as having PMS control perform the active function identified in the table after receiving a signal from the PMS.
Testing is performed in references 5 & 6 that positions valves CVS-PL-V136A, CVS-PL-V136B to the open position. A PMS PRHR Actuation signal is generated by opening the PRHR heat exchanger outlet flow control valve. This generates an automatic PRHR actuation from PMS.
The valves are verified to perform their active function to transfer closed.
Testing is performed in references 7 & 8 that positions valves CVS-PL-V045, CVS-PL-V047, CVS-PL-V092, CVS-PL-V094, and CVS-PL-V219 to the open position. A high-2 containment
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 6 of 16 pressure signal is generated by simulating a signal on the output terminals of the containment pressure instruments which generates a PMS safeguards signal and a containment Isolation signal. The valves are verified to perform their active function to transfer closed.
Testing is performed in references 9 & 10 that positions valves CVS-PL-V001, GVS-PL-V0002, CVS-PL-V003, CVS-PL-V084, CVS-PL-V090, and CVS-PL-V091 to the open position. A PMS CVS Makeup Isolation is initiated by manual actuation and valves CVS-PL-V001, CVS-PL-V0002, CVS-PL-V003 and CVS-PL-V084 are verified to perform their active function to transfer closed. A PMS Boron Dilution Block is initiated by simulating a source range flux doubling and valves CVS-PL-V090 and CVS-PL-V091 are verified to perform their active function to transfer closed.
The test results demonstrate that the valves identified in Attachment 0 for Unit 3 and Unit 4 as having PMS control perform the active function identified in the table after receiving a signal from the PMS.
W) These valves close within the followino times after receipt of an actuation signal:
V090. V091 < 30 sec. V136A/B < 20 sec.
Testing is performed in accordance with Unit 3 and Unit 4 preoperational test procedures 3-PMS-ITPP-504 and 4-PMS-ITPP-504 (References 5 & 6) and 3-PMS-ITPP-524 and 4-PMS-ITPP-524 (references 9 & 10) to demonstrate that the remotely operated CVS isolation valves CVS-V090, V091, V136A/B listed in Attachment D close within the following times after receipt of an actuation signal: V090, V091 < 30 sec, V136A/B < 20 sec.
Testing is performed in references 5 & 6 that positions valves CVS-PL-V136A, CVS-PL-V136B to the open position. A PMS PRHR Actuation signal is generated by opening the PRHR heat exchanger outlet flow control valve. This generates an automatic PRHR actuation from PMS.
The valves are timed using a PMS tabular trend and verified to meet the acceptance criteria.
The valve closure times are listed in Attachment D.
Testing is performed in references 9 & 10 that positions valves CVS-PL-V090 and CVS-PL-V091 to the open position. A source range flux doubling signal is generated by simulating a flux doubling signal PMS reactor trip and Boron Dilution Block signal. The valves are timed using a PMS tabular trend and verified to meet the acceptance criteria. The valve closure times are listed in Attachment D.
The test results demonstrate that the Unit 3 and Unit 4 valves close within the following times after receipt of an actuation signal: V090, V091 < 30 sec, V136A/B < 20 sec.
iih Each motor-operated valve changes position as indicated in Table 2.3.2-1 under pre operational test conditions.
Testing is performed in accordance with Unit 3 and Unit 4 preoperational test procedures 3-CVS-ITPP-502 and 4-CVS-ITPP-502 (References 1 & 2) to confirm the motor-operated valves listed in COL Appendix C Table 2.3.2-1 (Attachment E) change position under pre-operational flow, differential pressure, and temperature conditions.
Testing establishes the preoperational test conditions of RCS at atmospheric pressure and ensures the RCS makeup rate is greater than or equal to 135 gpm and less than or equal to 175
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 7 of 16 gpm which provides the greatest differentiai pressure for makeup line Motor-operated Valve (MOV) operation. CVS-PL-V090 is closed and verified to be closed locally and then reopened.
The preoperational test conditions are re-verified and CVS-PL-V091 is closed and verified to be closed locally.
Preoperational test conditions are established with the PCS at 555°F - 559°F degrees and 2220 psig -
2250 psig with purification in service at normai operating temperature and pressure.
CVS-PL-V001 is closed and verified to be ciosed locaiiy and then CVS-PL-V001 wiii be re opened. Preoperational test conditions are re-verified and CVS-PL-V002 is closed and verified to be closed locally, then CVS-PL-V002 will be opened. The preoperational test conditions are re-verified and CVS-PL-V003 is closed and verified to be closed locally.
The test results demonstrate that each motor-operated valve for Unit 3 and Unit 4 changes position as indicated in Attachment E under pre-operationai test conditions.
iv) Each check vaive chances position as indicated in Tabie 2.3.2-1.
Testing is performed in accordance with Unit 3 and Unit 4 preoperational test procedures 3-CVS-ITPP-502 and 4-CVS-ITPP-502 (References 1 & 2) to confirm that each check valve with an active safety function changes position as indicated in COL Table 2.3.2-1 (Attachment F) under pre-operational test pressure, temperature, and fluid flow conditions.
Preoperationai test conditions are established with the PCS at 555°F - 559°F degrees and 2220 psig -
2250 psig for the performance of the check valve testing that foiiows.
With preoperationai test conditions established and purification fiow established, CVS-PL-V001 is closed and check valves CVS-PL-V080, CVS-PL-V081, and CVS-PL-V082 are verified to close using non-intrusive valve disc position verification.
With preoperational test conditions estabiished and makeup and purification in service, CVS-PL-V081 is ciosed and CVS-PL-V067 is verified to be open by uitrasonic flow indication. CVS-PL-V081 is reopened and the uitrasonic flow indication (no flow) is used to demonstrate that CVS-PL-V067 is closed.
With preoperational test conditions established and makeup and purification in service, CVS-PL-V091 is closed and CVS-PL-V100 is verified to open by ultrasonic flow instrument indication.
CVS-PL-V091 is opened and CVS-PL-V100 is verified to ciose by flow indication (no flow).
With preoperational test conditions established, hydrogen addition is performed to the PCS which demonstrates the CVS-PL-217 is open. The hydrogen injection package is isolated, the hydrogen injection valve CVS-PL-219 is verified to be open and the hydrogen injection line is vented off upstream of CVS-PL-V217. The pressure upstream of CVS-PL-217 is verified to lower which demonstrates the check vaive has ciosed.
With preoperationai test conditions established, pressurizer auxiiiary spray is placed into service, the auxiliary spray air-operated valve is closed and CVS-PL-V085 is verified to close using non-intrusive valve disc position verification.
The test resuits demonstrate that each check valve for Unit 3 and Unit 4 changes position as indicated in Attachment F.
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 8 of 16 Upon loss of motive power, each remotely operated valve identified in Table 2.3.2-1 assumes the Indicated loss of motive power position.
Testing is performed in accordance with Unit 3 and Unit 4 component test procedures SV3-ITAAC-ST-2.3.02.08a.i, Item 09,10a, and lib and SV4-ITAAC-ST-2.3.02.08a.i, Item 09, 10a, and lib (References 3 & 4) to verify that each remotely operated valve identified in COL Table 2.3.2-1 (Attachment G) assume the indicated loss of motive power position upon a loss of motive power.
The motor-operated valves are placed in the closed position and the power supply to the motor operator is opened. The valves are verified to remain in the closed position and an attempt is made to open the valves with controls in the MCR. The valves are verified to remain in the closed position locally. The air operated valves are placed in the open position and verified to be open locally. Power to the air supply solenoids are opened and the valves are verified to close locally. An attempt to open the valves is made using the controls in the MCR and the valves are verified to remain closed locally.
The test results confirm that upon loss of motive power on Unit 3 and Unit 4, each remotely operated valve identified in Attachment G assumes the indicated loss of motive power position.
Controls in the MCR cause pumps identified in Table 2.3.2-3 to perform the listed function.
Testing is performed in accordance with Unit 3 and Unit 4 component test procedures SV3-ITAAC-ST-2.3.02.08a.i, Items 12a, 12b, 13 and SV4-ITAAC-ST-2.3.02.08a.i, Items 12a, 12b, 13 (References 11 & 12) to confirm controls in the MCR cause the pumps identified in COL Table 2.3.2-3 (Attachment H) to perform the listed function.
Testing is performed at an operator work station by navigating to the CVS makeup and letdown system screen. The A CVS makeup pump is started and verified to be running locally. The A CVS makeup pump is stopped and the B CVS makeup pump is started and verified to be running locally.
The test results confirm that controls in Unit 3 and Unit 4 MCR cause pumps identified in Attachment H to perform the listed function.
The pumps identified in Table 2.3.2-3 start after a sional is generated bv the PLS.
Testing is performed in accordance with Unit 3 and Unit 4 component test procedures SV3-ITAAC-ST-2.3.02.08a.i, Items 12a, 12b, 13 and SV4-ITAAC-ST-2.3.02.08a.i, Items 12a, 12b, 13 (References 11 & 12) to confirm controls in the MCR cause the pumps identified in COL Table 2.3.2-3 (Attachment H) to perform the listed function.
Testing is performed at a PLS operator work station by navigating to the CVS - makeup and letdown system screen. The A CVS makeup pump Is started and verified to be running locally.
The A CVS makeup pump is stopped and the B CVS makeup pump is started and verified to be running locally.
The test results confirm that controls in Unit 3 and Unit 4 MCR cause pumps identified in Attachment H to perform the listed function.
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 9 of 16 Displays identified in Table 2.3.2-3 can be retrieved in the MGR.
An inspection is performed in accordance with Unit 3 and Unit 4 component test procedures SV3-ITAAC-ST-2.3.02.08a.i, Items 12a, 12b, 13 and SV4-ITAAC-ST-2.3.02.08a.i, Items 12a, 12b, 13 (References 11 & 12) to confirm displays identified in COL Table 2.3.2-3 (Attachment I) can be retrieved in the MGR.
Testing is performed at an operator work station by navigating to several CVS system screens, locating the items identified in Attachment I, and ensuring the items identified can be retrieved in the MGR.
The test results demonstrate that displays identified in Table 2.3.2-3 can be retrieved in the Unit 3 MGR and in the Unit 4 MGR.
References 1 through 12 are available for NRG inspection as part of Unit 3 and Unit 4 ITAAG Completion Packages (Reference 13 and 14).
List of ITAAC Findings In accordance with plant procedures for ITAAG completion. Southern Nuclear Operating Company (SNG) performed a review of all findings pertaining to the subject ITAAG and associated corrective actions. This review found there are no relevant ITAAG findings associated with this ITAAG.
References favaiiabie for NRC inspection)
- 1. 3-GVS-ITPP-502, "Chemical and Volume Control System Pre-core Hot Functional Test Preoperational Test Procedure"
- 2. 4-GVS-ITPP-502, "Chemical and Volume Control System Pre-core Hot Functional Test Preoperational Test Procedure"
- 3. SV3-ITAAG-ST-2.3.02.08a.i, Item 09,10a, and 1 lb "CVS Remotely Operated Valve Stroke Test -
ITAAG: SV3-2.3.02.08a.i, Item 09,10a, and lib"
- 4. SV4-ITAAG-ST-2.3.02.08a.i, Item 09,10a, and 1 lb "CVS Remotely Operated Valve Stroke Test -
ITAAG: SV3-2.3.02.08a.i, Item 09,10a, and lib"
- 5. 3-PMS-ITPP-504, "PMS REACTOR TRIP BREAKERS"
- 6. 4-PMS-ITPP-504, "PMS REACTOR TRIP BREAKERS
- 7. 3-PMS-ITPP-523, "Containment Pressure High-2 Actuation Preoperational Test Procedure"
- 8. 4-PMS-ITPP-523, "Containment Pressure High-2 Actuation Preoperational Test Procedure"
- 9. 3-PMS-ITPP-524, "PMS Gold Actuations Preoperational Test Procedure" 10.4-PMS-ITPP-524, "PMS Gold Actuations Preoperational Test Procedure"
- 11. SV3-ITAAG-ST-2.3.02.08a.i, Items 12a, 12b, 13, "CVS Component Indication Verifications"
- 12. SV4-ITAAG-ST-2.3.02.08a.i, Items 12a, 12b, 13, "CVS Component Indication Verifications" 13.2.3.02.08a.i-U3-GP-Rev 0, ITAAG Completion Package 14.2.3.02.08a.i-U4-GP-Rev 0, ITAAG Completion Package
- 15. NEI 08-01, "Industry Guideline for the ITAAG Closure Process Under 10 GFR Part 52"
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 10 of 16 Attachment A Excerpt from COL Appendix C Table 2.3.2-1 Table 2.3.2-1 Equipment Name Tag No.
Safety-Related Display RCS Purification Motor-Operated Isolation Valve CVS-PL-V001 Yes (Valve Position)
RCS Purification Motor-Operated Isolation Valve CVS-PL-V002 Yes (Valve Position)
RCS Purification Motor-Operated Isolation Valve CVS-PL-V003 Yes (Vaive Position)
CVS Letdown Containment Isolation Valve CVS-PL-V045 Yes (Valve Position)
CVS Letdown Containment Isolation Valve CVS-PL-V047 Yes (Valve Position)
CVS Auxiliary Pressurizer Spray Line Pressure Boundary Valve CVS-PL-V084 Yes (Valve Position)
CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V090 Yes (Valve Position)
CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V091 Yes (Valve Position)
CVS Zinc Injection Containment Isolation Valve ORC CVS-PL-V092 Yes (Valve Position)
CVS Zinc Injection Containment Isolation Valve IRC CVS-PL-V094 Yes (Valve Position)
CVS Demineralized Water Isolation Valve CVS-PL-V136A Yes (Valve Position)
CVS Demineralized Water Isolation Valve CVS-PL-V136B Yes (Valve Position)
CVS Hydrogen Injection Containment Isolation Valve ORC CVS-PL-V219 Yes (Valve Position)
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 11 of 16 Attachment B Excerpt from COL Appendix C Table 2.3.2-1 Table 2.3.2-1 Equipment Name Tag No.
Remotely Operated Valve Active Function RCS Purification Motor-Operated Isolation Valve CVS-PL-V001 Yes Transfer Closed RCS Purification Motor-Operated Isolation Valve CVS-PL-V002 Yes Transfer Closed RCS Purification Motor-Operated Isolation Valve CVS-PL-V003 Yes Transfer Closed CVS Letdown Containment Isolation Valve CVS-PL-V045 Yes Transfer Closed CVS Letdown Containment Isolation Valve CVS-PL-V047 Yes Transfer Closed CVS Auxiliary Pressurizer Spray Line Pressure Boundary Valve CVS-PL-V084 Yes Transfer Closed CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V090 Yes Transfer Closed CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V091 Yes Transfer Closed CVS Zinc Injection Containment Isolation Valve ORC CVS-PL-V092 Yes Transfer Closed CVS Zinc Injection Containment Isolation Valve IRC CVS-PL-V094 Yes Transfer Closed CVS Demineralized Water Isolation Valve CVS-PL-V136A Yes Transfer Closed CVS Demineralized Water Isolation Valve CVS-PL-V136B Yes Transfer Closed CVS Hydrogen Injection Containment Isolation Valve ORC CVS-PL-V219 Yes Transfer Closed
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 12 of 16 Excerpt from COL Appendix C Table 2.3.2-1 Table 2.3.2-1 Equipment Name Tag No.
Control PMS Active Function PCS Purification Motor-Operated Isolation Valve CVS-PL-V001 Yes Transfer Closed PCS Purification Motor-Operated Isolation Valve CVS-PL-V002 Yes Transfer Closed PCS Purification Motor-Operated Isolation Valve CVS-PL-V003 Yes Transfer Closed CVS Letdown Containment Isolation Valve CVS-PL-V045 Yes Transfer Closed CVS Letdown Containment Isolation Valve CVS-PL-V047 Yes Transfer Closed CVS Auxiliary Pressurizer Spray Line Pressure Boundary Valve CVS-PL-V084 Yes Transfer Closed CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V090 Yes Transfer Closed CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V091 Yes Transfer Closed CVS Zinc Injection Containment Isolation Valve OPC CVS-PL-V092 Yes Transfer Closed CVS Zinc Injection Containment Isolation Valve IPC CVS-PL-V094 Yes Transfer Closed CVS Deminerallzed Water Isolation Valve CVS-PL-V136A Yes Transfer Closed CVS Deminerallzed Water Isolation Valve CVS-PL-V136B Yes Transfer Closed CVS Hydrogen Injection Containment Isolation Valve OPC CVS-PL-V219 Yes Transfer Closed
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 13 of 16 Attachment D Excerpt from COL Appendix C Table 2.3.2-1 Table 2.3.2-1 Equipment Name Tag No.
Remotely Operated Valve Control PMS Closure Time CVS Makeup Line 3-CVS-PL-Yes Yes XX sec Containment V090 isolation Motor-operated Valve CVS Makeup Line 3-CVS-PL-Yes Yes XX sec Containment V091 Isolation Motor-operated Valve CVS Demineralized 3-CVS-PL-Yes Yes XX sec Water Isolation V136A Valve CVS Demineralized 3-CVS-PL-Yes Yes XX sec Water Isolation V136B Valve CVS Makeup Line 4-CVS-PL-Yes Yes XX sec Containment V090 Isolation Motor-operated Valve CVS Makeup Line 4-CVS-PL-Yes Yes XX sec Containment V091 Isolation Motor-operated Valve CVS Demineralized 4-CVS-PL-Yes Yes XX sec Water Isolation V136A Valve CVS Demineralized 4-CVS-PL-Yes Yes XX sec Water Isolation V136B Valve
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 14 of 16 Attachment E Excerpt from COL Appendix C Table 2.3.2-1 Table 2.3.2-1 Equipment Name Tag No.
Active Function RCS Purification Motor-Operated Isolation Valve CVS-PL-V001 Transfer Closed RCS Purification Motor-Operated Isolation Valve CVS-PL-V002 Transfer Closed RCS Purification Motor-Operated Isolation Valve CVS-PL-V003 Transfer Closed CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V090 Transfer Closed CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V091 Transfer Closed Attachment F Excerpt from COL Appendix C Table 2.3.2-1 Table 2.3.2-1 Equipment Name Tag No.
Active Function CVS Makeup Return Line Bypass Check Valve CVS-PL-V067 Transfer Open/
Transfer Closed CVS Purification Return Line CVS-PL-V080 Transfer Pressure Boundary Check Valve Closed CVS Purification Return Line CVS-PL-V081 Transfer Pressure Boundary Isolation Check Valve Closed CVS Purification Return Line CVS-PL-V082 Transfer Pressure Boundary Check Valve Closed CVS Auxiliary Pressurizer Spray Line Pressure Boundary Check Valve CVS-PL-V085 Transfer Closed CVS Makeup Line Containment Isolation Thermal Relief Valve CVS-PL-V100 Transfer Open/
Transfer Closed CVS Hydrogen Injection Containment Isolation Check CVS-PL-V217 Transfer Closed Valve IRC
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 15 of 16 Attachment G Excerpt from COL Appendix C Tabie 2.3.2-1 Table 2.3.2-1 Equipment Name Tag No.
Remotely Operated Valve Loss of Motive Power Position RCS Purification Motor-Operated Isolation Valve CVS-PL-V001 Yes As Is RCS Purification Motor-Operated Isolation Valve CVS-PL-V002 Yes As Is RCS Purification Motor-Operated Isolation Valve CVS-PL-V003 Yes As Is CVS Letdown Containment Isolation Vaive CVS-PL-V045 Yes Closed CVS Letdown Containment Isoiation Valve CVS-PL-V047 Yes Closed CVS Auxiliary Pressurizer Spray Line Pressure Boundary Valve CVS-PL-V084 Yes Closed CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V090 Yes As Is CVS Makeup Line Containment Isolation Motor-operated Valve CVS-PL-V091 Yes As Is CVS Zinc Injection Containment Isolation Vaive ORC CVS-PL-V092 Yes Closed CVS Zinc Injection Containment Isoiation Valve IRC CVS-PL-V094 Yes Closed CVS Demineralized Water Isolation Valve CVS-PL-V136A Yes Closed CVS Demineralized Water Isolation Valve CVS-PL-V136B Yes Closed CVS Hydrogen Injection Containment Isolation Valve ORC CVS-PL-V219 Yes Closed Attachment H Excerpt from COL Appendix C Table 2.3.2-3 Table 2.3.2-1 Equipment Tag No.
Control Function CVS Makeup Pump A CVS-MP-01A Start CVS Makeup Pump B CVS-MP-01B Start
U.S. Nuclear Regulatory Commission ND-19-0077 Enclosure Page 16 of 16 Attachment I Excerpt from COL Appendix C Table 2.3.2-3 Equipment Name Tag No.
Display CVS Makeup Pump A CVS-MP-01A Yes (Run Status)
CVS Makeup Pump B CVS-MP-01B Yes (Run Status)
Purification Flow Sensor CVS-001 Yes Purification Return Flow Sensor CVS-025 Yes CVS Purification Return Line (Position Indicator)
CVS-PL-V081 Yes Auxiliary Spray Line Isolation Valve (Position Indicator)
CVS-PL-V084 Yes Boric Acid Storage Tank Level Sensor CVS-109 Yes Boric Acid Flow Sensor CVS-115 Yes Makeup Blend Valve (Position Indicator)
CVS-PL-V115 Yes CVS Demineralized Water Isolation Valve (Position Indicator)
CVS-PL-V136A Yes CVS Demineralized Water Isolation Valve (Position Indicator)
CVS-PL-V136B Yes Makeup Pump Discharge Flow Sensor CVS-157 Yes Makeup Flow Control Valve (Position Indicator)
CVS-PL-V157 Yes