C-428 Amendment No. 167 Table 3.3-6 Inspections, Tests, Analyses, and Acceptance Criteria No.

ITAAC No.

Design Commitment Inspections, Tests, Analyses Acceptance Criteria 781 3.3.00.04a Not used per Amendment No. 167 782 3.3.00.04b 4.b) Walls of the waste accumulation room in the radwaste building except for designed openings or penetrations provide shielding during normal operations.

Inspection of the as-built radwaste building wall thicknesses will be performed.

A report exists and concludes that the shield walls of the waste accumulation room in the radwaste building except for designed openings or penetrations are consistent with the minimum concrete wall thicknesses of 1'-4", and a minimum concrete wall thickness of 1'-8" near the radwaste bunkers, or the report documents an evaluation of thickness deviations identified during construction and demonstrates there is no impact to compliance with the radiation protection licensing basis.

783 Deleted.

784 3.3.00.05a 5.a) Exterior walls and the basemat of the nuclear island have a water barrier up to site grade.

An inspection of the as-built water barrier will be performed during construction.

A report exists that confirms that a water barrier exists on the nuclear island exterior walls up to site grade.

785 3.3.00.05b 5.b) The boundaries between rooms identified in Table 3.3-2 of the auxiliary building are designed to prevent flooding of rooms that contain safety-related equipment.

An inspection of the auxiliary building rooms will be performed.

A report exists that confirms floors and walls as identified on Table 3.3-2 have provisions to prevent flooding between rooms up to the maximum flood levels for each room defined in Table 3.3-2.