Other: ML18101A024, ML18108A052, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18221A281, ML19121A263, ML19121A265, ML19121A267, ML19121A268, ML19184A181, ML19184A184, ML19184A186, ML19184A187, ML19204A242, ML19204A244, ML19204A248, ML19204A251, ML19280B250, ML20065N277, ML20065N278, ML20065N280, ML20065N281, ML20065N282, ML20065N285
|
MONTHYEARML18101A0222018-03-15015 March 2018 Tn Americas LLC - Affidavit Project stage: Request ML18101A0202018-03-19019 March 2018 Independent Spent Fuel Storage Installation - Submittal of Application for the License Renewal Project stage: Request ML18101A0242018-03-31031 March 2018 ISFSI - License Renewal Application, Revision 0 Project stage: Other ML18221A2812018-03-31031 March 2018 ISFSI - Enclosure 4 to Dpg 18-051 License Renewal Application, Revision 0 Project stage: Other ML18108A0522018-04-12012 April 2018 E-mail from W. Reed/Dsfm to D. Tallman/Sacramento Municipal Utility District/Rancho Seco Assets Acknowledgement of Rancho Seco ISFSI Renewal Application Project stage: Other ML18150A0862018-05-29029 May 2018 Letter to D. Tallman Request for Supplemental Information for Acceptance Review of the Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation License No. SNM-2510 (W/Enclosursi and Observations) Project stage: Acceptance Review ML18149A5722018-05-29029 May 2018 Conversation Record with D. Tallman Et. Al/Sacramento Municipal Utility District Discuss Draft Technical Request for Supplemental Information and Observation on Rancho Seco Independent Spent Fuel Storage Installation Renewal Application Project stage: Draft Other ML18179A2662018-06-25025 June 2018 Enclosure 10 - California All Purpose Acknowledgment of Smud Affirmation Pursuant to 10 CFR 72.16(b) Project stage: Other ML18179A2582018-06-25025 June 2018 Enclosure 2 - Rsi and Observations and Responses Project stage: Other ML18179A2562018-06-25025 June 2018 Transmittal of Response to Request for Supplemental Information for Acceptance Review of the Application for the Renewal of 10 CFR Part 72 Special Nuclear Materials License No. SNM-2510 for the Rancho Seco Independent Spent Fuel Storage ins Project stage: Supplement ML18179A2602018-06-30030 June 2018 Enclosure 4 - Rancho Seco ISFSI License Renewal Application, Revision 1 (Non-Proprietary Version) Project stage: Other ML18201A4552018-07-20020 July 2018 Letter to D. Tallman Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation License No. SNM 2510 - Accepted for Review (Cac/Epid Nos. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0004) Project stage: Other ML18215A3702018-08-0303 August 2018 Conversation Record with D. Shaw (Tn) Discuss Declared Proprietary Information in License Renewal Application (Conversation Held on July 20, 2018) Project stage: Approval ML18221A2782018-08-0303 August 2018 ISFSI - Affidavit Pursuant to 10CFR2.390 for Enclosure 1 to Dpg 18-138 Project stage: Request ML18221A2922018-08-0303 August 2018 ISFSI - Enclosure 1 to Dpg 18-139, Affidavit Pursuant to 10CFR2.390 Project stage: Request ML18261A0312018-09-14014 September 2018 Letter to D. Tallman U.S. NRC Approval of Sacramento Municipal Utility Request for Withholding Information from Public Disclosure for Rancho Seco ISFSI (Cac/Epid Nos. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0004) Project stage: Withholding Request Acceptance ML18261A0102018-09-14014 September 2018 Letter to D. Tallman U.S. NRC Approval of Sacramento Municipal Utility Request for Withholding Information from Public Disclosure for Rancho Seco ISFSI (Cac/Epid Nos. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0004) Project stage: Withholding Request Acceptance ML18261A0222018-09-14014 September 2018 Letter to D. Tallman U.S. NRC Approval of Sacramento Municipal Utility Request for Withholding Information from Public Disclosure for Rancho Seco ISFSI (Cac/Epid Nos. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0004) Project stage: Withholding Request Acceptance ML18285A3812018-09-26026 September 2018 Transmittal of Response to Request for Information for Review of the Application for the Renewal of 10 CFR Part 72 Special Nuclear Materials License No. SNM-2510 for the Rancho Seco Independent Spend Fuel Storage Installation Project stage: Response to RAI ML18325A1422018-11-20020 November 2018 Letter to D. Tallman Request for Additional Information for Review of the Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation License No. SNM-2510 (Cac/Epid Nos. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0 Project stage: RAI ML19121A2682019-04-17017 April 2019 Sacramento Municipal Utility District (Smud) - California All Purpose Acknowledgment Affirmation Pursuant to 10 CFR 72.16(b) Project stage: Other ML19121A2632019-04-22022 April 2019 Independent Spent Fuel Storage Installation - Affidavit Project stage: Other ML19184A1842019-04-22022 April 2019 Enclosure 3 - RAIs and Responses (Non-Proprietary) Project stage: Other ML19184A1822019-04-22022 April 2019 Enclosure 2 - Replacement Transmittal Letter Regarding Response to Request for Additional Information for Review of the Application for the Renewal of 10 CFR Part 72 Special Nuclear Materials Project stage: Response to RAI ML19121A2652019-04-22022 April 2019 Independent Spent Fuel Storage Installation - RAIs and Responses Project stage: Other ML19121A2672019-04-22022 April 2019 ISFSI - License Renewal Application, Revision 2 Project stage: Other ML19121A2622019-04-22022 April 2019 Sacramento Municipal Utility District (Smud) - Rancho Seco Independent Spent Fuel Storage Installation - Response to Request for Additional Information for Review of the Application for Renewal of 10 CFR Part 72 Special Project stage: Response to RAI ML19184A1862019-04-30030 April 2019 Enclosure 5 - LRA R2 (Non-Proprietary) Project stage: Other ML19168A0582019-06-13013 June 2019 Letter to D. Tallman Request for Clarification of Response to Additional Information for the Technical Review of the Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation License No. SNM-2510 (W/Enclosure) Project stage: Approval ML19184A1872019-06-24024 June 2019 Enclosure 7 - CA All Purpose Acknowledgment of Smud Affirmation Project stage: Other ML19184A1812019-06-25025 June 2019 Enclosure 1 - Affidavit Project stage: Other ML19184A1802019-06-26026 June 2019 Independent Spent Fuel Storage Installation Replacement Files for the Response to Request for Additional Information for Review of the Application for the Renewal of 10 CFR Part 72 Special Nuclear Materials License Project stage: Response to RAI ML19204A2512019-07-0101 July 2019 Enclosure 8 to DPG-19-087 - CA Acknowledgment of Smud Affirmation Project stage: Other ML19204A2422019-07-10010 July 2019 Enclosure 1 to Dpg 19-087 - Tn Americas, LLC Affidavit Project stage: Other ML19204A2442019-07-12012 July 2019 Enclosure 3 to DPG-19-087 - RAI Clarifications and Responses (Non-Proprietary) Project stage: Other ML19204A2412019-07-12012 July 2019 Submittal of Response to Request for Clarification of Response to Additional Information for the Technical Review of the Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation Project stage: Request ML19204A2482019-07-31031 July 2019 Enclosure 5 to DPG-19-087 - Rancho Seco ISFSI License Renewal Application, Revision 3 (Non-Proprietary) Project stage: Other ML19280B7632019-09-30030 September 2019 Letter to D. Tallman Nuclear Regulatory Commission Approval If Sacramento Municipal Utility District Request for Withholding Information from Public Disclosure for Rancho Seco ISFSI Project stage: Withholding Request Acceptance ML19280B2502019-09-30030 September 2019 Conversation Record with D. Tallman/Smud Discuss California Department of Fish and Wildlife Recommendations for the California Tiger Salamander, Conversation Held on September 24, 2019 Project stage: Other ML19326B2162019-11-22022 November 2019 Summary of October 24, 2019 Meeting with ISP on Draft RAI Responses Project stage: Draft RAI ML20038A1312020-01-23023 January 2020 Request for Minor Editorial and Clarification Revisions for the Technical Review of the Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation License No. SNM-2510(CAC/EPID Nos. 001028/L-2018-RNW-0005;000993/ Project stage: Request ML20044F6012020-02-24024 February 2020 ISFSI Renewal Proprietary Determination Letter for RAI Clarification Submittal 7-12-19 Project stage: RAI ML20065N2822020-03-0909 March 2020 ISFSI Renewed License Project stage: Other ML20065N2812020-03-0909 March 2020 ISFSI Preamble-License Renewal Order Project stage: Other ML20065N2772020-03-0909 March 2020 ISFSI Renewal Cover Letter Project stage: Other ML20065N2852020-03-0909 March 2020 ISFSI Renewed Technical Specifications Project stage: Other ML20065N2782020-03-11011 March 2020 ISFSI FRN Notice of Issuance for License Renewal Project stage: Other ML20065N2802020-03-31031 March 2020 ISFSI License Renewal SER Project stage: Other 2019-04-22
[Table View] |
Text
NRC FORM 699 /""'~'I, (03-2013)
!~c U.S. NUCLEAR REGULA TORY COMMISSION DATE OF SIGNATURE
\\W:Wj CONVERSATION RECORD 05/29/2018 NAME OF PERSON(S) CONTACTED OR IN CONTACT WITH YOU Sacramento Municipal Utility District (SMUD)
E-MAIL ADDRESS ORGANIZATION SMUD LICENSE NUMBER(S)
SNM-2510 SUBJECT DOCKET NUMBER(S) 72-11 CONTROL NUMBER(S)
DATE OF CONTACT 05/23/2018 TELEPHONE NUMBER TYPE OF CONVERSATION DE-MAIL
[l] TELEPHONE D INCOMING
[l] OUTGOING 001028/L-2018-RNW-0005 and 000993/L-2018-LNE-0004 Discuss draft technical request for supplemental information (RSI} and observations on Rancho Seco Independent Spent Fuel Storage Installation (ISFSI} renewal application
SUMMARY
SMUD attendees: Dan Tallman (SMUD), Brad Gacke (SMUD), Brian Gutherman (Gutherman Technical Services), Ray Phan (TN Americas), Don Shaw (TN Americas), Karan Mauskar (TN Americas)
NRC attendees: Darrell Dunn (Senior Materials Engineer}, Hipolito Gonzalez (Chief, Renewals and Materials Branch), Wendy Reed (Chemist)
A teleconference was held between NRC and SMUD representatives to discuss the draft technical RSis and observations on the Rancho Seco renewal application, which were provided to SMUD on May 22, 2018.
The purpose of the call was to: (1) ensure a common understanding of the RSis and observations; (2) ensure that the RSis and observations are not already addressed in the current submittal; and (3) establish an appropriate response date for SMUD to respond to theRSis.
During the discussion, the NRC staff clarified draft observations 2, 3, 7, 8, 11, and 14 in response to SMUD's questions.
Continue on Page 2 ACTION REQUIRED (IF ANY)
SMUD will provide responses to the RSis and most observations in the form of track changes in a revised electronic submittal of the license renewal application (rev. 1) by June 25, 2018.
NRC staff will add text to the final RSI and observations letter that acknowledges the timely submittal by SMUD of the Rancho Seco ISFSI license renewal application.
NRC to issue the final RSI and observations letter to SMUD.
Continue on Page 3 NAME OF PERSON DOCUMENTING CONVERSATION Wendy Reed SIGNATURE NRC FORM 699 (03-2013)
Page 1 of 2
NRC FORM699 (03-2013)
SUMMARY
- (Continued from page 1)
U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD (continued)
Observation (OBS} NRC staff clarified that SMUD should provide the comparison between the Rancho Seco sample collection protocol with that ofEPRI. SMUD needs to clarify the uncertainties of the data used in the renewal application. 1N Americas will take the action to address.
OBS NRC staff clarified that an editorial change is needed to the application in Section 3.4.4.4 that would describe the licensing basis in the context of the contents of the DSC.
OBS The NRC staff clarified that they are looking for a basis and/or reference for the depth of the beat affected zone quoted in Section 3.4.4.5.
OBS The NRC staff noted that Application Section 3.5.4.5 does not address whether lubricant deterioration affects retrievability.
OBS The NRC staff notes that, for consistency, Application Section B.3 DSC External Surfaces Aging Management Program may need to include a tollgate discussion to assess effectiveness of corrective actions and update the AMP as necessaiy.
OBS The NRC clarified that the potential use of the MP-187 transfer cask to serve as a pressure boundary for a leaking dry shielded canister (DSC) as described in the renewal application needs to be considered in the MP-187 aging management program.
SMUD informed the NRC staff that, because of the effort required to address this observation, they may defer and address as a request for additional information during the application review period.
NRC FORM 699 (03-2013)
Page 2 of 2