ATTACHMENT 2 Proposed Technical Specification Changes (This proposal supercedes the submittal of August 9, 1985, Serial No. 556)

'~

8512310192 851220 PDR ADOCK 05000289 P

PDR

e TS 3.20-1 3.20 SHOCK SUPPRESSORS (SNUBBERS)

Applicability Applies to all shock suppressors (snubbers) which are required to protect the reactor coolant system and other safety-related systems.

Snubbers excluded from this inspection program are those installed on non-safety-related systems and then only if their failure or failure of the system on which they are installed would have no adverse effects on any safety-related system.

Objective To define those limiting conditions for operation that are necessary to ensure that all snubbers required to protect the reactor coolant system, or any other safety-related system or component, are operable during reactor operation.

Specifications A.

During all modes of operation except Cold Shutdown and Refueling, all snubbers required to protect the reactor coolant system and other safety related systems shall be operable except as noted in 3.20.B and 3.20.C below.

B.

If any snubber required to protect the reactor coolant system and other safety-related systems is found to be inoperable, it must be repaired and made operable, or otherwise replaced with one which is operable within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

C.

If the requirements of Specification B cannot be met, an orderly shutdown shall be initiated, and the reactor shall be in the hot shutdown condition within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

TS 3.20-2 D.

If a snubber is determined to be inoperable while the reactor is in the shutdown or refueling mode, the snubber shall be made operable or replaced prior to reactor startup.

Basis Snubbers are designed to prevent unrestrained pipe motion under dynamic loads as might occur during an earthquake or severe transient while allowing normal thermal motion during startup and shutdown.

The con-sequence of an inoperable snubber is an increase in the probability of structural damage to piping as a result of a seismic or other event initiating dynamic loads.

It is therefore required that all snubbers required to protect the primary coolant system, or any other safety related system or component, be operable during reactor operation.

Because snubber protection is required only during low probability events, a period of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is allowed for repairs of replacement.

In case a shutdown is required, the allowance of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> to reach a hot shutdown condition will permit an orderly shutdown consistent with standard operating procedures.

Since plant startup should not commence with knowingly defective safety related equipment, Specification 3.20.D prohibits startup with inoperable snubbers.

e TS 4.17-1 4.17 SHOCK SUPPRESSORS (SNUBBERS)

Applicability Applies to all hydraulic and mechanical shock suppressors (snubbers) which are required to protect the reactor coolant system and other safety-related systems.

Snubbers excluded from this inspection are those installed on non-safety-related systems and then only if their failure or failure of the system on which they are installed would have no adverse effect on any safety-related system.

Objective To specify the minimum frequency and type of surveillance to be applied to the hydraulic and mechanical snubbers required to protect the reactor coolant system and other safety-related systems.

Specification Each snubber shall be demonstrated operable by performance of the follow-ing augmented inservice inspection program and the requirements of Specification 4.0.

A.

Visual Inspections

1.

The first inservice visual inspection of snubbers shall be performed after four months but within 10 months of commencing power operation and shall include all snubbers required to protect the reactor coolant system and other safety-related systems.

If less than two (2) snubbers are found inoperable during the first inservice visual inspection, the second inservice visual inspection shall be performed 12 months+/- 25%

from the date of the first inspection.

Otherwise, subsequent visual inspections shall be performed in accordance with the following schedule:

e e

TS 4.17-4

c.

Snubbers within 10 feet of the discharge from a safety relief valve

4.

Snubbers identified as "Especially Difficult to Remove" or in "High Radiation Zone During Shutdown" shall also be included in the representative sample.*

5.

In addition to the regular sample, snubbers which failed the previous functional test shall be retested during the next test period.

If a spare snubber has been installed in place of a failed snubber, then both the failed snubber (if it is repaired and installed in another position) and the spare snubber shall be retested.

Test results of these snubbers may not be included for the resampling.

6.

For each snubber that does not meet the functional acceptance criteria of Specification 4.17.D or 4.17.E, an additional 10%

of that type of snubber shall be functionally tested.

7.

For snubbers of 50 kips and above that are extremely difficult to remove or in high radiation zones that fail the functional testing, an engineering evaluation is required to determine the failure mode.

If the failure is determined to be non-generic, an additional 10% of that category will be tested during the next functional test period.

  • Permanent or other exemptions from functional testing for individual snubbers in these categories may be granted by the Commisson only if a justifiable basis for exemption is presented and/or snubber life destructive testing was performed to qualify snubber operability for all design conditions at either the completion of their fabrication or at subsequent date.

D.

e TS 4,17-5

8.

If any snubber selected for functional testing either fails to lockup or fails to move, i.e., frozen in place, the cause will be evaluated and if caused by manufacturer or design deficiency all snubbers of the same design subject to the same defect shall be functionally tested.

This testing requirement shall be independent of the requirements stated above for snubbers not meeting the functional test acceptance criteria.

9, For the snubber(s) found inoperable, an engineering evaluation shall be performed on the components which are supported by snubber(s).

The purpose of this engineering evaluation shall be to determine if the components supported by the snubber(s) were adversely affected by the inoperability of the snubber(s) in order to ensure that the supported component remains cap-able of meeting the designed service.

Hydraulic Snubbers Functional Test Acceptance Criteria

1.

The hydraulic snubber functional test shall verify that:

a.

Activation (restraining action) is achieved within the specified range of velocity or acceleration in both tension and compression.

b.

Snubber bleed, or release rate, where required, is within the specified range in compression and tension.

For snubbers specifically required to not displace under con-tinuous load, the ability of the snubber to withstand load without displacement shall be verified.

_J

e e

TS 4.17-6 E.

Mechanical Snubbers Functional Test Acceptance Criteria

1.

The mechanical snubbers functional test shall verify that:

a.

The force that initiates free movement of the snubber rod in either tension or compression is less than the speci-fied maximum drag force.

Drag force shall not have increased more than 50% since the last functional test.

b.

Activation (restraining action) is achieved within the specified range of velocity in both tension and compres-sion.

c.

Snubber release rate, where required, is within the speci-fied range in compression and tension.

For snubbers specifically required not to displace under continuous load, the ability of the snubber to withstand load without displacement shall be verified.

F.

Snubber Service Life Monitoring

1.

A record of the service life of each snubber, the date at which the designated service life commences, and the installa-tion and maintenance records on which the designated service life is based shall be maintained as required by Specification 6.5.B.9.

2.

Concurrent with the first inservice visual inspection and at least once per 18 months thereafter, the installation and maintenance records for each snubber shall be reviewed to verify that the indicated service life has not been exceeded or will not be exceeded prior to the next scheduled snubber service life review.

If the indicated service life will be

e TS 4.17-10 All table pages are deleted 4.17-10 through 4.17-52.

TS 6.5-3

9.

Records of the service lives of all hydraulic and mechanical snubbers on safety-related systems, including the date at which the service life commences and associated installation and maintenance records.

10.

Records of the annual audit of the Station Emergency Plan and implementing procedures.

11.

Records of the annual audit of the Station Security Plan and implementing procedures.

Revised Safety Evaluation

e SAFETY EVALUATION FOR SPS TECHNICAL SPECIFICATIONS CHANGE The proposed change will add a statement to Technical Specification 3.20.A and B specifying which snubbers shall be operable and delete Tables 4.17-2 and 4.17-2.

This Technical Specification change will remove the requirement to update the Technical Specifications when a snubber is added or deleted from the plant.

This is in accordance with NRC Generic Letter 84-13, dated May 3, 1984, "Technical Specification for Snubbers." Generic Letter 84-13 recommends that Tables 4.17-1 and 4.17-2 be eliminated from the Technical Specifications.

Generic Letter 84-13 also recommends that the Technical Specifications be modified to specify which snubbers are required to be operable.

This revision includes a statement specifying "All snubbers required to protect the reactor coolant system and other safety-related systems shall be operable".

A list of installed snubbers will be maintained current in plant administrative pro-cedures and plant records will be maintained as required by Technical Speci-fication 4.17.G.l.

Technical Specification 4.17.G.l. requires "a record of the service life of each snubber, the date at which the designated service life commenced and the installation and maintenance records on which the designated service life is based shall be maintained."

The addition or deletion of a snubber will be documented in the plant records.

These two changes are in accordance with the recommendations of Generic Letter 84-13.

50.59 Safety Review Pursuant to 10CFR50.59, we have reviewed the proposed Technical Specification change and have concluded that no unreviewed safety question exists.

Because (i) the probability of occurrence or the consequence of an accident or mal-function is not increased by these changes; (ii) the possibility of a different type of accident other than discussed in the UFSAR has not been created by this proposed change; and (iii) the margin of safety as defined in the basis for any Technical Specification is not reduced, in that the change is purely administrative and the Limiting Condition for Operation, surveillance frequencies, and the plant design have not changed.

<:.I.

If 59.92 Significant Hazards Review The Commission has provided standards (10 CFR 50.92 (c)) for determining whether a significant hazards consideration exists. A proposed amendment to an operating license for a facility involves no significant hazards consideration if operation of the facility in accordance with the proposed amendment would not (1) involve a significant increase in the probability or consequences of an accident previously evaluated; or (2) create the probability of a new or different kind of accident from any accident previously evaluated; or (3) involve a significant reduction in a margin of safety.

The proposed change is administrative and only deletes the existing snubber tables.

Plant design LCO's and surveillance frequencies remain unchanged.

Because the probability or consequences of an accident has not increased, the margin to safety has not been reduced and we have not created the probability of a new or different type of accident from those previously evaluated.

There are no significant hazard considerations involved for this Technical Specification change.