Application for Amends to Licenses DPR-32 & DPR-37,changing Tech Specs 3.20 & 4.17 to Remove Snubber Tables Per Generic Ltr 84-13
ML18144A138
Person / Time
Site: Surry  
Issue date: 12/20/1985
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, Rubenstein L
Office of Nuclear Reactor Regulation
Shared Package
ML18144A139 List:
References
85-751A, GL-84-13, TAC-59466, TAC-59467, NUDOCS 8512310190
Download: ML18144A138 (6)


Text

'.

e e

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261

w. L. STEWART VICE PRESIDENT NUCLEAR OPERATIONS December 20, 1985 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Attn:

Mr. Lester S. Rubenstein, Director PWR Project Directorate #2 Division of PWR Licensing-A U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Gentlemen:

VIRGINIA.ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT NOS. 1 AND 2 TECHNICAL SPECIFICATION CHANGE REQUEST Serial No.

85-751A NO/ETS/vlh Docket Nos.

50-280 50-281 License Nos. DPR-32 DPR-37 In our lett~r of November 19, 19,85, Serial No. 85-7 51, we committed to provide a response to your request for additional information and a revised Technical Specification proposal that removes the snubber tables from the Technical Specifications, in accordance with Generic Letter 84-13, dated May 3, 1984.

Since this request supercedes our previous submittal which included the appropriate application fee, no additional application fee is included herein.

Should you have any questions concerning this matter, please do not hesitate to call.

Very truly yours,

  • * ~

W. L. Stewart Attachments:

1.

Prop~sed Amendment for DPR-32 and DPR-37

2.

Safety Evaluation

3.

Response to NRC ~equest fo'r Additional Information 8512310190 851220 PDR ADOCK 05000280 p

PDR ADD:

PWR.:... A/BC Is TECH ::;Ur'r'Ultl

    • AD - J. Knight (ltr only)

EB (BALLARD)

EICSB (ROSA)

  • PSB (GAMMILL)

RSB (BERLINGER)

FOB (BENAROYA)

C'

.*,!i 1

l VIRGINIA. ELECTRIC AND POWER COMPANY TO cc:

Dr. J. Nelson Grace Regional Administrator NRC Region I I Mr. Donald J. Burke NRC Resident Inspector Surry Power Station Mr. Charles Price Department of Health 109 Governor Street Richmond, Virginia 23219 Mr. Terence L. Chan NRC Surry Project Manager PWR Project Directorate #2 Division of PWR Licensing-A

I ATTACHMENT 1 Response to NRC Questions dated October 11, 1985 as applicable to revised T.S. change proposal

NRC Question

1.

Applicability Section of Proposed Technical Specifications (TS) 3.20 and 4.17 Provide clarification to indicate whether the only snubbers which can be excluded from the TS requirements are those installed on non-safety related systems and then only if their failure or the failure of the system on which they are installed would have no adverse affect on any safety-related system.

Response

1.

The proposed specification has been revised to include the statement, "Snubbers excluded from this inspection program are those installed on non-safety-related systems and then only if their failure or failure of the system on which they are installed would have no adverse effects on any safety-related systems."

NRC Question

2.

Contrary to requirements of Section 3. 7. 9 of the Standard Technical Specification attached to Generic Letter 84-13, snubbers on systems required to be operable during cold shutdown and refueling are not required (according to proposed TS 3.20.A) to be operable during these conditions.

Provide a justification.

Response

2.

The proposed change to TS 3.20.A is to delete the phrase "listed in Technical Specification 4.17" which currently states: "During all modes of operation except Cold Shutdown and Refueling, all safety-related snubbers listed in Technical Specification 4.17 shall be operable except as noted in 3. 20. B and 3. 20. C below."

The change was solely to the listing of snubbers in a table which we propose to remove as recommended by Generic Letter 84-13.

The portion of the specification which the question appears to address is unchanged from the existing specification.

NRC Question

3.

Proposed TS Section 4.17.A - Inspection Groups The criteria to be used for subdividing accessible and inaccessible snubber groups into subgroups needs to be specified.

Since the ASME Standard, O&M-4, has not yet been published, and since this document has not yet been approved and accepted by NRC, the TS must specify definite criteria used to select the subgroups.

The criteria selected should be justified based on past testing and inspection results and the manufacturer's recommendation.

Response

3.

Not applicable to this submittal because "subgrouping" was not addressed in this request.

NRC Question

4.

Proposed TS Section 4.17.D.6 Functional testing of an additional 10% of the snubbers in the subgroup for each snubber failure within the subgroup does not meet the requirements of O&M-4 or the Standard Technical Specifications.

The draft of O&M-4 specifies that for each snubber that does not meet the functional test acceptance criteria, an additional sample of at least 1/2 the size of the initial sample lot shall be selected for functional testing.

Section 4.7.9.C of the Standard Technical Specifications requires that an additional 10% of the snubbers be functionally tested for each functional test failure.

This paragraph needs to be revised to discuss how the requirements of Section 4.7.9.C of the Standard Technical Specifications or O&M-4 will be met.

Response

4.

Not applicable to this submittal because subgroups and testing sample size were not addressed in this request.

NRC Question

5.

Proposed TS Sections 4.17.E.1.a and 4.17.F.1.b The word "Activity" appears to have been incorrectly used in the place of "Activation."

Please revise if appropriate.

Response

5.

The comment is correct.

The proposed specifications have been revised.

NRC Question

6.

Provide additional justification for considering some snubbers inside containment as accessible during power operation.

This justification should address ALARA concerns, as well as other safety concerns regarding exposure of snubber inspection personnel to the additional radiation hazards, high heat and humidity, and the subatmospheric containment environment.

Clarify how snubber reliability will be improved by reclassifying some snubbers currently considered inaccessible as accessible.

Response

6.

Not applicable to this submittal, because we have not addressed accessible and inaccessible requirements and constraints in this request.

NRC Question

7.

Safety Evaluation for SPS Technical Specification Change There are two clarification.

statements in the These are as follows:

Safety Evaluation which requires

a.

"Second line of second paragraph".... within the broad family of mechanical snubbers."

Since all mechanical snubbers installed at Surry were manufactured by PSA, and the various sizes of PSA snubbers are essentially similar in design, clarification of this statement is necessary.

b.

Fifth line of second paragraph -

Discussion regarding IE Bulletin 81-01 inspection criteria needs clarification or revision.

Response

IE Bulletin 81-01 contained two sets of inspection criteria.

One set of criteria was specified for INC snubbers and was based on numerous problems identified with these type snubbers.

The other set of criteria was for all other types of mechanical snubbers, which had experienced low failure rates.

The different criteria were not based on design differences, but rather generic problems identified with the INC snubbers.

7.

Not applicable to this submittal because subgrouping was not addressed.

These statements were removed from the safety evaluation.