Independent Spent Fuel Storage Installation; Nine Mile Point 1 and 2; and R. E. Ginna Regulatory Audit Summary for License Amendment Request to Revise Emergency Action Level Schemes (CAC Nos. MF9836, MF9840; EPID L-2017-LLA-02)
ML18120A320
Person / Time
Site: Calvert Cliffs, Nine Mile Point, Ginna  
Issue date: 05/07/2018
From: Blake Purnell
Plant Licensing Branch 1
To: Bryan Hanson
Exelon Generation Co
Purnell B
References
CAC MF9836, CAC MF9840, EPID L-2017-LLA-0237
Download: ML18120A320 (5)


Text

Mr. Bryan C. Hanson Senior Vice President UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 7, 2018 Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO)

Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

CALVERT CLIFFS NUCLEAR POWER PLANT, UNITS 1 AND 2; CALVERT CLIFFS INDEPENDENT SPENT FUEL STORAGE INSTALLATION; NINE MILE POINT NUCLEAR STATION, UNITS 1 AND 2; AND R. E. GINNA NUCLEAR POWER PLANT -

REGULATORY AUDIT

SUMMARY

FOR LICENSE AMENDMENT REQUEST TO REVISE EMERGENCY ACTION LEVEL SCHEMES (CAC NOS. MF9836-MF9840; EPID L-2017-LLA-0237)

Dear Mr. Hanson:

By application dated May 31, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17164A149), as supplemented by letter dated January 31, 2018 (ADAMS Accession No. ML18037A653), Exelon Generation Company, LLC (Exelon, the licensee) submitted a license amendment request (LAR) for Calvert Cliffs Nuclear Power Plant, Units 1 and 2; Nine Mile Point Nuclear Station, Units 1 and 2; and R. E. Ginna Nuclear Power Plant. The amendments would revise the emergency plans by changing the emergency action level schemes for these facilities. The proposed changes are based on the Nuclear Energy lnstitute's (NEl's) guidance in NEI 99-01, Revision 6, "Development of Emergency Action Levels for Non-Passive Reactors," which was endorsed by the U.S. Nuclear Regulatory Commission (NRC) by letter dated March 28, 2013 (ADAMS Accession No. ML12346A463).

By letter dated July 18, 2017 (ADAMS Accession No. ML171948082), the NRC staff informed Exelon of its plan to conduct a regulatory audit of nondocketed information to support the staff's review of the LAR. The audit was performed using an online reference portal.

The purpose of this letter is to inform Exelon that the NRC staff has completed its regulatory audit and no longer needs access to the online reference portal which was established for this LAR. A summary of the staff's audit is enclosed but the staff's review of the LAR is ongoing.

If you have any questions, please contact me by e-mail at Blake.Purnell@nrc.gov or by phone at (301) 415-1380.

Docket Nos. 50-317, 50-318, 72-8, 50-220, 50-410, 72-1036, 50-244, and 72-67

Enclosure:

Audit Summary cc: Listserv Blake Purnell, Project Manager Plant Licensing Branch Ill Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

REGULATORY AUDIT

SUMMARY

RELATED TO LICENSE AMENDMENT REQUEST TO REVISE EMERGENCY ACTION LEVEL SCHEMES CALVERT CLIFFS NUCLEAR POWER STATION, UNITS 1 AND 2 CALVERT CLIFFS INDEPENDENT SPENT FUEL STORAGE INSTALLATION NINE MILE POINT NUCLEAR POWER STATION, UNITS 1 AND 2 R. E. GINNA NUCLEAR POWER PLANT By application dated May 31, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17164A149), as supplemented by letter dated January 31, 2018 (ADAMS Accession No. ML18037A653), Exelon Generation Company, LLC (Exelon, the licensee) submitted a license amendment request (LAR) for Calvert Cliffs Nuclear Power Plant, Units 1 and 2; Nine Mile Point Nuclear Station, Units 1 and 2; and R. E. Ginna Nuclear Power Plant. The amendments would revise the emergency plans by changing the emergency action level (EAL) schemes for these facilities.

By letter dated July 18, 2017 (ADAMS Accession No. ML171948082), the NRC staff informed Exelon of its plan to conduct a regulatory audit of nondocketed information to support the staff's review of the LAR. The audit was performed using an online reference portal. The purpose of the audit was to verify assumptions and input used to calculate specific monitor thresholds in the proposed EALs.

The NRC staff reviewed calculations, analysis, and supporting documentations related to radiological effluent and containment radiation monitor thresholds in the proposed EALs. The specific documents reviewed were used to establish the thresholds for radiological effluent monitors in EALs RU 1, RA 1, RS 1, and RG 1 and the thresholds for containment radiation monitors in EALs FC3, RC3, CS6, and CG6. The complete list of documents reviewed is listed in the table below.

Document ID Document Title Document Date EP-EAL-0712, Criteria for Choosing Containment Radiation Values Revision 0 Indicating: Loss of Fuel Clad and Potential Loss of 1/23/2017 Containment for Ginna Station EP-EAL-0632, Calculation of Ginna Nuclear Power Station Table R-1 EAL 1/10/2017 Revision 0 Threshold Values EP-EAL-0512, Criteria for Choosing Containment Radiation Monitor Readings Revision 1 Indicative of Loss of RCS [Reactor Coolant System] Barrier for 2/22/2017 Ginna EP-EAL-0502, Estimation of Radiation Monitor Readings Indicating Core 1/3/2017 Revision 0 Uncovery During Refueling Ginna Station Enclosure Document ID Document Title Document Date EP-EAL-0634, Calculation of Nine Mile Point Unit 2 Table R-1 EAL Threshold 3/8/2017 Revision 0 Values EP-EAL-0514, Criteria for Choosing Drywall Radiation Monitor Reading 10/27/2016 Revision 0 Indicative of Loss of the RCS Barrier for NMP U2 EP-EAL-0504, Estimation of Radiation Monitor Readings Indicating Core 1/27/2017 Revision 0 Uncovery During Refueling Nine Mile Point Unit 2 Station EP-EAL-0713, Criteria for Choosing Containment Radiation Values Revision 0 Indicating: Loss of Fuel Clad and Potential Loss of 10/17/2016 Containment for Nine Mile Point Station Units 1 and 2 EP-EAL-0633, Calculation of Nine Mile Point Unit 1 Table R-1 EAL Threshold 3/8/2017 Revision 0 Values EP-EAL-0513, Criteria for Choosing Drywall Radiation Reading Indicative of 10/26/2016 Revision 0 Loss of the RCS Barrier for NMP U1 EP-EAL-0503, Estimation of Radiation Monitor Readings Indicating Core 1/27/2017 Revision O Uncoverv DurinQ RefuelinQ Nine Mile Point Unit 1 Station EP-EAL-0714, Criteria for Choosing Containment Radiation Values Indicating a Loss Fuel Clad and a Potential Loss of Containment at 1/26/2017 Revision 0 Calvert Cliffs EP-EAL-0635, Calculation of Calvert Cliffs Nuclear Power Plant Table R-1 2/7/2017 Revision 0 EAL Threshold Values EP-EAL-0511, Criteria for Choosing Containment Radiation Monitor Readings 11/18/2016 Revision 0 Indicative of Loss of the RCS Barrier for Calvert Cliffs EP-EAL-0505, Estimation of Radiation Monitor Readings Indicating Core 1/27/2017 Revision 0 Uncovery During Refueling Calvert Cliffs Station The NRC staff has completed its audit. Information identified during the audit which the staff needed to make a regulatory decision on the LAR was requested by letter dated December 12, 2017 (ADAMS Accession No. ML173318134). This audit summary does not include any staff findings or conclusions regarding the LAR or the audited documents.

ML18120A320 OFFICE D0RL/LPL3/PM D0RL/LPL3/LA NAME BPurnell SRohrer DATE 5/1/18 5/1/18 RidsNrrPMCalvertCliffs Resource RidsNrrPMNineMilePoint Resource RidsNrrPMREGinna Resource RidsNsirDpr Resource RidsNmssDsfmSflb Resource JAnderson, NSIR MNorris, NSIR RHoffman, NSIR

  • via memo NSR/DPR/RLB/BC D0RL/LPL3/BC D0RL/LPL3/PM JAnderson (MNorris for)*

DWrona BPurnell 4/17/18 5/7/18 5/7/18

Mr. Bryan C. Hanson Senior Vice President UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 May 7, 2018 Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO)

Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

CALVERT CLIFFS NUCLEAR POWER PLANT, UNITS 1 AND 2; CALVERT CLIFFS INDEPENDENT SPENT FUEL STORAGE INSTALLATION; NINE MILE POINT NUCLEAR STATION, UNITS 1 AND 2; AND R. E. GINNA NUCLEAR POWER PLANT -

REGULATORY AUDIT

SUMMARY

FOR LICENSE AMENDMENT REQUEST TO REVISE EMERGENCY ACTION LEVEL SCHEMES (CAC NOS. MF9836-MF9840; EPID L-2017-LLA-0237)

Dear Mr. Hanson:

By application dated May 31, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17164A149), as supplemented by letter dated January 31, 2018 (ADAMS Accession No. ML18037A653), Exelon Generation Company, LLC (Exelon, the licensee) submitted a license amendment request (LAR) for Calvert Cliffs Nuclear Power Plant, Units 1 and 2; Nine Mile Point Nuclear Station, Units 1 and 2; and R. E. Ginna Nuclear Power Plant. The amendments would revise the emergency plans by changing the emergency action level schemes for these facilities. The proposed changes are based on the Nuclear Energy lnstitute's (NEl's) guidance in NEI 99-01, Revision 6, "Development of Emergency Action Levels for Non-Passive Reactors," which was endorsed by the U.S. Nuclear Regulatory Commission (NRC) by letter dated March 28, 2013 (ADAMS Accession No. ML12346A463).

By letter dated July 18, 2017 (ADAMS Accession No. ML171948082), the NRC staff informed Exelon of its plan to conduct a regulatory audit of nondocketed information to support the staff's review of the LAR. The audit was performed using an online reference portal.

The purpose of this letter is to inform Exelon that the NRC staff has completed its regulatory audit and no longer needs access to the online reference portal which was established for this LAR. A summary of the staff's audit is enclosed but the staff's review of the LAR is ongoing.

If you have any questions, please contact me by e-mail at Blake.Purnell@nrc.gov or by phone at (301) 415-1380.

Docket Nos. 50-317, 50-318, 72-8, 50-220, 50-410, 72-1036, 50-244, and 72-67

Enclosure:

Audit Summary cc: Listserv Blake Purnell, Project Manager Plant Licensing Branch Ill Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

REGULATORY AUDIT

SUMMARY

RELATED TO LICENSE AMENDMENT REQUEST TO REVISE EMERGENCY ACTION LEVEL SCHEMES CALVERT CLIFFS NUCLEAR POWER STATION, UNITS 1 AND 2 CALVERT CLIFFS INDEPENDENT SPENT FUEL STORAGE INSTALLATION NINE MILE POINT NUCLEAR POWER STATION, UNITS 1 AND 2 R. E. GINNA NUCLEAR POWER PLANT By application dated May 31, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17164A149), as supplemented by letter dated January 31, 2018 (ADAMS Accession No. ML18037A653), Exelon Generation Company, LLC (Exelon, the licensee) submitted a license amendment request (LAR) for Calvert Cliffs Nuclear Power Plant, Units 1 and 2; Nine Mile Point Nuclear Station, Units 1 and 2; and R. E. Ginna Nuclear Power Plant. The amendments would revise the emergency plans by changing the emergency action level (EAL) schemes for these facilities.

By letter dated July 18, 2017 (ADAMS Accession No. ML171948082), the NRC staff informed Exelon of its plan to conduct a regulatory audit of nondocketed information to support the staff's review of the LAR. The audit was performed using an online reference portal. The purpose of the audit was to verify assumptions and input used to calculate specific monitor thresholds in the proposed EALs.

The NRC staff reviewed calculations, analysis, and supporting documentations related to radiological effluent and containment radiation monitor thresholds in the proposed EALs. The specific documents reviewed were used to establish the thresholds for radiological effluent monitors in EALs RU 1, RA 1, RS 1, and RG 1 and the thresholds for containment radiation monitors in EALs FC3, RC3, CS6, and CG6. The complete list of documents reviewed is listed in the table below.

Document ID Document Title Document Date EP-EAL-0712, Criteria for Choosing Containment Radiation Values Revision 0 Indicating: Loss of Fuel Clad and Potential Loss of 1/23/2017 Containment for Ginna Station EP-EAL-0632, Calculation of Ginna Nuclear Power Station Table R-1 EAL 1/10/2017 Revision 0 Threshold Values EP-EAL-0512, Criteria for Choosing Containment Radiation Monitor Readings Revision 1 Indicative of Loss of RCS [Reactor Coolant System] Barrier for 2/22/2017 Ginna EP-EAL-0502, Estimation of Radiation Monitor Readings Indicating Core 1/3/2017 Revision 0 Uncovery During Refueling Ginna Station Enclosure Document ID Document Title Document Date EP-EAL-0634, Calculation of Nine Mile Point Unit 2 Table R-1 EAL Threshold 3/8/2017 Revision 0 Values EP-EAL-0514, Criteria for Choosing Drywall Radiation Monitor Reading 10/27/2016 Revision 0 Indicative of Loss of the RCS Barrier for NMP U2 EP-EAL-0504, Estimation of Radiation Monitor Readings Indicating Core 1/27/2017 Revision 0 Uncovery During Refueling Nine Mile Point Unit 2 Station EP-EAL-0713, Criteria for Choosing Containment Radiation Values Revision 0 Indicating: Loss of Fuel Clad and Potential Loss of 10/17/2016 Containment for Nine Mile Point Station Units 1 and 2 EP-EAL-0633, Calculation of Nine Mile Point Unit 1 Table R-1 EAL Threshold 3/8/2017 Revision 0 Values EP-EAL-0513, Criteria for Choosing Drywall Radiation Reading Indicative of 10/26/2016 Revision 0 Loss of the RCS Barrier for NMP U1 EP-EAL-0503, Estimation of Radiation Monitor Readings Indicating Core 1/27/2017 Revision O Uncoverv DurinQ RefuelinQ Nine Mile Point Unit 1 Station EP-EAL-0714, Criteria for Choosing Containment Radiation Values Indicating a Loss Fuel Clad and a Potential Loss of Containment at 1/26/2017 Revision 0 Calvert Cliffs EP-EAL-0635, Calculation of Calvert Cliffs Nuclear Power Plant Table R-1 2/7/2017 Revision 0 EAL Threshold Values EP-EAL-0511, Criteria for Choosing Containment Radiation Monitor Readings 11/18/2016 Revision 0 Indicative of Loss of the RCS Barrier for Calvert Cliffs EP-EAL-0505, Estimation of Radiation Monitor Readings Indicating Core 1/27/2017 Revision 0 Uncovery During Refueling Calvert Cliffs Station The NRC staff has completed its audit. Information identified during the audit which the staff needed to make a regulatory decision on the LAR was requested by letter dated December 12, 2017 (ADAMS Accession No. ML173318134). This audit summary does not include any staff findings or conclusions regarding the LAR or the audited documents.

ML18120A320 OFFICE D0RL/LPL3/PM D0RL/LPL3/LA NAME BPurnell SRohrer DATE 5/1/18 5/1/18 RidsNrrPMCalvertCliffs Resource RidsNrrPMNineMilePoint Resource RidsNrrPMREGinna Resource RidsNsirDpr Resource RidsNmssDsfmSflb Resource JAnderson, NSIR MNorris, NSIR RHoffman, NSIR

  • via memo NSR/DPR/RLB/BC D0RL/LPL3/BC D0RL/LPL3/PM JAnderson (MNorris for)*

DWrona BPurnell 4/17/18 5/7/18 5/7/18