Application for Amend to License DPR-75,incorporating Plant Computer (P-250) Into TS Bases for Movable Control Assemblies
ML18102B532
Person / Time
Site: Salem PSEG icon.png
Issue date: 08/18/1997
From: Dawn Powell
Public Service Enterprise Group
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18102B533 List:
References
LR-N970532, NUDOCS 9708260110
Download: ML18102B532 (2)


Text

OPS~G

  • Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit AUG 1 8 1997 LR-N970532 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 TECHNICAL SPECIFICATION BASES CHANGES SALEM GENERATING STATION UNIT NO. 2 DOCKET NO. 50-311 FACILITY OPERATING LICENSE DPR-75 Gentlemen:

Public Service Electric and Gas Company (PSE&G) is providing revised Technical Specification (TS) Bases pages for Technical Specification 3/4.1.3 "Movable Control Assemblies." The revised pages incorporate the plant computer (P-250) into the Technical Specification Bases for _the Movable Control Assemblies, and were I reviewed through the 10CFR50.59 process by the Station Operations Review Committee and approved by the General Manager - Salem Operations.

The BASES for Technical Specification 3/4.1.3 (B3/4.1.3) are to ensure that: (1) acceptable power distribution limits are maintained, (2) the minimum shutdown margin is maintained, and (3) limit the potential effects of rod mis-alignment on associated accident analysis. Incorporating the P-250 as an alternate method of determining rod position has been determined to be acceptable, based in part on: (1) the Technical Specification Limiting condition for Operation does not describe any specific instrument to determine rod position, (2) the power supplies for both, the control console indication and the P-250 are supplied with reliable battery backed power supplies, and (3) the accuracy of the P-250 is equal or better than the control console indication.

9708260110 970818 PDR .. ADOCK 05000311 p . PDR

  • 1111111111111111111111111111111111111111
  • sssce,.

The power is in your hands.

95-2168 REV. 6/94 L

[

Document Control Desk LR"-N970532 2 AUG 18 1997 Attachment 1 contains the revised page for Salem Unit No. 2 Technical Specification Bases. Please incorporate these changes into the Technical Specifications.

Should there be any questions with regard to this submittal, please do not hesitate to contact us.

Sincerely, D. R. Powell Director Licensing & Regulation/Fuels c Mr. Hubert J. Miller, Administrator - Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. L. N. Olshan, Licensing Project Manager - Salem U. S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mail Stop 14E21 Rockville, MD 20852 Ms. M. Evans (X24)

USNRC Senior Resident Inspector Salem Generating Station Mr. K. Tosch, Manager, IV Bureau of Nuclear Engineering 33 Arctic Parkway CN 415 Trenton, NJ 08625