ACCESSION NBR:9012030042 DOC.DATE: 90/11/27 NOTARIZED: NO DOCKET g FACIL:50-250 Turkey Point Plant, Unit 3, Florida Power and Light C 05000250 50-251 Turkey Point Plant, Unit 4, Florida Power and Light C 05000251 AUTH. NAME AUTHOR AFFILXATION PLUNKETT,T.F. Florida Power 6 Light Co.
RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
NPDES noncompliance notification:on 900906,discovered that rainwater pumped from sump to Biscayne Bay.
DISTRIBUTION CODE: IE23D COPIES RECEIVED:LTR Q ENCL J SIZE:
TXTLE: Environmental Event Report (per Tech Specs)
NOTES:
RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-2 LA 3 3 PD2-2 PD 1 1 EDISON,G 1 1 INTERNAL: AEOD/DSP/TPAB 1 1 AEOD/PTB 1 1 NRR/DREP/PEPB9D 1 1 RR ILRB12 1 1 OGC/HDS2 1 1 REG FILE 01 1 1 RGN2 1 1 2/DRSS/EPRPB 1 1 EXTERNAL NRC PDR 1 1 NSIC 1 1 NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASfE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED: LTTR 15 ENCL 15
. I t
t
~4
P.O. Box14000, Juno Beach, Ft. 33408-0420 PIPll NOY 27 990$
L-90-391 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Gentlemen:
Re: Turkey Point Unit 3 & 4 Dockets No. 50-250 and 50-251 Enviromental Protection Plan Report National Pollutant Discharge Elimination S stem NPDES Re ortable Event In accordance with Section 3.2.1. of the Turkey Point Units 3 and 4 Enviromental Protection Plan (Appendix B of Plant Licenses), attached is a copy of the Discharge Monitoring Report (DMR) required by the Turkey Point Plant NPDES Permit with respect to a reportable event (attachment 1).
Additionally, a description of the event is enclosed (attachment 2).
Should you have any questions, please contact us.
Very truly yours, T. F. Plunkett Vice President Turkey Point Nuclear TFP/DPS/ds enclosure cc: Stewart D. Ebneter, Regional Administrator, Region II, USNRC, Senior Resident Inspector, USNRC, Turkey Point Plant 9012030042 9oil27 PDR s
ADOCK 05000250 PDC /z an FPL Group company
~L
'I
~,
'I
ATTACHMENT 2 TO LETTER L-90-391 The Turkey Point Fossil Power Plant is currently in the process of regrading the fuel oil storage tank area to direct rainwater runoff toward a sump with an emergency overflow to the cooling canal system. This project has been permitted by Dade County's Department of Environmental Resources Management (DERM) and is being constructed by a local contractor.
On September 6, 1990, the contractor was discovered pumping rainwater from the sump to the turning basin which is in Biscayne Bay. Plant personnel directed the contractor to cease pumping water immediately. After further investigation, FPL was informed that a six inch pump was used to pump the rainwater at a rate of approximately 1100 gallons per minute for 15 minutes. Thus a total of 16,500 gallons of rainwater was pumped to the turning basin. No sheen or any other adverse environmental impacts were observed.
The contractor has been advised that all dewatering activities require proper permitting and that discharges without proper permits to waters of the United States are not allowed at Turkey Point. The general specification for contractors and the FPL General Terms and Conditions, parts 13 and 16 require contractors to obtain their own permits and to abide by state and Federal requirements.
PERMITTEE NAME(AODAESS(l>55(i>dr IIATION*LPOLLUTANT O5SCMARGE ELIMINATIONSYSTF M (NPDES J
)ori(i(y)re>>irlL((re(ion I((tiy)rrred DISCHARGE MONITORING REPORT(DMR)
NAME I I i 'vi;;. t. I T l I.IRKF Y I (I I NT (3-td) (l7-)9J F FINAL
..rIV I "IIN.I(.NTAL AFFAIRS Dl I' FL0001,) 62 001 1 CLOSED CYCLE COOLING CANAl SYST 'I PO "IIX 1 <000 PEAMIT HUMSEA OISCHAAOE NUMSBl JI.IN!l ILEA' FL 33(e08 MONITORING PERIOD FAcluTY F L PI((R 6 LT TUP. KF Y PO I NT Y R MO DAY Y MO D Y iooaoooHIAMI M.>LP~(>L FL 33101 FROM TO MAJOR (SUBR HP)
ATTN- IRON,-MGo (3p.33) (33-33) (3d-zs) (3d-37) (23-39) (Set) NOTE: Read lnatfuctlons before cofnpletlng this foftn.
(3 Cunt Only) OUANTITYORLOADING (d Cunt Only) OUAuTYOR CONCENTRATION FREQUENCY PAIIAMETKR (dd S3) ($461 J (344SJ (ddhf3) (SAflJ NO. SAMPLE EX OF TYPE P?47) ANALYSIS AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS d343 (6AS) (d9 7g)
A gA J4 rh)h FLOWe IN CONDUIT OR SAMPLE THOU TREATNIEAfT PLAN MEASUREMEHT A -'rv SOOSO I. O 0 PERMIT Jl
~
~~
EFFLfjEAlT 6kaSS 'I('ALQ TREQUIREM ~ >i o>;, DAO='Y tMK- MGD SAMPLE MEASUREMENT PERM'I
'REQUIREME(ltc+g .
g!.'g ~~ ~ h
~ trV( L ~, h>
y,'AMPLE MEASUREMENT 5(
PERMIT
~
I 5:
.REQUIREMENT hi> > ~
SAMPLE MEASUREMENT PBIMIT ~
REQUIRELIEHT, 5 ~
i 3') ~
SAMPLE MEASUREMKHT
~ I>
Ii PERMIT I'>'i"
~ 5
',REQUIREMENT' h
t) var)
SAMPLE L'QUIA MEASUAEMEHT or ;Qf;5, W ~ h I SAMPLE MEASUREMENT ro IO v- '"f> .> ~ ~ 5
~ ~ (
PERM ~
REQUIR 15, I certify under penalty ol Iaw that this document arid all attachments were prepared under my direction or supeivWon In accordance with a OATS NAME/TITLEPRINCIPAL EXECUTIVEOFFICER syslem designed lo assure that qualitied personnel properly gather and TELEPHONE evaluate the Information submitted. Based on my Inquiry of the person Or persons who Illanage the systelll. of Ihose persons directly responsible lor M. H. Brunetti therlng the Inlonnadon. the Information submitted h. to the best ot my 305 246-617 90 10 Ol
~ nd belief. true. accurate. and complete. I am aware that there Executive Vice President are stgnt kant penaIIUes for submltdng false Informatkn, Including the IGNATUREOFP I CIPAL EXECUTIVE poastbtltty of nne and Imprisonment for Iutowlng violations. $
TYPED OR PRINTED OFHCER OR AUTHORIZEDAGENT HUMSEA COMMENT AND EXPLANATIONOF ANYVIOLATIONS(Rc(rrencrutturfuctr(rrenra frere)
BIO
'll C'IAI,"I- (ILL'II(JElt~ Il= DI SCHWA R" I: 3CCIJRSY REPORT FI.OH AND ATTACH lETTER OF EXPLANATION (INCLUOE LENGTH II. Till 9f il.l<4R " AN(i RFASAN F.OI'. TIIl. 01!TCHAP( C) TN LIFU OF CONTINUOUS RFCOROINGe HOURLY FLOM MEASUREMENTS YHOTSKUSE04 PA'Forfn 3320. (Rsv. MS) Prwlofts'all(Iona (nay rO JLo h~2 I ~+or ftsed. AEP A WHIC 0101.9/900709-2027 I